Kountry Donuts-LR080924 Rone Engineering . Client: Mrs. Shawna Kim 1403 Savoy Ct Colleyville, TX 76034 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Report No.: 333223 Project No.: 0814449 Date of Service: 09/16/2008 Report Date: 09/24/2008 Project: Kountry Donuts Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Cooper General Contractors Concrete Supplier: Nelson Brothers Plant: 1 Specification Requirements Strength: 3,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): NA Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: PD35 Placement Date: 09/16/2008 Weather Conditions: Clear, sunny Time Sampled: 03:10pm Batch time: 02:00pm Temperature - Air: 930F Concrete: 890F Truck No: 106 Ticl<et No: 104868 Air Content: NA t (pet): NA Overall Placement Locatio See report #333222 Measured Slump (inches) 5.75 Sample Location: Same as above REPORT OF TESTS Rone Engineering See Report 333222 for technician time~~ Report Distribution: Orig: Mrs. Shawna Kim (Colleyville, TX) (1-cc copy) 1-ec Cooper General Contractors Attn: Mr. Bill Cawley .. . . 1-ec R~ne Project Manager Attn: Mr. K. Scott Watson AET K. Scott Watson, AET 1-ec City of Coppell Attn: Mr. Lee Stone Project Manager 1-ec City of Coppell Attn: Mr. Larry Davis Cylinder Marked Date Age Set No. Tested (days) 1 1 09/23/2008 7 1 2 10/14/2008 28 1 3 10/14/2008 28 4 11/11/2008 56 Diameter (In) 6.00 ~E3 ~Q] [ill] ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Technician: Homer Gonzalez Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 87,120 Compressive Strength (psi) 3,080 Area (ln2) 28.27 Fracture Type Type2 Type 6 ;'lie /c//~;%J~ t! ~ LIMITATIONS: The test resu~s presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (ADW/CL) Page 1 of 1