ST9905-LR071016
Oct-1Q-2007 16:49
Frcm-
9723920102
T-026 P.002/003 F-274
~ii~~I1:1" ~ BeS TCXBSf LL1>
ms: 4950 Keller spriugs Road. Suitc480
AddilDll, TX 'SOOI
(972) 39203222
(FAX) 392.a1 02
i~ .~~ r-: 'II"";nh'''.A'Utt.II...il1r,;J
1iT"'\I~""""'rll'lI!!XA&
CONCRETE, GROUT, AND MORTAR TESTS
LETTER OF TRANSMITTAL
TO: City of Coppell
P.O. Box 9478
DATE: 10/1612007
RE: Bethel Road - Coppell
Coppell, TX 75019
A1TN: Mr. Rick O'Dell
JOB NO.: 005061
PERMIT #:
LOCATION:
Bethel Road, Coppell, TX
Weare enclosing:
X Anached
X Materials Engineering Division Concrete ReportS:
39
X For Your Use
X As Requested
CC: TISEO Paving - Robert Caudill
. .L.
id A. I.:ewis, pf.
Principal Engineer
~~a__.__.__._._._"." ..
Siddharth Neekhra .
Project Engineer
By:
Oct~16-2007 16:49
From-
9723920102
T-026 P.003/003 F-274
E ECSTexas,L1.P
4~ Kel1~ sprircs RofId, SUlle480
^ddison, TX 75001
(972) 392.3222
1iW"""""""-'.' (PAX)J92-0102
c;r:I:::..Il!Il dCU'lO
Project: 5061
Cast Date:
Design Strength:
Report No.:
Concrete Cylinders Strength Report
Set Designation: A
09/28/2007
4000 psi
39
Project: Bethel Road - Coppell
Location: Bethel Road, Coppell, TX
OWner: City of Coppell - Rick O'Dell Client:
Arch.: Gen. Contr.:
StrUc. Eng.: Cone. Contr.:
Placement Location: Box culvert at Bethel Road and Freeport
City of Coppell - Kenneth M. Griffin,
Concrete Supplier: LMC
Mix Designation: 1851
Added Water:
Truck No: 944
Mix. Strength: 4000 psi
Time Added:
Ticket No: 6313455
Batch Time: 01:46PM
Uoit Wt.:
Time Sampled:03:05PM
Concrete: 950 F
FIELD TEST DATA. Tested by:David L. Hunt
Temperature - Air: 920 F
Sample Test Test TYpe Diamollel' Area
No Date Age Core In. In.2
36544 10/0512007 7 Lab 4.00 12.56
36545 10/26/2007 28 Lab 4.00 12.56
36546 10/26/2007 28 Lab 4.00 12.56
36547 11/2312007 56 Lab 4.00 12.56
36548 1010112007 3 Field 4.00 12.56 41428 3300 SN
~1Illg n accordllnc8 ) C172. ~ IIIaI ~ may have been '"" IfIe beginni~ lhe toacI after a rmmum d l1Ie ol apPfOllim one cubic; Ylrd.
CylInder mddiIIG IIIdl8llolatOrY curilg iawASTM C31, CQlnil8Sllt/es1reng1h _1IId bnlllk ~ IaN ASTM C39, Sllll!lP IawC143, air c;ontel'lt law ASTMC173 M orC231 (Pl.
~ iaw ASTM C1084, allll urit we~nt law ASTM C138. O/llndel1 are teSt8d usitg unlxlnded caps laW ASTM e1231 or are capped U$ing $U\pIl1l'
mDI1Ir Mlw 0617. BreIk TYllII are c:Iaiified as: Type 1,2,3,4. S, or tI iaw C39-04a
FmLD CURING CONDITIONS-=.
Curing Box
X No Curing Box
Remarks:
Breaking
Load,lbs
55776
COtt1pt:.
Str.,psi
4440
Insulated
Heated
Cooled
X Caps
Slump:4.50 in.
Air Content:3.20 % (V)
Brk Break Review
Typ by by
SN
lee
Other
Final Review By:
SN
Print Date:
10/1612007