Loading...
ST9905DR-LR080730 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0063 Service Date: July 17, 2008 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Batch Time: 9:20am Plant: 111 Supplier: Southern Star Truck No: 1029 Ticket No: Mix I.D. No.: 9363 Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Report Date: July 30, 2008 Project: Bethel. Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 17, 2008 Time: 10:20am Sampled by: Johnny L. Clinton Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: SW corner Placement Location: Crosswalk on E side of Royal Lane at Bethel Road Sta. 31 +08 Client: City of Coppell TX AUn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 6.00 3.2 90 94 148.4 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 07/24/2008 7 1 2 08/14/2008 28 1 3 08/14/2008 28 Services. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 91,330 3,230 Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company Reviewed by: Terracon Rep: Johnny L. Clinton ric J. CI ve and, P.E. Senior Project Engineer The tests were performed In general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client indicated above and shall not be reproduced except In full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the locatlon(s) referenced and are not necessarily indicative of the properties of other apparently similar or Identical materials. Page 1 of 1 01.oaRJROt.f'ukJi'ii Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0065 Service Date: July 18, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Batch Time: 12:55pm Plant: 111 Supplier: Southern Star Truck No: 7039 Ticket No: 1317118 Mix I.D. No.: 9363 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Report Date: July 30, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 18, 2008 Time: 1 :20pm Sampled by: Jon M. Lindley Weather Conditions: Clear Accumulative Yards: 8 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: SE corner of Bethel Rd. & Royal Ln. Placement Location: Paving Bethel Road & Royal Lane intersection Client: City of Coppell TX AUn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 5.00 2.7 94 97 148.0 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 07/25/2008 7 1 2 08/15/2008 28 1 3 08/15/2008 28 Services. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 113,400 4,010 Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company Reviewed by: Terracon Rep: Jon M. Lindley Eric J. C veland, P.E. Senior P ct Engineer The tests were performed In general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client indicated above and shall not be reproduced except In full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or Identical materials. Page 1 of 1 QI-MWBtROt.fub.nK.,- CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0069 Service Date: July 21, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 o Gallons o Gallons Report Date: July 30, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 21, 2008 Time: 7:40am Sampled by: Johnny L. Clinton Weather Conditions: Clear Accumulative Yards: 20 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: See Placement Location Placement Location: Paving Eastbound turn lane at Creekview Client: City of Coppell TX AUn: Rick O'Dell ' Engineering.Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days. Batch Time: 7:15am Supplier: Tiseo Paving Truck No: Mix 1.0. No.: 2478M Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: Batch #2 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 1.00 3.8 92 93 149.2 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 07/28/2008 7 1 2 08/18/2008 28 1 3 08/18/2008 28 Services.. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 124,480 4,400 The tests were performed In general accordance with applicable ASTM, AASHTO, or DQT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the locatlon(s) referenced and are not necessarily indicative of the properties of other apparently similar or Identical materials. Page 1 of 3 O1""El/RIlI./'."."'" CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0070 Service Date: July 21, 2008 lrerracon 8901 Carpenter Frwy. Ste #100 Dallas, Texas 75247 (214) 630-1010 Batch Time: 8:39am Plant: 105 Supplier: Southern Star Truck No: 9023 Ticket No: 01318241 Mix 1.0. No.: 9363 Water Added Onsite Before Test: 12Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Report Date: July 30, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 21, 2008 Time: 10:00am Sampled by: Johnny L. Clinton Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): 10.00 Placement Method: Sample Locations: See Placement Location Placement Location: Crosswalk at Creekview & Bethel Client: City of Coppell TX Attn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Result 5.00 3.2 91 94 146.8 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratorv Test Data Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested (days) 1 ' 1 '6.00 28.27 07/28/2008 7 1 2 08/18/2008 28 1 3 08/18/2008 28 Services. