Loading...
Chicken Express-LR080912 (3) l ""~ ;fnJormation I:!!.~. .To Build On Engineering · Consulting. Testing REPORT OF CONCRETE COMPRESSION rEST TESTED FOR: Y HYNES Y HYNES GENERAL CONTRACTOR TRINITY VIEW RD ERFORD, TX 76087 DATE: September 12, 2008 REVISION #1 PSI REPORT NO.: 341-80040-40 FIELD DATA: LOCATION OF PLACEMENT PROJECT: , Entrance Off of Denton Tap Road Entrance Ramp DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY September 12, 2008 02:00 pm 3 3/4 5.1 93 OF 90 September 13, 2008 PSI\Gabriel Ortiz Gateway Concrete SUPPLIER DELIVERY TICKET NO.fTRUCK NO, MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Gateway Concrete 51267 605 Sand Sand Color (Red) NOTE' APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED' SLUMP' C143' AIR CONTENT- C2311EXCLUDING SEC, 61" TEMPERATURE: C1064' CYLINDERS- C31 (I=XCLUDING SEe 101 2l- SAMPLING: C172 COMPRESSION TEST RESULTS ASTM C39; C1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK. LABORATORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) (PSI) ASTM C39 2114 A 7 09/19/08 93470 6.00 28.27 3310 Type 2 2114 B 28 10/10/08 129320 6.00 28.27 4570 Type 2 2114 C 28 10/10/08 131200 6.00 28.27 4640 Type 2 2114 D H HOLD oW?i' 'Zf SPECIFICATIONS 28 REMARKS: X 'nders picked up by PSI sentative. Cylinders made by Architect's or Contracto(s representative. TECHNICIAN: W cc: Hynes; Davis; Stone Test res co 7 XII::: '00' t/ -V applicab a Iy with applicable Respectfu~~~mW:el prOfess;'\. \'fJ'" Industries, Inc. THESE TEST RESULTS APPL Y ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT. REPORTS MAY NOT BE REPRODUCED, EXCEPT IN FULL, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC. PSI A-200-4N F Professional Service Industries, Inc.' 4087 Shilling Way' Dallas, TX 75237' Phone 214/330-9211 . Fax 214/467-0031 l-lIo S -, lriformation ~~. .To Build On Engineering. Consulting. Testing REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: RANDY HYNES RANDY HYNES GENERAL CONTRACTOR 101 TRINITY VIEW RD WEATHERFORD, TX 76087 DATE: September 12, 2008 REVISION #1 PSI REPORT NO.: 341-80040-42 PROJECT: CHICKEN EXPRESS RESTAURANT COPPELL, TX FIELD DATA: LOCATION OF PLACEMENT Sidewalk Off of Beltline Road Sidewalk Off of Beltline Road DATE PLACED TIME SLUMP, IN. AIR CONTENT, % AIR TEMPERATURE, of CONCRETE TEMPERATURE DATE RECEIVED IN LAB FIELD DATA SUBMITTED BY MIX DATA SUBMITTED BY September 12, 2008 03:30 pm 4 1/2 5.3 90 OF 91 September 13, 2008 PSI\Gabriel Ortiz Gateway Concrete SUPPLIER DELIVERY TICKET NO.rrRUCK NO. MIX NUMBER AND PROPORTIONS CEMENT WATER FINE AGGREGATE COARSE AGGREGATE ADMIXTURE Gateway Concrete 51270 605 Sand Rock None NOTE- APPLICABLE ASTM STANDARDS UNLESS OTHERWISE INDICATED: SLUMP- C143' AIR CONTENT- C231 (EXCLUDING SEe 6\" TEMPERATURE- Cl064' CYLINDERS' C31'~XCLUD!NG SEe 1012\' SAMPLING' Cl72 COMPRESSION TEST RESULTS ASTM C39: C1231 SPECIMEN TEST TOTAL CYLINDER CYLINDER COMPRESSIVE TYPE OF BREAK. LAB ORA TORY IDENTIFICATION AGE DATE OF LOAD DIAMETER AREA STRENGTH AS SHOWN IN NUMBER OR SET NO. (DAYS) TEST (LBS.) (IN.) (sa. IN.) (PSI) ASTM C39 2115 A 7 09/19/08 92870 6.00 28.27 3290 Type 2 2115 B 28 10/10/08 149870 6.00 28.27 5300 Type 2 2115 C 28 10/10/08 142300 6.00 28.27 5030 Type 3 SPECIFICATIONS 28 4500 REMARKS: ~ Cylinders made by PSI representative. Cylinders picked up by PSI ~ representative. Cylinders made by Architect's or Contraclo~s representative. X Test resulls comply with applicable specifications. Cylinders delivered to PSI laboratory. Test results do not comply with applicable specifications. TECHNICIAN: William Miller cc: Hynes; Davis; Stone Respectfully submitted, Professional Service Industries, Inc. THESE TEST RESULTS APPLY ONLY TO THE SPECIFIC SAMPLES TESTED AND MAY NOT BE INDICATIVE OF THE ENTIRE CONCRETE PLACEMENT. REPORTS MA Y NOT BE REPRODUCED. EXCEPT IN FUll, WITHOUT WRITTEN PERMISSION BY PROFESSIONAL SERVICE INDUSTRIES, INC. PSI A.200.4N F Professional Service Industries, Inc.. 4087 Shilling Way. Dallas, TX 75237. Phone 214/330-9211. Fax 214/467-0031