Bethel BP-SP081003 r.. t' SUBMITTAL BETHEL BUSINESS PARK COPPELL,TX, PCI Construction P.O. Box 2967 . Mckinney, Tx 75070 Phone: (972) 562-2762 Fax: (972) 562-29~4 -,\ H FERGUSON@ ." Waterworks a WOLSELEY company 10077 W U Diversity Drive ~c~DDey,Texas75Q71 P 972-434-2600 F 972-434-2612 Prepared by: Courtney Runyon Ferguson Waterworks Courtney.runyon@ferguson.com ,,---.. , '..... 'jO {O~ !D~ Table Of Contents ~ -><> SANITARY SEWER :::PlPE::: DSDR35PX20 SDR351PVC GJ SEWER PIPE DIAMONDPLA ::: FlmNGS ::: CERT FOR TRENCH TO CERT FOR TRENCH TOUGH SWR FIT MUL TIFIT ::: CLEAN OUTS ::: SANCLEANOUT SAN CO CASTING # 339 ACCUCAST ::: RING AND COVERS ::: B40024 SAN SWR R&C BASS&HAYS FOUNDRY <><> POTABLE WATER <><> ::: PIPE::: CERT PVC C900 CERTIFICATION PVC C900 D1AMONDPLA CERT FOR NO HUB P& CERTIFICATION FOR NO HUB P & F CHARLOTTE ::: FITTINGS ::: CERT 01 FITTING WA CERTIFICATION 01 FITTING FOR WATER TYLER SPVC4008 4000 SER PVC STARGRIP REST STAR VALVES ::: AFC2508FMLAOL RW OL GATE VALVE U AFC AVBX126 #107 VLV BX SWR WI LID ACCUCAST ..:FIRE::: WWB67LAOLS 5-114 VO WB67 HYD 5FT BURY OL UA WATEROUS A069116 FLGXCIOD SS IN-BUILD RSR AMES FIRE AND WATERWORKS NKW900WU 6 CI UL FM WAF CHK VLV NIBCO R21133LU 2-1/2X6 90 SIA CONN DIXON ::: SERVICE MATERIAL ::: CERT COPPER TUBE CERTIFICATION FOR COPPER TUBE MUELLER MBR2B1314CCK 12X2 CC BRZ DBL STRAP SADDLE MUELLER MH15000K 2 CC X FLR CORP ST MUELLER MB25166K 2 FLR X MTR ANG BV WI LW MUELLER MB2423K12 2X12 COP MTR SETTER MUELLER BH55A1S 28X18 GALV MTR BX BASS&HAYS FOUNDRY SCH 40 PVC PIPE PRECAST VAULTS 8" DETECTOR CHECK VAULT RCP Pipe TOUNGE AND GROOVE RCP PIPE PRECAST STRUCTURES 4' JUNSTION BOX 10' CURB INLET 2' X 2' GRATE INLET 4 5 6 8 9 ~ 10 11 12 13 14 15 16 18 19 20 ----- 21 25 26 30 31 32 36 37 38 39 40 41 42 44 45 46 47 49 50 51 52 53 r--- <><> SANITARY SEWER <><> ~ FERGUSONe 4 --- ::: PIPE::: DIAMONDPLA DSDR35PX20 SDR35 PVC GJ SEWER PIPE ------ ~ FERGUSON" 5 ::: PIPE ::: SPECIFICATIONS DATA PRODUCT DESCRIPTION Diamond gravity sewer pipe 4 inches through 27 Inches shall be made of compounds conforming to material requirements of ASTM 0-3034 & F679 in accordance with ASTM D-1784. Diamond PVC Sewer Pipe meets all the dimensional, chemical and physical requirements as outlined in ASTM D-3034 or F-679. . PHYSICAL PROPERTIES PVC Pipe Stiffness SDR E = 400,000 psi E = 500,000 psi 41 28 35 35 46 57 26 115 144 The pipe sizes 4 Inches through 27 Inches are made with an Integral bell to utilize the gasket for sealing which meets specifications defined in ASTM F-477. CHEMICAL RESISTANCE ASTM TEST Each male end shall be beveled to facilitate join- ing and reference marked to insure proper Inser- tion depth. Diamond furnished lubricant is to be used in the joining process. 93.0% Sulfuric Acid, 14 Days Flotation at 55 + or -20 C Change In Weight, % Change In Flex Strength, % ASTM Oil No.3, 30 Day Immersion at 230 C Change in Weight, % D 543 -0.1 + 5.0 -25.0 to + 5.0 -1.0 to 1.0 03034 Pipe Acceptable Materials Short Form Specification for Diemon PVC Sewer Pipe Type PSM. SDR 26 or 35 133648 or 124548 or 12454C or 12364C Example of Properties Diamond PVC Sewer Pipe shall be made of compounds conforming to ASTM 01784 in accordance with the material requirements of ASTM 03034. Diamond PVC Sewer Pipe must meet all of the dimensional. chemical and physical requirements as outlined in ASTM 03034 and ASTM F679. Diamond PVC Sewer Pipe shall be installed according to the requirements of ASTM 02321, Uni-Bell UN I- PUB 6, "and the manufacturer's requirements." PROPERTIES OF PVC 13364.8 Property ASTM Test D 792 o 638 o 638 o 256 Specific Gravity Tensile Strength, psi Tensile Modulus, psi IZOO Impact Strength, ft., Ib./in. ~ FERGUSON~ ~ Minimum 1.47 6,000 440,000 .65 6 ~, Diamond ASTM 0.3034 & F679 PVC Sewer Pipe Approximate Coupler Dimensions r A r I I I I r · I I c Size 4 6 8 10 12 15 18 21 24 27 A 0.0. Gasket Race 5.110 7.372 9.873 12.115 14.241 17 .180 21.500 25.000 28.000 33.000 r- C Socket Depth 3.250 5.250 5.550 6.250 6.250 6.750 8.500 8.750 9.500 13.000 Diamond PVC Sewer Pipe coupler meets or ex- ceeds the requirements of ASTM 0.3212. 0.3034 Size 0.0. 4. 4.215 6 6.275 8 8.400 10 10.500 12 12.500 15 15.300 Pipe Dimensions Minimum Wall Thickness SDR.26 SDR.35 .162 .120 .241 .180 .323 .240 .404 .300 .481 .360 .588 .437 F679 PIPE DIMENSIONS & WALL THICKNESS 18 18.701 .719 .499 21 22.047 .588 24 24.803 .661 27 27.953 .745 IDENTIFICATION Diamond PVC Sewer Pipe shall be marked at specified intervals with the following data: r- 1. Diamond 2. Nominal Pipe Size 3. PVC Cell Classification 4. SDR 35 or SDR 26 or PS46 5.PSM 6. ASTM 03034 or ASTM F679 7. Extrusion Code 1/97 Contact Diamond Plastics Corporation lor currentlnlormalion. ~ FERGUSON~ ::: PIPE ::: Diamond ASTM 03034 PSM Gravity Sewer Pipe .'Vulcan Gasket Specifications ~ 1. The retaining ring holds the sealing ring in position during transport and for pipe assembly. 2. Chevron seal for added pressure sealing capacity. 3. Compression seal. provides seal under vacuum. 4. Wiper beads to clean spigot end. Diamond ASTM 03034 PSM Gravity Sewer Pipe Rieber Gasketed Joint Dimensions STOP -, ...."" DeliA. 0.0.) TL t t l..- A MUtD. L 0.0. Rleber a.ak.' Nominal A B D Pipe Insert Socket Diameter Size (Min.) (Min.) (Max.) 4" 4 4 5/8 5 1/4 6" 4 4 3/4 7 1/2 8" 5 6 118 9 7/8 10" 6 6 3/4 12 3/8 12 " 6 7 1/4 14 5/8 15" 6 6 3/4 17 3/4 "Joint system varies with product size and plant of manufacture. These are not engineered drawings and actual product may vary from them. Tolerances of Product Standards are applicable to nominal dimensions. General dimensions of diagrams are furnished to indicate approximate profile scheme only. 7 ~.----- ::: FITTINGS ::: MUL TIFIT CERT FOR TRENCH TO CERT FOR TRENCH TOUGH SWR FIT ---- r-- ~ FERGUSON" 8 ------ \, ~ . TRENCH TOUGHTM SDR35 GASKETED SEWER FITTINGS ::: FITTINGS ::: ~ SHORT FORM SPECS FOR TRENCH TOUGH'rM SEWER FITTINGS All Gasketed Sewer Fittings 4' through 15' shall be molded and comply with ASTM F1336 and 03034 standards. All fittings shall be manufactured from a high molecular weight compound having a minimum cell classification of 12454 or 13343 per ASTM 01784. All molded Wyes, T-Wyes and Tees must be a minimum of a SDR26 thickness where the branch connects to the body of the fitting. In addition, all outlets 4' through 6' service branches and bells must have a minimum of a SDR26 thickness. Materials used for gaskets must conform to the requirements of ASTM F4n or F913. All fittings must be manufactured with a locked-in gasket having a durometer rating of 45. These fittings must be third party certified to CSA B182.1 and/or CSA B182.2. Approved product: Multi Trench Tough SDR35 Sewer Fitting MULTI FITTINGS Engineered Tough- TRENCH TOUGWM SDR35 FABRICATED GASKETED SEWER FITTINGS All fabricated Gasketed Sewer Fittings 18' through 48' shall be made from segments of third party certified SDR35 pipe that exceeds the requirements of ASTM F679. The fittings shall consist of butt fused or welded pipe and solvent cemented service branches. All 4' through 6' service branches must be a minimum of SDR26 wall thickness. The fittings must conform to ASTM F1336,and F679 standards. All fittings shall be third party certified to CSA B182.1 and/or CSA B182.2 Approved product: Multi Trench Tough SDR35 Sewer Fitting Multi Trench Tough SDR35 Gasketed Sewer Fittings meet these standards: 4~1~ ~. @ ASTM F1336, F679 &03034 CSA 8182 1 IAPMO CSA 8182 2 FIle Number.1S7S .---.. TRENCH TOUGWM SDR26 HEAVY WALL SEWER FITTINGS All heavy wall SDR26 gasketed sewer fittings shall conform to ASTM F1336 and 03034 and shall be manufactured from a high molecular weight compound having a minimum cell classification of 12454 or 13343 as prescribed In ASTM 01784. All molded Wyes, T-Wyes and Tees must be a minimum of a SDR24 thickness for body of the fitting. In addition, all outlets 4' through 6' service branches, bells and bodies must have a minimum of a SDR24 thickness. Materials used for gaskets must conform to the requirements of ASTM F913 or ASTM F4n. All fittings must have a locked-In grey color coded gasket Approved product: Multi Trench Tough SDR26 Heavy Wall Sewer Fitting 4~1~ Multi Trench Tough SDR26 Heavy Wall Sewer Fittings meet these standards: ASTM F1336 ASTM D3034 TRENCH TOUGWM ClOD SEWER FITTINGS FOR C900 PIPE 4' to 8' ClOD gasketed sewer tees, couplings, elbows, plugs and reducers shall conform to AWWA C907 and be third party certified to CSA B137.2. They shall be UL listed and FM approved. All other configurations must have a minimum DR18 wall thickness. DR18 fittings shall be made from a compound with a minimum cell classification of 12454 per ASTM 01784. The compound must have a minimum Hydrostatic Design Basis.of 4,000 psi and must be listed with the National Sanitation Foundation. 