Chateaus-LR090127 Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 1701 W Little York, Ste 600, Houston, TX 17040 4421 Freidrich, Ste 195, Austin, TX 78744 Corporate Phone: (214) 630-9745 Report of Concrete Compressive Strength Test Client: CTM-Coppell, LLC c/o Lenart Development C LL Report No.: 341708 520 Central Park Project No.: 0814523 Piano, TX 7 Date of Service: 12/29/2008 Report Date: 01/27/2009 Project: Chat u of Copg,e' I Services: Obtain amples of J"'h concrete at the placement ocations, perform required testing, cast compressive strength samples and bring sample back to fie laboratory for curing and testing in accordance with applicable standards. PROJECT DATA Contractor: Concrete Supplier: Lattimore Plant: 7 Specification Requirements Strength: 4,500 psi @ 28 days Slump (in.): 3" - 5" Air (%): 3% - 6% Test Method: ASTM C-172 ASTM C-31 (except 10.1.2) ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 Mix Design I.D.: 1851 Placement Date: 12/29/2008 Weather Conditions: Sunny Time Sampled: 10:15am Temperature - Air: 580F Truck No: 7059 Air Content: 4.4% Overall Placement Location: Paving, southbound lanes (2 right lanes) on Denton Tap Road, 100' south of Bethel Avenue Batch time: 09:42am Concrete: 600F Ticket No: 7201775 Unit Weight (pcf): NA Measured Slump (inches) 3.75 Sample Location: Paving REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (in') (Ibs) (psi) Type 1 1 01/05/2009 7 6.00 28.27 118,180 4,180 Type 2 1 2 01/26/2009 28 6.00 28.27 165,470 Efl Type 5 1 3 01/26/2009 28 6.00 28.27 161,720 20 Type 2 Average 5,790 4 02/23/2009 56 ~tJ ~[g 51] ~ DO D Type 1 Type 2 Type 3 Type 4 Type 5 Remarks: Water added at site: 5 gallons Type 6 (/I~ 'IZ1/ Z~ q LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (TM/JB) Page 1 of 2