Loading...
ST9905-LR071019 ~ Oct-19-2007 13:44 F rom- 9723920102 T-049 P.002/003 F-310 ~l\i5i,!:',,'ur~'\'i.if,ilIl'= ECS TeXIIS, LLP E: 4950 Keller SJlri~ RDad. S~ite480 AddisOD, TIC 75001 (g72) 392-3222 (FAX)3!:12.ot02 1i!3:~ ;i ',III'\~ IM,."......m I""'..".,,,,;\,,,:,~ CONCRETE, GROUT, AND MORTAR TESTS LEITER OF TRANSMJIT AL TO: City of Coppell P.O. Box 9478 DATE: 10/19/2007 RE: Bethel Road - Coppell Coppell, TX 75019 A TIN: Mr. Rick O'Dell JOB NO.: 005061 PERMIT #: LOCATION: Bethel Road, CoppeJ1, TX We are enclosing: X Attached X Materials Engineering Division Concrete Reports: 37 X For Your Use l As Requested cc: TISEO Paving ~ Robert Caudill ~~L -~......- ...--- David A. ewis, P.E. Principal Engineer ~ Siddharth Neekhra Project Engineer By: . . Oc~19-2007 13:44 From- 9723920102 T-049 P.003/003 F-310 E K~:~::t ,~~ ___ "-IIIR1 LL.~U~ ReS TCXlIll. LLP 49SO Keller Springs Road, Suite 480 Atldison. TX 75001 (972) 39;M222 (FAX) 392.0102 Concrete Cylinders Strength Report Project: 5061 Set Designation: A Cast Date: 09/21/2007 Design Strength: 3600 psi Report No.: 37 Project: Location: Bethel Road - Coppell Bethel Road. Cappell, TX City of Coppell - Rick O'Dell Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: Owner: Arch.: Struc. Eng.: Placement Location: Box Culvert Concrete Supplier; LMC Mix Designation: 170] Added Water: 10 Gals. Truek No; ] 050 Mix Strength: 3600 psi Time Added: 05:27PM Ticket No: 7182542 Batch Time: 04:54PM Unit Wt.: FIELD TEST DA T A: Tested by: Yaw B. Boaitey Temperature - Air: 92Q F Time Sampled:05:40PM Concrete: 900 F Stump:5.00 in. Air Content=4.00 % (P) Sample Test Test Type DillIllCter Area Breaking Compr. Brk Break Review No Date Age Cure Tn. Tn.2 Load,lbs Str.,psi Typ by by 36429 09/28/2007 7 Lab 4.00 12.56 36430 10/19/2007 28 Lab 4.00 12.56 59232 4710 SN 36431 1011912007 28 l.ab 4.00 12.56 61631 4900 SN 36432 11/1612007 56 Lab 4.00 12.56 :ia/r1Iftng in accotlIallCe IIIIlIl OIlW) ASTM C172, llllClIplll\al satI'flleC may IlaYe been taken tom the beginning 01 the load after a minimum dischlrge of approximately one cubic yard. Cylinder JIlOlding and IallOraloty culfng law ASTM C31, eompteMl\'8 sII'llIlglh test and breall type law ASTM C39. slump iaw C143. air CDlltent law ASTM C113 (\I) Dr C231 (Pl. tempel'l\Ure ~ ASTM C1064. and uril weight iaw ASTM C138. CylinderS nlllsl811 using unbonded caps law ASTM C1231 or are cappe<I using su~ur mortlI' II1II C617. Break Types are cl~ed as: 1'ype 1.2.3.4.5. Dr 6 jaw C39-04a FIELD CURING CONDITIONS: Curing Box Insulated X No Curing Box Heated Remarks: culvet @ the intersection of Bethel Rd. Cooled X Caps lee Other Final Review By: f}~L SN Print Date: 10/1912007