Loading...
ST9905-LR070304 '" ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 u.P (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TI!XA8 TO: City of Coppell P.O. Box 9478 DATE: 03/04/2008 RE: Bethel Road - Coppell Coppell, TX 75019 ATTN: Mr. Rick O'Dell PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 103,106 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell I!./er .L~ David A. Lewis, P .E. Principal Engineer ~,~ By: Eric L. Branch, C.E.T. Project Manager Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _11!XA8 Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX City of Coppell - Rick O'Dell Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/04/2008 4000 psi 103 Owner: Arch.: Struc. Eng.: Placement Location: Inlet, 200' West of Royal lane. Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 5005 Mix Strength: 4000 pSI Time Added: Ticket No: 3243976 Batch Time: 04:55PM Unit Wt.: FIELD TEST DATA: Tested by:Jonathan E. Steiner Temperature - Air: 700 F Time Sampled:05:36PM Concrete: 800 F Slump:5.00 in. Air Contentl.70 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review I No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 38750 02/11/2008 7 Lab 4.00 12.56 54224 4320 3 ELB1 38751 03/03/2008 28 Lab 4.00 12.56 65088 5180 ELBI 38752 03/03/2008 28 Lab 4.00 12.56 67488 5370 ELBI 38753 03/31/2008 56 Lab 4.00 12.56 Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2, 3, 4, 5, or 6 jaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: .f)&...rI4/ ~.6 > ELBI Print Date: 03/04/2008 Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 7500] (972) 392-3222 (FAX) 392-0102 _T1!XM Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: B 02/04/2008 4000 psi 106 Owner: City of Coppell - Rick O'Dell Arch.: Struc. Eng.: Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: Placement Location: decorative crosswalk at the entrance to Uline/Computron Buildings Concrete Supplier: Southern Star Mix Designation: 9363 Added Water: Truck No: 3441 Mix Strength: 4000 pSI Time Added: Ticket No: Batch Time: Unit Wt.: 1193418 09:00AM FIELD TEST DATA: Tested by: David L. Hunt Temperature - Air: 740 F Time Sampled:09:35AM Concrete: 680 F Slump:OAO in. Air Content:2.20 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 38839 02/1112008 7 Lab 4.00 12.56 46368 3690 3 ELB1 38840 03/03/2008 28 Lab 4.00 12.56 59744 4750 ELB1 38841 03/03/2008 28 Lab 4.00 12.56 61184 4870 ELB1 38842 03/31/2008 56 Lab 4.00 12.56 Sampling in accordance with (iaw) ASTM C 172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1 064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ;JJ~ :L~ ELB1 Print Date: 03/04/2008 N ECS Texas, LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TI!XAS TO: City of Coppell P.O. Box 9478 DATE: 03/04/2008 RE: Bethel Road - Coppell Coppell, TX 75019 A TTN: Mr. Rick O'Dell PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX We are enclosing: X Attached Materials Engineering Division Concrete Reports: 104, 118 X X For Your Use X As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell J2/~.i-~ David A. Lewis, P .E. Principal Engineer ~3~ Eric L. Branch, C.E.T. Project Manager By: ~ ECS Texas, LLP gs: 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _T1!XAS Concrete Cylinders Strength Report Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/05/2008 3600 psi 104 Owner: City of Coppell - Rick O'Dell Arch.: Struc. Eng.: Placement Location: Middle of box culvert wall at sta 57+00 Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: Concrete Supplier: LMC Mix Designation: 1701 Added Water: Truck No: 7025 Mix Strength: 3600 pSI Time Added: Ticket No: 7188080 Batch Time: 03:00PM Unit Wt.: FIELD TEST DATA: Tested by: Yaw B. Boaitey Temperature - Air: 700 F Time Sampled:03 :45PM Concrete: 650 F Slump: 5.00 in. Air Content:4.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 38762 02/12/2008 7 Lab 4.00 12.56 59584 4740 3 ELB1 38763 03/04/2008 28 Lab 4.00 12.56 87200 6940 5 ELB1 38764 03/04/2008 28 Lab 4.00 12.56 84000 6680 3 ELB1 38765 04/01/2008 56 Lab 4.00 12.56 . . . . Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P). temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2, 3, 4, 5. or 6 iaw C39-04a FIELD CURING CONDITIONS: X Curing Box Insulated No Curing Box Heated Remarks: middle wall at Sta. 57 + 00 Cooled X Caps Ice Other Final Review By: ~a/~ L r ELB1 Print Date: 03/04/2008 Concrete Cylinders Strength Report N ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 _'TI!XAS Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/26/2008 3600 psi 118 Owner: City of Coppell - Rick O'Dell Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Paving, approximately 60' S of center island of Royal at Bethel intersection. Concrete Supplier: Tiseo Paving Company Mix Designation: 2478H Added Water: Truck No: 166 Mix Strength: 3600 pSI Time Added: Ticket No: Batch Time: 09:05AM Unit Wt.: FIELD TEST DATA: Tested by: Michael 1. Cochran Temperature - Air: 500 F Time Sampled:09:45AM Concrete: 620 F Slump: 6.00 in. Air Content:4.80 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39204 03/04/2008 7 Lab 4.00 12.56 61056 4860 3 ELBl 39205 03/25/2008 28 Lab 4.00 12.56 39206 03/25/2008 28 Lab 4.00 12.56 39207 04/22/2008 56 Lab 4.00 12.56 . . . . Sampling in accordance with (iaw) ASTM C172, except thaI samples may have been taken from the beginning of the load after a minimum dIScharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2,3,4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 03/04/2008