Rolling Oaks MC-LR081021 Compaction Test Report 9~ CTL I THOMPSON TEXAS LLC CLIENT: S.E. CEMETERIES OF TEXAS 523 S. MAIN STREET GRAPEVINE TX 76051 DATE: 10/21/0R PROJECT NUMBER: DAOR255 000 Phase: 345 REPORT NUMBER: -L SHEET: -i... OF ~ SUBJECT: RESTLAND FUNERAL HOME ROLLING OAKS MEMORIAL CENTER COPPELL, TX 1 LABORATORY FIELD TEST NO. LOCATION DEPTH TEST MAX OMC% DRY MC% COM- SOIL TYPE TYPE DENSITY DENSITY PACTION FEET PCF PCF % BUILDING AREA, 10' SOUTH AND 20' CURVE NO 3 59 EAST OF THE NW CORNER 0.5 NUC 120.0 11.0 118.1 12.1 98 JOB NO DA08255.000 BUILDING AREA, 10' SOUTH AND 70' CURVE NO 3 60 EAST OF THE NW CORNER 0.5 NUC 120.0 11.0 118.5 11.8 99 JOB NO DA08255.000 BUILDING AREA, 50' SOUTH AND 30' CURVE NO 3 61 EAST OF THE NW CORNER 0.5 NUC 120.0 11.0 119.0 11.6 99 JOB NO DA08255.000 BUILDING AREA, 60' SOUTH AND 80' CURVE NO 3 62 EAST OF THE NW CORNER 0.5 NUC 120.0 11.0 119.1 11.5 99 JOB NO DA08255.000 BUILDING AREA, 100' SOUTH AND 50' CURVE NO 3 63 EAST OF THE NW CORNER 0.5 NUC 120.0 11.0 118.4 11.8 99 JOB NO DA08255.000 BUILDING AREA, 130' SOUTH AND 10' CURVE NO 3 64 EAST OF THE NW CORNER 0.5 NUC 120.0 11.0 118.2 12.0 99 JOB NO DA08255.000 UNDER SLAB FILL 1 BELOW SUBGRADE MOISTURE WITHIN -1 TO +3 % OF OPTIMUM THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF OUR OBSERVATION OF FILL PLACEMENT, AS WELL AS THE TESTS SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR OBSERVER IS NOT PRESENT, AND AT LOCATIONS OTHER THAN THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR OPINIONS ON WHETHER THE FILL MEETS SPECIFICATIONS. 95 % OF MAXIMUM SPECIFICATIONS: ASTM 0 698 TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS: MOISTURE ADDED BY WATER TRUCK THICKNESS OF LIFT 12 INCHES TYPE OF EARTH MOVING EQUIPMENT AND NO. OF UNITS: CAT 963 LOADER (1) PROGRESS REPORT AS REQUESTED, A SITE VISIT WAS MADE TO PERFORM COMPACTION AND MOISTURE TESTING FOR SELECT FILL PLACEMENT. WE OBSERVED DELIVERY, PLACEMENT AND COMPACTION WITH THE LOADER. 121 IN OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S} 59 - 64 o IN OUR OPINION, FILL COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S} SF CTLITHOMPSON TEXAS, LLC APPROVED BY RICHA SENIOR P SCOPE OF OBSERVATION: O FULL TIME; ~ PERIODIC ON CALL BASIS' ~ CONTRACTOR'S OR CLIENTS REPRESENTATIVE CH RIS ~ ' ,~ ADVISED CHRIS THERIOT FIELD REPRESENTATNE 10575 Newkirk Street, Suite 780 I Dallas, TX 75220 I Phone: 972-831-1111