Loading...
Chateaus-LR080911 Rone En:==- 8908 Ambassador Row, Dalla, TX 75247 7701 W Little York, ale 600, Houston, TX 77040 4421 Freldrlch, SIe 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC clo Lenart Development Co., LLC 4601 Old Shepard Place Piano, TX 75093 Report No.: 332039 Project No.: 0814523 Date of Service: 09/03/2008 Report Date: 09/11/2008 Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Concrete Supplier: Lattimore Plant: 6 Specification Requirements Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 1701 Placement Date: 09/03/2008 Weather Conditions: Cloudy, windy Time Sampled: 02:50pm Batch time: 02:01 pm Temperature - Air: 760F Concrete: 800F Truck No: 5013 Ticket No: 6337170 Air Content: 4.1 % Unit Weight (pet): NA Overall Placement Location: Inlet bottoms, Montebello Drive and walls, Station 2+75 Measured 5Y' (I ) 3.5 Sample Location: Inlet bottom and walls, same as above REPORT OF TESTS Cylinder Marked Set No. - - 1 1 Diameter (In) 5.99 Date Tested 09/10/2008 1 1 2 3 10/01/2008 10/01/2008 1 4 10/29/2008 56 ~E3 ~[g &E E;J DO D Type 1 Type 2 Type 3 Type 4 Type 5 Concrete Compressive Cylinder 6" x 12" Maximum Load (lb.) 112,610 Fracture Type Type5 Area (In") 28.18 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/LB) Page 1 of 2