Loading...
Chateaus-LR081204 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No..: 335337 Project No.: 0814523 Date of Service: 10/08/2008 ~ . .~ Report Date: 12/04/2008 Project: ateaus ~~ Services: - "mpl'; of f,,," 000"'" al th, p~oam,"1 locallo"" penooo ,,,,,"'red I,,"og, ,..I oomp"",I" "mogth ",mpl" ,,'" I><log samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA .. {ileA Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 5" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 536L 1524 Placement Date: 10/08/2008 Weather Conditions: Clear Time Sampled: 08:06am Temperature - Air: 580F Truck No: 1293 Air Content: 4.3% Overall Placement Location: Paving, Station 13+00 to 0+00 Batch time: 06:53am Concrete: 790F Ticket No: 59033970 Unit Weight (pet): NA Measured Slump (inches) 4.5 Sample Location: Station 12+16 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 10/15/2008 7 5.99 28.18 108,450 3,850 Type2 1 2 11/05/2008 28 5.99 28.18 132,260 tr690 Type3 1 3 11/05/2008 28 5.99 28.18 132,600 __4,710 Type2 Average 4,700 1 4 12/03/2008 56 5.99 28.18 148,340 5,260 Type 3 ~[j ~Q] ~ tJ DO D rl/~/?~ e Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance. etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/eLI Page 1 of 9 Rone Engineering ----- 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No.: 335337 Project No.: 0814523 Date of Service: 10/08/2008 Report Date: 12/04/2008 Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slu'mp (in.): 4" - 5" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 536L 1524 Placement" Date: 10/08/2008 Weather Conditions: Clear Time Sampled: 08:56am Temperature - Air: 590F Truck No: 1216 Air Content: 5.3% Overall Placement Location: Paving, Station 13+00 to 0+00 Batch time: 08:23am Concrete: 750F Ticket No: 59033987 Unit Weight (pet): NA Measured Slump (inches) 4.0 Sample Location: Station 10+50 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type - - 2 1 10/15/2008 7 5.99 28.18 108,740 3,860 Type2 2 2 11/05/2008 28 5.99 28.18 136,500 - 4,840 Type2 2 3 11/05/2008 28 5.99 28.18 132,490 - 4,700 Type2 Average 4,770 2 4 12/03/2008 56 5.99 28.18 146,030 5,180 Type 5 ~EJ ~~ rnJ ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, ltd. (TM/CL) Page 2 of 9 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppel!, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No.: 335337 Project No.: 0814523 Date of Service: 10/08/2008 Report Date: 12/04/2008 Project: Chateaus of Cappel! Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 5" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 536L 1524 Placement Date: 10/08/2008 Weather Conditions: Clear Time Sampled: 10:04am Temperature - Air: 690F Truck No: 1388 Air Content: 4.7% Overall Placement Location: Paving, Station 13+00 to 0+00 Batch time: 09:23am Concrete: 800F Ticket No: 59034000 Unit Weight (pcf): NA Measured Slump (inches) 3.5 Sample Location: Station 9+18 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 3 1 10/15/2008 7 5.99 28.18 106,110 3,770 Type2 3 2 11/05/2008 28 5.99 28.18 134,030 - 4,760 Type3 3 3 11/05/2008 28 5.99 28.18 127,810 ... 4,540 Type2 Average 4,650 3 4 12/03/2008 56 5.99 28.18 145,990 5,180 Type 2 ~ESJ ~Q] fI?J E;] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMIT A nONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/CL) Page 3 of 9 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC c/oLenart Development Co., LLC Report No.: 335337 520 Central Parkway E Project No.: 0814523 Plana, TX 75074 Date of Service: 10/08/2008 Report Date: 12/04/2008 Project: Chateaus of Cappel! Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 5" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design 1.0.: 536L 1524 Placement Date: 10/08/2008 Weather Conditions: Clear Time Sampled: 11 :07am Temperature - Air: 750F Truck No: 1286 Air Content: 4.4% Overall Placement Location: Paving, Station 13+00 to 0+00 Batch time: 10:21am Concrete: 800F Ticket No: 59034014 Unit Weight (pet): NA Measured Slump (inches) 3.0 Sample Location: Station 7+00 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type - 4 1 10/15/2008 7 5.99 28.18 104,940 3,720 Type2 4 2 11/05/2008 28 5.99 28.18 139,280 - 4,940 Type5 4 3 11/05/2008 28 5.99 28.18 134,590 .,.. 4,780 Type4 Average 4,860 4 4 12/03/2008 56 5.99 28.18 151,220 5,370 Type 4 ~t5J ~~ ~ [;J D D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services. Ltd. (TM/CL) Page 4 of 9 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No.: 335337 Project No.: 0814523 Date of Service: 10/08/2008 Report Date: 12/04/2008 Project: Chateaus of Cappel! Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 5 1 10/15/2008 7 5.99 28.18 99,180 3,520 5 2 11/05/2008 28 5.99 28.18 121,240 - 4,300 5 3 11/05/2008 28 5.99 28.18 125,120 ., 4,440 Average 4,370 5 4 12/03/2008 56 5.99 28.18 133,350 4,730 Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 5" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31'(except 10.1.2) . ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~tJ ~Q;] 5ru E] DO D Type 1 Type 2 Type 3 Type 4 Type 5 PROJECT DATA Mix Design 1.0.: 536L 1524 Placement Date: 10/08/2008 Weather Conditions: Clear Time Sampled: 11 :45am Temperature - Air: 790F Truck No: 1321 Air Content: 4.9% Overall Placement Location: Paving, Station 13+00 to 0+00 Batch time: 10:50am Concrete: 810F Ticket No: 59034023 Unit Weight (pet): NA Measured Slump (inches) 4.0 Sample Location: Station 6+80 Fracture Type TypeS Type2 Type2 Type 2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/eL) Page 6 of 9 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppel!, LLC c/o Lenart Development Co., LLC Report No.: 335337 520 Central Parkway E Project No.: 0814523 Plana, TX 75074 Date of Service: 10/08/2008 Report Date: 12/04/2008 Project: Chateaus of Cappel! Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 5" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 PROJECT DATA Mix Design I.D.: 536L 1524 Placement Date: 10/08/2008 Weather Conditions: Clear Time Sampled: 01 :23pm Temperature - Air: 820F Truck No: 1387 Air Content: 4.7% Overall Placement Location: Paving, Station 13+00 to 0+00 Batch time: 12:24pm Concrete: 840F Ticket No: 59034046 Unit Weight (pet): NA Measured Slump (inches) 4.5 Sample Location: Station 2+60 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) . (in') (Ibs) (psi) 6 1 10/15/2008 7 5.99 28.18 98,000 3,480 6 2 11/05/2008 28 5.99 28.18 113,700 -4,030 6 3 11/05/2008 28 5.99 28.18 115,920 _______~11 0 Average 4,070 6 4 12/03/2008 56 5.99 28.18 139,610 4,950 ~~ ~~ fIE E;] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Fracture Type Type2 Type5 Type2 Type 2 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TMlCL) Page 7 of 9