'Fabricated ClOD fittings shall be made from segments of DR18 AWWA C900 or C905 pipe bonded together and over-wrapped with fibreglass-reinforced polyester. The pipe stock used to manufacture the fittings must be third party certified to CSA B137.3 and conform to AWWA C900lC905. Approved product: Multi Trench Tough ClOD Sewer Fitting Multi Trench Tough ClOD Sewer Fittings meet these standards: ~ NSF.61 ~. .-. AWNA c007 Compound flaled by CSA 8137.2 4' to 8' Nabollll Sanotation Fo.ndahon 4'10 8' lor potable wallr uNlce 'Thl&dounol_lorlllcont_ Soo__. ~ FERGUSON~ 9 ::: CLEAN OUTS ::: ACCUCAST SANCLEANOUT SAN CO CASTING # 339 ---- ~ FERGUSON~ 10 I G -=26- I IO! -1 1 # 339 San' ltary Cl B eanout ASE 92 Boot LID 8 lbs. SET 100 lbs. lbs. ~, ::: RING AND COVERS ::: 8ASS&HAYS FOUNDRY 840024 SAN SWR R&C ..---. ~ FERGUSON9 12 r~ :0 Z (;") (f) ~ -; o z , T~~"'T1 ~(,olr-l~ I-.:l ,......, m-,tn ,......,+ (bN '-J ~~, ~ -' m ~ 3 03 en 0>'-. 0 I 3:;;:3 = 3-to. 30 ~ If/~~l1 ~1' 1- I .. Irh m~ VI....>. 3, 31\) L....I = ,--, (OUl 3~ 3 I L.......l I /--- ,......, - ()1 1"-'01 3 = 3 ........ C"'TJ(,") ~ z:;tlo =:j:P-< s: ""'D .. :ii:: rr1 .t:.[!1?;:! );> 0 OJ 0 ^ -' I I (}IN"">' ~ 1'\)(0 ~ Z ,{]I 0 0 I'T'I :0 OJEii, 0 0 tn u:J I 0 I\) -,UlU) ~ (J) m (0-, c -; o:.oOCC> ;JJ ):>- AN(b ):! r r:::;N 1O",:r:- ....>.-' LQIC 0 3 tH rrI 3~ L::..Jm ~ r-- o o < m :0 (f) ~ -; o z ,--, OJ I\) .....t:. o I 3 0 ~CJ1 -'. ~:t> 3 . L....I ,......,1-> -.....J 3~ 3....>. ........ 0> (;1'-' .j:.. 3 -' 3'1:3 L.....J I ~....>. 00 3 '-J 3~ L.....J - OJ 00 T1~ 00 O~ << m_ Ilm ~ fg-' ~ ~ Wi>- (/) : I'T'I Ot;i "N r~ c3 ~ 8 fTI ~ Z G) \ -''l ::u- ~ I'T'I co 0-' -' - ~Vl ~ (/)i>- ~.... ~to;N ~3 "t-J'Ri. .3 U1 C:o; Nr {1.2,. 3 - I 321 , '--' z 9 ;:0 G) fTI )> I ::::ll DO Z r G1 fTI ,......, 01 31-> 3 H L....I ".r--. <><> POTABLE WATER <><> ~ FERGUSON~ 14 ::: PIPE ::: DIAMONDPLA CERT PVC C900 CERTIFICATION PVC C900 CHARLOTTE CERT FOR NO HUB P& CERTIFICATION FOR NO HUB P & F ~ FERGUSON~ 15 --- ::: PIPE ::: 'I~ ~ .,,' > l.\i'):~ DIAMOND C900 SPECIFICATION DATA' ,'J ,t',;',;, '<L\'*;,:,~'?(;y PVCPipej(}/" fhe 21't Cel1(lll)irt>,1 Product DeScription: Diamond (C900) PVCPipe (4" through 12" is made of 12454 compound per ASTM D1784, in accordance with the dimensional. chemical. and physical requirements of AWWA C900. Diamond (C900) PVC Pipe bears the mark of NSF. International (NSF). the listing of Underwriters laboratory, Inc. (Ul), and (DRI4 & DRI8) bears the listing of Factory Mutual (FM). --- Diamond (C900) PVC Pipe utilizes a gasket, per ASTM F477. to seal the ',integral bell socket to the spigot of the next joint (which conforms to 'the requirements of (ASTM D3139.) Each male end is beveled to "facilitate joint assembly. and the spigot is referenced marked to ensure :proper insertion depth. Diamond furnished lubricant is to be used in the :joining process. Diamond C900 Is supplied In 20 foot lengths. Physical Properties of PVC 12454: Property ASTM Test D792 D638 D638 D256 Minimum ,Specific Gravity ,Tensile Strength. psi Tensile Modulus, psi :IZOD Impact Strength, 1.40 7,000 400,000 65 ft.. Ib./in. SHORT FORM Specification for Diamond C900 PVC Water Pipe Diamond C900 PYC Water Pipe shall be made of compounds conforming 1.0 ASTM DI784 with a cell classification of 12454. DiamoJld C900 shaJlmeet all l]lC dimensional. chemical, aJldphysical requiremenL" HS outlined in A WW A (:900 and will be supplied in 20 foot laying Jengths. joinl~ shall meet the ,requiremcnts of ASTM 3139 llnd shall be formed using 'Rieber Technology. Gaskcts shall meet the requirements of ASTM F477. Potable water pipe Shllll be manuf:lctllrcd from National S.lniultion Foundation (NS1-") approved compounds. e w~~"~;~~:a.~~C~~-t ~lJJfO~Bnll'" .\ r \UnlYlnnlll.. ""~"'~' S:"'" ":;:;~~.--;:;;r;'"';~'..'f:'~r.' ~,' Factory Mutual Systems APPROVED Dfciil1orid'plastics Corporation \) 1212 Johnstown Road \) Grand Island, Nebraska 68803 \)308.384.4400 ~ FERGUSON~ 16 ::: PIPE ::: C900 SPF:CIFICA TJON DATA _: :- > , -', ',',,,\",:;,:: Rieber Joint illustration :A 20 Foot Laying Lengths All dimensions are given In Inches and (mm) :..... .,,,... '.. ... . .'. .... .'// .'.1 . ~~ ...- ..:. ~ ~ .. . .:. ....... .. =- . t ". . .. ~ .. ..:i .~ ~ .- ..(300)"" .......(335.3) ..... ,..... ..:..>:;-../.... ...,...,.../...:--:.....-...- - :........ .'.-.........{23.9S).........;..(18..62}...:... .....( 134])....... :.......... ,_' :.~.~.:...;: . .....~...::.,.::.......:.': .....................:.........:....:....:..:..........::.......:......:......... J . ..........::....:. ~" ::....'.:...:.. ....: ....:... "Possessron ofthls page does nol constitute on offer,to sen.;" ---- DiciiiibridPlastics Corporation () 1212 Johnstown Road () Grand Island. Nebraska 68803 () 308.384.4400 ~ FERGUSON" 17 ~ r-- S1 FERGUSON' :,'~~~~:t~~~~:.~~E " " ,,: ",~:<;,::p'IPE~~iif~6~~,dRX~'~O~P~' ..1' '.~ TI1isletter is to certify that all ca5tIron Pipe and Fittings manufactured by c1iarlotte Pipe and Foundry Company are manufactured in,thC? Uriited S~tes and conform !othe following standards: ;.. SERVICE'WEIGHTHUBAND SPIGOT PIPE AND FITI1NGS ASTMA 74 ....( . '. ... . CISPIHS 74 ANSI. A 112.5.1 IAPMO Listed ISO 9001,2000 EXTRAHEA VY HUB AND SPIGOT PIPE AND FITI1NGS ,ASTMA 74 CISPIHS 74.. ANSI AI12.5.i IAPMPO Listed ISO 9001, 2000 NO HUB PIPE AND FITI1NGS, . Cast Iron SoilPipelnstitut!?Standard No. 301 ASTM A 888 ., IAPMO Listed' . ~ ISO 9001, 2000, NO HUB'COUPLINGS . CastIron Soil Pipe Instil:1Jte Standard No. 310 NO HUB HEAVY DUTY COUPLINGS ASTMC 1540 ' CHARLOTTE SEAL GASKETS ASTM C 564 CISPI HSN W ARCO-OUIK- TITE GASKETS ASTM C 564 CISPI HSN Very truly yours, ~~1.;lf.4_,J. ~., 'Hooper Hardison, Executive Vice President '~Of.'/iJ~ Jlj'otaryPublic My commission expires July 02, 2007 PO Box 35430 Ch;uto~'NC 28235 USA 704/372-5030 800/438-6091 FAX 800/553-1605 11/1112005 18 r-- ::: FITTINGS ::: TYLER CERT DI FITTING WA CERTIFICATION DI FITTING FOR WATER STAR SPVC4008 4000 SER PVC STARGRIP REST ~ FERGUSON~ 19 ::: FITTINGS ::: Tyler/Union ------. SPEClFlCA nONS For OucOle Iron Attlngs for Water and Other Uqulds Introductlon: Union Found!)' Company manufactures a complete line o( Dudile Iron fillings for use in many water supply and service applicalions. Jhese ruUngs are manufactured under slandards promulgated by The American 'Waler Works Association (AWWA) and American National Slandards InsUlule (ANSI) where applicable. Olher Ilams nol covered by ANSlIAWWA Standards are manuf{lctured under Union Found!)' Slandards. UJ.119n.EoJ.IO!:lJY. OJ.aa.ulC\clu.ce.~_ QOly _Qllctile l~ pr9duC<t~. ~Q. ~[BY:IJ.Qo..P[Q<Jy~m...nm.<1e.. All Ductile Iron castings are Grade 70-50-05. The (ollowing fillings lines are manufactured by Union Found!)' and-are listed with the corresponding latest revision of ANSIIAWWA Standards as of December, 1994- Product Mechanical Jolnt=-..n..u__. . --- ~Compacl ~ FullBody Push-on Joint- Union-tile Compact Sizes ----. 3" -24" 3"-36" 4"-24" Standard ANSI/AWWA C-1531A21.53 ANSIIAWWA C-110/A21.10 (excludes 2" size) ANSlIAWWA C-153/A21.53 Flanged Fillings. Class 125 Faced & Drilled 2" - 24" ANSIIAWWA C-110/A21.10, ANSI/AWWA C-1151A21.15 & .(excludes 2" size) ANSI B16.1 Class 125 (NOTE: Flange ends on Compact rutings are not of the same-thickness as caned for In these standards, and are Manufacturer's Standard) Fabricated Flange Malerial- Flange Pipe ~lIer Flanges Glands- MJ Compacl. MJ Full Body MJ Retainer Compact MJ Retainer Full Body Split Glands Hydrant Gland Specially Products- . Union Flanges Tyton I Push.in Plugs 3".24" 3" -12" 3" -12" 2" - 36" 3" - 12" 3" -36" 4" -12" 6" - 8" 3" -12" 3" -12" ANSlIAWWA C-1151A21.15 & ANSIIAWWA C-110/A21.10 ANSIIAWWA C-1531A21.53 ANSIIAWWA C-1101A21.10 (excepl21 ManufacttlreF's Standard Manufacl.ure(s Standard Manufacturer's Standard Manufacturer's Standard Manufacturer's Standilrd ANSIIAWWA C-1101A21.10 ANSIIAWWA C-111/A21.11 (Rubber Gasket Joints) applies to all C-11.0 and C-153 Fillings. All UFCO fillings meet ANSUAWWA C-1041A21A which establishes Standards (or Cement lining and Asphaltic ooallng. Trier P"ope/UliIicies DMslon . Po O. b2027 . Tyler. lX 75710.'(903)882-5511 Union FouncIty Company. P.O. Boot 3<>> . Arrislon, AJobomo . (2561236-7601 ~ FERGUSON~ 20 - ::: FITTINGS ::: PVC Stargrip@series 4000 DESCRIPTION Mechanical Joint Wedge Action Restraint for PVC Pipe, Patent #5,071, I 75 The PVC Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional restraining system for mechanical joint fittings (A WW A 153 or C II 0), valves, fire hydrants and all classes ofPVC pipe. FEATURES AND ADVANTAGES . The design has been proven in the market since 1992. .. Can be used on C900 or IPS PVC Pipe. · Gland is made from high strength Ductile Iron per ASTMA536 Grade 65-45-12 and is compatible with all Mechanical Joints Conforming toANSII A WWA CIIl/ A21.11. · ~liminates tie rods and thrust blocks. . Listed with Underwriters Laboratories and approved by Factory Mutual Research for sizes 3 "-12". · The safety factor is twice (2: I) the standardized pressure rating of the pipe on which it is used. · Entire unit, including bolts, is made of ductile iron making it less susceptible to corrosion · Double headed torque off nuts are the same wrench size. · Wlll fit any Mechanical Joint configuration meaning compatibility with different types of instaIIations. . Will deflect as much as an MJ fitting and will not require special considerations when used in lieu of a standard gland. · Larger ill so it can be used on out of round pipe for fewer installation prob- lems. · Break offbolt is designed with collars so that a wrench won't slip off the bottom for easier instaIlation. . J3reak offbolt is designed so that you can't over torque and damage PVC pipe · Heavier than most other PVC Joint Restraints for better corrosion resistance. · All sizes have curved wedges that will not flatten pipe. ,,--... Tel: (800) 999-3009, (281) 558-3000, Fax: (281) 558-9000 ~ FERGUSONB 21 ::: FITTINGS ::: PVC Stargrip@series 4000 Mechanical Joint Wedge Action Restraint for PVC Pipe, Patent #5,071,175 TECHNICAL INFORMATION T-HEAD BOLT & NUT DETAILS ANSI/ASSA C9llO ClOD DR 14 200 PSI DR 18 150 PSI DR 25 100 PSI AHSUAWWA C905 ClOD DR 18 235 PSI DR 21 200 PSI DR 25 165 PSI DR 32.5 125 PSI ASTM02241 IPS 00 SDR 17 250 PSI SDR 21 200 PSI SDR 25 165 PSI c Pipe Size (In.) 3 4-24 30-36 42-48 Bolt Size (in.) 518 314 1 1 1/4 Range of Torque (ft-lbaj 45-60 75-90 llJO.120 12Q.150 These torque ranges are requirements of AWWA C600. Standanllzed pressure Ratings I:lr the ordilllllY water wOIn with Transient BUrges only. Ratings 818 fer PVC pipes with SERIES 4000 Retainer. PVC STARGRIP SPECIFICATIONS NOM. SIZE C800 Pipe 00 IPS Pipe 00 "A B C. "0 T.aoltB Approx WT Size/No. LBS. 3" 3.98 3.50 4.09 7.79 8.50 3/4 5/8 (4) 10 4" 4.80 4.50 4.93 9.16 9.64 7/8 3/4 (4) 11 6" 6.90 6.63 7.03 11.16 11.72 7/8 3/4 (6) 15 8" 9.05 8.63 9.18 13.75 13.97 7/8 3/4 (6) 23 10" 11.10 10.75 11.23 16.00 16.18 7/8 3/4 (8) 30 12" 13.20 12.75 13.33 18.25 18.23 7/8 3/4 (8) 34 14" 15.30 N/A 15.45 20.75 20.38 7/8 3/4 (10) 49 16" 17.40 N/A 17.55 23.00 22.46 7/8 3/4 (12) 59 18" 19.50 N/A 19.65 25.25 24.56 7/8 3/4 (12) 67 20' 21.60 N/A 21.75 27.50 26.66 7/8 3/4 (14) 79 24' 25.80 N/A 25.95 32.00 30.86 7/8 3/4 (16) 102 30' 32.00 N/A 32.18 39.38 36.82 1-1/8 1 (20) 150 36" 38.30 N/A 38.48 46.25 43.12 1-118 1 (24) 180 " Dimension C is after assembly on pipe. All dimensions in Inches. --- Tel: (800) 999-3009, (281) 558-3000, Fax: (281) 558-9000 ~ FERGUSON~ 22 ::: VALVES ::: AFC AFC2508FMLAOL RW OL GATE VALVE U ACCUCAST AVBX126 #107 VLV BX SWR WI LID ~ FERGUSON' 25 --- ::: VALVES ::: CONSlRucnON AMERICAN FLOW CONTROL A SERIES 2500 RESILlENTWEDGE VALVE Upper O-ring seal$ can be replaced while the valve Is fully open and under pressure DuctUelron operatIng nut provides / strenglh and durability. Thrust Washers rTlJrumlze operating torque. Lower O-rIng seal seals IubncatlOn chamber. High strength bronze s1em and nut resists corrosion and abuse. ...-.... FusIon bonded epoxy coatIng Inside and ou! ensures maximum corroSion resistance for lOng seMce life. Ducllle Iron construction - greater strength, durabilrty, and lighter welght than cost Iron COnstnJctiOCl. 250 p.s.J.g. pressure rating. Smooth, waterway construction - l000k full port diameter waferwoy. No recesses to trap dabns or obstruct flow. Reduces pl.lTlptng costs. ~- Rubber encapsulated ductile Iron wedge design ensures drop tight seal every time wrth low stem torque. ~ FERGUSON~ 26 ::: VALVES ::: -.. SECTlONALDRAWlNGS/DIMENSIONS AMERICAN FLOW CONTROL A SERIES 2500 RFSlLIENTWEDGE VALVE A VALVE SIZE QUANTIlY NRS OS&Y DIRECTION OF OPENING END CONNECTION INDICATOR POST FlANGE OTHER REQUIREMENTS 12 CCW CW YES NO W'-- . - -- -.- rn'_~- -- _. .. - I T C 1 lYTON@{TY) '=tbi - L' I D ---r-- ~- E o __ I I I _ ----I-. ~1l,.~, PVC ~ LEND TO [NO _J THREADED (SCREW) OPTIONAL END CONNECTIONS DIMENSION VAlVE SIZE 2" 2- 1/2" 3- 4" 6" 8- 10" 12" End to End - MJ x MJ 8-114 . 8-5/8 11 12 12-1/2 14-3/4 16-5/8 End to End - FL x FL 7 7-112 8 9 10-1/2 11- 112 13 14 End to End - TV x 1Y - - - 13-1/2 16-7/8 18-1/2 20- 1/2 22-3/8 End to End - FL x MJ - - - 10 11-114 12 13-7/8 15-5/16 End to End - FL x 1Y - - - 11-1/4 . 13-11/16 15 16-3/4 18-3/1 6 End to End - FL x MJ TaoDlna - - - 10-118 11-1/4 12-5/8 13-7/8 15-5/16 End to End - PVC x PVC 10-3/4 11-1/8 11-318 - - - . - End to End - Threaded 6-1/4 7-3/8 7-3/8 - r - - - - End to End - Class 250 Fiance - . 11- 1/8 12 15-7/8 16-1/2 18 19-3/4 A 9-1/4 11-1/32 11-27/32 13.3/8 16-314 20-3/16 24-118 27-1/2 B 2-112 . 2-1/2 2-1/2 2-1/2 2.1/2 2-1/2 2-1/2 C - . - 4 5-7/32 5.1/2 5-518 5-5/8 D . - 1-1/8 1-1/4 i 1-7/16 1-5/8 1-7/8 2 E 3-3/4 4 4 4 , 5.7/32 5-1/2 . - ; F 2 NPT 2-1/2 NPT 3NPT - . - - . - Handwheel Diameter 8 8 8 10 12 14 16 16 No. of Turns to Open 11 11 13 13 19 26 32 38 1. Valv.; 3".12" meet or exceed r-.qulremenls of AWWA C.515. 2. 250 p.l-l.g. rated worlclng pre..ure. 3. 4" through 12" volves may be orcS.red In configurations WhIch are UL Usted and FM Approved. 4. Fusion bonded epoxy coating meets or exceeds requirements of AWWA C550. 5. Flangec:lendl are In accordance with ANSVAWWA Cll0/A21.10 [ANSI 816.1, Class 125)- ~" 6.. Threaded ends are In accordance with ANSI 116.4, Class 125- 7. Mechanical joint ends are In accordance with ANSI/A'W'NA C111/A21.11. 8. Tyton~ end. and push-on ends are In accordance with AHSI/AWWA C111/A21.11 for cast Iron (C) size PVC or ductile Iron pipe. 9. PVC encls for steel (IPS) sizes of PVC or sfeel pipe. 10.4" through 12" valves are certified to ANSI!NSF $tandard 61. ~ FERGUSON a 27 ~ PARrS LIST ~NRS ..---. ::: VALVES ::: AMERICAN FLOW CONTROL A SERIES 2500 RFSILIENTWEDGE VALVE 2 14 R.f De$CrlDtlon Material 1 Hex Hd Bolt 618-11 Steel. SAE arode 2. ASTM 1>307, zInC Dlated 2 Opelahng I'M 0uc1I\e too. ASTM A536 2"Sa 3 OffiCI Nltl1le rubber 4 Lower lMJSt Wasl"el NVI6n 101 Federal Soec No. L-P-401A 6 Stulllna Box Gasket l'itrlle rubber o:itiO 6 Hex Hd Bolt. 518-11 S1eeL SAE arode 2. ASlM 1>307. Zinc elated 7 SIuffM Box Duc1le Iron. ASTM A536 8 Bonnet Duc1Ue ton. ASlM A536 10 1h:oat FIorQe Nilrle lUbber Gasket 11 Vctve Bodv Ductile ton. ASlM A536 12 Stem Monaanese bronze 13 Wedae Nut I.Atvv-IClnese bronze 14 Ile$UIent Wedge Duclle kon. ASTM A536 coated wflh n1tJle n.tlber 16 Hale Nut, 518-11 steel SAE OJode 2, ASTM 1>307, Zinc Plated 17 Honc:twheeI Ductile ton. ASlM A536 21 Hex Hd Bolt. 518-11 steel SAE crode 2. AS1M X307. zinc ololed 29 Flat Washer. 518 In Steel, SAE. zinc Dlated 49 OffiCI Nitrile rubt:l9I 65 Upper Ttvust 'M:lsher stolniElss SteeL TYPe 304 11 - 15 NOT AVAILABLE UL.FI.4 (NRS WITH HANOWHEEL) OS&y Note. Construcllon shown Is typical of 4"-12 " sizes hf Deser' n Mal.rlal 2 Sf Nut For I brO$$ 2 B -N ber 4 Bress. ASTM 836. UNS C26000 5 Nlldle I\ot)ber C 8 Ducffle ton. ASlM A536 9 steel rod 2 ASTM 7Z1n ated 10 Nltrle rubber 20 11 Ducl1le Iron AS1M A536 12 Free c bross 16 13 Ie Iron ASTM 6 20 _9 14 Ductile Iron. ASTM A536 coated wflh 21 16 ~Ie lUbber Hex steel SAE rade:2 ASTM 07 zinc BrO$$ AS1M F467 UNS C270Q0 Ducflle Iron. ASTM A536 Stolness steel 15 IAe n ASTM A536 S1eeL SAE rode 2 ASlM A307 zinc lotad Slntered bronze. ollmplegnated. ASTM 8438. Group 1. T n 24 Pocldng R Tallow ir'rlxegnoted fIox 25 Yoke Duclle ton. ASTM A536 Note. Construcllon shown Is typical of 4".12 " skes /'-. ~ FERGUSONe 28 ..,'. ~r :::V ~LVEsr:::. ~. gl ~. s (Y)-318V1HV^ ----- .::2 ~"~.. a:~ "~f'~ '.'1 '...... ~ ~~a:::, 1 . :.:: 'OJ" . . N ffil-. g S ~ ~ '<::t\O \0 1.1) '<::t cY'l OlD ..... N NcY'l 5 co 0 \0 \0 \0\0 ..... ..... ..... \0 co cY'l'<::t w a.. >- I- :s: w ex: u VI w U w a... N ~ (8)-318VIHV^ \0\0 NN ~~ << r ~ ~T ... j! oq ----.. ~fmGuSON' 30 ,--..... ::: FIRE::: WATEROUS WWB67LAOLS 5-1/4 VO WB67 HYD 5FT BURY OL UA AMES FIRE AND WATERWORKS A069116 FLGXCIOD SS IN-BUILD RSR NIBCO NKW900WU 6 CI UL FM WAF CHK VLV DIXON R21133LU 2-1/2X6 90 SIA CONN .---.... ------. ~ FERGUSON" 31 CONSlRUCTION TRAVEL STOP NUT-Provides a posltlve limit to main rod travel. 360. NOZZLE SECTION ROTATION- The Woterous slaInless steel retOlnlng ring system allows 3600 rotation by merely loosening !he nange bolts. and turning the nozzle section to the exact position desired. .--- TRAFFIC SECTlON-I'OIts ore designed to break at !he ground line. Slmple low cost I9polt kit available. ALL BRONZE DRAlN.No compoSition. plastic. rubber or leather face to wear. peel or crack. . ::: FIRE ::: AMERICAN FLOW CONTROL A 5-114" PACER FIRE HYDRANT FW BonOM AND STRAPPING LUGS- All ,,,,,,,,,,,, to make - "","" ~ it """"""" ,_ and eo<e<. ~ 1.1387 lWO PIECE OPERATING NUT-Ductile Iron upper section provides strength for wrenching. Lower portion Is bronze for smooth operation and corrosion reSls- . tonca. MECHANICALLY ATTACHED NOZZLES- Field replacement of damaged noz- zles In minutes by one person. CENTRIFUGALLY CAST DUCTILE IRON BARRELS-Stronger. smoother and more uniform than stot1c cost borrels. BRONZE TO BRONZE SEATING-O-ilng pratected bronze valve seat ttveods Into 0 bronze Insert In the hydrant bot- tom. INTEGRAL CAP NUT AND LOWER WASHER-Protects rod threads from cor. rOSlon Ond makes servicing 9QSo{. Valve assembly locked In place. n cannot detach accidentoJly. ~. Fully complies with AWWA C-S02 and Is available In configurations y.'hlch are UL Usted and FM Approved. ~ FERGUSON~ 1 32 ::: FIRE ::: _ SECTIONAL DRA WlNGS/DIMENSIONS AMERICAN FLOW CONTROL 5-114" PACER FIRE HYDRANT NOZZLE SECTION 8-.3/8 6-1/4 18 NOMINAL GROUND LINE B ~ 8-.3/8 DIA A 7-5/8 .3-5/8 ,---- FLANGED ~ FERGUSON~ A 2-1/2 IN. HOSE CONNECTiON (THREAD SIZE: 0.0. X _ T.P.Ll .3 IN., .3-1/2 IN., 4 IN., 4-1/2 IN. OR 5 IN PUMPER CONNECTION (THREAD SIZE: 0.0. X _ T.P.Ll OPTIONAL ROCKER LUG CAP r 6" BOTTOM .... 9-.3/4 End Connection l L M N Flanged 8-1/4 11 6 L Mechanical Joint 7-3/4 11-1/16 7 Rlngtlte 9-718 9-1/4 7 Tyton 9-3/8 9-1/8 7 7-.3/8 DIA PVC 9-3/4 8-3/4 6-3/4 a" BOTTOM LOWER STANDPIPE r 11-1/16DIA l (6) 7/8 DIA HOLES - EOUALL Y SPACED ON 9-1/2 BC =rr N ~ dl MECHANICAL JOINT RINGTITE JOINT' 4" BOTTOM End Connection L M N Flanged 8-5/8 9 4-5/8 Mechanical Joint 8-7/8 9-1/16 4-15/16 End Connection L M N Mechanical Joint 9-7/8 13-5/16 9-3/16 11 N ~ :U II N ~ dJ TYTON JOINT PVC JOINT 33 ::: FIRE ::: A PARTS LIST AMERICAN FLOW CONTROL ,r-- 5-114" PACER FIRE HYDRANT "~ REF NO. DESCRIPTION MATERIAL 89 3 O-ring Buna-N 5 Flange gosket Neoprene 16 90 6 Hex hd bolt. 5/B-l1 x 3 In. Plated steel 178 ~'7B 6A Hex hd bolt. 5/B-ll x 3-3/4 In. Plated steel 17A 6B Hex hd bon, SIB-II x 3 in. Plated steel 60 6C Hex nut. 5/B-Il Plated steel 99 116 7 Drain plunger Red brass 117 B Cotter pin. 1/4 x 1-1/2 In. Stainless steel 82 9 Naule cop chain. single or double Plated steel 85 11 10 NaWe cop. hose or pumper Cost Iron 12 11 Cop gasket Neoprene 86 12 NoWe. hose or pumper Brass 25 10 16 Flat hd screw. 1/4-2Ox 1/2 In. Stainless steel 17A Operating nut. lower Bronze 83 9 17B Operating nut. upper Cost Iron 61 84 25 Valve rod bushing Red brass 6A 29 lower standpipe CentrilugaUy cost ductile lIOn pipe 64 30 Crossarm DUClUe Iron 62 59 31 Valve seat Bronze 6C 40 34 Upper valve washer Cost Iron 35 Main valve rubber Buno-N 56 71 36 lower valve waSher Cost Iron 67 37 Hydrant bottom Cost Iron 40 Upper standpipe Centrifugally cost ductile iron pipe 92 64 54 Drain bushing Brass 68 56 Support Casl Iron 57 O-ring Buno-N 113 59 O-ring Buno-N 63 60 Nonie section Cast Iron 61 Bury depth pIote Alurrunum 6e 61 Bury depth pIote washer Platedsleel ----- 62 lock ring clamp MaUeab!e Iron 63 Standpipe flange Ductile lIon 64 64 Flange lock ring SIoinless steel 87 67 Coupling sleeve (2 halves) Cost Iron 71 Upper rod Steel 68 72 lower rod Steel 29 77 O-ring Buna-N 81 Groove pin. 3/32 x 7116 In. Beryllium copper 72 82 Upper tube seal Buno-N 8 83 lower tube seal Buna-N 84 Support gosket Buna-N 30 85 Support lube Cost Iron 31 86 Stop nut Plated steel 7 87 Coupling nut Bross 64 B8 Coupling stud Stainless steel 81 69 Bushing Brass 90 Thrust ring Teflon 6 92 Uppel standpipe gasket Neoprene 5 97 Valve seat Insert Bronze 97 99 Pipe plug Brass 62 113 Breakable flange Ductile Iron 6C 77 116 Seal. pumper nouia Buna-N 54 117 Retainer. pumper nOU!e Ductle Iron 3 34 35 36 37 SUBMITTAL DATA ,,--... Depth of trench or bury Number of hose nozzles Steamer nozzle size Inlet pipe connection size Hose nozzle size Nozzle cap chains Yes I No Type of base connection Direction to open City Specification Paint color Steamer nozzle Yes I No ~ FERGUSON~ 34 ,,--., Series IBR:.~,.. ES-A-lnBuildingRiser A AMES In-Building Riser.s> i Sizes: 4" - 1 O. (102 :"'250mm) . , . '. ". l.... FIRE&WATERWORKS ........---.. Features · Cost savings · COrTosion resistant stainless steel construction, type 304SST . Ease of Installation and light weight allows one person to position and handle the riser · Minimal site preparation; joint restraint one-piece construction reduces time and labor; no missing parts, no leaks; easily identifiable for approvals · UUFM approved . Sizes: available in 4' - 10' (100-250mm) with various lengths to meet al/ local requirements · Designed to meet NFPA 24 Section 8-3,2 . · AWWA C900 InleVDIP · AWWA C606 Outlet Series IBR In-Building Risers are used to connect the main fire supply to the building overhead fire system. The fitting passes under the foundation without Joints and extends up through the floor. Provided with instal/ation tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connec- tion to the underground supply (AWWA C900 PVC and Ductile Iron Pipe) and industry standard grooved-end connection (AWWA C606) on the building side for easy connection to the overhead fire sprinkler system. Ames In-Building Risers are precision engineered and manufactured to provide exceptional reliability and reduce installation time & labor costs associated with field assembly. In accordance with NFPA-24, the UUFM approved In-Building Risers replace numerous fittings, elbows & spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation. The use of stainless steel significantly increas- es the reliability and life of the riser. Job Name . Contractor .--------.-.. Job Location Engineer Approval Contractor's P.O. No. Representative Approval Ames product specifications In U.s. customary units and metric are approxlmate and are provided lor reference only. For precise measurements, please contact Ames Technical Service. Amos reseryes the right to Change or modify product design, construcUon, speclficaUons. or materials without prior notice and without Incurring any obligation to make suCh changes and modifications on Ames products previously or subsequenUy sold. "''''----~*".._-''j. .. l-~___.,.,..~_.,_..,...,."......,.,..."...".._........_...,.."'"'...............~......__...__...._...._,.........~..........._..._.....""_._____'..._..~___..__.___. WWW.amesflrewater.com ,-. Specifications In-Building Riser shall be installed as indicated on the plans. Riser shall be composed of a single extended 90 degree fitting of fabricated 304 stainless steel tub- ing, maximum working pressure 200psl (14 bar). The fitting shall have a grooved-end connection on the outlet (building) side and a CIPS coupler on the inlet (underground) side. The In-Building Riser shall be an Ames Rre & Waterworks Series IBR. Approvals Fittings FM UL <@>@ class 1920 (HKQA) (4"-10") Dimensions - Weights ~H~A T ~ Grooved End , . I (Flange Optional) I B ! 