ST9905-LR080227 ... ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 CONCRETE, GROUT, AND MORTAR TESTS LETTER OF TRANSMITTAL TI!XA8 TO: City ofCoppell P.O. Box 9478 DA TE: 02/27/2008 RE: Bethel Road - Coppell Coppell, TX 75019 A TTN: Mr. Rick O'Dell PERMIT #: JOB NO.: 005061 LOCATION: Bethel Road, Coppell, TX Weare enclosing: X Attached X Materials Engineering Division Concrete Reports: 95,96,98,99, 110, III x X For Your Use As Requested CC: TISEO Paving - Robert Caudill City of Coppell - Rick O'Dell ;/a/ q;{: ~id A. Lewis, PR Principal Engineer ~((~ Eric L. Branch, C.E.T. Project Manager By: Concrete Cylinders Strength Report Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX City of Coppell - Rick O'Dell Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 01/28/2008 4500 psi 95 Owner: Arch.: Struc. Eng.: Placement Location: Curb and gutter, Client: Gen. Contr.: Conc. Contr.: storm drain at station 36 + 52.12 City of Coppell - Kenneth M. Griffin, Concrete Supplier: Southern Star Mix Designation: 9361 Added Water: Truck No: 86 Mix Strength: 4500 psi Time Added: Ticket No: 1755538 Batch Time: 02:10PM Unit Wt.: FIELD TEST DATA: Tested by:Michael J. Cochran Temperature - Air: 620 F Time Sampled:02:45PM Concrete: 650 F Slump:3.25 in. Air Content:3.60 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 38588 02/04/2008 7 Lab 4.00 12.56 57504 4580 ELB1 38589 02/25/2008 28 Lab 4.00 12.56 73760 5870 2 ELB1 38590 02/25/2008 28 Lab 4.00 12.56 75808 6030 2 ELB1 38591 03/24/2008 56 Lab 4.00 12.56 . . . . SampHng In accordance W111l (law) ASTM C172, except lIlat samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive streng III test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: I2J~ L r ELBI Print Date: 02/27/2008 Project: Location: Bethel Road - Coppell Bethel Road, Coppell, TX Concrete Cylinders Strength Report Project: 5061 Set Designation: B Cast Date: 01/29/2008 Design Strength: 3000 psi Report No.: 96 ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 ,1IXAa Owner: City of Coppell - Rick O'Dell Client: City of Coppell - Kenneth M. Griffin, Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Paving, approach 400' West of Freeport Parkway. Concrete Supplier: Southern Star Mix Designation: 7782 Added Water: Truck No: 923 Mix Strength: 3600 pSI Time Added: Ticket No: 1188824 Batch Time: 11 :55AM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 600 F Time Sampled:12:23PM Concrete: 700 F Slump:4.00 in. Air Content:3.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 38628 02/05/2008 7 Lab 4.00 12.56 55372 4410 ELBl 38629 02/26/2008 28 Lab 4.00 12.56 85024 6770 4 ELBl 38630 02/26/2008 28 Lab 4.00 12.56 76960 6120 5 ELBl 38631 03/25/2008 56 Lab 4.00 12.56 Sampting in accordance willi (iaw) ASTM C172, excepllhat samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM cm M or C231 (P), temperature iaw ASTM Cl064, and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar jaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 law C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: aJd r ELBl Print Date: 02/27/2008 Concrete Cylinders Strength Report ~ ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 ..AM Project : 5061 Cast Date: Design Strength: Report No.: Set Designation: C 01/29/2008 4000 psi 98 Project: Bethel Road - Coppell Location: Bethel Road, Coppell, TX Owner: City of Coppell - Rick O'Dell Client: Arch.: Gen. Contr.: Struc. Eng.: Cone. Contr.: Placement Location: Inlet top, 50 ft west of Royal Lane on Bethel Road City of Coppell - Kenneth M. Griffin, Concrete Supplier: Southern Star Mix Designation: 9361 Added Water: Truck No: 84 Mix Strength: 4500 pSI Time Added: Ticket No: 1189092 Batch Time: 02:00PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 530 F Time Sampled:02:35PM Concrete: 630 F Slump: 5.00 in. Air Content:2.80 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 38636 02/05/2008 7 Lab 4.00 12.56 54432 4330 ELBl 38637 02/26/2008 28 Lab 4.00 12.56 81920 6520 4 ELBl 38638 02/26/2008 28 Lab 4.00 12.56 76544 6090 4 ELBl 38639 03/25/2008 56 Lab 4.00 12.56 . . . . Sampling III accordance With (law) ASTM C172. except that samples may have been taken from the beginning of the load after a minimum dIScharge of approximately one cubiC yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 M or C231 (P), temperature iaw ASTM C1064. and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1,2.3.4,5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other FffiID Review By: t/ q ;:{. . ELBl Print Date: 02/27/2008 Concrete Cylinders Strength Report Owner: Arch.: Struc. Eng.: Bethel Road - Coppell Bethel Road, Coppell, TX City of Coppell - Rick