Loading...
Rolling Oaks MC-LR081106 l I THOMPSO CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELl TX 75019 Date: 11/06/2008 Report 10: K60533 - DA08152.000 Report of Concrete Compressive Strenath Tests Project: ROLLING OAKS MEMORIAL CENTER PHASE I Supplier: TXIINDUSTRIES FREEPORT PARKWA Y Location: PA VING, 70' EAST OF FREEPORT PARKWA Y ENTRANCE Cast Date: 10/30/2008 Ticket: 778896 In-Lab Date: 10/31/2008 Truck Number: 1005 Batch Time: Concrete Mix: 8274 Test Time: 14:30 Specimens Made By: CT ..... .._--..~....... - ~- ~. A.A. _.._ Initial Curing Final Curing Curing Method: Min. Temp: Max Temp: Curing Method: Other of of Fog Room Physical Properties of Concrete (ASTM C143, C231 , C138, C1064) Specified Strength (fc) Slump Air Content Density Temperature 4000 psi @ 28 days 5.00 In. 3.5% 82 deg. F Compressive Strengths (ASTM C39) Specimen Number 1 Age in Days 7 Diameter (inches) 4.00 Area (sq. inches) 12.57 Max. load (Ibs.) 28,850 Average: Compressive Strength (psi) 2300 2300 Percent offc Type of Fracture Wedge ....,,"'''''''',.''\\\\1 ~~"\~.9.f...rc-t: tll, -cp' .., *"""1. II on T exa 7Ik~~ '..f * ~ *: \.~ ~ ....................... ............ ~ .J. HAMMERBERG ~ ... .. ............. ... ........I.....i'!. ~~E 80610 l~ H . ~ ~tI ,.o~::.~.~cIlNsE.9.... ~f(;.:;- (I. ".Is ..?...... uC!>'" - III 'ONAL f.\'~-tP- \\\'\\.'\"t\.,,,,,~ 58 CC: TXIINDUSTRIES J. STUART TODD ARCHITECTS THE FAIN COMPANY Comments: ONE CYLINDER HELD FOR 28-DA Y TESTING 10575 Newkirk Street. Suite 780 I Dallas, TX 75220 I Phone: 972-831-1111 This test report relates only to the items tested and shall not be reproduced, except in full, without the written approval of CTLIThompson Texas, LLC