Chicken Express-LR080912 l-'s.lIriformation ~.,. .To Build On Engineering. Consulting . 'Rtstlng REPORT OF FIELD TESTING OF CONCRETE TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX DATE: September 12, 2008 PSI REPORT NO.: 341-80040-39 FIELD DATA: Concrete was a 4500 psi mix delivered by Gateway Concrete, mix number 605. NO. OF CONCRETE CUBIC TEMPERATURE, of I SPECIMENS SUPPLIER TIME TRUCK TIME TRUCK YARDS OF AIR CONCRETE I SET NO. MADE TICKET NUMBER DISPATCHED UNLOADED CONCRETE SLUMP, ,n. CONTENT, % AIR , , 2114 4 51267 12:45 pm 02:30 pm 10.0 3 3/4 5.1 93 90 I : I I ! I I I I I I , LOCATION: Entrance Off of Denton Tap Road 2114 I ! Entrance Ramp i NOTE. APPliCABLE ASTM STANDARDS, UNLESS OTHERWISE INDICATED: MAKING SPECIMENS C31 (EXC SEC 10.1.21; SLUMP: C 143; AIR CONTENT. C231 IEXC SEC 6): TEMPERATURE Cl064; SAMPLING Cl72 REMARKS: Observed the placement of 10.0 cubic yards of concrete. TECHNICIAN: Gabriel Ortiz Respectfully submitted, Professional Service Industries, Inc. cc: Hynes; Davis; Stone THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC PSI A-200-' (8JF Professional Service Industries. Inc.. 4087 Shilling Way. Dallas. TX 75237 . Phone 214/330-9211 . Fax 214/467-0031 l- ~~;l lriformotion ~.,. .To Build On Engineering . Consulting. 7itstIng REPORT OF FIELD TESTING OF CONCRETE TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX DATE: September 12, 2008 PSI REPORT NO.: 341-80040-41 FIELD DATA: Concrete was a 4500 psi mix delivered by Gateway Concrete, mix number 605. NO. OF CONCRETE CUBIC TEMPERATURE, OF SPECIMENS SUPPLIER TIME TRUCK TIME TRUCK YARDS OF AIR SET NO. MADE TICKET NUMBER DISPATCHED UNLOADED CONCRETE SLUMP, in. CONTENT, % AIR CONCRETE 2115 4 51270 02:00 pm 03:45 pm 10.0 4 1/2 5.3 90 91 I I I I I LOCATION: Sidewalk Off of Beltline Road 2115 Sidewalk Off of Beltline Road I I I \ i I I I NOTE: APPLICABLE ASTM STANDARDS. UNLESS OTHERWISE INDICATED MAKING SPECIMENS: C31(EXC. SEC. 10.1.2); SLUMP' C143: AIR CONTENT C231 (EXC. SEC. 6): TEMPERATURE: C1064; SAMPLING: C172 REMARKS: Observed the placement of 10.0 cubic yards of concrete. TECHNICIAN: Gabriel Ortiz Respectfully submitted, Professional Service Industries, Inc. cc: Hynes; Davis; Stone THESE TEST RESULTS APPL Y ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT REPORTS MAY NOT BE REPRODUCED. EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC PSI A-200-1 (8)F Professional Service Industries, Inc. . 4087 Shilling Way. Dallas. TX 75237. Phone 214/330-9211 . Fax 214/467-ClO31