Rolling Oaks MC-LR080811 Compaction Test Report ~ CTL I THOMPSON TEXAS LLC CUENT: CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 DATE: 08111/08 PROJECT NUMBER: nA081li2 nno Phase: 345 REPORT NUMBER: ~ SHEET:...1... OF ---2..- SUBJECT: ROLLING OAKS MEMORIAL CENTER PHASE I FREEPORT PARKWAY COPPEll, TX 1 LABORATORY FIELD TEST NO. LOCATION DEPTH TEST MAX OMC% DRY MC% CDM- SOIL TYPE TYPE DENSITY DENSITY PACTION FEET PCF PCF % 8" WATERLINE, 200' EAST OF CURVE NO 2 26 FREEPORT PARKWAY NW CORNER 2.0 Nue 100.0 22.0 94.5 15.9 95 JOB NO DA08152.000 8" WATERLINE, 200' EAST OF CURVE NO 1 27 FREEPORT PARKWAY NW CORNER 1.0 NUC 105.0 18.0 104.6 15.8 100 JOB NO DA08152.000 8" WATERLINE, 200' EAST OF CURVE NO 3 28 FREEPORT PARKWAY NW CORNER 0.0 Nue 119.0 11.5 110.8 9.0 93 JOB NO DA08152.000 CURVE NO 2 29 8" WATERLINE, STA. 5+00 2.0 Nue 100.0 22.0 82.3 29.2 82 JOB NO DA08152.000 CURVE NO 2 30 8" WATERLINE, STA. 5+00 1.0 NUC 100.0 22.0 94.2 25.2 94 JOB NO DA08152.000 CURVE NO 2 31 8" WATERLINE, STA. 5+00 0.0 NUC 100.0 22.0 93.1 23.2 93 JOB NO DA08152.000 CURVE NO 2 32 8" WATERLINE, STA. 8+00 2.0 NUC 100.0 22.0 79.9 23.6 80 JOB NO DA08152.000 8" WATERLINE, 800' ESAT OF CURVE NO 2 33 FREEPORT PARKWAY NW CORNER 1.0 Nue 100.0 22.0 95.3 19.7 95 JOB NO DA08152.000 CURVE NO 2 34 8" WATERLINE, STA. 8+00 0.0 NUC 100.0 22.0 86.0 21.3 86 JOB NO DA08152.000 WATERLINE TRENCH BACKFILL 1 BELOW SUBGRADE TO +5 ASTM 0 698 % OF OPTIMUM THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF OUR OBSERVATION OF FILL PLACEMENT, AS WELL AS THE TESTS SHOWN ABOVE. WE HAVE RELIED UPON THE CONTRACTOR TO APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR OBSERVER IS NOT PRESENT, AND AT LOCATIONS OTHER THAN THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR OPINIONS ON WHETHER THE FILL MEETS SPECIFICA1l0NS. SPECIFICATIONS: 95 % OF MAXIMUM MOISTURE WITHIN +1 TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS; MOISTURE ADDED BY WATER TRUCK TYPE OF EARTH MOVING EQUIPMENT AND NO. OF UNITS: BACKHOE (1) THICKNESS OF LIFT l' INCHES o IN OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) 38.39 SCOPE OF OBSERVATION: O FULL TIME; III PERIODIC ON CALL BASIS' III CONTRACTOR'S OR CLIENTS REPRESENTATIVE ~ ' ,~ ADVISED I2J IN OUR OPINION, FILL COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) ROBERT GRIFFITHS FIELD REPRESENTATIVE LH 10575 Newkirk Street, Suite 780 I Dallas, TX 75220 I Phone: 972-831-1111 Com paction Test Report T- CTL I THOMPSON T E X A S. L L C CLIENT; CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 DATE; OR/11/08 PROJECT NUMBER: [)AOR1~2 Don Phase: 345 REPORT NUMBER: ~ SHEET:...2.... OF -L SUBJECT: ROLLING OAKS MEMORIAL CENTER PHASE I FREEPORT PARKWAY COPPELL, TX TEST 1 LABORATORY FIELD NO. lOCATION DEPTH TEST MAX OMC% DRY MC% COM- SOil TYPE TYPE DENSITY DENSITY PACTION FEET PCF PCF % CURVE NO 2 35 8" WATERLINE, STA.11+00 2.0 NUC 100.0 22.0 75.1 28.8 75 JOB NO DA08152.000 CURVE NO 2 38 8" WATERLINE, STA. 11+00 1.0 NUC 100.0 22.0 90.3 26.2 90 JOB NO DA08152.000 CURVE NO 2 37 8" WATERLINE, STA. 11+00 0.0 NUC 100.0 22.0 91.5 23.1 92 JOB NO DA08152.000 2" WATER SERVICE LINE CURVE NO 2 38 BURIAL COLUMN 1.5 NUC 100.0 22.0 95.8 25.9 96 JOB NO DA08152.000 2" WATER SERVICE LINE CURVE NO 2 39 BURIAL COLUMN 0.5 NUC 100.0 22.0 95.4 26.1 95 JOB NO DA08152.000 CURVE NO 2 40 FUTURE 2" WATER SERVICE LINE 1.5 NUC 100.0 22.0 91.9 24.8 92 JOB NO DA08152.000 CURVE NO 2 41 FUTURE 2" WATER SERVICE LINE 0.5 NUC 100.0 22.0 84.6 22.4 85 JOB NO DA08152.000 WATERLINE TRENCH BACKFILL 1 BELOW SUBGRAOE SPECIFICATIONS: 95 MOISTURE WITHIN % OF MAXIMUM +1 TO +5 ASTM D 698 % OF OPTIMUM THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF OUR OBSERVATION OF Fill PLACEMENT, AS WEll AS THE TESTS SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR OBSERVER IS NOT PRESENT, AND AT lOCATIONS OTHER THAN THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR OPINIONS ON WHETHER THE Fill MEETS SPECIFICATIONS. TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS: THICKNESS OF LIFT MOISTURE ADDED BY WATER TRUCK lYPE OF EARTH MOVING EQUIPMENT AND NO. OF UNITS: BACKHOE (1) PROGRESS REPORT AS REQUESTED, A SITE VISIT WAS MADE TO PERFORM COMPACTION AND MOISTURE TESTING OF 8" WATERLINE STARTING AT THE NW CORNER OF PROPERTY, 200' EAST OF FREEPORT PARKWAY AND 2" WATER SERVICE LINE. WE ADVISED THE CONTRACTOR OF FAILING TEST LOCATIONS, AND ADVISED THE CONTRACTOR TO APPLY ADDITIONAL COMPACTIVE EFFORT AND TO MOISTURE CONDITION WHERE APPROPRIATE. l' INCHES o IN OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) 38.39 SCOPE OF OBSERVATION; O FULL TIME; ~ PERIODIC ON CALL BASIS' r7I CONTRACTOR'S OR CLIENTS REPRESENTATIVE ~ ' ,~ ADVISED !2IIN OUR OPINION, FILL COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) ROBERT GRIFFITHS LH CTLITHOMPSON TEXAS. LLC APPROVED BY RICH R RB PROJECT ENGINEER 10575 Newkirk Street, Suite 780 I Dallas, TX 75220 I Phone: 972-831-1111 FIELD REPRESENTATIVE