ST9905-LR070320 '" ECS Texas, LLP gs: 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0 I 02 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TI!XA8 TO: City of Coppell P.O. Box 9478 DATE: 03/20/2008 RE: Bethel Road - Coppell Coppell, TX 75019 ATTN: Ms. Carol Dye PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 112, 113, 126 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell By: .....,....,''-'''',,'1: _~~~:\'C. OF 1[.' III, ,:-- ,,\'- .,d'--""~-1 ". :- 0,/ *' "".,<S'. '" i:~-- .....:-,*;\. ~ ~R..';.:,:;.;.;.,."": M~rk. R. to~,P:f~f' :'1ri~10 2008 Prmclpal Er&!J.1eer9 db i i ,4j f ~, 0";',. (ICcc,("C'-' '",,'.f.r:; I~I ~'<::" ,.., ,'" , ,0:' _.;' Il,,'S/GNA\.. 't"._--- ll\\\\V\ "",............ ~c(3~ Eric L. Branch, C.E.T. Project Manager Concrete Cylinders Strength Report .. ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 I~ Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/20/2008 3600 psi 112 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Box culvert floor, sampled from 10' E and 6' S from NW comer Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 966 Mix Strength: 3600 pSI Time Added: Ticket No: 3244822 Batch Time: 09:15AM Unit Wt.: FIELD TEST DATA: Tested by: Michael 1. Cochran Temperature - Air: 630 F Time Sampled:09:57 AM Concrete: 660 F Slump:5.25 in. Air Content:4.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39042 02/27/2008 7 Lab 4.00 12.56 59872 4760 ELBl 39043 03/19/2008 28 Lab 4.00 12.56 73120 5820 4 ELBl 39044 03/19/2008 28 Lab 4.00 ]2.56 77472 6170 5 ELBl 39045 04/] 6/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance With (law) ASTM C172, exceptlhat samples may have been laken from the beginning of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using un bonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By:-- ~ < ~ ,---- ELBl Print Date: 03/20/2008 Concrete Cylinders Strength Report " ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 I DAB Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: B 02/2012008 3600 psi 113 Owner: City of Coppell - Carol Dye Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Driverway, sampled N side of driveway 2' S & 2' E ofNW comer Concrete Supplier: Southern Star Mix Designation: 7795 Added Water: Truck No: 84 Mix Strength: 3600 pSI Time Added: Ticket No: 1205916 Batch Time: 01 :30PM Unit Wt.: FIELD TEST DATA: Tested by: Michael 1. Cochran Temperature - Air: 670 F Time Sampled:Ol :55PM Concrete: 750 F Slump:7.00 in. Air Content:5.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39046 02/27/2008 7 Lab 4.00 12.56 76480 6090 ELBl 39047 03/19/2008 28 Lab 4.00 12.56 89324 7110 3 ELBl 39048 03/19/2008 28 Lab 4.00 12.56 92192 7340 3 ELBl 39049 04/16/2008 56 Lab 4.00 12.56 Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM Cl064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ~7 ELBl Print Date: 03/20/2008 ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _T1!XA8 Concrete Cylinders Strength Report Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 03/12/2008 4000 psi 126 Owner: City of Coppell - Carol Dye Arch.: Struc. Eng.: Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: Placement Location: East driveway for CiCi's warehouse, stamped concrete Concrete Supplier: Southern Star Mix Designation: 9363 Added Water: 20 Gals. Truck No: 1043 Mix Strength: 4000 psi Time Added: 10:30A Ticket No: 1218052 Batch Time: 09:45AM Unit Wt.: FIELD TEST DATA: Tested by:Jonathan E. Steiner Temperature - Air: 700 F Time Sampled:l0:45AM Concrete: 780 F Slump:4.00 in. Air Content:3.30 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39433 03/19/2008 7 Lab 4.00 12.56 60352 4800 3 ELB1 39434 04/09/2008 28 Lab 4.00 12.56 39435 04/09/2008 28 Lab 4.00 12.56 39436 05/07/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance With (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 03/20/2008