Security Fire Systems-LR170602
2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 TEL [214] 350 5600 FAX [214] 350 0019
REPORT OF FIELD DENSITY TESTS
Security Fire Systems
196 S. Freeport Parkway
Coppell, Texas
REPORTED TO: Security Fire Systems, Inc.
196 Freeport Parkway
Coppell, Texas 75019
ATTN: Mr. Mike Alexander
REPORT NO. 15
REPORT DATE: 06-02-17
REG PROJECT NO. 21753
TECHNICIAN: J. Castaneda
PAGE: 1 of 2
CONTRACTOR: Trest Construction
Proctor
No.
ASTM
Standard
Description
Optimum
Moisture, %
Maximum
Density, PCF
1 D-698 Reddish brown clayey sand w/sandstone 12.2 109.9
2 D-698 Light brown sandy clay 13.5 110.5
3 D-698 Dark brown clayey sand 10.5 117.1
4 D-698 Reddish brown sandy clay 13.5 110.7
5 D-698 Red & light brown clayey sand 11.6 114.0
Test
No.
Date
Location
Depth
Below
Final S. G.
(feet)
Pocket
Pen
(tsf)
Field
Density
(pcf)
Field
Moisture
(%)
Proctor
ID
Compaction
Level (%)
132 05-23-17 Water Line A: STA 0+00 5.0 3.0 104.9 15.7 1 95.5
133 Water Line A: STA 0+01 4.0 3.5 105.7 13.8 1 96.2
134 Water Line A: STA 0+02 3.0 3.75 104.6 16.0 1 95.2
135 Water Line A: STA 0+03 2.0 3.5 106.1 13.0 1 96.5
136 Water Line A: STA 0+04 1.0 3.0 104.8 15.8 1 95.4
137 Water Line A: STA 0+05 0.0 3.75 105.8 13.5 1 96.3
138 05-24-17 Water Line A: STA 7+48 5.0 3.5 106.1 15.8 2 96.0
139 Water Line A: STA 7+49 4.0 3.5 106.4 16.2 2 96.3
140 Water Line A: STA 7+50 3.0 3.5 108.2 15.0 2 97.9
141 Water Line A: STA 7+51 2.0 3.5 106.3 16.0 2 96.2
142 Water Line A: STA 7+52 1.0 3.75 107.2 15.8 2 97.0
143 Water Line A: STA 7+53 0.0 3.5 106.1 15.6 2 96.0
144 Water Line A: STA 8+60 10.0 3.75 107.7 14.9 2 97.5
145 Water Line A: STA 8+59 9.0 3.75 107.8 15.1 2 97.6
146 Water Line A: STA 8+58 8.0 4.0 108.3 14.2 2 98.0
147 Water Line A: STA 8+57 7.0 3.75 107.5 15.0 2 97.3
148 Water Line A: STA 8+56 6.0 3.75 106.9 14.9 2 96.7
149 Water Line A: STA 8+55 5.0 4.0 108.7 14.8 2 98.4
Comments: Where tested, materials were in compliance with project specifications.
REPORT NO. 15
REPORT DATE: 06-02-17
REG PROJECT NO. 21753
PAGE: 2 of 2
E-Mail
Distribution: (1) Security Fire Systems, Inc./
Mr. Mike Alexander
(1) GPF Architects, LLC/Mr. Greg Frnka
(1) Trest Construction/Mr. Gilbert Trevino
(1) City of Coppell/Mr. Matthew Mabry
(1) Trest Construction/Mr. Clement Wang
(1) Trest Construction/Mr. Eric Larsen
Submitted by:
REED ENGINEERING GROUP, LTD.
Registration Number F-3114
Bill Woolwine
Sr. Manager, CMT
BW/jm