11 CIPS Coupling Tie-Rod Bracket ------- I.. C )01 SIZE (ON) WEIGHT In. mm A (00) In. mm It. em 1!Js. C It. em 5, 10lA 114 183 Consult factory for custom leg dimensions. A Standards NFPA - Designed to allow the contractor to conform to NFPA 24 Section 8-3.2: Where a riser is close to building foundations, under- ground fittings of proper design and type shall be used to avoid pipe joints being located under the founda- tions. NFPA - 24,7.1.1,8-3.4 End Connections: Horizontal End: Mates with Ductile Iron Pipe and AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe Equivalent OD's) Utilizes Gasket conforming to UL 157 with "Lock in" gasket configuration SIZE (ON) MATING PIPE 00 In. mm In. mm Vertical End: Meets AwwA C-606 dimensions for roll grooved pipe Meets AWWA C-207 class D for flanges Ratings Meets AWWA C-900 pressure class 200, DR 14 Pipe Testing Welds are 100% leak tested at the factory SIZE DESIGN PROOf PRESSURE In. 4 6 8 10 mm psi 1000 1000 800 800 bar 70 70 56 56 102 150 200 250 IMPORTANT: Inquire with governing authorities Jor loeallnstallation requirements. AMES I'1RE&WATERWORK'; A Division of Watts Regulator Company www.amesfirewater.com 1427 North Market Blvd. " Suite #9 · Sacramento, CA 95834. Phone: 916-928-0123. Fax: 916-928-9333 --- ES-A-lnBuildingRiser 0536 ......-..._-,._""'_..._,..."_......'"!'..w..~.,_.._. .' ---""'-~'''''--- ,IClAmes Fire & Waterworks 2005 ...,.._......_~--.,--._---..._,---.,.._.._,.._....,--~-.........,._..~"-.-._,_.~...,.-~,... POlltH-ROEMER, INC. IWe Cerritos, California Union, New Jersey ,,-.... Fire Protection Products Suboidtary of Jay R. Smith Mfg. Co. ~ Cl '" 5 > a: '" '" w Cl w V) a: ~ :::l V) .... o w V) :::l a: '" .... ~ :::; a; u; z o a.. :3 a: o z: w =: :::l ~- u.i t.) ;:: o ;z t- :::l o :I: ... ~ w to Z ~ t.) c :z 0( w t.) Z 0( a: w -' a t- V) a: w a: i= t.) ~ :::l ;z -< =: o MEM.ER 'U~.~' Ii". '. . :' . I ,~. ;.J?-:" .' \. .: .., \ ' "~.....~/ ,. EXPOSED FIRE DEP1: INLET CONNECTIONS-CLAPPER TYPE THREE-WAY WITH TRIPLE CLAPPER RECJULARL V FURNISHED: Cast brass three-way Inlet body, drop clappers and pin lug swivels. Size and outlet location as selected by Figure Number. Lettering as selected. Back Outlet Fig. Size o 5740. .. . . .. . .. . . . . .. . .... 4" x 21h" x 2Y2"x 21/2" o 5741 .. .. .. .. .. . .. . .. .. ... 6" x 2'h" x 2'h-x 2'12- OPTIONAL FINISHES: o -8 Polished Brass o -C Rough Chrome Plated o -D Polished Chrome Plated Angle Outlet Fig. Size o 5745. . . . . . . . . . . . . . . . . . . .. 4- x 2112" x 2'h"x 2'12" o 5746. . . . . . . . . . . . . . . . . . . .. 6- x 2'12- x 21h-x 2'12- LETTERING: o AUTO. SPKR. o STANDPIPE THREADS DNST o Other TWO-WAY WITH DOUBLE CLAPPERS WITH PLATE AND PLUGS RECJULARL V FURNISHED: Cast brass two-way Inlet body with drop clappers, pin lug swivels and plugs and chains. Cast brass round wall plate with lettering as selected. Outlet and inlet size as selected by Figure Number. Back Outlet ,.--- Fig. No. 5751 57si 5753 5754 Size 4x21hx21h 6 x 21/2 x 2112 4x3x3 6x3x3 OPTIONAL FINISHES: o - 8 Polished Brass o - C Rough Chrome Plated o - D Polished Chrome Plated DATE 3-1-86 E is' 1 \~ I ~01 1'h" ~,/~''''''' SUFFlX-F A 8Y2 1Q1h 1Q1h 11 B 121h 1H~ 12112 121h C 93A 12 93/4 12 D 8 9 8 9 E 14 16112 14 161fz All DIMENSIONS IN INCHES LETTERING: o AUTO. SPKR. o STANDPIPE o DRY STANDPIPE VARIATIONS: o - F Sillcock flange plate with sillcock THREADS DNST o Other FIGURE NUMBER A . --- - FactoI}' Only Fire Hose Fittings ";";;~I-'''''''''''lIIII~~~_''~"~-_~~"___________~~.___y""""_,_,,--~,,,~~_'Ill~''~,_,,,,,;o,_",:":~,,,... Round Escutcheon Plates Used to trim out and identify exposed fire department connections. . Branding: Auto-Spkr 1 . Cast finish 2 -- Pip;l--'~- Hole -1---'------ , Material Part # Size i 0.0. Size 2%'11-7-5/8" 3X" brass'.;'REP250ASk{(\i: 4" i 9-1/4" 4Yz" brass REP400AS-' ::: J ~:;~~:: :~:: ~~~:~~t~ 1;\:::~~~k1~gA~~j'::\ 6" i 11-114" 6%" I brass ['.:YREP600AS ';\';'1 I Standpipe or Auto Spkr-Standplpe branding also available 2 Polished or polished chrome finishes also available . aluminum is painted red """"Mli<~..il!~_-""'O:!~_~.:a~<llI.~_~___",<_.,.,.",~,,, Aluminum Caps and Plugs with Chain ------- Extruded hardcoated aluminum Rocker Lug --.----1-.-.--...--1----.----.--. Size I Thread Part # I ------:p.---=r NPSH !ii~,:NARC100i(:;:~A\;..;>,1 '-;j"-' r-NST (NH) "';'AFC100F,"""""< :~:: I ~~ l~~! Ij~\\I~fl~ij& 4" I NST (NH) .. AFC400F- 41/" I NST (NH) ...........'....A.FC4"OF.'.1...",.,.". /2 1::;.<:,1,:;;.:" .,.' ~ ~I .. "':~.'~"'~:/~"~\~':<l Not all sizes are stocked Extruded hardcoated aluminum Rocker Lug Size I Thread T--- Part # I '1Yz" j NST (NH) '.. ..... .... ,APP150F-.:..... ..... . 2Yz" NST (NH) lli')?','AFP250F.,'H,':<: 4" I. NST (NH) I AFP400F=--- Not all sizes ara stocked ~U;I_"~__'\$li;\"'~~""~__..,"""",,Siji,~ Brass Caps and Plugs with Chain Cast brass finish Pin lug . Rocker lug -C polished chrome plated Note: RFC100F pictured --Size~-r-'Thread--'I Part # ~ ~-..~n~',,; ____~~~.~._. 1 . NST (NH) Ic:'~Rr..C100F5;",.:; 1 W' j NST (NH) H,~;'iFC15(ii=.~l'I:;";~, ~~: i ~~ 1~~l ~r~I~~I~:,l:" 2~ j NST (NH) 1'\FC250F,~.,,>:, ~f: I ~~ 1~~1 i~;'ll~J 4Yz" NST (NH):N;;15c;. " 1" 1Yz" 2%" 3" 6" Cast brass finish Pin lug -C pOliShed chrome plated Size I Thread L .., ...... Part# . ,. ..... . i m: ! ~a (~~~))) [i!~~~~;E!:!~!j;!a~('\l':<:''!lll 3" I NST (NH) !;!"~;":;,;}:jiiiJOF;{.\'>':::' 4%" I NST (NH) h'[:iX'~X:Fe~6.oF;;':Ht;,::1 -~l:,;"">,;;"':I'FI?,150::.',<,,,,,',,.',""'."j 2~" I N~~~ 1;'~\\i;~l;%f~pi5.8":;:'::;'\';'j 5PL107...------.--~~- Dixon Valv;"&c~~pii;gcO: Can 877-963-4966 -1'II_""G~"1I.1 ~--391 .r- 250 PSI CWP Iron Body Check Valves Fire Protection Valve. UL Listed FMRC Approved. Double-Door · Wafer Style · Rubber Seat · Spring Actuated PART 1. Body UL/ULC LISTED · FMRC APPROVED MATERIAL LIST SPECIFICATION Ductile Iron ASTM A 536, Grade 65-45-12with Buna-N Resilient Seat Molded to Body Bronze ASTM B 584 Alloy C83600 Stainless Steel Stainless Steel Stainless Steel Stainless Steel Steel Steel Buna-N Nylon 6 2. Disc 3. Torsion Spring 4. Hinge Pin 5. Stop Pin 6. Thrust Bearing 7. Hinge Pin Retainer 8. Stop Pin Retainer 9. Stabilization Sphere 10. Spacer KW-900-W Wafer Style ~ DIMENSIONS-WEIGHTS-QUANTITIES Dimensions Size ABC ""in.Iiiiii:'" In. mm. In. mm. In. mm. In. mm. 2'12 65 2.38 60 6.00 152 .125 3 3.50 3 80 2.63 67 5.63 143 .188 5 3.875 4 100 2.63 67 7.75 197 .625 16 4.75 5 125 325 83 7.56 192 .813 21 5.5 6 150 375 95 8.63 219 .813 21 6.25 8 200 5.00 127 12.25 311 1.000 25 8.00 10 250 5.50 140 14.75 375 2.125 54 10.12 12 300 7.13 181 17.38 441 1.938 49 12.00 14 350 7.25 184 17.75 451 3.25 83 16 400 7.50 191 20.25 514 4.50 114 NOTE: 14" and 16" sizes, 150 PSI WWP, FM approved only _ P.O.A. D E In. 1.313 1.688 3.063 3.625 4.25 5.50 8.50 9.25 13.00 15.00 89 98 121 140 159 203 257 305 mm. 33 43 78 92 108 140 216 235 330 381 NOTE: ...~~~) CN 108 178 440 560 840 1600 2700 4700 5200 7200 Weight Lbs. Kg. 4.3 1.95 6.1 2.77 8.8 399 13.0 5.90 18.0 8.16 37.0 16.78 65.0 29.48 94.0 42.64 200.0 90.7 5 2850 129.28 FEATURES . Spring loaded for fast closure, eliminating reverse flow slam and waler hammer. . Easily installed, with gaske~ between standard class 125 flanges. . Only one sel of flange studs is needed. . May be installed in both horizontal and vertical lines with upward flow. Twin Disc Check Valves can be installed horizontally or in the vertical position with flow up. CAUTION: For horizontal flow applications. the valve must be installed willi diSC hinge pin in the vertical position to insure proper operation. WARNING: c@ <8> APPROVED @ NOTE: 1. These are not to be used as steam valves 2. Valves are not to be used near a reciprocating air compressor 3. Install 5 pipe diameters minimum downstream from pump discharge or elbows to avoid flow turbulence. Flow straigllteners may be required in extreme cases. On pump discharge. the preferred check valves are in-line spring loaded. swing design with lever and weight or lever and spring. NIBCO INC. WORLD HEADQUARTERS' 1516 MIDDLEBURY 51. . ElKHART. IN 46516-4740 . USA. PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 . FAX: 1.800.234.0557 . INTERNATIONAL OFFICE PH: + 1.574.295.3221 . FAX: +1.574.295.3455 www.nibco.com r---- A ~o~ MOONAmerican,lnc. INDUSTRIAL. MUNICIPAL. & INTERIOR FIRE CONTROL 1678 Southwest Cutoff, Worcester, MA 01604 2112 Ball Drips r---.. Ball drips should be located in the horizontal position in the lowest possible location in the system. They are nonnally installed in the piping between the fire department connection and the system check valve. The ball seats at approximately 10 P.S.I. Available in W' and W' straight style, NPT threads. ------ .