Loading...
Chateaus-LR081008 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214)630-9745 Client: CTM-Coppel!, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report of In-Place Density Testing Report No.: 332484 Project No.: 0814523 Date of Service: 09/08/2008 Report Date: 10/08/2008 Project: Chateaus of Cappel! Services: Perform In-Place Density Testing PROJECT DATA Contractor: Test Method: ASTM 0-6938 Gauge: Troxler 3440 Gauge Serial No: 26991 Test Mode: DT Standard Counts Moisture Density Current: 676 Current: 2381 Previous: 674 Previous: 2372 MOISTURE DENSITY RELATIONS MID No. 325190 325191 Description Dark Brown I Sandy Silty Clay wI Trace LSF Brown I Clayey Silty Sand Moisture % Maximum Density (pet) 109.5 116.7 Project Requirements Moisture Density -2/+2 95 min -2/+2 95 min 16.4 13.0 FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Utility backfill Storm sewer, Line A-1, Station 2+00, l' below 6" 325190 17.6 123.2 104.8 96 grade Utility backfill 2 Storm sewer, Line A-1, Station 5+00, l' below 6" 325190 17.8 122.6 104.1 95 grade Utility backfill 3 Storm sewer, Line A-1, Station 8+00, 3' below 6" 325190 17.2 124.0 105.8 97 grade Utility backfill 4 Storm sewer, Line A-1, Station 8+00, l' below 6" 325190 17.2 123.1 105.0 96 grade Utility backfill 5 Storm sewer, Line A-1, Station 11 +00, 2' below 6" 325190 18.1 123.3 104.4 95 grade Utility backfill 6 Storm sewer, Line A-1, Station 11 +00, l' below 6" 325190 18.2 122.5 103.6 95 grade Utility backfill 7 Storm sewer, Line A-1, Station 14+00,2' below 6" 325190 17.3 122.8 104.7 96 grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 1 of 5 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 2 of 5 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freldrlch, Ste 195, Austin, TX 78744 .. Corporate Phone: (214) 630-9745 Report of In-Place Density Testing Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC Report No.: 332484 520 Central Parkway E Project No.: 0814523 Piano, TX 75074 Date of Service: 09/08/2008 Report Date: 10/08/2008 Project: Chateaus of Coppell Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Utility backfill 20 Block C, lot 10, lateral line, Station 0+20, 3' 6" 325191 12.3 130.3 116.0 99 below grade Utility backfill 21 Block C, lot 10, lateral line, Station 0+20, l' 6" 325191 13.4 129.9 114.5 98 below grade Utility backfill 22 Block C, lot 14, lateral line, Station 0+25, 3' 6" 325191 12.5 129.6 115.2 99 below grade Utility backfill 23 Block C,lot 14, lateral line, Station 0+25, l' 6" 325191 12.4 129.4 115.1 99 below grade Utility backfill 24 Block C, lot 50, lateral line, Station 0+25, l' 6" 325191 12.6 131.0 116.3 100 below grade Utility backfill 25 Block C, lot 18, lateral line, Station 0+15, 3' 6" 325191 13.0 128.9 114.1 98 below grade Utility backfill 26 Block C, lot 18, lateral line, Station 0+15, l' 6" 325191 13.0 129.8 114.9 99 below grade Utility backfill 27 Block C, lot 56, lateral line, Station 0+25, 3' 6" 325191 12.6 129.4 114.9 99 below grade Utility backfill 28 Block C, lot 56, lateral line, Station 0+25, l' 6" 325191 12.9 130.6 115.7 99 below grade Utility backfill 29 Block C, lot 42, lateral line, Station 0+20, 3' 6" 325191 12.9 130.5 115.6 99 below grade Utility backfill 30 Block C, lot 42, lateral line, Station 0+20, l' 6" 325191 12.0 131.1 117.1 100 below grade Utility backfill 31 Block C, lot 38, lateral line, Station 0+20, l' 6" 325191 11.2 128.8 115.8 99 below grade LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 3 of 5 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freldrlch, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report of In-Place Density Testing Report No.: 332484 Project No.: 0814523 Date of Service: 09/08/2008 Report Date: 10/08/2008 Project: Chateaus of Coppell Services: Perform In-Place Density Testing FIELD DENSITY TESTS Test Probe MID Moisture Wet Density Dry Density Density No Test Location Depth No. % (pet) (pet) (%max) Utility backfill 32 Block C, lot 27, lateral line, Station 0+20, l' 6" 325191 12.7 128.4 113.9 98 below grade Utility backfill 33 Block C, lot 31, lateral line, Station 0+20, l' 6" 325191 11.4 128.4 115.3 99 below grade LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KW) Page 4 of 5