CONCRETE, GROUT, AND MORTAR TESTS
LEITER OF TRANSMJIT AL
TO: City of Coppell
P.O. Box 9478
DATE: 10/19/2007
RE: Bethel Road - Coppell
Coppell, TX 75019
A TIN: Mr. Rick O'Dell
JOB NO.: 005061
PERMIT #:
LOCATION:
Bethel Road, CoppeJ1, TX
We are enclosing:
X Attached
X Materials Engineering Division Concrete Reports:
37
X For Your Use
l As Requested
cc: TISEO Paving ~ Robert Caudill
~~L
-~......- ...---
David A. ewis, P.E.
Principal Engineer
~
Siddharth Neekhra
Project Engineer
By:
. . Oc~19-2007 13:44
From-
9723920102
T-049 P.003/003 F-310
E
K~:~::t ,~~ ___ "-IIIR1
LL.~U~
ReS TCXlIll. LLP
49SO Keller Springs Road, Suite 480
Atldison. TX 75001
(972) 39;M222
(FAX) 392.0102
Concrete Cylinders Strength Report
Project: 5061 Set Designation: A
Cast Date: 09/21/2007
Design Strength: 3600 psi
Report No.: 37
Project:
Location:
Bethel Road - Coppell
Bethel Road. Cappell, TX
City of Coppell - Rick O'Dell
Client: City of Coppell - Kenneth M. Griffin,
Gen. Contr.:
Cone. Contr.:
Owner:
Arch.:
Struc. Eng.:
Placement Location: Box Culvert
Concrete Supplier; LMC
Mix Designation: 170]
Added Water: 10 Gals.
Truek No; ] 050
Mix Strength: 3600 psi
Time Added: 05:27PM
Ticket No: 7182542
Batch Time: 04:54PM
Unit Wt.:
FIELD TEST DA T A: Tested by: Yaw B. Boaitey
Temperature - Air: 92Q F
Time Sampled:05:40PM
Concrete: 900 F
Stump:5.00 in.
Air Content=4.00 % (P)
Sample Test Test Type DillIllCter Area Breaking Compr. Brk Break Review
No Date Age Cure Tn. Tn.2 Load,lbs Str.,psi Typ by by
36429 09/28/2007 7 Lab 4.00 12.56
36430 10/19/2007 28 Lab 4.00 12.56 59232 4710 SN
36431 1011912007 28 l.ab 4.00 12.56 61631 4900 SN
36432 11/1612007 56 Lab 4.00 12.56
:ia/r1Iftng in accotlIallCe IIIIlIl OIlW) ASTM C172, llllClIplll\al satI'flleC may IlaYe been taken tom the beginning 01 the load after a minimum dischlrge of approximately one cubic yard.
Cylinder JIlOlding and IallOraloty culfng law ASTM C31, eompteMl\'8 sII'llIlglh test and breall type law ASTM C39. slump iaw C143. air CDlltent law ASTM C113 (\I) Dr C231 (Pl.
tempel'l\Ure ~ ASTM C1064. and uril weight iaw ASTM C138. CylinderS nlllsl811 using unbonded caps law ASTM C1231 or are cappe<I using su~ur
mortlI' II1II C617. Break Types are cl~ed as: 1'ype 1.2.3.4.5. Dr 6 jaw C39-04a
FIELD CURING CONDITIONS:
Curing Box Insulated
X No Curing Box Heated
Remarks: culvet @ the intersection of Bethel
Rd.
Cooled
X Caps
lee
Other
Final Review By: