Loading...
Chateaus-LR081014 Rone Engineering " 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freldrlch, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC Report No.: 332920 520 Central Parkway E Project No.: 0814523 Piano, TX 75074 Date of Service: 09/12/2008 Report Date: 10/14/2008 Client: Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Concrete Supplier: Lattimore Plant: 14 Specification Requirements Strength: 4,200 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C.., 143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 1701 Placement Date: 09/12/2008 Weather Conditions: Cloudy Time Sampled: 03:15pm Temperature - Air: 920F Truck No: 3033 Air Content: 4.1 % Overall Placement Location: Storm sewer and manhole walls, Montebello Drive, Station 10+09 Measured Slump (inches) 4.5 Batch time: 02:17pm Concrete: 900F Ticket No: 14329964 Unit Weight (pct): NA Sample Location: Manhole, same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (In) (In2) (Ibs) (psi) Type 1 1 09/19/2008 7 5.99 28.18 101,470 3,600 Type2 1 2 10/10/2008 28 5.99 28.18 124,300 ~ Type2 1 3 10/10/2008 28 5.99 28.18 129,580 Type2 Average 4,500 4 11/07/2008 56 ~E:J ~[g ~ lS] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Remarks: Water added at site: 10 gallons (llj ~ Id {u zoo LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KW/CL) Page 1 of 2