Loading...
Chicken Express-LR080912 (2) REPORT OF CONCRETE COMPRESSION TEST"----- ~ PROJECT~ CHICKEN EXPRESS / COPPELL, TX l- ~~ ., Information ~~. .To Build On Engineering. ConsultIng. Testing TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: September 12, 2008 PSI REPORT NO.: 341-80040-40 RESTAURANT FIELD DATA: LOCATION OF PLACEMENT Entrance Off of Denton Tap Road Entrance Ramp DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY September 12, 2008 02:00 pm 3 3/4 5.1 93 of 90 September 13, 2008 PSI\Gabriel Ortiz Gateway Concrete SUPPliER DEliVERY TICKET NO.rrRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Gateway Concrete 51267 605 Sand Sand Color (Red) NOTE' APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP' C143' AIR CONTENT' C231 (EXCLUDING SEe 6)' TEMPERATURE' C1064' CYLINDERS' C31 /cXCLUDtNG SEe 1012). SAMPLING' C172 COMPRESSION TEST RESULTS ASTM C39; C1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK. LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) (PSI) ASTM C39 2114 A 7 09/19/08 93470 6.00 28.27 3310 Type 2 2114 B 28 10/10/08 2114 C 28 10/10/08 2114 D H HOLD SPECIFICATIONS 28 4500 REMARKS: ~ Cylinders made by PSI representative. Cylinders picked up by PSI ~ representative. Test resulls comply with a,clicable specifications. Cylinders made by Architect's or - "'"~'W, .0."""'''' dJ ,,,..,," "''''2'':J TECHNICIAN, Wi~ller r I!I.D..-- m~~ ~,~~~:~~,:,~~o~, ,:~,:~~",,~d~ L~~ f,,~~m ~'~m REPORTS MAY NOT BE REPROOUCED EXCEPT IN FULL wiTHOUT wRITTEN PERMISSION BY PROFE~ SERVICE INDUSTRIES. INC Test results do not comply WIlh applicable speCifications. Respectfully submitted, Professional Service Industries, Inc. PSI A.201J..4N F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas. TX 75237. Phone 214/330-9211. Fax 214/467-0031 i....s.' Information ~..,. .To Build On Engineering. Consulting. Testing REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: September 12, 2008 PSI REPORT NO.: 341-80040-42 FIELD DATA: LOCATION OF PLACEMENT PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX Sidewalk Off of Beltline Road Sidewalk Off of Beltline Road DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY September 12, 2008 03:30 pm 4 1/2 5.3 90 OF 91 September 13, 2008 PSI\Gabriel Ortiz Gateway Concrete SUPPLIER DELIVERY TICKET NO.rrRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Gateway Concrete 51270 605 Sand Rock None NOTE: APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP' C143" AIR CONTENT- C2311EXCLUDtNG SEC. 61' TEMPERATURE- Cl064' CYLINDERS' C31/C:XCLUDtNG SEe 1012)" SAMPLING- C172 COMPRESSION TEST RESULTS ASTM C39; C1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK. LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (SO. IN.) (PSI) ASTM C39 2115 A 7 09/19/08 92870 6.00 28.27 3290 Type 2 2115 B 28 10/10/08 2115 C 28 10/10/08 SPECIFICATIONS 28 4500 REMARKS: ~ Cylinders made by PSI representative. Cylinders picked up by PSI ~ representative. Cylinders made by Architect's or Contracto~s representative. Test results comply with applicable specifications. Cylinders delivered to PSI laboratory. Test results do not comply w1th applicable specifications. TECHNICIAN: William Miller cc: Hynes; Davis; Stone Respectfully submitted, Professional Service Industries, Inc. THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT. REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC. PSI A.200.4N F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031