Loading...
Chateaus-LR081006 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC Report No.: 330029 520 Central Parkway E Project No.: 0814523 Piano, TX 75074 Date of Service: 08/08/2008 Report Date: 10/06/2008 project:; hateaus of Coppell Service : Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring ~mp~' b'7,my to, ",,'"' ,"d ,..Ii", :~:::: :~::~'''b~ ,~"dmd, , Contractor: Concrete Supplier: LMC Plant: NA Specification Requirements Strength: 4,200 psi @ 28 days Slump (in.): 2" - 4" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (In) (in') (Ibs) (psi) 1 1 08/15/2008 7 5.99 28.18 105,520 3,740 2 09/05/2008 28 5.99 28.18 127,820 4,540 3 09/05/2008 28 5.99 28.18 119,490 4,240 Average 4,390 4 10/03/2008 56 5.99 28.18 154,060 5,470 Rone Engineering . ~E3 ~~ [Q] ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Mix Design I.D.: 1851 Placement Date: 08/08/2008 Weather Conditions: Cloudy Time Sampled: 01 :OOpm Temperature - Air: 890F Truck No: 959 Air Content: 4.6% Overall Placement Location: Manholes, Station 4+37 line D, Station 3+86.62 and Station 4+51.54 line B Batch time: 11: 12pm Concrete: 970F Ticket No: 7196571 Unit Weight (pet): NA Measured Slump (inches) 2.75 Sample Location: Station 3+86.62 Fracture Type Type2 Type3 Type2 Type2 Type 6 It? /7 / c cJ e CI live LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Lid. (ADW/CL) Page 1 of 2 Rone Engineeri.ng " 8908 Ambassador Row,Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freldrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: CTM-Coppel!, LLC C/o Lenart Develop 520 Central Parkway E Plana, TX 75074 Report of In-Place Density Testing 334286 Project: Chateaus of Cappel! Services: Perform In-Place Density Testing Contractor: Test Method: ASTM D-6938 Gauge: Troxler 3430 Gauge Serial No: 24675 Test Mode: DT Standard Counts oistur.e Density Current: 533 Current: 2474 Previous: 535 Previous: 2471 MOISTURE DENSITY RELATIONS MID No. 325190 Description Dark Brown I Sandy Silty Clay wI Trace LSF Moisture % Maximum Density (pet) 109.5 Project Requirements Moisture Density Optimum +4 95 min 16.4 Test Location FIELD DENSITY TESTS Probe MID Depth No. Test No Moisture Wet Density Dry Density Density % (pet) (pet) (% maxI Utilities Franchise utilities at Montebello, lot 17, l' below 8" 325190 18.4 123.6 104.4 95 grade Utilities ~ 2 Franchise utilities at Montebello, lot 17, 2' below 8" 325190 17.8 12 104.0 95 .. grade ~'" /' Utilities .~ 3 Franchise utilities at Montebello, lot 14, l' below 8" 325190 ...,..16:7 '122.7 105.1 96 grade / Utilities /' 4 Franchise utilities at Montebello, lot 14, 2' below 8" 325190,,""'- 18.6 124.3 ~ 1'04.8 96 grade ./ / '" Utilities i' 5 Franchise utilities at Montebello, lot 11, l' below 8" /325190 18.6 123.5 104.1 95 grade ./ "' ..~ Utilities J- 6 Franchise utilities at Montebello, lot 11, 2' below 325190 18.2'/' 123.0 104.1 95 grade I .' Utilities 7 Franchise utilities at "'Y' "below 325190 17.2 123.6 105.5 96 grade LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/CL) Page 1 of 4 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/CL) Page 2 of 4 Rone Engineering . 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report of In-Place Density Testing Report No.: 334286 Project No.: 0814523 Date of Service: 09/26/2008 Report Date: 10/06/2008 Project: Chateaus of Coppell Services: Perform In-Place Density Testing Test Location FIELD DENSITY TESTS Probe MID Depth No. Test No 20 Utilities Franchise utilities al Corsea, 101 52, 2' below grade Moisture Wet Density Dry Density Density % (pet) (pet) (% max) 8" 325190 17.6 123.6 105.1 96 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/CL) Page 3 of 4