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load ' Strength (Ibs) (psi) 111,060 3,930 Report Distribution: (1) City 01 Coppell TX (1) Tiseo Paving Company Reviewed by: Terracon Rep: Johnny L. Clinton rlc J. leveland, P.E. Senio Project Engineer The tests were performed In general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusiv y for the use of the client Indicated above and shall not be reproduced except In full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 OI-MNBJROt.fllli.Ir. K.y CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0069 Service Date: July 21,2008 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 o Gallons o Gallons Report Date: July 30, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 21, 2008 Time: 10:30am Sampled by: Johnny L. Clinton . Weather Conditions: Clear Accumulative Yards: 140 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: See Placement Location Placement Location: Paving Eastbound turn lane at CiCi's Client: City of Coppell TX AUn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 10:06am Supplier: Tiseo Paving Truck No: Mix 1.0. No.: 2478M Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: Batch #14 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 1.00 4.0 93 94 148.4 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C 1064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested (days) 2 1 6.00 28.27 07/28/2008 7 2 2 08/18/2008 28 2 3 08/18/2008 . 28 Services. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 128,090 4,530 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the locatlon(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 at-MWBIROt"fulur.Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0069 Service Date: July 21,2008 lrerracon 6901 Carpenter Frwy, Ste #100 Dallas, Texas 75247. (214) 630-1010 o Gallons o Gallons Report Date: July 30, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 21, 2008 Time: 12:50pm Sampled by: Johnny L. Clinton Weather Conditions: Clear Accumulative Yards: 240 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: See Placement Location Placement Location: Paving Eastbound turn lane at Royal Lane Client: City of Coppell TX AUn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 12:19pm Supplier: Tiseo Paving Truck No: Mix I.D. No.: 2478M Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: Batch #24 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 1.00 3.2 99 100 152 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested ~ 3 1 6.00 28.27 07/28/2008 7 . 3 2 08/18/2008 28 3 3 08/18/2008 28 Services. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast c<;lmpressive strength samples. Maximum Compressive Load StrenWh (Ibs) (psi 116,030 4,100 Terracon Rep: Johnny L. Clinton Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company Reviewed by: . . En ~C veland, P.E. Senior roject Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is excluslvel for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted h rein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily Indicative of the properties of other apparently Sl liar or identical mateiiais: Page 3 of 3 Q1-M'NSlRDI.fut&n K.y CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0071 Service Date: July 22, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 o Gallons o Gallons Report Date: July 30, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 22, 2008 Time: 8:00am Sampled by: Johnny L. Clinton Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: W bound turn lane at Royal Lane Placement Location: W bound turn lane at Royal Ln.; E bound turn lane into Trade Point; W bound into USPS; W bound into rear of USPS Client: City of Coppell TX Attn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 7:51 am Supplier: Tiseo Paving Truck No: Mix 1.0. No.: 2478M Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, OF: Plastic Unit Weight, pcf: Result 1.00 1.0 93 94 154.8 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. 10 (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 07/29/2008 7 1 2 08/19/2008 28 1 3 08/19/2008 28 Services. Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strength (Ibs) (psi) 158,430 5,600 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily Indicative of the properties of other apparently similar or Identical materials. Page 1 of2 Dt-MWBIR01.futUlel<ey CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0071 Service Date: July 22, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 o Gallons o Gallons Report Date: July 30, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Cappell, TX Project No.: 94081124 Sample Information Date Cast: July 22, 2008 , Time: 10:30am Sampled by: Johnny L. Clinton Weather Conditions: Clear Accumulative Yards: 120 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: W bound turn lane into USPS Placement Location: W bound turn lane at Royal Ln.; E bound turn lane into Trade Point; W bound into USPS; W bound into rear of USPS Client: City of Coppell TX Attn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 10:18am Supplier: Tiseo Paving Truck No: Mix I.D. No.: 2478M Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 1.50 3.6 97 98 148.5 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1 064 ASTM C138 Laboratorv Test Data Age at Set Specimen Diameter Area Date Test No. JD (inches) (sq. inches) Tested (days) 2 1 6.00 28.27 07/29/2008 7 2 2 08/19/2008 28 2 3 08/19/2008 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Maximum Compressive Load Strenijth (Ibs) (psi 122,680 4,340 Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company Reviewed by: Terracon Rep: Johnny L. Clinton Eric J. eveland, P.E. Senior roject Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusive I for the use .of the client Indicated above and shall not be reproduced except In full without the written consent of our company. Test results transmitted he eln are only applicable to the actual samples tested a\ the location(s) referenced and are not necessarily indicaUve of the properties of other apparently similar or Identical materials. Page 2 of 2 OtoMWBlROt-FuknK.,.