Preliminary Engineering Plan_v1 (Markups)LAKESIDE VILLAGE PHASE II VOLUME 96147, PAGE 0011 M.R.D.C.T. LOT 2R 7.01 ACRES 305,300 SQ. FT.DDD15' PUBLIC ALLEY PER VOLUME 92228, PAGE 3876 M.R.D.C.T. WATERS EDGE PHASE ONE VOLUME 92228, PAGE 3876 M.R.D.C.T. LOT 11, BLOCK D WATERS EDGE, PHASE TWO VOLUME 94144, PAGE 02344 M.R.D.C.T. LOT 8, BLOCK D WATERS EDGE, PHASE TWO VOLUME 94144, PAGE 02344 M.R.D.C.T. LOT 10, BLOCK D WATERS EDGE, PHASE TWO VOLUME 94144, PAGE 02344 M.R.D.C.T. LOT 14, BLOCK D WATERS EDGE, PHASE TWO VOLUME 94144, PAGE 02344 M.R.D.C.T. LOT 12, BLOCK D WATERS EDGE, PHASE TWO VOLUME 94144, PAGE 02344 M.R.D.C.T. LOT 7, BLOCK D WATERS EDGE, PHASE TWO VOLUME 94144, PAGE 02344 M.R.D.C.T. LOT 9, BLOCK D WATERS EDGE, PHASE TWO VOLUME 94144, PAGE 02344 M.R.D.C.T. LOT 13, BLOCK D WATERS EDGE, PHASE TWO VOLUME 94144, PAGE 02344 M.R.D.C.T.15' UTILITY, LANDSCAPE & SIDEWALK EASEMENTPER VOLUME 94144, PAGE 2344M.R.D.C.T.MAC ARTHUR BOULEVARD VARIABLE WIDTH RIGHT-OF-WAY SDMH-RIM=460.2' FL-18"RCP=456.3' (NE) SDMH-RIM=454.8' FL-24"RCP=447.15' (E) FL-24"RCP=447.15' (S) FL-18"RCP=449.2' (W) SDMH-RIM=454.8' PIT = 451.8 SDMH-RIM=454.6' FL-24"RCP=451.4' (N) SDMH-RIM=454.2' FL-18"RCP=450.9' (NE) 30' FIRELANE EASMENT PER VOLUME 96147, PAGE 0011 M.R.D.C.T.25' FIRELANE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.20' DRAINAGE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.M.R.D.C.T.PER VOLUME 96147, PAGE 001130' BUILDING LINEVISIBILITY TRIANGLE PER VOLUME 96147, PAGE 0011 M.R.D.C.T. 15' UTILITY, LANDSCAPE & SIDEWALK EASEMENT VOLUME 85095, PAGE 2840 & VOLUME 85186, PAGE 1670 M.R.D.C.T. M.R.D.C.T. PER VOLUME 85186, PAGE 1670 30' BUILDING LINE VISIBILITY TRAINGLE PER VOLUME 96147, PAGE 0011 M.R.D.C.T. VISIBILITY TRAINGLE PER VOLUME 96147, PAGE 0011 M.R.D.C.T. WALL MAINTENANCE EASEMENT VOLUME 85186, PAGE 1670 M.R.D.C.T. 30' FIRELANE EASMENT PER VOLUME 96147, PAGE 0011 M.R.D.C.T. 25' FIRELANE EASMENT PER VOLUME 96147, PAGE 0011 M.R.D.C.T. SDMH-RIM=454.9' FL-18"RCP=450.4' (S)SANDY LAKE ROADVARIABLE WIDTH RIGHT-OF-WAYGRATE-RIM=456.3' GRATE-RIM=457.5' RIGHT TURN EASMENT PER VOLUME 96147, PAGE 0011 M.R.D.C.T. 5' LONE STAR GAS EASMENT VOLUME 96147, PAGE 0011 M.R.D.C.T. VISIBILITY TRAINGLE VOLUME 96147, PAGE 0011 M.R.D.C.T. 5' RIGHT-OF-WAY DEDICATION VOLUME 96147, PAGE 0011 M.R.D.C.T. 15' UTILITY, LANDSCAPE & SIDEWALK EASEMENT VOLUME 96147, PAGE 0011 M.R.D.C.T.N86°11'41"E485.00'N 3 9 ° 2 1 ' 5 8 " E 8 2 . 