Chicken Express-LR080912 (2)
REPORT OF CONCRETE COMPRESSION TEST"-----
~
PROJECT~ CHICKEN EXPRESS
/ COPPELL, TX
l- ~~ ., Information
~~. .To Build On
Engineering. ConsultIng. Testing
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
DATE:
September 12, 2008
PSI REPORT NO.: 341-80040-40
RESTAURANT
FIELD DATA:
LOCATION OF PLACEMENT
Entrance Off of Denton Tap Road
Entrance Ramp
DATE PLACED
TIME
SLUMP, IN.
AIR CONTENT, %
AIR TEMPERATURE, of
CONCRETE TEMPERATURE
DATE RECEIVED IN LAB
FIELD DATA SUBMITTED BY
MIX DATA SUBMITTED BY
September 12, 2008
02:00 pm
3 3/4
5.1
93
of 90
September 13, 2008
PSI\Gabriel Ortiz
Gateway Concrete
SUPPliER
DEliVERY TICKET NO.rrRUCK NO.
MIX NUMBER AND PROPORTIONS
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
Gateway Concrete
51267
605
Sand
Sand
Color (Red)
NOTE' APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP' C143' AIR CONTENT' C231 (EXCLUDING SEe 6)' TEMPERATURE' C1064' CYLINDERS' C31 /cXCLUDtNG SEe 1012). SAMPLING' C172
COMPRESSION TEST RESULTS
ASTM C39; C1231
SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK.
LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN
NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) (PSI) ASTM C39
2114 A 7 09/19/08 93470 6.00 28.27 3310 Type 2
2114 B 28 10/10/08
2114 C 28 10/10/08
2114 D H HOLD
SPECIFICATIONS
28 4500
REMARKS: ~ Cylinders made by PSI representative.
Cylinders picked up by PSI
~ representative.
Test resulls comply with a,clicable
specifications.
Cylinders made by Architect's or
- "'"~'W, .0."""'''' dJ ,,,..,," "''''2'':J
TECHNICIAN, Wi~ller r I!I.D..--
m~~ ~,~~~:~~,:,~~o~, ,:~,:~~",,~d~ L~~ f,,~~m ~'~m
REPORTS MAY NOT BE REPROOUCED EXCEPT IN FULL wiTHOUT wRITTEN PERMISSION BY PROFE~ SERVICE INDUSTRIES. INC
Test results do not comply WIlh
applicable speCifications.
Respectfully submitted,
Professional Service Industries, Inc.
PSI A.201J..4N F
Professional Service Industries, Inc.. 4087 Shilling Way. Dallas. TX 75237. Phone 214/330-9211. Fax 214/467-0031
i....s.' Information
~..,. .To Build On
Engineering. Consulting. Testing
REPORT OF CONCRETE COMPRESSION TEST
TESTED FOR:
RANDY HYNES
RANDY HYNES GENERAL CONTRACTOR
101 TRINITY VIEW RD
WEATHERFORD, TX 76087
DATE:
September 12, 2008
PSI REPORT NO.: 341-80040-42
FIELD DATA:
LOCATION OF PLACEMENT
PROJECT: CHICKEN EXPRESS RESTAURANT
COPPELL, TX
Sidewalk Off of Beltline Road
Sidewalk Off of Beltline Road
DATE PLACED
TIME
SLUMP, IN.
AIR CONTENT, %
AIR TEMPERATURE, of
CONCRETE TEMPERATURE
DATE RECEIVED IN LAB
FIELD DATA SUBMITTED BY
MIX DATA SUBMITTED BY
September 12, 2008
03:30 pm
4 1/2
5.3
90
OF 91
September 13, 2008
PSI\Gabriel Ortiz
Gateway Concrete
SUPPLIER
DELIVERY TICKET NO.rrRUCK NO.
MIX NUMBER AND PROPORTIONS
CEMENT
WATER
FINE AGGREGATE
COARSE AGGREGATE
ADMIXTURE
Gateway Concrete
51270
605
Sand
Rock
None
NOTE: APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP' C143" AIR CONTENT- C2311EXCLUDtNG SEC. 61' TEMPERATURE- Cl064' CYLINDERS' C31/C:XCLUDtNG SEe 1012)" SAMPLING- C172
COMPRESSION TEST RESULTS
ASTM C39; C1231
SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK.
LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN
NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (SO. IN.) (PSI) ASTM C39
2115 A 7 09/19/08 92870 6.00 28.27 3290 Type 2
2115 B 28 10/10/08
2115 C 28 10/10/08
SPECIFICATIONS
28 4500
REMARKS: ~ Cylinders made by PSI representative.
Cylinders picked up by PSI
~ representative.
Cylinders made by Architect's or
Contracto~s representative.
Test results comply with applicable
specifications.
Cylinders delivered to PSI laboratory.
Test results do not comply w1th
applicable specifications.
TECHNICIAN:
William Miller
cc: Hynes; Davis; Stone
Respectfully submitted,
Professional Service Industries, Inc.
THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT.
REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL. WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES. INC.
PSI A.200.4N F
Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211 . Fax 214/467-0031