Duke Lesley 3C-LR090605 (2)ALPHA TESTING, INC. ~ ~C 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 Re ort (972) 620-8911 p Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-42 ATTN: JOHN WARREN `^-µ•~°^"' 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: PAVING, FROM SE CORNER (2ND HALF) TO 330' TOWARDS NORTH Sample Location: 100'N & 20'W FROM SE CORNER OF SW PARKING LOT Date Placed: Time Placed: Slump (ASTM C-143): Air Content: 6/5/2009 7:59 AM 6.5 5.0 (ASTM C-173) ~"1~ Plant Number: 131 Air Temperature: 70 Specimen Temperature: 80 Delivery Ticket No.: 875069 Mix ID: 8205 Made By: ALPHA Cured Specification: ASTM C-31 Date Received: 6/6/2009 /l~ Field Data Submitted By: Wright, DaJuan ~ ~ (. Mix Data Submitted By: TXI CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Break Type: Cap Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq.ln. Max Load: PSI: 85 LAB 1 C-1231 6/12/2009 7 12 N/A 6 28.27 91330 3230 86 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 127650 4520 87 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 121380 -+~90' 88 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 4000 Results to Date: PASS CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, LTD Respectfully Submitted By: ~~ !~ of Alpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. * _.. _... ~ Geotechnical Engineering * Construction Materials Testing " Environmental Engineering * Consulting ~. _ 98037 ALPHA TESTING, INC. <~ 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 (972) 620-8911 Report Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-43 ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: PAVING, FROM SE CORNER (2ND HALF) TO 330' TOWARDS NORTH Sample Location: 150'N & 15'W FROM SE CORNER OF SW PARKING LOT Date Placed: 6/5/2009 Plant Number: 131 Time Placed: 9:02 AM Delivery Ticket No.: 875135 Slump (ASTM C-143): 6.75 Mix ID: 8205 Air Content: 3.25 (ASTM C-173) Made By: ALPHA Air Temperature: 72 Cured Specification: ASTM C-31 Specimen Temperature: 80 Date Received: 6/6/2009 Field Data Submitted By: Wright, DaJuan Mix Data Submitted By: TXI CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Break Type: Cap Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq.ln. Max Load: PSI: 89 LAB 1 C-1231 6/12/2009 7 12 N/A 6 28.27 99630 3520 90 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 119400 4220 91 LAB 1 C-1231 7!3/2009 28 12 N/A 6 28.27 114780 x.4060 92 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 Specifications: Results to Date: 28 4000 PASS CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavat~ Ltd., Potter Concrete, LTD Respectfully Submitted By: ~.-~ ~ of Alpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on f le in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested andlor observed. and are not indicative of the qualities of apparently identical or similar specimens. d ~ Geotechnical Engineering "Construction Materials Testing " Environmental Enpineerin~ • Gonsulting „~, 98038 ALPHA TESTING, INC. <~ 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 (972) 620-8911 Report Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-44 ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: PAVING, FROM SE CORNER (2ND HALF) TO 330' TOWARDS NORTH Sample Location: 185'N & 30'W FROM SE CORNER OF SW PARKING LOT Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Field Data Submitted By Mix Data Submitted By: 6/5/2009 10:12 AM 5.5 3.5 (ASTM C-173) 72 84 6/6/2009 Wright, DaJuan TXI Plant Number: 131 Delivery Ticket No.: 875237 Mix ID: 8205 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Break Type: Cap Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq.ln. Max Load: PSI: 93 LAB 1 C-1231 6/12/2009 7 12 N/A 6 28.27 111390 3940 94 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 128240 4540 95 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 127880 4520 96 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 Specifications: Results to Date: 28 4000 PASS CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, LTD Respectfully Submitted By: ~..