~ ::: SERVICE MATERIAL ::: MUELLER CERT COPPER TUBE CERTIFICATION FOR COPPER TUBE MUELLER MBR2B1314CCK 12X2 CC BRZ DBL STRAP SADDLE MUELLER MH15000K 2 CC X FLR CORP ST MUELLER MB25166K 2 FLR X MTR ANG BV WI LW MUELLER MB2423K12 2X12 COP MTR SETTER BASS&HAYS FOUNDRY BH55A1S 28X18 GALV MTR BX ..--- ,~. ~ FERGUSON~ 39 ,~,',:.:t~:>::;" - ~ C(--':"",:;e. >~,-~I< :., ,: ::SERYJ,SE'. MA T~RIAL::: ',> . MUELL::ER- INDlETRI,ES, I~JC. Customer Street No. City, State Order No. Attn. Date Contractor Address Contract No. r obDcscription Location . Product Certification MuellFCo~.~l'~1s ~.llll JDanufac~ in the ~....:AU tubing produced in Fulton, MS, and Wynne.AR,'j& ~css'llnd ofUNSCI2200gradcofcoppcr'and is manufactured to meet the chemical and mechanical PIopemes of the tpPlk:llblc.ASTM' spccificatiol1ll set forth below. When specified at oId" placCD1Cnt, Mueller Copper TullO .,can SUPPlY' Certifi~.TubC to meet zill requirements of the current applicable ASTM specification, at an additional cost ~ D.. Streamlin~,CopperWater Tub~.(Types K,L,M) ~ . ASTMB88 andANSIINSF 61 ..-. D.' Streamline Copper Refrigeration Service Coils ASTMB280 o StrUmline Nitrogenized ACRHard Drawn Copper Tube - ASTM'B280 DStreamlin!, ~opp~Drainage Tube (DWV) ASTM B306 o ~ygen& MedicalService Tube. To ASTM B819 (Types K & L) Hard DrawnStraigbt Lengths Only in Accordance To CGA Cleanness Specification; CGA G4.1 (Compressed Gas Association); & NFP A 99 (Health Care Facilities). NSF 61 ReStrlcti()Jl StaU:mcnt:~Copper Tube (AlloyCI2200) is certified by NSF to ANSlINSF Standard 61 forp1JblicwalQrsuppJies ni~g or Ui ,tho processofmoeting the U.S. EPA Lead and Copper Rule (S6FR 26460,1uno 7, 1991).Watcr supplies with pH less than 6.S may require corrosion control to limit copper Solubility in driilkiDg water." . , . , " . ~ P. O. BOX 849+.FUJ;.TON.MS 38843 . (662) 862-1700 . FAX (662) 862-3002 P. O. BOX 309 . WYNNE,AR 72396 . (870) 238-3201 . FAX (870) 238-8724 r-- ~FERGUSON' 40 ~ ::: SERVICEfylATERIAL ::: IVI O~~1:.~8~;BJl.iB~;~BR{~fsi~~SJBRnNZ~;,i' ' [Mueller to.) 4 5 'S~R'VIC'~;SiD'd~ES~I)~~if~EtS~RJIJ)r~"'if4,'s,/",,' "~___ ,:_ 'MUEUiE~eSelVig~,~i1,d~leSfor_us~,:o6',A~C;:'qasnr9n;'quctil~Hron,and AWWA C900 PVC plastic pipe o Outlet tap~,witheitper AW)V~t<lper:(C.~.)()rAWW8;!'P')B~ead(F.I:p,1") .: . O,For use onA;~C pi~, cast iron or ducti\ll iron pipe and Cast 'lroI{9:n,pVC pipe o 200 psig(1379 kPa)ml.Ufim,JlIP.~orking;pressUre ' . o '. ' o Brass body , o Flattened silicon bronze straps (standard), o Optional304L stainless steel slI"11Ps, o Rol1edstrap threads o O-ring sealed outlet o 3/4" thru 2" tap sizes (5/8" some styles) o Meets all applicable parts of ANSIIAWWA C800 o NSF 61 certified BR 2 B SerIes BR 2 S Series MUELLERtl Service Saddles with AWWAtaperthread .; ..: : ,! rt~;rf'ji!.r"", ., ~1\j ~t:! ...r.,~ ~.,~>' "......... Pipe 0.0, range Kind and I!.lze of pipe '. "Bronze double str~ Opllonal stainless steel double strap ,with AWWAtaper threa (C.C.) with AWWA taper thread (C.C.) Base Calalo Base Catalog Caator Number: Size of tapping Number Size of tapping Inch mm . A-C ducllle Iron, (add to "Base" to (add to "Base" to CQIlO PVC . complete catalog number compklte catalog number) I plastJo pipe 5ISl314' '1 " 1-1/4' -112' 2' 5/S" 3/4" 1" 1-1/4" r-m 2" .i/ , '. c" > 4.74--532" 121.0-135.0 4" BR 2 B 0474CC 062: 075 100 123 :1 150 200 BR 25 0474CC 062 075 100 125 1:50 200 6.84"-7,45" 174.0-189.0 6"' BR 2B 0684 CC 062 075 100 m 150 200 BR 2 5 0684CC 062 075 100 125 1:50 200 8.99--9.67" 229.O-W.o 8" BR 2 B 0899 CC 062 075 100 I2h 150 200 SR 25 0899CC 062 on 100 125 1:50 200 11.04"-12.12" 281.0-301.0 ,10" BR 2 BI104 CC 062 075' 100 125 150 200 BR251104CC 062 075 100 125 1:50 200 13.14"-14-58" 334.0-370.0 12" BR 2 B 1J14CC 062 075 100 m 150 200 BR251314CC 062 075 100 125 150 200 15.22"-16.88" 386.6428.7 14" BR2B 1522CC . 075 100 . 1:50 200 !!.R2 S 1522CC - 07~_ 100 - 1:50 200 17.32"-19.19" 439.9-487.4 16" BR2D 1732CC - 075 100 - 1:50 ,200 ..BR2S 1732CC,. 075 1100,. 150 200 , MUELLERe Service Saddles with AWWA Iron pipe thread Pipe 0.0. range Kind and lllze of Plpel Bronze doubkl Blraf. Optional Btalnlesll Bl8el double lltrap with AWWA I.P. thread ( .1; P.T.) with AWWA I.P. thread (F.I; P,T.) BaBe' Catalog Base Catalog Ceat or Number Size of tapping., Number Size of tapping Inch mm A-C ductile (add to "Baae" to (edd to "Ilue" to Iron, CQO() comp'-Ie cal8log number) comple'e celalog number) ,PVC pipe 314' l' 1-1/4" 1-112' 2" , 314'11" 1-1/4" 1-112" 2' .' 4.14'-'.32" 121.tHUO 4' DR 2 B 0414 IP 01' 100 125 1:50 200 BR250474IP 01' 100 125 150 200 6.84'-7.""" . 174.0-189.0 6' BR2B0684IP' 015 100 125 150 200 BR 2 5 0684 IP 015 100 12.5 1.50 200 8.99'-9.67" 229.0-24'.0 8' DR 2 B 0899 IP 015 \00 12.5, 1.50 200 BR 2 5 0899 IP 015 100 12.5 1.50 200 11.04'.12.12" 281.0-307.0 - 10" BR 2 B 1104 IP 01' lOll 125 1:50 200 BR2511041P 01' 100 12.5 1:50 200 111 '.".1. .." 12" BR 2B 1314 IP 01' lOll 12.5 150 :zoo BR2 S 1314IP 01, 100 12.5 150 :zoo 15.22'-16.88" 386.6-428.1 14- . BR2B 15221P 075 lOll - 1.50. :zoo BR 25 1'22 IP 01' 100 150 200 11.32".19.19" 439.1>-481 '" 16' "0 BR2B 11321P' 01' lOll ..-: 1.50 200 BR 251732 IP 0" lOll 150 200 .A-Cpipe, c:w...ISO-200pe:r ASTM~ IIIdAWWAC400_KluaJOD. 01 pip. baia. wadQJUd fa.U wilbia.thIi pipe OD.rUJI Wted.mtt. ~B cbart.. CenuifllpUy QII pipe, cl_. .5O-2S0pu ANSJI AWWA ClO2lA2I.2;ANSUAWWA CI06IA21.6;ANS1JAWWA CIO&'A21.8, oadFedo..t .cJlicolioa WW-l'-421.0..uJ0... pipo,....... ~6per ANSVAWWA CI51JA21-'1, Cut;rno OD. PVC plutic pil" per AWWA C9OO. , ..'Jbe oubide dil.lDllta' 01 A..c pipe.-its &om lIWJU~r to ~I to m&b Cftt.....ytMl 21ect the popa'. clamp: I) Determhlil! the OD. 01 the pipe . the poiat ol.addJe inlaaUllioo; 2) Prom d. pipe 0.0..... COhtlDlll oftbe."Ilbowot..~ cOOose ......,_ bu. ~_~. nal' t.t iK1lIdn the ddcrmiuct~pe d.i....r. . These machines may beus~d VlIith the ser:v.ice sa~dleslllustratedon tills page ,-..... Machine " Service saddle tac size 5/8" I" . 3/4~ 1" , 1&5TW X c;- -,- ^ , x' o:sn. IX x ',- TIiU:<:;OTni,; , ,,X- x" MEGA-:CiJTn< x xCi X PJ-.2n< ,:.,,- X X TO ORDER SPECIFY QUANTITY, OUTLET TAPPING SIZE AND CATALOG NUMBER ~ FERGUSON' 41 ----- ,,-,-." i'i', -. ::;"SERVICEMATERIAL ::: -,,\<;."" ,.'\ ,-,.'," 1/211.211 ,.GROUNIl:'KEy;'D,ESIGN CORPORAtION~,\iAtVES~(. ^" ..... (Mueller to.1 5.9 ,- ""'- -'-/:"'.;,,-:<'::'''.'''' ",'~">'~-"'::\' ,- "'''-'':-' ,,'q.iouQ<!'.I(ey;gorpOra~QP Yalve<".. '.' '. '. Ground Key Corporation Valve :~.i.~~f~~~~~~~' . ;~~.~~~~t=t'ER~ad ~i()litl~J:%UEbijE~~;'~ "';:;'. '; :,~"'INSTA-TITE Cll)Connection for 'H-15006 INSTA:~11TE~Co~~ectionJor, 'H""15024 CTS PEtubing* CTS~II~bJng~ . , 13/4" !3I4"xl"* II" II" -t- Ground Key Corporation Valve Inlet: AWWAtaper (MUELLER "CC") thread Outlet: MUELLER INSTA-TITE ConnectionJor IPSPE pipe* H-15005 [3/4" 1314" xl" * II" ,.-.. 'Ground Key Corporation Valve Inlet: AWWAtaper " (MUELLER "CC') thread Outlet: Copper flare straight connection H..15000 1112"~ 1112" x 3/4"~ 15I8~. x 314" 13/4" 1314" x ]" II" b" x ].II4"~ 1].114" 1].112"' 12" ~.. ::~~~,3;::t:atiOO Volvo -........ (MuELI~ER "CC'ythread H-15010 Outlet: COPJX::r flare eighth bend connection 1314" II" 11.1/2" 12" Ground Key Corporation Valve Inl.et:AWWA taper '., (MUELLER "CC") thread Outlet: Copper flare ,quarter bend connection ' jSI8" x 3/4" 13/4" II" '11.1/2" . 12" Rev. 4-01 ..... ~ Ground Key Corporation Valve Inlet: AWWA I.P. thread Outlet: MUELLER INSTA- TlTE Connection for IPS PE pipe* H-15Q26 13/4" II" . Ground Key Corporation Valve Inlet: AWWA I.P. thread Outlet: Copper flare straight connection H-15025 L"11I2~"'; 13/4" " II" f 11-114" 11-]/2" 12" ... Ground Key Corporation Valve . Inlet: AWWA I.P. thread . . · OuO,t: COPl"'f dare eightll , bend connection H-15035 13/4"~ liT 11.1/2" 12" Ground Key Corporation Valve Inlet: AWWA I.P. thread Outlet: Copper flare quarter bend connection .1314"* , "II' , 12" 11.1/2" 'See'chart. on pagesS.IO-S.13 for tubing and pipe thai may be used on these connection.. ~ RequIres mlnlmum ordering quantlly., Contact MUElLER Customer Service Center for minimum order requirements and availability. Nom: Sizes shown above represeni nominal size, of Inlet a1ld outlel coDlledi~ns. ~ two sizes are given, the first Is .ize of lnIel and the second Is size of outlet. . .. .. '" '. ,'.. .,.. ' ,.