Rolling Oaks MC-LR080929 Compaction Test Report T CTL I THOMPSON T E X A S. l l C CUENT: CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 DATE: OQ/2QInR PROJECT NUMBER: DAOA15? 000 Phase: 345 REPORT NUMBER: ~ SHEET:....2... OF -L SUBJECT: ROLLING OAKS MEMORIAL CENTER PHASE I FREEPORT PARKWAY COPPELL, TX 1 LABORATORY FIELD TEST NO. lOCATION DEPTH TEST MAX OMC% DRY MC% COM- SOil TYPE TYPE DENSITY DENSITY PACTION FEET PCF PCF % WEST DR. FROM INTERSECTION CURVE NO 5 70 OF MIDDLE DR. N. 450' 0.0 NUC 96.0 24.0 91.0 24.6 95 JOB NO DAOB152.000 LIME STABILIZED SUBGRADE PREPARATION 1 BELOW SUBGRADE TO +4 % OF OPTIMUM THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF OUR OBSERVATION OF Fill PLACEMENT, AS WEll AS THE TESTS SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR OBSERVER IS NOT PRESENT, AND AT lOCATIONS OTHER THAN THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR OPINIONS ON WHETHER THE Fill MEETS SPECIACATlONS. 95 % OF MAXIMUM MOISTURE WITHIN 0 ASTM D 698 SPECIFICATIONS: TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS: CAT CP 563 C SHEEPFOOT VIB. MOISTURE ADDED BY WATER TRUCK TYPE OF EARTH MOVING EQUIPMENT AND NO. OF UNITS: THICKNESS OF LIFT 7" INCHES PROGRESS REPORT AS REQUESTED, A SITE VISIT WAS MADE TO PERFORM COMPACTION AND MOISTURE TESTING FOR LIME STABILIZED SUBGRADE. RE-TESTS AND NEW TESTS WERE PREFORMED ON THE WEST DR., NORTH OF MIDDLE DR. UPON ARRIVAL, RE-TEST AREAS WERE RECOMPACTED AND READY FOR TESTING. FOUR NEW TEST WERE TAKEN ON WEST DR.. WE ADVISED THE CONTRACTOR OF TESTS WHICH FAILED DUE TO LOW COMPACTIVE EFFORT. WE WERE REQUESTED TO RETURN ON 9/30108 FOR ADDITIONAL TESTING. S4A, 5SA. S7A, seA, B6A. 68, 69. 70 o IN OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) o IN OUR OPINION, FILL COMPACTlON DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) 65A, 67 SCOPE OF OBSERVATION: O FULL TIME: o PERIODIC, ON CAlL BASIS; 0 ~~~CTOR'S OR CUENT'S REPRESENTATIVE DEWEY LONG RELD REPRESENTATIVE CTL[THOMPSON TEXAS. C APPROVED BY LH Compaction Test Report ~ CTL I THOMPSON T E X A S. L L C CLIENT: CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 DATE: nQ/?QInR PROJECT NUMBER: DAOR1S? non Phase: 345 REPORT NUMBER: ~ SHEET: -L OF --2..- SUBJECT: ROLLING OAKS MEMORIAL CENTER PHASE I FREEPORT PARKWAY COPPELL, TX 1 LABORATORY FIELD TEST NO. LOCATION DEPTH TEST MAX OMC% DRY MC% COM- SOIL lYPE lYPE DENSllY DENSITY PACTION FEET PCF PCF % CURVE NO 5 54 A RETEST OF TEST 54 NUC 96.0 24.0 91.9 27.1 96 JOB NO DAOB152.DOO CURVE NO 6 55 I. RETEST OF TEST 55 NUC 102.0 20.0 98.5 22.6 97 JOB NO DA08152.000 CURVE NO 5 57 I. RETEST OF TEST 57 NUC 96.0 24.0 90.9 25.4 95 JOB NO DAOB152.000 CURVE NO 6 58 A RETEST OF TEST 58 NUC 102.0 20.0 96.7 20.7 95 JOB NO DAOB152.000 CURVE NO 5 65 I. RETEST OF TEST 65 NUC 96.0 24.0 86.7 30.0 90 JOB NO DA08152.DOO CURVE NO 5 66 A RETEST OF TEST 66 NUC 96.0 24.0 90.9 24.6 95 JOB NO DAOB152.000 WEST DR. FROM INTERSECTION CURVE NO 5 67 OF MIDDLE DR. N. 50' 0.0 NUC 96.0 24.0 84.4 34.1 88 JOB NO DAOB152.000 WEST DR. FROM INTERSECTION CURVE NO 5 68 OF MIDDLE DR. N. 200' 0.0 NUC 96.0 24.0 91.0 28.5 95 JOB NO DA08152.000 WEST DR. FROM INTERSECTION CURVE NO 5 69 OF MIDDLE DR. N. 350' 0.0 NUC 96.0 24.0 91.8 25.7 96 JOB NO DA08152.000 LIME STABILIZED SUBGRADE PREPARATION , BELOW SUBGRADE MOISTURE WITHIN 0 TO +4 ASTM D 698 '" OF OPTIMUM THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF OUR OBSERVATION OF Fill PLACEMENT, AS WEll AS THE TESTS SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO APPLY THE NECESSARY COMPACTlVE EFFORT AND MOISTURE TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR OBSERVER IS NOT PRESENT, AND AT LOCATIONS OTHER THAN THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR OPINIONS ON WHETHER THE FILL MEETS SPECIACATIONS. 95 '" OF MAXIMUM SPECIFICATIONS: TYPE OF COMPACTION EaUIPMENT AND NO. OF UNITS: CAT CP 563 C SHEEPFOOT VIB. WATER TRUCK THICKNESS OF LIFT MOISTURE ADDED BY 7" INCHES TYPE OF EARTH MOVING EaUIPMENT AND NO. OF UNITS: 54A. 55A. 57 A, 58A, aaA. 68, 69. 70 o IN OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) . FIELD REPRESENTATIVE CTLfTHOMPS APPROVEO Y 121 IN OUR OPINION, FILL COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO,(S) SCOPE OF OBSERVATION: O FULL TIME; o PERIODIC, ON CALL BASIS; 121 ~~~CTOR'S OR CLIENTS REPRESENTATIVE DEWEY LONG LH 10575 Newkirk Street, Suite 780 I Dallas, TX 75220 I Phone: 972-831-1111