Preliminary Engineering Plan_v1 (Markups)LAKESIDE VILLAGE PHASE II
VOLUME 96147, PAGE 0011
M.R.D.C.T.
LOT 2R
7.01 ACRES
305,300 SQ. FT.DDD15' PUBLIC ALLEY
PER VOLUME
92228, PAGE 3876
M.R.D.C.T.
WATERS EDGE
PHASE ONE
VOLUME 92228,
PAGE 3876
M.R.D.C.T.
LOT 11, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 8, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 10, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 14, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 12, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 7, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 9, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 13, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.15' UTILITY, LANDSCAPE & SIDEWALK EASEMENTPER VOLUME 94144, PAGE 2344M.R.D.C.T.MAC ARTHUR BOULEVARD
VARIABLE WIDTH RIGHT-OF-WAY
SDMH-RIM=460.2'
FL-18"RCP=456.3' (NE)
SDMH-RIM=454.8'
FL-24"RCP=447.15' (E)
FL-24"RCP=447.15' (S)
FL-18"RCP=449.2' (W)
SDMH-RIM=454.8'
PIT = 451.8
SDMH-RIM=454.6'
FL-24"RCP=451.4' (N)
SDMH-RIM=454.2'
FL-18"RCP=450.9' (NE)
30' FIRELANE EASMENT
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.25' FIRELANE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.20' DRAINAGE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.M.R.D.C.T.PER VOLUME 96147, PAGE 001130' BUILDING LINEVISIBILITY
TRIANGLE
PER VOLUME
96147, PAGE 0011
M.R.D.C.T.
15' UTILITY, LANDSCAPE &
SIDEWALK EASEMENT
VOLUME 85095, PAGE 2840 &
VOLUME 85186, PAGE 1670
M.R.D.C.T.
M.R.D.C.T.
PER VOLUME 85186, PAGE 1670
30' BUILDING LINE
VISIBILITY TRAINGLE
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.
VISIBILITY TRAINGLE
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.
WALL MAINTENANCE EASEMENT
VOLUME 85186, PAGE 1670
M.R.D.C.T.
30' FIRELANE
EASMENT
PER VOLUME
96147, PAGE 0011
M.R.D.C.T.
25' FIRELANE EASMENT
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.
SDMH-RIM=454.9'
FL-18"RCP=450.4' (S)SANDY LAKE ROADVARIABLE WIDTH RIGHT-OF-WAYGRATE-RIM=456.3'
GRATE-RIM=457.5'
RIGHT TURN EASMENT
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.
5' LONE STAR GAS EASMENT
VOLUME 96147, PAGE 0011
M.R.D.C.T.
VISIBILITY TRAINGLE
VOLUME 96147, PAGE 0011
M.R.D.C.T.
5' RIGHT-OF-WAY
DEDICATION
VOLUME 96147, PAGE
0011
M.R.D.C.T.
15' UTILITY, LANDSCAPE &
SIDEWALK EASEMENT
VOLUME 96147, PAGE 0011
M.R.D.C.T.N86°11'41"E485.00'N
3
9
°
2
1
'
5
8
"
E
8
2
.
2
5
'
N2°35'17"W 27.00'
N20°48'
1
5
"
W
217.85'
N0°26'51"W 310.63'S89°33'09"W455.85'S43°28'56"W
27.75'S2°35'17"E 75.00'
∆∆
S2°35'17"E 341.00'S3°50'34"E 97.61'
VAN
PROP. 1" WATER SERVICE
CONNECT TO EX. 8" WATER
45° BEND
END PROP. 1" WATER SERVICE
REFER TO MEP PLANS FOR
CONTINUATION
107 LF 1" WATERSTA: 1+26.84 SEWER A
INSTALL:
1 - 45° BEND
FL 6" E: 453.36
FL 6" NW: 453.36
STA: 0+00.00 SEWER A
INSTALL:
1 - 4' MANHOLE PER CITY DETAILS
EX FL = 447.6±
FL 6" W: 447.80
STA: 1+32.31 SEWER A
END OF PROP. 6" SEWER
REFER TO MEP PLANS
FOR CONTINUATION
FL 6" SE: 453.60
PROP. 1" WATER METER
LEGEND
EXISTING FIRE HYDRANT ASSEMBLY
PROPOSED FIRE HYDRANT ASSEMBLY
EXISTING WATER MAIN
PROPOSED WATER LINE AND GATE VALVE
EXISTING SANITARY SEWER AND MANHOLE
PROPOSED SANITARY SEWER LINE
PROPOSED GAS LINE
PROPOSED COMMUNICATIONS LINE
PROPOSED UNDERGROUND ELECTRIC LINE
PRELIMINARY UTILITYPLANC-1
S
NOTES:
1.CONTRACTOR SHALL COORDINATE WITH FRANCHISE UTILITY
COMPANIES AND IRRIGATION PLANS TO DETERMINE QUANTITY, SIZE,
AND LOCATION FOR ALL CONDUIT AND SLEEVING REQUIRED TO SERVE
BUILDING AND SITE. ALL CONDUIT AND SLEEVES SHALL BE INSTALLED
PRIOR TO SUBGRADE PREPARATION AND PAVING.
