Chateaus-LR081223 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC Report No.: 336970 520 Central Parkway E Project No.: 0814523 Plana, TX 75074 Date of Service: 10/24/2008 Report Date: 12/23/2008 Client: Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Concrete Supplier: LMC Plant: 07 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 5" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 1701 Placement Date: 10/24/2008 Weather Conditions: Clear Time Sampled: 10:15am Temperature - Air: 680F Truck No: 9153 Air Content: . 4.6% Overall Placement Location: Northbound on Benchmark St., Station 1+00 to 6+50 Measured Slump (inches) 3.75 Batch time: 09:30am Concrete: 720F Ticket No: 7199393 Unit Weight (pet): NA Sample Location: Northbound on Benchmark St., Station 3+65 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 2 1 10/31/2008 7 5.99 28.18 114,720 4,070 Type6 2 2 11/21/2008 28 5.99 28.18 152,120 5,400 Type2 2 3 11/21/2008 28 5.99 28.18 150,910 5,360 Type2 Average 5,380 2 4 12/19/2008 56 6.00 28.27 184,240 6,520 Type 3 ~E3 ~~ t] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMIT A TIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KP) Page 3 of 7 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 7701 W Little York, Ste 600, Houston, TX 77040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Client: Report of Concrete Compressive Strength Test CTM-Coppell, LLC c/o Lenart Development Co., LLC 520 Central Parkway E Plana, TX 75074 Report No.: 336970 Project No.: 0814523 Date of Service: 10/24/2008 Report Date: 12/23/2008 Project: Chateaus of Coppell Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Concrete Supplier: LMC Plant: 07 Specification Requirements Strength: 3,600 psi @ 28 days Slump (in.): 4" - 5" Air (%): 4% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design 1.0.: 1701 Placement Date: 10/24/2008 Weather Conditions: Clear Time Sampled: 11 AOam Temperature - Air: 820F Truck No: 1063 Air Content: 5.3% Overall Placement Location: Northbound on Benchmark St., Station 1+00 to 6+50 Meas u red Slump (inches) 5.25 Batch time: 11 :20am Concrete: 760F Ticket No: 7199409 Unit Weight (pet): NA Sample Location: Northbound on Benchmark St., Station 6+20 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in2) (Ibs) (psi) Type 3 1 10/31/2008 7 5.99 28.18 96,710 3,430 Type2 3 2 11/21/2008 28 5.99 28.18 126,490 4,490 Type5 3 3 11/21/2008 28 5.99 28.18 127,770 4,530 Type2 Average 4,510 3 4 12/19/2008 56 6.00 28.27 180,420 6,380 Type 3 [8]E3 ~[g 5J] t;] DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/KP) Page 5 of 7