Loading...
Chateaus-LR081209 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 :/ Date of Service: 10/10/2008 ~ Report Date: 12/09/2008 Project: Chat u ell Services: Obtai samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Report No.: Project No.: 335627 0814523 PROJECT DATA Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 2" - 4" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 536C1524 Placement Date: 10/10/2008 Weather Conditions: Partly cloudy, sunny Time Sampled: 09:15am Batch time: 08:14am Temperature - Air: 780F Concrete: 750F Truck No: 1336 Ticket No: 59034341 Air Content: 3.5% Unit Weight (pet): NA Overall Placement Location: Montebello Drive, Station 12+15. Station 14+00, Chalais Court on south of eyebrow corners, Station 8+00, "continued" Measured Slump (inches) 4.75 Sample Location: Montebello Drive, Station 12+15 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 10/17/2008 .~ 5.99 28.18 108,860 3,860 Type2 1 2 11/07/2008 5.99 28.18 136,440 ~ Type4 1 3 11/07/2008 5.99 28.18 138,250 Type6 Average , 0 1 4 12/05/2008 56 6.00 28.27 152,590 5,400 Type 5 [8]t:j ~[g 5ru lSJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 , fI/v I L ) /'7/ ~S rt LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KP/KP) Page 1 of 7 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No.: 335627 Project No.: 0814523 Date of Service: 10/10/2008 Report Date: 12/09/2008 Project: Chateaus of Cappel! Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 2" - 4" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 536C1524 Placement Date: 10/10/2008 Weather Conditions: Partly cloudy, sunny Time Sampled: 10:45am Batch time: 10:04am Temperature - Air: 800F Concrete: 780F Truck No: 1348 Ticket No: 59034364 Air Content: NA Unit Weight (pct): NA Overall Placement Location: Montebello Drive, Station 12+15, Station 14+00, Chalais Court on south of eyebrow corners, Station 8+00, "continued" Measured Slump (inches) 2.75 Sample Location: Montebello Drive, Station 14+00 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type - 2 1 10/17/2008 7 5.99 28.18 114,710 4,070 Type2 2 2 11/07/2008 28 5.99 28.18 146,920 5,210 Type2 2 3 11/07/2008 28 5.99 28.18 143,910 5,110 TypeS Average 5,160 2 4 12/05/2008 56 6.00 28.27 148,210 5,240 Type 2 B]~ ~~ 51] lJ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KPIKP) Page 3 of 7 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No.: 335627 Project No.: 0814523 Date of Service: 10/10/2008 Report Date: 12/09/2008 Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Concrete Supplier: Redi-Mix Plant: 259 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 2" - 4" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 536C1524 Placement Date: 10/10/2008 Weather Conditions: Partly cloudy, sunny Time Sampled: 12:30pm Batch time: 11 :53am Temperature - Air: 900F Concrete: 810F Truck No: 1364 Ticket No: 59034341 Air Content: 4.2% Unit Weight (pet): NA Overall Placement Location: Montebello Drive, Station 12+15. Stalion 14+00, Chalais Court on south of eyebrow corners, Slation 8+00, "continued" Measured Slump (inches) 3.25 Sample Location: Chailais Court, south of eyebrow corners, Station 8+00, Station 9+00 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type - 3 1 10/17/2008 7 5.99 28.18 104,390 3,700 Type5 3 2 11/07/2008 28 5.99 28.18 128,670 4,570 Type6 3 3 11/07/2008 28 5.99 28.18 122,460 4,350 Type5 Average 4,460 3 4 12/05/2008 56 6.00 28.27 139,850 4,950 Type 2 ~EJ ~[g fill] ~ D D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (KP/KP) Page 5 of 7