Loading...
Chateaus-LR081201 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC 520. Central Parkway E Piano, TX 75QZ Report No.: 334876 Project No.: 0.814523 Date of Service: 10./0.2/20.0.8 Report Date: 12/0.1/20.0.8 Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,60.0. psi @ 28 days Slump (in.): 3" - 4" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10..1.2) ASTM C-143 ~ ASTM C-231 hi ASTM C-1D64 ASTM C-138 .../ //') ASTM C-39 . fj' ~ 336L1524 Placement Date: 10./0.2/20.0.8 Weather Conditions: Cloudy Time Sampled: 0.8:1 Dam Temperature - Air: 680F Truck No: 1257 Air Content: 4.3% Overall Placement Location: Paving, cul-de-sac, Station 2+53 to Station 14+30 Batch time: D7:31am Concrete: 8DoF Ticket No: 590.33738 Unit Weight (pcf): NA Measured Slump (inches) 5.0. Sample Location: Station 2+17 J2/3/C~ (/8 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 10./0.9/20.0.8 7 5.99 28.18 88,730. 3,150. Type2 1 2 10./30./20.0.8 28 5.99 28.18 121,860. Type2 1 3 10./30./20.0.8 28 5.99 28.18 111,840. ~ Type2 Average ." -4,150 4 11/27/20.0.8 56 5.99 28.18 132,990. 4,720. Type 5 ~ES1 ~~-_:~~ ~ Q DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (LB/CL) Page 1 of 2 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No.: 335002 Project No.: 0814523 Date of Service: 10/03/2008 Report Date: 12/01/2008 Project: Chateaus of Cappel! Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Set No. Tested (days) (in) (in') (Ibs) (psi) 1 1 10/10/2008 7 5.99 28.18 82,880 2,940 1 2 10/31/2008 28 5.99 28.18 113,370 c'J5 1 3 10/31/2008 28 5.99 28.18 115,040 Average ,05 4 11/28/2008 56 5.99 28.18 123,080 , 0 Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 3" - 4" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 ~PJ ~Q] Q] lSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Mix Design I.D.: 336L 1524 Placement Date: 10/03/2008 Weather Conditions: Cloudy Time Sampled: 08:06am Temperature - Air: 670F Truck No: 1321 Air Content: 4.2% Overall Placement Location: Paving, cul-de-sac, Station 3+58 to Station 1 +94 Measured Slump (inches) 6.5 Batch time: 07:15am Concrete: 770F Ticket No: 59033863 Unit Weight (pcf): NA Sample Location: Station 2+50 Fracture Type Type2 Type2 Type2 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (ADW/CL) Page 1 of 2 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No.: 337637 Project No.: 0814523 Date of Service: 10/31/2008 Report Date: 12/01/2008 Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Concrete Supplier: Redi-Mix Plant: P259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 336L 1524 Placement Date: 10/31/2008 Weather Conditions: Sunny Time Sampled: 01 :39pm Temperature - Air: 850F Truck No: 1364 Air Content: 3.3% Overall Placement Location: Paving, staple concrete, Station 1 +60, east and west side of Montebello Drive Batch time: 12:39pm Concrete: 800F Ticket No: 59035510 Unit Weight (pcf): NA Measured Slump (inches) 4.5 Sample Location: Same as above REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 1 1 11/07/2008 7 5.99 28.18 85,920 6 TypeS 1 2 11/28/2008 28 5.99 28.18 115,430 Type 2 1 3 11/28/2008 28 5.99 28.18 128,610 Type 5 Average 4 12/26/2008 56 ~E3 ~[!;] ~ b] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Remarks: Water added at site: 5 gallons Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/CL) Page 1 of 2