O'Dell Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: D 01/29/2008 3600 psi 99 Project: Location: Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Conc. Contr.: Placement Location: Box Culvert Walls, box culverts 300 ft west of Freeport on Bethel Concrete Supplier: Southern Star Mix Designation: 1851 Added Water: Truck No: 978 Mix Strength: 3600 pSi Time Added: Ticket No: 324727 Batch Time: 04:07PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 500 F Time Sampled:04:34PM Concrete: 560 F Slump: 5.00 in. Air Content:} .50 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 38640 02/05/2008 7 Lab 4.00 12.56 43488 3460 ELB1 38641 02/26/2008 28 Lab 4.00 12.56 76992 6130 4 ELB1 38642 02/26/2008 28 Lab 4.00 12.56 65472 5210 5 ELB1 38643 03/25/2008 56 Lab 4.00 12.56 . . . . Sampling In accordance with (laW) ASTM C172. except that samples may have been taken from the beginning of the load after a minimum discharge of approXImately one cubiC yard. Cylinder molding and laboratory curing law ASTM C31. compressive strength test and brelk type iaw ASTM C39. slump iaw C143. air content iaw ASTM C173 (II) or C231 (Pl. temperature jaw ASTM C1064. and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1. 2. 3. 4, 5, or 6 jaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other FinID Review By: fi.; q ;i. o. ELB1 Print Date: 02/27/2008 Owner: Arch.: Struc. Eng.: Bethel Road - Coppell Bethel Road, Coppell, TX City of Coppell - Rick O'Dell Concrete Cylinders Strength Report Project: 5061 Set Designation: A Cast Date: 02/1812008 Design Strength: 4000 psi Report No.: 110 ~ ECS Texas, LLP E 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 Project: Location: Client: City of Coppell - Kenneth M. Griffin, Gen. Contr.: Cone. Contr.: Placement Location: Elevated slab box culvert roof, sampled 10' S x 10' E from NW comer Concrete Supplier: LMC Mix Designation: 1851 Added Water: 8 Gals. Truck No: 7003 Mix Strength: 4000 pSI Time Added: Ticket No: 7188587 Batch Time: 01:27PM Unit Wt.: FIELD TEST DATA: Tested by: Michael 1. Cochran Temperature - Air: 560 F Time Sampled:02:00PM Concrete: 630 F Slump:5.75 in. Air Content:4.80 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39026 02/25/2008 7 Lab 4.00 12.56 67264 5350 2 ELBl 39027 03/17/2008 28 Lab 4.00 12.56 39028 03/17/2008 28 Lab 4.00 12.56 39029 04/14/2008 56 Lab 4.00 12.56 . . . . Samplng in accordance WIlli (law) ASTM C172. excepllllat samples may have been taken from lIIe beginning of lIIe load after a minimum dIScharge of approximately one cubiC yard. Cylinder molding and laboralory curing iaw ASTM C31. compressive strenglll test and break type iaw ASTM C39. slump iaw C143. air content iaw ASTM C173 M or C231 (P). temperature iaw ASTM C1064. and unit weight iaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw Ca17. Break Types are classified as: Type 1, 2, 3. 4. 5. or a iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 02/27/2008 Concrete Cylinders Strength Report '" ECS Texas, LLP ~ 4950 Keller Springs Road, Suite 480 Addison, TX 75001 (972) 392-3222 (FAX) 392-0102 Project: 5061 Cast Date: Design Strength: Report No.: Set Designation: A 02/19/2008 3600 psi 111 Project: Bethel Road - Coppell Location: Bethel Road, Coppell, TX Owner: City of Coppell - Rick O'Dell Client: Arch.: Gen. Contr.: Struc. Eng.: Conc. Contr.: Placement Location: Approach to warehouse buildings, 1000' W of Royal on Bethal Rd. City of Coppell - Kenneth M. Griffin, Concrete Supplier: Southern Star Mix Designation: 7795 Added Water: Truck No: 31 Mix Strength: 3600 psi Time Added: Ticket No: 1204377 Batch Time: 12:25PM Unit Wt.: FIELD TEST DATA: Tested by: Jonathan E. Steiner Temperature - Air: 700 F Time Sampled:O 1 :30PM Concrete: 740 F Slump: 5.00 in. Air Content=4.00 % (P) Sample Test Test Type Diameter Area Breaking Compr. Brk Break Review No Date Age Cure In. In.2 Load,lbs Str.,psi Typ by by 39034 02/26/2008 7 Lab 4.00 12.56 77056 6130 4 ELBl 39035 03/18/2008 28 Lab 4.00 12.56 39036 03/18/2008 28 Lab 4.00 12.56 39037 04/15/2008 56 Lab 4.00 12.56 . . . . Samp6ng m accordance with (law) ASTM C172, exceptlhat samples may have been Iaken from the beginning of the load after a minimum dIScharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump jaw C143, air content law ASTM C173 M or C231 (P), temperature jaw ASTM C1064, and unit weight jaw ASTM C138. Cylinders are tested using unbonded caps iaw ASTM C1231 or are capped using sulphur mortar iaw C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39-04a FIELD CURING CONDITIONS: Curing Box X No Curing Box Remarks: Insulated Heated Cooled X Caps Ice Other Final Review By: ELBl Print Date: 02/27/2008