~ ~ of Alpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced andlor distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. .>.. ~ ` ~ . Geotechnical Engineering • Construction Materials Testing " Environmen#al En®ineer+ng " Consulting ;~~ x98039 ALPHA TESTING, INC. C.~C 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 Re Ort (972) 620-8911 p Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-45 ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: PAVING, FROM SE CORNER (2ND HALF) Sample Location: 225'N & 18'W FROM SE CORNER OF SW PARKING LOT Date Placed: 6/5/2009 Plant Number: N/A Time Placed: 11:25 AM Delivery Ticket No.: N/A Slump (ASTM C-143): 5.0 Mix ID: 8205 Air Content: 3.0 (ASTM C-173) Made By: ALPHA Air Temperature: 78 Cured Specification: ASTM.C-31 Specimen Temperature: 90 •~,~ Date Received: 6/6/2009 Field Data Submitted By: Wright, DaJuan Mix Data Submitted By: TXI ` ~: - , CYLINDER COMPRESSION TEST RESULTS `. Lab Cure No.: Type: Break Type: Cap Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq.ln. Max Load: PSI: 97 LAB 1 C-1231 6/12/2009 7 12 N/A 6 28.27 106090 3750 98 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 130150 4600 99 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 136150 ~.. 4820 100 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 4000 i Results to Date: PASS CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, LTD Respectfully Submitted By: ~.~ !~ of Alpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. r Geotechnical En tneerin * Construction Materials 7esUn * Environmental En meerin * Consultin '~ 9804 . _ ~...~ _.~... 9~ 9 9 S~ 9 9 ~: _, ALPHA TESTING, INC. ~ ~~~ 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 Re ort (972) 620-8911 p Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-46 ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 ,~~ Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA -`~ Placement Location: TILT WALL, PANELS 2-9 WEST OF PARKING LOT Sample Location: PANELS 7-8 WEST OF PARKING LOT Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Field Data Submitted By Mix Data Submitted By: 6/5/2009 2:49 PM 5.0 3.25 (ASTM C-173) 80 86 6/6/2009 Wright, DaJuan TXI Plant Number: 141 Delivery Ticket No.: 875614 Mix ID: 0153 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Break Type: Cap Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq.ln. Max Load: PSI: 101 LAB 1 C-1231 6/8/2009 3 12 N/A 6 28.27 110570 3910 102 LAB 1 C-1231 6/12!2009 7 12 N/A 6 28.27 112340 3970 103 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 151120 5350 104 LAB 1 C-1231 7/3/2009 28 12 N/A 6 28.27 146050 x`570 Specifications: Results to Date: 28 5000 PASS CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, LTD Respectfully Submitted By: ~~ !~ of Alpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. G~otechnical Engineering * Construction Materials Testing " Environmental Engineering * Consulting 98041 ALPHA TESTING, INC. ~ < 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 Re Ort (972) 620-8911 p Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-42 ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 " Fax Number: (972) 361-6800 ---~ Project Desc: POINT WEST I EXPANSION ~T10RTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Locatl Sample Location: PAVING, FROM SE CORNER (2ND HALF) TO 330' TOWARDS NORTH 100'N & 20'W FROM SE CORNER OF SW PARKING LOT Date Placed: 6/5/2009 Plant Number: 131 Time Placed: 7:59 AM Delivery Ticket No.: 875069 Slump (ASTM C-143): 6.5 Mix ID: 8205 Air Content: 5.0 (ASTM C-173) Made By: ALPHA Air Temperature: 70 Specimen Temperature: 80 Cured Specification: ASTM C-31 Date Received: 6/6/2009 Field Data Submitted By: Wright, DaJuan Mix Data Submitted By: TXI ~~, i CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq.ln. Max Load: PSI:.. 85 LAB 1 C-1231 6/12/2009 7 12 N/A 6 28.27 91330 ;-3230 86 LAB 1 7/3/2009 28 12 N/A 6 28.27 0 -~ 87 LAB 1 7/3/2009 28 12 N/A 6 28.27 0 88 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 Specifications: Results to Date: 28 ___ 4000 N/A CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavatioryrrtd~otter Concrete, LTD (/~~~ j ~/e F Respectfully Submitted By: ~..