FRANCHISE UTILITY NOTES:
1.THE GAS, ELECTRIC AND TELEPHONE INFORMATION SHOWN ON THIS
PLAN IS BASED UPON THE LATEST INFORMATION AVAILABLE FROM THE
RESPECTIVE FRANCHISE UTILITY COMPANIES. IT IS INTENDED FOR
PURPOSES OF GENERAL BIDDING AND BASIC CLARITY. SPECIFIC JOB
SITE CONDITIONS SHALL BE FIELD VERIFIED PER NOTES 2 THROUGH 4
BELOW. THE FRANCHISE UTILITY CONTRACTOR ASSUMES ALL
RESPONSIBILITY FOR SAID FIELD CONDITIONS AND ASSOCIATED
REVISIONS REQUIRED BY THE RESPECTIVE UTILITY COMPANIES
INVOLVED.
2.THE FRANCHISE UTILITY CONTRACTOR SHALL CONTACT THE
RESPECTIVE FRANCHISE UTILITY COMPANIES, VERIFY ALL
REQUIREMENTS AND EQUIPMENT, AND FURNISH AND INSTALL,
INCLUDING BUT NOT LIMITED TO, ALL METERS, TRANSFORMERS,
CONDUIT, CONCRETE PADS, TRENCHING, AND BACKFILL NECESSARY
FOR PROPER INSTALLATION. FRANCHISE UTILITY CONTRACTOR SHALL
ALSO PAY ALL FEES AND CHARGES INCURRED AND COORDINATE WITH
OTHER FRANCHISE UTILITY COMPANIES.
3.THE FRANCHISE UTILITY CONTRACTOR SHALL FIELD VERIFY, IN THE
PRESENCE OF THE RESPECTIVE UTILITY COMPANY
REPRESENTATIVES, THE LOCATION OF ALL EXISTING AND PROPOSED
UTILITY SERVICES AND EQUIPMENT. THE FRANCHISE UTILITY
CONTRACTOR SHALL INCLUDE IN HIS BID SUFFICIENT FUNDS TO
COVER ALL COSTS REQUIRED BY UTILITY COMPANIES TO PROVIDE
NEW SERVICES AND/OR UPGRADE EXISTING SERVICES. NO
ALLOWANCES WILL BE MADE FOR FRANCHISE UTILITY CONTRACTOR'S
UNFAMILIARITY WITH THE EXISTING CONDITION, REQUIREMENTS OF
THE NEW CONDITIONS, AND/OR FAILURE TO COORDINATE
INSTALLATION.
4.CONTRACTOR SHALL VERITY THAT METER AND TRANSFORMER
LOCATIONS SHOWN MEET DESIGN CRITERIA BY FRANCHISE UTILITY
COMPANIES FOR, BUT NOT LIMITED TO, THE OFFSET DISTANCE FROM
FACE OF BUILDING.
0
GRAPHIC SCALE
1 inch = ft.
40 40 80
40
20
DATENo.REVISIONBYDATE:
SHEET
File No. 2022-194
7/17/23
CHECKED:CLC
DRAWN:CLC
DESIGN:CLCKROGER 448950 E. SANDY LAKERD.COPPELL, TXTEXAS REGISTRATION #14199
1903 CENTRAL DR. SUITE #406PHONE: 817.281.0572BEDFORD, TX 76021 WWW.CLAYMOOREENG.COMPRELIMINARY
CLAYMOORE ENGINEERING
CLAY CRISTY
109800 7/17/2023