-.. ~ FERGUSON" 43 8D.6 (Mueller Ca.) BALL STRAIGHT SERVICE VALVES 3/411-211 SIZES ..--... Rev. 4.99 MUELLER@ 300'" Ball Straight Service Valve - MUELLER 11O@ Conductive Compression Connection for CTS a.D.* tubing - both ends Quarter turn check - lock wing. 8-25146 3600 turn option available by adding-3 suffix to catalog number (B-25146-3) 3/4R 3/4 JRt \ 1-\/2 2 5/8 3/4 3/4 \ \-\/2 2 3/4 3/4 I l \-1/2 2 MUELLER 300 Ball Straight Service Valve - MUELLER 110 Conductive Compression Connection for CTS a.D. * tubing x ELP. Quarter turn check - lock wing. 8 25170 3600 turn option available by adding -3 - suffix to catalog number (B-25170-3) ~... MUELLER 300 Ball Straight Service Valve - MUELLER 110 Compression Connection for IPS * PE pipe x ELP. Quarter turn check - lock wing. 3600 turn option available by adding -3 suffix to catalog number (B-25196-3) 8-25196 I CataJOI!size 3/4 II I Valve size 3/4 1\ II Pipe size 3/4 1\ ~" . . "".a ~~~::t3~~rvice Valve _ Copper flare nut x EI.P. Quarter turn check - lock wing. 8-25166 3600 turn option available by adding -3 suffix to catalog number (B-25166-3) Calalo size 3/4Rt 3/4 IRt I \-1/2 2 Valve size 5/8 3/4 3/4 I 1-1/2 2 Pi size 3/4 3/4 l 1 1-1/2 2 MUELLER 300 Ball Straight Service Valve - ELP. x ELP. Quarter turn check - lock wing. 3600 turn option available by adding -3 8-20200 suffix to catalog number (B-20200-3) !Catalog size ~Rl' 13/4 . .1\X3/4 IIRt ~atalog size ~ J \-1/2 12 ~.' - ----- .... P-25146 MUELLER 300 Ball Straight Service Valve - MUELLER@ Pack Joint Connection for CTS a.D. * tubing - both ends Quarter turn check - lock wing. 3600 turn option available by adding -3 suffix to catalog number (P-25146-3) 3/4 \ 1-1/2 2 3/4 \ 1-1/2 2 3/4 I 1-1/2 2 P-25170 MUELLER 300 Ball Straight Service Valve - MUELLER Pack Joint Connection for CTS O.D.* tubing x ELP. Quarter turn check - lock wing. 3600 turn option available by adding -3 suffix to catalog number (P-25170-3) 3/4 3/4x I 3/4 3/4 3/4 I 2 2 2 MUELLER 300 Ball Straight Service Valve Copper flare nut - both ends Quarter turn check - lock wing. 3600 turn option available by adding -3 suffix to catalog number (B-25143-3) "'_",d." .. 8-25143 3/4 3/4 3/4 . MUELLER 300 Ball Straight .' , . .h' " Service Valve - EI.P. x Copper flare nut . " ,. '. . Quarter turn check - lock wing. 3600 turn option available by adding -3 8 . 8 suffix to catalog number--4-3/8" -2516 laying length for retrofit applications CataloR size 3/4Rt Valve size 5/8 Pipe size 3/4 -,..".,..-",C ... MUELLER 300 Ball Straight .0 Service Valve F.I.P. x EI.P. Quarter turn check - lock wing. 3600 turn option available by adding -3 8-20245 s~ffix t~ catalog number--~-I/~" end-to-end dimensiOn for retrofit applications I Catalog size : 13/4Rt J .,..........-.. - ""'-' · See charts on pages 8D.15 and 8D.16 for lubing and pipe that can be used with this connection. tThe "R" indicates this valve has a reduced port. The pOlt size is one nominal size smaller than the valve inlet/outlet. MUELLER Valves and Couplings are manufactured and tested in accordance with ANSIIAWWA CaDD. 8A.28 I REV. 4-99 ,. I (Mueller Ca.) COPPER METER YOKES WITH HORIZONTAL INLET & OUTLET (FOR 1-1/211 & 211 FLANGED METERS) AND BYPASS 8-2423 With Mueller~ 3oo™ Ball Angle Meter Valve with meter flange x angle dual check valve with me- ter flange. Check valve in front of bypass valve. FIP end inlets and outlets FIP end inlets and outlets 8-2423-2 With Mu.:ller 300™ Ball Angle Meter Valve with meter flange x Mueller 300™ Ball Angle Meter Valve with meter flange. With Mueller~ 300TM Ball Angle Meter Valve with meter flange x Muelle~ 300™ Ball Angle Me- ler Valve with meter flange. FlP end inlets and outlets 8-2423-2-99000 Catalog number 8-2423 8-2423-2/ 8-2423-2-01 8-2423-99000 / 8-2423-2-99000 Description With Muelle~ 3oo™ Ball Angle ~elCr With Mueller 300n.! Ball Angle Meter With Mueller 300™ Ball Angle ~ter Valve with meter flange x Muelle Valve with meter flange x angle dual Valve with meter flange x Muelle 3oo™ Ball An~le Meter Valve with check valve with mete~aflr By-rass 300lM Ball Valve with meter ~Rfe. meter fl1l>n~e. y-pass with lock wing with lock wing Muelle 3 TM Bal Elevated by-q,nss with Mueller ARK Mueller OOTM Ball Valve. Valve and check valve (without chcck II ORISEAr..; Valve with IOCkin/i,8cvicc valve: B-2423-2-0~) (with check valve: B-2423-2-990 ) with by-pass) A -I I" A - (B-2423-99000 shown) T- (B-2423-2 shown) --T B 1 E J c 0 c 0 Dimensions Meter size 1-112" 8-2423, 8-2423-2 & 2" 8-242308-2423-2 & 1-112.8-2423-99000 & 2" 8-2423-99000 & 8-2423-2-01 8-2423-2- 1 ~.2423-2-99000 8-2423-2-99000 Dimension A * 13.25" 17.25" 13.25" 17.25" Dimension B - riser height 12-, IS". IS". 21", 24". 27" 12", IS". IS", 21". 24", 27" IS". 21". 24", 27" IS",21", 24", 27" Dimension C - nominal pipe 1-112" 2" 2" 2" size of inlet and outlet I. Dimension D* 21.50" 26.63" 22.63" 26.63" Dimension E - - 7.25" 7.25" ....,-,." r-- * Adjustable dimension. Copper tubing in the tie bar can be cut to accomodate shorter meters. Adjustment affects both A and D dimensions. r lee section 6 for end connections that can be used with these yokes. SPECIFY METER SIZE, RISER HEIGHT AND CATALOG NUMBER. ""'~""-~~_~""""_"'iO" -"-""'~~~'-" . ..,....---_._---~._._...._-------~_._-- ,- Part no. Height Weight # 55 A 18" 125 1 bs # 55 A1S 18" 125 lbs # 55 A2S 18" 125 1 bs # 55 B 24" 130 1 bs # 55 C 30" 135 1 bs # 55 0 36" 140 lbs # 55 E 42" 145 1 bs # 55 F 48" 150 lbs .--.. .--. # 55 Series Galvanized Meter Boxes with 28" di a. corrugated cans 45 # 548 Series Galvanized ~ieter Boxes with 24" dia. corrugated cans Part no. Height Weight # 548 A 18" 80 1 bs # 548 B 24" 85 1 bs # 548 C 30" 90 1 bs #548 0 36" 95 1 bs # 548 E 42" 100 1 bs # 548 F 48" 105 los #548 G 54" 110 1 bs #548 H 60" 115 1 bs ~ FERGUSON@ II AS IS" Disclaimers ./"--... The information contained in this submittal is a compilation of product information made available by manufactures or other suppliers about their products, and while Ferguson Enterprises, INC. ("Ferguson") makes reasonable efforts to present current information in the form in which it is received by Ferguson, the information is provided to you" AS IS," for your internal informational purposes only, without any representation or warranty of accuracy or completeness of information or other warranty of any kind, including any implied warranty of quality, merchantability, fitness for a particular purpose, or non- infringement. In no event will Ferguson be liable to any party. for any direct, indirect, incidental, special or consequential damages for use of or reliance upon any information or material presented including, but not limited to, damages arising from loss of profits, business interruption or any other damages, even if Ferguson is expressly advised about the possibility of such damages, to the fullest extent allowable by law. The material in this submittal could contain technical inaccuracies or typographical errors, and information will be changed, updated and deleted without notice. Manufacturers or other suppliers may make improvements and/or changes in the products described in this material at any time. Customer Service Policy Ferguson enterprises, Inc. is unconditionally committed to customer service satisfaction. Ferguson's commitment to assisting our customers obtain redress under the terms of manufacturers' warranties is a fundamental principle of our customer service philosophy. Ferguson does not manufacture any of the products we sell. Consequently, like our customers, Ferguson must look to manufacturers to provide warranty protection. Our customers' sole and exclusive warranty, therefor, is that provided by manufacturers. Warranty Disclaimer. Ferguson Enterprises, Inc. and its subsidiaries ("Ferguson") make no express. or implied warranties. Ferguson hereby disclaims all warranties, whether express or implied by operation of law or otherwise, including, without limitation, all implied warranties of merchantability or fitness for a particular purpose. Ferguson shall not be liable, directly or indirectly, for any loss, cost, damage or expense, including, without limitation, labor charges or consequential or incidental damages, arising directly or indirectly from the operation, condition or use of products sold by Ferguson. Ferguson's sole liability, if any, shall be limited to the product's sale price in all cases. ,--- r--- RECOMMENDED PRODUCT SPECI FICATI 0 N CHARL.TTE PIPE AND FOUNDRY COMPANY' .. '" "'1:Im~,,'i""" i~ =>"'--. .. "...... IllIIU UIIlIlD. 