~ !~'- of Alpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnicai Engineering 'Construction Materials Testing " Environmental Engineering "Consulting , ; 98037 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 Re Ort (972) 620-8911 p Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-43 ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: PAVING, FROM SE CORNER (2ND HALF) TO 330' TOWARDS NORTH Sample Location: 150'N & 15'W FROM SE CORNER OF SW PARKING LOT Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: 6/5/2009 9:02 AM 6.75 3.25 (ASTM C-173) 72 Specimen Temperature: 80 Date Received: 6/6/2009 Field Data Submitted By: Wright, DaJuan Mix Data Submitted By: TXI Plant Number: 131 Delivery Ticket No.: 875135 Mix ID: 8205 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq.ln. Load: I: 89 LAB 1 C-1231 6/12/2009 7 12 N/A 6 28 27 9963 't 3 2 . 5 0 90 LAB 1 7/3/2009 28 12 N/A 6 28.27 0 91 LAB 1 7/3/2009 28 12 N/A 6 28.27 0 92 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 Specifications: Results to Date: 28 4000 /y/q CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, LTD Respectfully Submitted By: ~..~ !~ of Atpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnical Engineering "Construction Materials Testing " Environmental Engineering `Consulting 98038 ALPHA TESTING, INC. :Y~ 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 Re ort (972) 620-8911 p Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-44 ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY & WEST OF BELT LINE RD. FIELD DATA Placement Location: PAVING, FROM SE CORNER (2ND HALF) TO 330' TOWARDS NORTH Sample Location: 185'N 8 30'W FROM SE CORNER OF SW PARKING LOT Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Field Data Submitted By Mix Data Submitted By: 6/5/2009 10:12 AM 5.5 3.5 (ASTM C-173) 72 84 6/6/2009 Wright, DaJuan TXI Plant Number: 131 Delivery Ticket No.: 875237 Mix ID: 8205 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq.ln. Max Load: PSI: 93 LAB 1 C-1231 6!12/2009 7 12 N/A 6 28.27 111390 3940 94 LAB 1 7/3/2009 28 12 N/A 6 28.27 0 95 LAB 1 7/3/2009 28 12 N/A 6 28.27 0 96 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 -- - - - - - Specifications Results to Date: 28 - -- - - 4000 N/A CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, LTD Respectfully Submitted By: ~.~ !~ of Alpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnicai En$insering' Construction Materials Testing " Environmental Engineerln~'" Consulting ;; ,; 98039 ALPHA TESTING, INC. ~ < ~'~ 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 Re Ort (972) 620-8911 p Tested For: DUKE CONSTRUCTION LIMITED PARTNERSHIP Our Report No.: 090238-45 ATTN: JOHN WARREN 14241 N. DALLAS PARKWAY, SUITE 1000 DALLAS, TX 75254 Fax Number: (972) 361-6800 Project Desc: POINT WEST I EXPANSION NORTH OF LBJ FWY 8~ WEST OF BELT LINE RD. FIELD DATA Placement Location: PAVING, FROM SE CORNER (2ND HALF) Sample Location: 225'N & 18'W FROM SE CORNER OF SW PARKING LOT Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Date Received: Field Data Submitted By Mix Data Submitted By: 6/5/2009 11:25 AM 5.0 3.0 (ASTM C-173) 78 90 6/6/2009 Wright, DaJuan TXI Plant Number: N/A Delivery Ticket No.: N/A Mix ID: 8205 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure No.: Type: Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq.ln. Max Load: PSI: 97 LAB 1 C-1231 6/12/2009 7 12 N/A 6 28.27 106090 3750 98 LAB 1 7/3/2009 28 12 N/A 6 28.27 0 99 LAB 1 7/3/2009 28 12 N/A 6 28.27 0 100 LAB 1 HOLD HOLD 12 N/A 6 28.27 0 Specifications: Results to Date: 28 4000 N/A CC: Duke Construction Limited Partnership, City of Coppell, Pacheco Koch Consulting Engineers, Tri Dal Excavation Ltd., Potter Concrete, LTD Respectfully Submitted By: ~..~ ~ of Alpha Testing, Inc Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced andlor distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnical Engineering * Construction Materials Testing " Environmental Engineering * Consulting 98040