Duke Lesley 3C-LR090425 ALPHA~TESTlNG 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com REPORT OF FIELD COMPACTION TESTS TESTED FOR: Duke Construction Limited Partnership Dallas, Texas DATE: 04/25/09 PROJECT: Point West I Expansion Coppell, Texas OUR REPORT NO,: 090238-8 TEST DATA: TECHNICIAN: J,R. TEST ~ SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT" NO, DEPTH NUMBER % PCF % PCF COMPACTION 45 04/25/09 SG 1 20,8 102,1 21,6 101 99 2-A 46 04/25/09 SG 1 20,8 102,1 22,0 102 100 2-A 47 04/25/09 SG 1 20,8 102,1 21,1 98 96 2-A 48 04/25/09 SG 1 20.8 102,1 22,0 100 98 2-A 49 04/25/09 SG 1 20,8 102,1 23.7 97 95 2-A 50 04/25/09 SG 1 20,8 102.1 21.2 98 96 2-A 51 04/25/09 SG 1 20,8 102,1 20,9 101 99 2-A TEST LOCATION: Paving 45 New Parking Lot, 20' Wand 30' S from the NE Corner of the Parking Lot 46 New Parking Lot, 80' Wand 80' S from the NE Corner of the Parking Lot 47 New Parking Lot, 60' Wand 180' S from the NE Corner of the Parking Lot 48 New Parking Lot, 40' Wand 250' S from the NE Corner of the Parking Lot 49 New Parking Lot, 30' Wand 320' S from the NE Corner of the Parking Lot 50 New Parking Lot, 20' E and 50' S from the NW Corner of the Parking Lot 51 New Parking Lot, 80' E and 120' S from the NW Corner of the Parking Lot 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED . A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C, PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D, RETEST Respectfully Submitted, CJ-f}L W ~ Christopher W. Eddy, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. ALPHA~TESTING 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com REPORT OF FIELD COMPACTION TESTS TESTED FOR: Duke Construction Limited Partnership Dallas, Texas DATE: 04/25/09 PROJECT: Point West I Expansion Coppell, Texas OUR REPORT NO.: 090238-8A TEST DATA: TECHNICIAN: J.R. TEST ~ SOIL 10 OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT" % PCF % PCF 52 04/25/09 SG 1 20.8 102.1 22.4 100 98 2-A 53 04/25/09 SG 1 20.8 102.1 21.6 99 97 2-A 54 04/25/09 SG 1 20.8 102.1 21.1 102 100 2-A 55 04/25/09 SG 1 20.8 102.1 23.2 97 95 2-A 56 04/25/09 SG 1 20.8 102.1 23.5 99 97 2-A 57 04/25/09 SG 1 20.8 102.1 21.1 99 97 2-A 58 04/25/09 SG 1 20.8 102.1 23.2 97 95 2-A TEST LOCATION: Paving 52 New Parking Lot, 40' E and 180' S from the NW Corner of the Parking Lot 53 New Parking Lot, 100' E and 310' S from the NW Corner of the Parking Lot 54 New Parking Lot, 50' E and 250' S from the NW Corner of the Parking Lot 55 New Parking Lot, 80' Nand 20' E from the SW Corner of the Parking Lot 56 New Parking Lot, 150' Nand 80' E from the SW Corner of the Parking Lot 57 New Parking Lot, 300' Nand 40' E from the SW Corner of the Parking Lot 58 New Parking Lot, 200' Nand 100' E from the SW Corner of the Parking Lot 1. FILL 2. NATURALSUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED "A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST Respectfully Submitted, C-Lf}L W. ~ Christopher W. Eddy, P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced andlor distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested andlor observed, and are not indicative of the qualities of apparently identical or similar specimens. ALPHA~nSTING 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com REPORT OF FIELD COMPACTION TESTS TESTED FOR: Duke Construction Limited Partnership Dallas, Texas DATE: 04/25/09 PROJECT: Point West I Expansion Coppell, Texas OUR REPORT NO.: 090238-88 TEST DATA: TECHNICIAN: J.R. TEST ~ SOIL 10 OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT. NO. % PCF % PCF 59 04/25/09 SG 1 20.8 102.1 21.2 101 99 2-A 60 04/25/09 SG 1 20.8 102.1 23.0 97 95 2-A 61 04/25/09 SG 1 20.8 102.1 21.4 99 97 2-A 62 04/25/09 SG 1 20.8 102.1 22.9 99 97 2-A 63 04/25/09 SG 1 20.8 102.1 23.1 100 98 2-A 64 04/25/09 SG 1 20.8 102.1 21.5 98 96 2-A TEST LOCATION: Paving 59 New Parking Lot, 100' Nand 30' E from the SW Corner of the Parking Lot 60 New Parking Lot, 30' Wand 20' N from the SE Corner of the Parking Lot 61 New Parking Lot, 10' Wand 70' N from the SE Corner of the Parking Lot 62 New Parkin!=! Lot, 80' Wand 280' N from the SE Corner of the Parking Lot 63 New Parking Lot, 50' Wand 200' N from the SE Corner of the Parking Lot 64 New Parking Lot, 90' Wand 320' N from the SE Corner of the Parking Lot 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED . A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST Respectfully Submitted, CJ-+}L W. ~ Christopher W. Eddy. P.E. ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on fite in our office) and shall not be reproduced and/or distributed except wilh express approval of ALPHA The use of our name and test results must receive our written approval. Test resulls and reports apply only to lhe samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.