ST9905-LR070307 ,., ECS Texas, LLP gs: 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TI!XAS TO: City of Coppell P.O. Box 9478 DATE: 03/07/2008 RE: Bethel Road - Coppell Coppell, TX 75019 ATTN: Mr. Rick O'Dell PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX Weare enclosing: X Attached Materials Engineering Division Concrete Reports: 122, 123, 124 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell tJJi? L Davicf A. Lewis, P.E. Principal Engineer ~(l~ Eric L. Branch, C.E.T. Project Manager By: Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Concrete Cylinders Strength Report Project: 5061 Set Designation: A Cast Date: 02/29/2008 Design Strength: 4000 psi Report No.: 122 ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 7500] (972) 392-3222 (FAX) 392-0 I 02 _TIIXAS Owner: City of Coppell - Rick O'Dell Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Stamped concrete for Entech, 1000 ft East of Royal Lane on Bethel Rd Concrete Supplier: Southern Star Mix Designation: 9363 Added Water: Truck No: 931 Mix Strength: 4000 pSI Time Added: Ticket No: Batch Time: Unit Wt.: 1214324 09:45AM FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 700 F Time Sampled: 1 0:20AM Concrete: 740 F Slump:4.00 in. Air Content:3.20 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39365 03/07/2008 7 Lab 4.00 12.56 51936 4130 ELBl 39366 03/28/2008 28 Lab 4.00 12.56 39367 03/28/2008 28 Lab 4.00 12.56 39368 04/25/2008 56 Lab 4.00 12.56 . . . . Sampling in accordance With (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39. slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM Cl064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar jaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 03/0712008 Concrete Cylinders Strength Report N ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 7500] (972) 392-3222 (FAX) 392-0 I 02 11!XAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: B 02/29/2008 3600 psi 123 Owner: City of Coppell - Rick O'Dell Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Box culvert walls, sampled at Sta. 44+50 Concrete Supplier: LMC Mix Designation: 170 I Added Water: 5 Gals. Truck No: 7060 Mix Strength: 3600 pSi Time Added: --:- Ticket No: 7189201 Batch Time: 01:36PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 760 F Time Sampled:02: 15PM Concrete: 790 F Slump: 5.00 in. Air Content:6.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39377 03/07/2008 7 Lab 4.00 12.56 49408 3930 ELBl 39378 03/28/2008 28 Lab 4.00 12.56 39379 03/28/2008 28 Lab 4.00 12.56 39380 04/25/2008 56 Lab 4.00 12.56 . . . . Sampfing In accordance With (law) ASTM Cl72, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C3l, compressive strength test and break type law ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C23l (P), temperature iaw ASTM Cl064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C123l or are capped using sulphur mortar iaw C6l7. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 03/07/2008 Concrete Cylinders Strength Report '" ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _1"I!XA8 Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX City of Coppell - Rick O'Dell Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: C 02/29/2008 4000 psi 124 Owner: Arch.: Struc. Eng.: Placement Location: Inlet top at East entrance to Cici's. Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: Concrete Supplier: Southern Star Mix Designation: 9363 Added Water: Truck No: 1020 Mix Strength: 4000 psi Time Added: Ticket No: 1214859 Batch Time: 01 :52PM Unit Wt.: FIELD TEST DATA: Tested by:Jonathan E. Steiner Temperature - Air: 780 F Time Sampled:03 :OOPM Concrete: 800 F Slump: 3.50 in. Air Content:} .30 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39381 03/07/2008 7 Lab 4.00 12.56 44288 3520 ELB1 39382 03/28/2008 28 Lab 4.00 12.56 39383 03/28/2008 28 Lab 4.00 12.56 39384 04/25/2008 56 Lab 4.00 12.56 . . Samp6ng In accordance With (law) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using un bonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELB1 Print Date: 03/07/2008 ECS Texas. LLP 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 LETTER OF TRANSMITTAL gs: TEXAS March 7, 2008 RE: Bethel Road - CoppeIl City of Coppell P.O. Box 9478 Coppell, TX 75019 ECS Job # 19:5061 Pennits: A TTN: Mr. Rick O'Dell Location: Bethel Road CoppeIl, TX We are enclosing: --L Materials Engineering Division Reports --L For your use --L As requested CC: TISEO Paving - Robert Caudill ENCL: Field Report # 156 03/05/2008 f~~d~'J ~ C(3~ Eric L. Branch, C.E.T. Project Manager Principal Engineer '" ECS Texas. LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 FIELD REPORT Project No. Report No. Day & Date Weather On-Site Time Lab Time Travel Time* Total Re Obs.Time TI!XA8 Project Bethel Road - Coppell Location Coppell, TX Client City of Coppell - Rick O'Dell Remarks Trip Charges* Chargeable Items 19:5061 156 Wednesday 03/05/2008 620/ Sunny 2.00 0.00 1.00 3.00 0.00 18.00 Tolls/Parking* $0.40 Mileage* Time of Arrival Departure 01:30P 03:30P * Travel time and mileage will be billed in accordance with the contract. Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to observe: 1. The placement of 60 cubic yards of 4000 psi concrete for box culvert deck at Bethel Rd. The required test limits were determined to be a slump of 3-6 inches, batch to placement time of <90 minutes, and concrete temperature range of <90 degrees Fahrenheit. Concrete observed on this date appeared to be placed in compliance with project specifications with regard to temperature, slump, and batch to placement time. The air content was slightly below the project requirements. The following samples were obtained for compressive strength testing in our laboratory: SetA: 6 cylinders of 4000 psi concrete for compressive strength testing. By David L. Hunt, - Field Technician 1800 93967