Loading...
Rolling Oaks MC-LR080924 Field Gradations of Lime Stabilized Sub-Grade Job Number: DA08152.000 Date: 09/24/2008 Project: ROLLING OAKS COG Specifications (item 4.6.6): Location: COPPELL, TEXAS 100% passing 1 3/4" 60% passing NO.4 Location Sample % Passing % Passing wt (Ibs) 1 3/4" Sieve #4 Sieve 50' NORTH OF RUBY DRIVE ENTRANCE 10 100% 75.0 500' NORTH OF RUBY DRIVE ENTRANCE 10 100% 70.0 24' FIRELANE, NORTH OF PHASE II MORTUARY PARKING AREA, WEST END 10 100% 73.0 24' FIRELANE, NORTH OF PHASE II MORTUARY EAST END 10 100% 69.0 Remarks: Compaction Test Report T CTL I THOMPSON T E X A S, l l C CLIENT: CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 DATE: 09l24m8 PROJECT NUMBER: [lAnaiS' nnn Phase: 345 REPORT NUMBER: ~ SHEET:....1..-- OF ......1- SUBJECT: ROLLING OAKS MEMORIAL CENTER PHASE I FREEPORT PARKWAY COPPELL, TX LABORATORY FIELD TEST TEST DRY NO. LOCATION DEPTH MAX OMC% MC% COM- SOIL TYPE FEET TYPE DENSITY DENSITY PACTION PCF PCF % NO TESTS PERFORMED LIME STABILIZED SUBGRADE PREPARATION % OF OPTIMUM THIS REPORT PRESENTS OPIN IONS FORMED AS A RESULT OF OUR OBSERVATION OF FILL PLACEMENT, AS WELL AS THE TESTS SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR OBSERVER IS NOT PRESENT, AND AT LOCATIONS OTHER THAN THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR OPINIONS ON WHETHER THE FILL MEETS SPECIFICATIONS. SPECIFICATIONS: MOISTURE WITHIN % OF MAXIMUM TO TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS: CAT SHEEPSFOOT ROLLER (1) MOISTIJRE ADDED BY TYPE OF EARTH MOVING EQUIPMENT AND NO. OF UNITS: CAT BLADE (1), CAT MIXER (1) THICKNESS OF LIFT INCHES PROGRESS REPORT AS REQUESTED, A SITE VISIT WAS MADE MADE BY A REPRESENTATIVE OF CTLITHOMPSON FOR GRADATIONS OF LIME STABILIZED SUBGRADE. TEST RESULTS APPEAR TO BE SATISFACTORY. THE PROJECT PLANS PROVIDE NO STREET NAMES OR STATION NUMBERS. TEST LOCATIONS ARE APPROXIMATE. o IN OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) o IN OUR OPINION, FILL COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) CHRIS THERIOT AELD REPRESENTATIVE CTL!THOMPSON T APPROVED BY RI E SENIOR PRINCIPAL ~'''-'\,'\.'\.\.'\\'ll. 4r'i;. Of" }~ It ,e. b..~ ........... . j.,. lZ - "'~ ..' *',:0-1 I CHRIS .:;t~ .... ....IS' 'I ~*l ' .....'11'1/ p*: ~ *~ ;t..... ........................... ~ ;.! MMERBERG ~ ,.,. II. ......... ....,.....~ i~H . .'~'" I O~....~!.C~NS~?.... ~~ .:Y I, ~S ......... t.l~" - ~tll:SIONAl ~'I'~"::- . ~\\'\'\"()."'~ SCOPE OF OBSERV A TICH: O FULL TIME; o PERIODIC. ON CALL BASIS; 0 ~=~CTOR'S OR CLIENT'S REPRESENTATIVE 10575 Newkirk Street, Suite 780 I Dallas, TX 75220 I Phone: 972-831-1111