Chateaus-LR081110 (2) Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Piano, TX 75074 Report No.: 337637 Project No.: 0814523 Date of Service: 10/31/2008 Report Date: 11/10/2008 Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Cylinder Marked Date Age Diameter Area Set No. Tested (days) (in) (in2) 1 1 11/07/2008 7 5.99 28.18 2 11/28/2008 28 3 11/28/2008 28 4 12/26/2008 56 Contractor: Concrete Supplier: Redi-Mix Plant: P259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 0rJ ~[g [rn E;] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Remarks: Water added at site: 5 gallons Mix Design I.D.: 336L 1524 Placement Date: 10/31/2008 Weather Conditions: Sunny Time Sampled: 01 :39pm Temperature - Air: 850F Truck No: 1364 Air Content: 3.3% Overall Placement Location: Paving, staple concrete, Station 1+60, east and west side of Montebello Drive Batch time: 12:39pm Concrete: 800F Ticket No: 59035510 Unit Weight (pet): NA Measured Slump (inches) 4.5 Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Maximum Load (Ibs) 85,920 Compressive Strength (psi) 3,050 Fracture Type Type5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/LB) Page 1 of 2