Loading...
Chateaus-LR081112 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Piano, TX 75074 Report No.: 335952 Project No.: 0814523 Date of Service: 10/14/2008 Report Date: 11/12/2008 Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Concrete Supplier: Redi-Mix Plant: 135 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 3" - 4" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 336L 1524 Placement Date: 10/14/2008 Weather Conditions: Cloudy, light wind Time Sampled: 01 :35pm Batch time: 12:57pm Temperature - Air: 780F Concrete: 850F Truck No: 1293 Ticket No: 59034564 Air Content: 4.9% Unit Weight (pcf): NA Overall Placement Location: Paving, Station 1+62 to 3+30 and 12+60 to 12+80 Measured Slump (inches) 5.0 Sample Location: Station 12+78 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 2 1 10/21/2008 7 6.00 28.27 98,980 8fJ Type2 2 2 11/11/2008 28 5.99 28.18 120,920 Type2 2 3 11/11/2008 28 5.99 28.18 124,080 ,40 Type2 Average I 50 2 4 12/09/2008 56 ~l3 ~~ 5J] lS] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/CL) Page 3 of 5 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Piano, TX 75074 Report No.: 335952 Project No.: 0814523 Date of Service: 10/14/2008 Report Date: 11/12/2008 Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Concrete Supplier: Redi-Mix Plant: 135 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 3" - 4" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 336L 1524 Placement Date: 10/14/2008 Weather Conditions: Cloudy, light wind Time Sampled: 09:01am Batch time: Temperature - Air: 750F Concrete: 870F Truck No: 1020 Ticket No: 13624647 Air Content: 4.6% Unit Weight (pcf): NA Overall Placement Location: Paving, Station 1+62 to 3+30 and 12+60 to 12+80 Measured Slump (inches) 4.25 Sample Location: Station 2+70 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 10/21/2008 7 6.00 28.27 126,110 4460 Type5 ~ 2 11/11/2008 28 5.99 28.18 175,870 Type2 3 11/11/2008 28 5.99 28.18 177,340 Type2 Average 4 12/09/2008 56 ~~ ~[g EIR b] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/CL) Page 1 of 5