Rolling Oaks MC-LR080626 Compaction Test Report Y CTL I THOMPSON T E X A S. L L C CLIENT: CITY OF COPPELL 255 PARKWAY BOULEVARD P.O. BOX 478 COPPELL TX 75019 DATE: OR/?RtnR PROJECT NUMBER: DAORi"? 000 Phase: 345 REPORT NUMBER: ---L SHEET; ---1- OF ......L SUBJECT: ROLLING OAKS MEMORIAL CENTER PHASE I FREEPORT PARKWAY COPPELL, TX TEST 1 LABORATORY FIELD NO. LOCATION DEPTH TEST MAX OMC"Io DRY MC"Io COM- SOIL TYPE TYPE DENSITY DENSITY PACTION FEET PCF PCF "10 10' SOUTH AND 10' EAST OF THE NWC CURVE NO 3 19 OF THE PAVILLION BUILDING 1.0 NUC 119.0 11.5 117.3 12.1 99 JOB NO DAOa152.000 25' SOUTH AND 40' EAST OF THE NWC CURVE NO 3 20 OF THE PAVILLlON BUILDING 1.0 Nue 119.0 11.5 117.8 11.9 99 JOB NO DAoa152.ooo 5' SOUTH AND 20' EAST OF THE NWC CURVE NO 3 21 OF THE PAVILLION BUILDING 0.0 Nue 119.0 11.5 118.3 11.6 99 JOB NO DAOa152.000 20' SOUTH AND 50' EAST OF THE NWC CURVE NO 3 22 OF THE PAVILLION BUILDING 0.0 Nue 119.0 11.5 118.0 11.9 99 JOB NO DAOa152.000 5' SOUTH AND 10' WEST OF THE NEC CURVE NO 3 23 OF THE COLUMBARIUM BUILDING 0.0 Nue 119.0 11.5 117.0 12.3 98 JOB NO DA08152.000 20' SOUTH AND 30' WEST OF THE NEC CURVE NO 3 24 OF THE COLUMBARIUM BUILDING 0.0 Nue 119.0 11.5 117.3 12.0 99 JOB NO DAoa152.000 30' SOUTH AND 50' WEST OF THE NEC CURVE NO 3 25 OF THE COLUMBARIUM BUILDING 0.0 Nue 119.0 11.5 117.1 12.1 98 JOB NO DAoa152.000 UNDER SLAB FILL 1 BELOW SUBGRADE SPECIFICATIONS: 95 MOISTURE WITHIN % OF MAXIMUM -1 TO +3 ASTM D 698 % OF OPTIMUM THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF OUR OBSERVATION OF FILL PLACEMENT, AS WELL AS THE TESTS SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR OBSERVER IS NOT PRESENT, AND AT LOCATIONS OTHER THAN THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR OPINIONS ON WHETHER THE FILL MEETS SPECIFICATIONS. TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS: MOISTURE ADDED BY TYPE OF EARTH MOVING EQUIPMENT AND NO. OF UNITS; THICKNESS OF LIFT INCHES PROGRESS REPORT AS REQUESTED, A SITE VISIT WAS MADE TO PERFORM COMPACTION AND MOISTURE TESTING ON SELECT FILL PLACED IN THE THE PAVILLlON AND COLUMBARIUM BUILDING. FILL WAS PLACED AND COMPACTED PRIOR TO OUR SITE VISIT. ~ IN OUR OPINION, Fill COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) 19 - 25 o IN OUR OPINION, Fill COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) SF CTLjT1fOMPSON TEXAS, APPROVED BY RIC;6. SCOPE OF OBSERVATION: O FUll TIME; ~ PERIODIC ON CAll BASIS.' ~ CONTRACTOR'S OR CllENrs REPRESENTATIVE ~ . ,~ AOVISED CHRIS THERIOT FIELD REPRESENTATIVE 10575 Newkirk Street, Suite 780 I Dallas, TX 75220 I Phone: 972-831-1111