Rolling Oaks MC-LR081013
Compa~tion
Test Report
1f CTL I THOMPSON
TEXAS LLC
CLIENT: S.E. CEMETERIES OF TEXAS
523 S. MAIN STREET
GRAPEVINE TX 76051
DATE: 10/13/OR PROJECT NUMBER: DAOR25S 000
Phase: 345 REPORT NUMBER: ~ SHEET: -L OF ~
SUBJECT: RESTLAND FUNERAL HOME
ROLLING OAKS MEMORIAL CENTER
COPPELL, TX
1 LABORATORY FIELD
TEST
NO. LOCATION DEPTH TEST MAX OMC% DRY MC% COM- SOIL TYPE
TYPE DENSITY DENSITY PACTION
FEET PCF PCF %
BUILDING AREA, 10' SOUTH AND 20' CURVE NO 2
11 EAST OF THE NW CORNER 4.0 NUC 107.0 18.0 102.8 21.4 96 JOB NO DA08255.000
BUILDING AREA, 20' SOUTH AND 60' CURVE NO 2
12 EAST OF THE NW CORNER 4.0 NUC 107.0 18.0 103.0 21.3 96 JOB NO DA08255.000
BUILDING AREA,S' SOUTH AND 30' CURVE NO 2
13 EAST OF THE NW CORNER 3.0 NUC 107.0 18.0 102.6 21.5 96 JOB NO DA08255.000
BUILDING AREA, 20' SOUTH AND 70' CURVE NO 2
14 EAST OF THE NW CORNER 3.0 NUC 107.0 18.0 102.1 22.9 95 JOB NO DA08255.000
BUILDING AREA, 15' SOUTH AND 10' CURVE NO 2
15 EAST OF THE NW CORNER 2.0 NUC 107.0 18.0 102.4 22.7 96 JOB NO DA08255.000
BUILDING AREA, 20' SOUTH AND 50' CURVE NO 2
16 EAST OF THE NW CORNER 2.0 NUC 107.0 18.0 102.3 22.8 96 JOB NO DA08255.000
UNDER SLAB FILL
1 BELOW SUBGRADE
MOISTURE WITHIN +3
TO +6
% OF OPTIMUM
THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF
OUR OBSERVATION OF FILL PLACEMENT, AS WELL AS THE TESTS
SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO
APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE
TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR
OBSERVER IS NOT PRESENT, AND AT LOCATIONS OTHER THAN
THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR
OPINIONS ON WHETHER THE FILL MEETS SPECIFICATIONS.
94
% OF MAXIMUM
ASTM D 698
SPECIFICATIONS:
TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS:
MOISTURE ADDED BY
WATER TRUCK
THICKNESS OF LIFT
12
INCHES
TYPE OF EARTH MOVING EQUIPMENT AND NO. OF UNITS:
CAT 963 LOADER (1)
PROGRESS REPORT
AS REQUESTED, A SITE VISIT WAS MADE TO PERFORM COMPACTION AND MOISTURE TESTING FOR THE
UNDER SLAB FILL. WE OBSERVED THE CONTRACTOR PLACING FILL, ADDING MOISTURE AND
COMPACTING WITH THE LOADER.
1ZI1N OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S)
11 -16
o IN OUR OPINION, FILL COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S)
SCOPE OF
OBSERVATION:
O FULL
TIME;
<2"''''\'\~'\'h l
,.... ~ OF .~ 1
..:--~ ~~..........l c.f: t1ll
CHRIS .:::' .... .... I,
~ '* .' ", ~
;:{*' ~.; \*~
::t.,. .... .................l.!';.~
. AfVlfVlER8ERG ~
RI H ME P~ ......'.....~
'I .' -00610 .. ;:
SENIOR PRINCIPAL ~/ o;....././ 0 .....'$5
i, ~ ...~E'NSe:.... ~ .:;'
10575 Newkirk Street, Suite 780 I Dallas, TX 75220 I Phone: 972-831-1111 IZl J'SloiiAl..t.~\)~~
l\\\'\'\"a.,...."........
r7I PERIODIC ON CALL BASIS' r7I CONTRACTOR'S OR CLIENTS REPRESENTATIVE
~ ' ,~ ADVISED
CHRIS THERIOT
FIELD REPRESENTATIVE
SF