Loading...
ST9905-LR070313 ECS Texas. LLP 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 LETTER OF TRANSMITTAL E TI!XAS March 13, 2008 RE: Bethel Road - Coppell City of Coppell P.O. Box 9478 Coppell, TX 75019 ECS Job # 19:5061 Pennits: A TTN: Mr. Rick O'Dell Location: Bethel Road Coppell, TX We are enclosing: --L Materials Engineering Division Reports --L For your use --L As requested CC: TISEO Paving - Robert Caudill City of Coppell - Carol Dye ENCL: Field Report # 158 03/12/2008 LaLCf;t.- ~l(~ Eric L. Branch, C.E.T. Project Manager Principal Engineer " '" ECS Texas. LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 . .. (972) 392-3222 .-.r (FAX) 392-0102 FIELD REPORT Project No. Report No. Day & Date Weather On-Site Time Lab Time Travel Time* Total Re Obs.Time TI!XA8 Project Bethel Road - Coppell Location Coppell, TX Client City of Coppell - Rick O'Dell Remarks Trip Charges* Chargeable Items 19:5061 158 Wednesday 03/12/2008 700/ Sunny 2.25 0.00 1.00 3.25 0.00 18.00 T olls/Parking* Mileage* Time of Arrival Departure 09:30A 11:45A * Travel time and mileage will be billed in accordance with the contract. Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to observe: 1. The placement of 8 cubic yards of 4000 psi concrete for the CiCi's East driveway. The required test limits were determined to be a slump of 3-5 inches, air content of 3-6 %, batch to placement time of <90 minutes, and concrete temperature range of <90 degrees Fahrenheit. Concrete observed on this date appeared to be placed in compliance with project specifications with regard to temperature, slump, air content, and batch to placement time. The following samples were obtained for compressive strength testing in our laboratory: SetA: 1 set of 4 lab cylinders (4000 psi) for paving By Jonathan E. Steiner, - Field Technician 1800 94085 .. ECS Texas, LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TI!XA8 TO: City of Coppell P.O. Box 9478 DATE: 03/1312008 RE: Bethel Road - Coppell Coppell, TX 75019 A TTN: Mr. Rick O'Dell PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 109, 125 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell City of Coppell - Carol Dye f)~~ ~-~ David A. Lewis, P .E. Principal Engineer ~ -((~ Eric L. Branch, C.E.T. Project Manager By: ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0 I 02 Concrete Cylinders Strength Report _T1!XAS Project Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/13/2008 3600 psi 109 Owner: City of Coppell - Carol Dye Client City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Box Culvert Walls: 1000 ft from Freeport on Bethel Road Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 1124 Mix Strength: 3600 pSI Time Added: Ticket No: 3244485 Batch Time: 01:22PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 600 F Time Sampled:02:30PM Concrete: 750 F Slump: 5.00 in. Air ContentO.80 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 38937 02/20/2008 7 Lab 4.00 12.56 50112 3990 3 ELBl 38938 03/12/2008 28 Lab 4.00 12.56 67104 5340 ELBl 38939 03/12/2008 28 Lab 4.00 12.56 67360 5360 3 ELBl 38940 04/09/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance With (law) ASTM Cl72. except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C231 (P), temperature iaw ASTM Cl064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3. 4, 5. or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: PJ~~:.. ELBl Print Date: 03/13/2008 Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 7500 I (972) 392-3222 (FAX) 392-0102 Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 03/05/2008 4000 psi 125 Owner: City of Coppell - Carol Dye Arch.: Struc. Eng.: Placement Location: Box culvert top, 330 ft West of the 113 Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: NE comer of the Minyards NE comer, 45 ft N of door Concrete Supplier: LMC Mix Designation: 1851 Added Water: Truck No: 1002 Mix Strength: 4000 pSI Time Added: Ticket No: 3245649 Batch Time: 04:07PM Unit Wt.: FIELD TEST DATA: Tested by:David L. Hunt Temperature - Air: 620 F Time Sampled:03 :02PM Concrete: 720 F Slump: 5.40 in. Air Content:2.60 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39406 03/12/2008 7 Lab 4.00 12.56 79712 6340 3 ELB1 39407 03/12/2008 7 Lab 4.00 12.56 79488 6330 3 ELB1 39408 03/12/2008 7 Lab 4.00 12.56 73344 5840 3 ELB1 39409 04/02/2008 28 Lab 4.00 12.56 39410 04/02/2008 28 Lab 4.00 12.56 39411 04/02/2008 28 Lab 4.00 12.56 . . Sampling In accordance With (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump law C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps law ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELB1 Print Date: 03/13/2008