Loading...
ST9905DR-LR080820 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94081124.0071 Service Date: July 22, 2008 lrerracon 8901 Carpenter Frwy, Ste#100 Dallas, Texas 75247 (214) 630-1 01 0 o Gallons o Gallons Report Date: August 20, 2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 22, 2008 Time: 8:00am Sampled by: Johnny L. Clinton Weather Conditions: Clear Accumulative Yards: 10 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: W bound turn lane at Royal Lane Placement.Location: W bound turn lane at Royal Ln.; E bound turn lane into Trade Point; W bound into USPS; W bound into rear of USPS Client: City of Coppell TX AUn: Rick O'Dell . Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days ,J Batch Time: 7:51 am Supplier: Tiseo Paving Truck No: Mix I.D. No.: 2478M Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 1.00 1.0 93 94 154.8 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratorv Test Data Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 07/29/2008 7 158,430 5,600 08/19/2008 28 192,680 6,810 08/19/2008 28 183,990 6,510 Average (28 Days) 6,660 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 1 1 1 Specimen ID 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 The tests were performed in general accordance wllh applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client indicated above and shall not be reproduced except In full wllhout the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily Indicative of the properties of other apparently similar or identical materials. Page 1 of2 O\.MWBIROW'I.CIIO Koy CONC~ETE COMPRESSIVE STRENGTH TEST ~eport Number: 94081124.0071 Service Date: July 22, 2008 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 OGallons o Gallons Report Date:August 20,2008 Project: Bethel Road I - #ST 99-05 Roadway & Drainage Improvements City Limit Line to Freeport Parkway Coppell, TX Project No.: 94081124 Sample Information Date Cast: July 22, 2008 Time: 10:30am Sampled by: Johnny L. Clinton Weather Conditions: Clear Accumulative Yards: 120 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: W bound turn lane into USPS Placement Location: W bound turn lane at Royal Ln.; E bound turn lane into Trade Point; W bound into USPS; W bound into rear 'of USPS Client: City of Coppell TX AUn: Rick O'Dell Engineering Dept PO Box 9478 Coppell TX 75019 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 10:18am Supplier: Tiseo Paving Truck No: Mix 1.0. No.: 2478M Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 1.50 3.6 97 98 148.5 Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Laboratorv Test Data Age at Maximum Compressive Date Test Load . Strength Tested (days) (Ibs) (psi) 07/29/2008 7 122,680 4,340 08/19/2008 28 157,560 5,570 08/19/2008 28 144,390 5,110 Average (28 Days) 5,340 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 2 2 2 Specimen 10 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Report Distribution: (1) City of Coppell TX (1) Tiseo Paving Company Reviewed by: Terracon Rep: Johnny L. Clinton Erl J. Cleveland, P.E. Se lor Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report Is exclusively for the use of the client Indicated above and shall not be reproduced except In full without the written consent of our company. Test results transmitted herein are only applicable 10 lhe actual samples tesled at the locatlon(s) referenced and are nol necessarily Indicative of the properties of other apparently similar or Identical malerlals. Page 2 of 2 01-MWB1R01.f~. K....