ST9905DR-LR080822
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94081124.0094
Service Date: August 14, 2008
lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
o Gallons
o Gallons
Report Date: August 22, 2008
Project: Bethel Road I - #ST 99-05
Roadway & Drainage Improvements
City Limit Line to Freeport Parkway
Coppell, TX
Project No.: 94081124
Sample Information
Date Cast: August 14, 2008 Time: 11 :OOam
Sampled by: Koda W. Shadix
Weather Conditions: Sunny
Accumulative Yards: 10 Batch Size (cy): 10.00
Placement Method: Direct Discharge
Sample Locations: Sta. 29+96
Placement Location: Royal Lane, Center Lanes
Sta. 29+00 - Sta. 30+00
Client:
City of Coppell TX
Attn: Rick O'Dell
Engineering Dept
PO Box 9478
Coppell TX 75019
Materia/Information
Specified Strength: 3600 psi @ 28 Days
Batch Time: 10:04am Plant: 14
Supplier: TISEO Paving Co.
Truck No: 161
Mix I.D. No.: 2478H
Water Added Onsite Before Test:
Water Added Onsite After Test:
Ticket No:
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, of:
Ambient Temperature, of:
Plastic Unit Weight, pcf:
Result
4.00
3.75
95
90
151.2
Specification
Test Method
ASTM C143
ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Laboratorv Test Data
Age at
Set Specimen Diameter Area Date Test
No. ID (inches) (sq. inches) Tested (days)
1 1 6.00 28.27 08/21/2008 7
1 2 09/11/2008 28
1 3 09/11/2008 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Maximum Compressive
Load Strenp.th
(Ibs) (pSI)
136,980 4,840
Report Distribution:
(1) City of Coppell TX
(1) Tiseo Paving Company
Reviewed by:
Terracon Rep: Koda W. Shadix
Eric J. eveland, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except In full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced 'and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1
OMXiR/ROHw.. K.y