Rolling Oaks MC-LR081219 ClIENT: S.E. CEMETERIES OF TEXAS 523 S. MAIN STREET GRAPEVINE TX 76051 Phase: 345 REPORT NUMBER: 14 SHEET: -1- OF --1..- SUBJECT: RESTLAND FUNERAL HOME ROLLING OAKS MEMORIAL CENTER COPPELL, TX LIME STABILIZED SUBRADE PREPARATION 1 LABORATORY FIELD TEST TEST MAX DRY COM- SOIL TYPE NO. LOCATION DEPTH TYPE DENSITY OMC% DENSITY MC% PACTION FEET PCF PCF % PAVING, 20' SOUTH AND 5' EAST CURVE NO 5 OF THE SW CORNER OF THE BUILDING 0.0 NUC 96.0 24.0 95.3 24.4 99 -- 74 JOB NO DA08152.000 PAVING, 10' SOUTH AND 30' EAST CURVE NO 5 --oi=THE SE CORNER OF THE BUILDING 0.0 NUC 96.0 24.0 95.0 24.6 99 ------ 75 JOB NO DA08152.000 PAVING, 15' SOUTH AND 10' EAST CURVE NO 5 76 OF THE NE CORNER OF THE BUILDING 0.0 NUC 96.0 24.0 95.6 24.1 100 JOB NO DA08152.000 1 BELOW SUBGRADE SPECIFICATIONS: 95 ASTM 0 698 THIS REPORT PRESENTS OPINIONS FORMED AS A RESULT OF OUR OBSERVATION OF FILL PLACEMENT, AS WELL AS THE TESTS SHOWN ABOVE, WE HAVE RELIED UPON THE CONTRACTOR TO APPLY THE NECESSARY COMPACTIVE EFFORT AND MOISTURE TO ACHIEVE SPECIFIED COMPACTION DURING TIMES WHEN OUR OBSERVER IS NOT PRESENT, AND AT LOCATIONS OTHER THAN THOSE TESTED. TEST DATA ARE NOT THE SOLE BASIS FOR OPINIONS ON WHETHER THE FILL MEETS SPECIFICATIONS. % OF MAXIMUM MOISTURE WITHIN o TO +4 % OF OPTIMUM TYPE OF COMPACTION EQUIPMENT AND NO. OF UNITS: THICKNESS OF LIFT INCHES MOISTURE ADDED BY TYPE OF EARTH MOVING EQUIPMENT AND NO. OF UNITS: PROGRESS REPORT AS REQUESTED, A SITE VISIT WAS MADE TO PERFORM COMPACTION AND MOISTURE TESTING FOR THE LIME STABILIZED SUBGRADE. THE SUBGRADE HAD BEEN COMPACTED PRIOR TO OUR SITE VISIT. 74 - 76 o IN OUR OPINION, FILL COMPACTION MEETS SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) o IN OUR OPINION, FILL COMPACTION DOES NOT MEET SPECIFICATIONS AS INDICATED BY OUR OBSERVATIONS AND TEST NO.(S) .~......., . ...............;....;:. oTI.~~\ll ....,~:\~..X{..r III gc, :.... ....10' 1/ /~ +.,' ""I:!...._.. . 't_.._ I)