Duke Lesley 3C-LR090528 ~ ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 ----x Concrete Compression Test <-"-j" Report Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Our Report No.: 090238-25 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: Sample Location: SOUTH PORTION OF PARKING LOT FROM SOUTH EDGE TO ABOUT 250'N 30'E & 110'N OF SW CORNER OF PARKING LOT Date Placed: 5/28/2009 Time Placed: 9:35 AM Slump (ASTM C-143): 5.5 Air Content: 4.75 (ASTM C-173) Air Temperature: 78 Specimen Temperature: 87 Date Received: 5/29/2009 Field Data Submitted By: Wright, DaJuan Mix Data Submitted By: TXI Plant Number: Delivery Ticket No.: Mix ID: Made By: 141 871264 8205 ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 33 LAB 1 C-1231 6/4/2009 7 12 N/A 6 28.27 95770 3390 34 LAB 1 6/25/2009 28 12 N/A 6 28.27 0 35 LAB 1 6/25/2009 28 12 N/A 6 28.27 0 36 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 I------------------~-- I Specifications: I ---- ------- -~._-~._-_._-- i Results to Date: 28 4000 N/A CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, L TD Respectfully Submitted By: ~?- of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. (3eotechnical Engineering · Con.str'uction'Materials Testing · _ Envir,~iuT1ent3J ~.rigi!,!eering . Con.~!:l~ting 97684 ~ ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test <-._>~ Report Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Our Report No.: 090238-26 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: Sample Location: SOUTH PORTION OF PARKING LOT FROM SOUTH EDGE TO ABOUT 250'N 75'E & 155'N OF SW CORNER OF PARKING LOT Date Placed: 5/28/2009 Time Placed: 10:49 AM Slump (ASTM C-143): 4.75 Air Content: 3.5 (ASTM C-173) Air Temperature: 70 Specimen Temperature: 85 Date Received: 5/29/2009 Field Data Submitted By: Wright, DaJuan Mix Data Submitted By: TXI Plant Number: Delivery Ticket No.: Mix ID: Made By: 131 871373 8205 ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 37 LAB 1 C-1231 6/4/2009 7 12 N/A 6 28.27 115600 4090 38 LAB 1 6/25/2009 28 12 N/A 6 28.27 0 39 LAB 1 6/25/2009 28 12 N/A 6 28.27 0 40 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 c- [Specifications: -~-------~---- Results to Date: 28 4000 N/A CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, L TD Respectfully Submitted By: ~?- of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. :if .->",. ~......' ::r.~ ',f-.' ".!- "'~ .' .?,< ~" '..~. .'.'~r- d' '''If'' _ T "._" ..,'" '<.:, c. ,'j' " Geq~echnicaIEngineering}' Construction. Material~ Te.,sting * EnyironrrMmtal Engineering · Cons,ultifl9 97685 ~ ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Concrete Compression Test ex Report Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP A TTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Our Report No.: 090238-24 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: Sample Location: SOUTH PORTION OF PARKING LOT FROM SOUTH EDGE TO ABOUT 250'N 20'E & 80'N OF SW CORNER OF PARKING LOT Date Placed: 5/28/2009 Time Placed: 8:35 AM Slump (ASTM C-143): 5.25 Air Content: 5.75 (ASTM C-173) Air Temperature: 65 Specimen Temperature: 85 Date Received: 5/29/2009 Field Data Submitted By: Wright, DaJuan Mix Data Submitted By: TXI Plant Number: Delivery Ticket No.: Mix ID: Made By: 141 871164 8205 ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 29 LAB 1 C-1231 6/4/2009 7 12 N/A 6 28.27 99560 3520 30 LAB 1 6/25/2009 28 12 N/A 6 28.27 0 31 LAB 1 6/25/2009 28 12 N/A 6 28.27 0 32 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 ~---- ------~------ --~ Specifications: ----------.-- Results to Date: 28 4000 N/A CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, L TD Respectfully Submitted By: ~?- of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. ~ .~ Geotechnl'cal. Engineerlng-. Construction ~aJetials;T~iti~g~~En'yirorimental ";ngineering · Consu~ing, 97683 ~ ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 ("'x Concrete Compression Test .,...~" Report Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Our Report No.: 090238-11 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: Sample Location: PAVEMENT PATCH WEST OF BUILDING ELECTRICAL EASEMENT FROM E TO W & DIAGONAL N TO S Date Placed: 5/8/2009 Time Placed: 8:15 AM Slump (ASTM C-143): 4.25 Air Content: 5.1 (ASTM C-173) Air Temperature: 75 Specimen Temperature: 80 Date Received: 5/9/2009 Field Data Submitted By: Shockley, Brent Mix Data Submitted By: TXI Plant Number: Delivery Ticket No.: Mix ID: Made By: 141 863071 8273 ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Break Cap No.: Type: Type: Spec: 9 LAB 1 C-1231 10 LAB C-1231 11 LAB C-1231 12 LAB Specifications: Results to Date: Date Age Avg. Avg. Avg Depth/ Area: Tested: (Days): Length Width Diameter Sq. In. 5/15/2009 7 12 N/A 6 28.27 6/5/2009 28 12 N/A 6 28.27 6/5/2009 28 12 N/A 6 28.27 HOLD HOLD 12 N/A 6 28.27 28 Max Load: 98970 o CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Enginee Concrete, L TD xcavation Ltd., Potter Respectfully Submitted By: ~?- of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except wit:, express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnical Engineering' Construction Materials Testing ~pEnvironmental Engineering · Consul!ing 96871