1iII'lUIlIIlIW Suggested Specification System: PVC Schedule 40 Pressure Pipe and Fitting System Scope: This specification covers PVC Schedule 40 pipe and fittings for pressure applications. This system is intended for pressure applications where the operating temperatul'e will not exceed 140oF. Specification: Pipe and fittings shall be manufactured from virgin rigid PVC (polyvinyl chloride) vinyl compounds with a Cell Class of 12454 as identified in ASTM D 1784. PVC Schedule 40 pipe shall be Iron Pipe Size (l PS) conforming to ASTM D 1785. PVC Schedule 40 fittings shall conform to ASTM D 2466. Pipe and fittings shall be manufactured as a system and be the product of one manufacturer. All pipe and fittings shall be manufactured in the United States. Pipe and fittings shall conform to National Sanitation Foundation (N S F) Standard 61 or the health effects portion of N S F Standard 14. -------- Installation shall comply with the latest installation instructions published by Charlotte Pipe and Foundry and shall conform to all local plumbing, building, and fire code requirements. Solvent cement joints shall be made in a two step process with primer manufactured for thermoplastic piping systems and solvent cement conforming to ASTM D 2564. The system shall be protected from chemical agents, fire stopping materials, thread sealant, plasticized vinyl products, or other aggressive chemical agents not compatible with PVC compounds. Systems shall be hydrostatically tested after installation. Testing with compressed air or gas is not recommended. Referenced Standards: ASTM D 1784 Rigid Vinyl Compounds ASTM D 1785 PVC Plastic Pipe, Schedule 40 ASTM D 2466 PVC Plastic Fittings, Schedule 40 ASTM D 2564 Solvent Cements for PVC Pipe and Fittings N S F Standard 14 Plastic Piping Components and Related Materials NSF Standard 61 Drinking Water System Components - Health Effects Note: Latest revision of all standards apply. ............ You can't beat the system.@ 7 CHARLeTTE PIPE AND FOUNDRY COMPANY r-- This is to certity that all Plastic Pipe and Fittings manufactured by Charlotte Pipe and Foundry Company are manufactured in the United States and conform to the following standards: SCD. 40 PVC PIPE ASlM D ] 784, ASlM D ] 785, ASlM D 2665 FHA UM 79a FEDERAL SPECIFICATION L-P-320a IAPMO IS 9-92, IAPMO 8-92 FTGS. IAPMO UPC ON SPECIFIED ITEMS NSF STANDARD]4 AND 6] SCD. 40 PVC DWV PIPE CELLULAR CORE ASlM D 4396, ASlM F 89] NSF STANDARD NO. ]4 IAPMO UPC SCD. 40 PVC DWV FITTINGS ASlM D 1784, ASlM D 2665, ASlM D 33] 1 FHA UM 79a FEDERAL SPECIFICATION L-P-320a NSF STANDARD NO. 14 IAPMO IS 9-92 IAPMO UPC ON SPECIFIED ITEMS PVC PRESSURE PIPE SDR-21 AND SDR-26 ASlM D ] 784, ASlM D 224] NSF STANDARD NO. 14 AND 6] PVC SCD. 40 PRESSURE FITTINGS ASlM D ] 784, ASlM D 2466 NSF STANDARD ]4 AND 61 PVC WELL CASING PIPE ASlM D ] 784, ASlM F 480 NSF STANDARD NO. ]4 AND 6] PVC SCD. 80 PIPE ASlM D ] 784, ASlM D ] 785, PVC ] ] 20 NSF STANDARD NO. ]4 AND 6] PVC SCD. 80 FITTINGS ASlM D 1784, ASlM D 2467, ASlM D 2464, ASlMF 1970 NSF STANDARD NO. 14 AND 6] PVC SEWER MAIN PIPE ASlM D ] 784, ASlM D 3034 SDR 35 ASlM D 32]2, ASlM F 477 PVC SEWER MAIN PIPE CELLULAR CORE ASlM D 4396, ASlM F 891 PS 50 ~ PO Box 35430 Charlotte, NC 28235 USA PVC TDIN WALL PIPE AND FITTING ASlM D ] 784, ASlM D 2949 NSF STANDARD NO. ]4 CPVC CTS FLOW-GUARD GOLD PIPE & ASlM D 2846 FHA UM-6] a NSF STANDARD NO. ]4. AND 6] CPVC SCD. 40 AND SCD. 80 PIPE ASlM D ] 784, ASlM F 44] NSF STANDARD NO. ]4 AND 61 CPVC SCD. 80 FITTINGS ASlM D ] 784, ASlM F 439, ASlM F 437, ASlM F 1970 NSF STANDARD NO. ] 4 AND 61 SCD. 40 ABS DWV PIPE CELLULAR CORE ASlM D 3965, ASlM F 628 NSF STANDARD NO. ]4 SCD. 40 ABS DWV FITTINGS ASlM D 3965, ASlM D 2661, ASlM D 33]] FHA UM 79a FEDERAL SPECIFICATION L-P-322b NSF STANDARD NO. 14 IAPMO IS 5-92 IAPMO UPC ON SPECIFIED ITEMS Very truly yours, IJV. <<1 A4c- 4.. ~A Hooper Hardison, Executive Vice President ~ Jf LU.L.t-anJ . Notary Public My commission expires July 02, 2007 704/372-5030 800/438-6091 FAX 800/553-1605 01/06/05 Precast Vaults ,. L -, w ,.---... Plan View Doors per City Specs. ,.----... OS&Y Gate Valve (Typ.) U.L. Backflow Preventer H Ductile Iron or C-900 Stub-out Adjustable Valve Supports Section View Materials & Features CONCRETE: 5,000 PSI REINFORCING: per ASTM A-615 or A-185. METAL DOORS AND LADDER AS SPECIFIED BY CUSTOMER. 3" 5' - 0" 9' - 0" 5' - 6" 17,800 Lbs. 4" 5' - 0" 9' - 0" 5' - 6" 18,000 Lbs. 6" 5' - 0" 9' - 0" 5' - 6" 18,000 Lbs. , 8" 1(, - 0" 9' - 0" 6' - 6" 21,000 Lbs. 10" 5' - 0" 9' - 0" 7' - 0" 22,000 Lbs. JOINTS SEALED WITH RAM-NEK. ,..-...... -No Scale- All dimensions subject to allowable specification tolerances. nTLE PLANT STATE SECTION.PAGE DATE .0. ... 12.a.4 08-15-06 .0.Hanson 3" thru 10"Double Detector Check Backflow Preventer Grand Prairie TX In Precast Concrete Vault (wI Slab Top) G Reinforced Concrete Pipe r---. ~ . 4'~ 1 T ~ . ~ <l ~ '" 4 Q5 " A ~ 4 . ~ A <l ~ '" CD 4 <J A = '" <l ctl <<1 .(\ ~ Q .. .. <l " <I <> 0 4 J () A 4 <l ~ '" '" ~ <l CI. '" . , '" ." I. Laying Length )1 ~ 1.0. I Laying I Wall I Bell , Aprox. Pipe Lenght Thickness Diameter Wt I Ft (Inches) (Feet) (Inches) (Inches) (Pounds) 12 4-6 2 16 92 15 4-6 2 19 111 18 4-6-8 2 1/2 23 168 21 4-6-8 23/4 26 1/2 214 24 4-6-8 3 30 265 27 4-6-8 31/4 33 1/2 322 30 4-6-8 31/2 37 384 33 4-6-8 33/4 401/2 451 36 4-6-8 4 44 524 39 * 4 1/4 471/2 614 42 4-6-8 4 1/2 51 685 45 * 43/4 54 1/2 789 48 4-6-8 5 58 885 51 * 51/4 61 1/2 986 54** 4-6-8 51/2 65 1,092 60** 4-6-8 6 72 1,322 66** 4-6-8 6 1/2 79 1,573 72 4-6-8 7 86 1,846 78 * * * * 84 * * * * 90 * * * * 96 * * * * 108 * * * * 120 * * * * ~ · Conforms to current ASTM C-76 or C-655 specifications for reinforced concrete pipe. * - Dimensions vary; contact manufacturer. ** - Wall C available in some market areas. -No Scale- All dimensions subject to allowable specification tolerances. ,..........., TITLE PLANT STATE SECTlON.PAGE Tongue and Groove Pipe Grand Prairie Houston TX 2.1 DATE .0. ... .0.Hanson 08-15-06 '1 'I r 1[oooo I : 18" l--oo~ Precast Drainage Structures I' 60" ~ ~ ~.. -r..... - - ~ - ~ -.. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ..:. Top View I' 60" ~ " ~:]H/2" LS6" 47" Front View Item I Height I Approx. in Isometric (Inches) Weight View (Lbs.) 'I -I _ ~ ~ - 60" Extension 6" Grate Wye Inlet Top 18 3,430 Extension 12 1,350 15 1,688 18 2,025 21 2,363 24 2,700 Slab Top 6 1,340 Grate 31/4 433 Box Varies r---., Note: 1.) Customer to specify opening size or cast iron ring and cover. TITLE Top Options for 4' x 4' Precast Box Isometric View -No Scale- All dimensions subject to allowable specification tolerances. PLANT STATE SECTION.PAGE DATE .0. ... 08-15-06 .0.Hanson Grand Prairie Houston TX 9.2 Precast Drainage Structures 6" Frame and Cover as Required by City .------ r' 17" L ~ 6" I or i-- 8" Section View Materials & Features CONCRETE: 5,000 PSI REINFORCING: per ASTM A-615 or A-185 3' - 10 1/2" ) MAXIMUM PIPE SIZE: 24" 1.0. #3 Rebar Left Exposed for Gutter Tie-In WEIGHT: BASE EXTENSION TOP 10,300 Lbs. 2,100 Lbs. 5.000 Lbs. 17,400 Lbs. Total 32" X 32" Thinwall K.O.'s Typ. 8 Places ,-..., Note: 1.) *10' Curb Inlet Top not available from Houston Plant. -No Scale- All dimensions subject to allowable specification tolerances. TITLE PLANT STATE SECTION.PAGE DATE .0. ... Grand Prairie TX 10.a.5 08-15-06 .0.Hanson Houston' 10' Curb Inlet - Dallas I Fort Worth Precast Drainage Structures ~ r--... Materials & Features MAXIMUM PIPE SIZE: 18" 1.0. R.C.P. CONCRETE: 5,000 PSI REINFORCING: per ASTM A-615 or A-185 CAST IRON FRAME & GRATE per ASTM A 48; Class 30/35 GRATE WEIGHT: 100 Lbs. CATCH BASIN WEIGHT: 2.5' ........... 1,580 Lbs. 3' ...........2,500 Lbs. 4' ........... 3,420 Lbs. 5' ........... 4,350 Lbs. EXTENSION WEIGHT: 12" ........... 500 Lbs. 18" ...........750 Lbs. r-- TITLE #24 Catch Basin 31 1/2" ~ 31 1/2" r( 2.5', 3',4' & 5' Depth Available 4"~ <- 31 1/2" ~ Thin Wall K.O.'s . -No Scale- All dimensions subject to allowable specification tolerances. PLANT STATE SECTION.PAGE DATE .0. ... .0.Hanson 08-15-06 Grand Prairie TX 8.5 Houston