ST9905DR-LR080805
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94081124.0076
Service Date: July 25, 2008
lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Batch Time: 8:25am Plant: 125
Supplier: Southern Star
Truck No: 7039 Ticket No: 01322933
Mix I.D. No.: 9363
Water Added Onsite Before Test: 10Gallons
Water Added Onsite After Test: 0 Gallons
Report Date: August 05, 2008
Project: Bethel Road I - #ST 99-05
Roadway & Drainage Improvements
City Limit Line to Freeport Parkway
Coppell, TX
Project No.: 94081124
Sample Information
Date Cast: July 25, 2008 Time: 9:15am
Sampled by: Johnny L. Clinton
Weather Conditions: Clear
Accumulative Yards: 9 Batch Size (cy): 9.00
Placement Method: Direct Discharge
Sample Locations: NE corner at back driveway
Placement Location: W side of crosswalk at USPS driveway &
driveway at back of USPS driveway
Client:
City of Coppell TX
AUn: Rick O'Dell
Engineering Dept
PO Box 9478
Coppell TX 75019
Material Information
Specified Strength: 3600 psi @ 28 Days
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, of:
Ambient Temperature, of:
Plastic Unit Weight, pcf:
Result
5.00
3.1
92
94
148.0
Specification
Test Method
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Laboratory Test Data
Age at
Set Specimen Diameter Area Date Test
No. 10 (Inches) (sq. inches) Tested (days)
1 1 6.00 28.27 08/01/2008 7
1 2 08/22/2008 28
1 3 08/22/2008 28
Services. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Maximum Compressive
Load Strength
(Ibs) (psi)
99,710 3.530
Terracon Rep: Johnny L. Clinton
Report Distribution:
(1) City of Coppel! TX
(1) Tiseo Paving Company
Reviewed by:
Eric J. C veland, P.E.
Senior Pro ct Engineer
The tests were performed in general accordance with applicable ASTM. AASHTO, or DOT test methods. This report Is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily Indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1
Dt-MWBfROI.FutureKoy