2 5 ' N2°35'17"W 27.00' N20°48' 1 5 " W 217.85' N0°26'51"W 310.63'S89°33'09"W455.85'S43°28'56"W 27.75'S2°35'17"E 75.00' ∆∆ S2°35'17"E 341.00'S3°50'34"E 97.61' VAN PROP. 1" WATER SERVICE CONNECT TO EX. 8" WATER 45° BEND END PROP. 1" WATER SERVICE REFER TO MEP PLANS FOR CONTINUATION 107 LF 1" WATERSTA: 1+26.84 SEWER A INSTALL: 1 - 45° BEND FL 6" E: 453.36 FL 6" NW: 453.36 STA: 0+00.00 SEWER A INSTALL: 1 - 4' MANHOLE PER CITY DETAILS EX FL = 447.6± FL 6" W: 447.80 STA: 1+32.31 SEWER A END OF PROP. 6" SEWER REFER TO MEP PLANS FOR CONTINUATION FL 6" SE: 453.60 PROP. 1" WATER METER LEGEND EXISTING FIRE HYDRANT ASSEMBLY PROPOSED FIRE HYDRANT ASSEMBLY EXISTING WATER MAIN PROPOSED WATER LINE AND GATE VALVE EXISTING SANITARY SEWER AND MANHOLE PROPOSED SANITARY SEWER LINE PROPOSED GAS LINE PROPOSED COMMUNICATIONS LINE PROPOSED UNDERGROUND ELECTRIC LINE PRELIMINARY UTILITYPLANC-1 S NOTES: 1.CONTRACTOR SHALL COORDINATE WITH FRANCHISE UTILITY COMPANIES AND IRRIGATION PLANS TO DETERMINE QUANTITY, SIZE, AND LOCATION FOR ALL CONDUIT AND SLEEVING REQUIRED TO SERVE BUILDING AND SITE. ALL CONDUIT AND SLEEVES SHALL BE INSTALLED PRIOR TO SUBGRADE PREPARATION AND PAVING. FRANCHISE UTILITY NOTES: 1.THE GAS, ELECTRIC AND TELEPHONE INFORMATION SHOWN ON THIS PLAN IS BASED UPON THE LATEST INFORMATION AVAILABLE FROM THE RESPECTIVE FRANCHISE UTILITY COMPANIES. IT IS INTENDED FOR PURPOSES OF GENERAL BIDDING AND BASIC CLARITY. SPECIFIC JOB SITE CONDITIONS SHALL BE FIELD VERIFIED PER NOTES 2 THROUGH 4 BELOW. THE FRANCHISE UTILITY CONTRACTOR ASSUMES ALL RESPONSIBILITY FOR SAID FIELD CONDITIONS AND ASSOCIATED REVISIONS REQUIRED BY THE RESPECTIVE UTILITY COMPANIES INVOLVED. 2.THE FRANCHISE UTILITY CONTRACTOR SHALL CONTACT THE RESPECTIVE FRANCHISE UTILITY COMPANIES, VERIFY ALL REQUIREMENTS AND EQUIPMENT, AND FURNISH AND INSTALL, INCLUDING BUT NOT LIMITED TO, ALL METERS, TRANSFORMERS, CONDUIT, CONCRETE PADS, TRENCHING, AND BACKFILL NECESSARY FOR PROPER INSTALLATION. FRANCHISE UTILITY CONTRACTOR SHALL ALSO PAY ALL FEES AND CHARGES INCURRED AND COORDINATE WITH OTHER FRANCHISE UTILITY COMPANIES. 3.THE FRANCHISE UTILITY CONTRACTOR SHALL FIELD VERIFY, IN THE PRESENCE OF THE RESPECTIVE UTILITY COMPANY REPRESENTATIVES, THE LOCATION OF ALL EXISTING AND PROPOSED UTILITY SERVICES AND EQUIPMENT. THE FRANCHISE UTILITY CONTRACTOR SHALL INCLUDE IN HIS BID SUFFICIENT FUNDS TO COVER ALL COSTS REQUIRED BY UTILITY COMPANIES TO PROVIDE NEW SERVICES AND/OR UPGRADE EXISTING SERVICES. NO ALLOWANCES WILL BE MADE FOR FRANCHISE UTILITY CONTRACTOR'S UNFAMILIARITY WITH THE EXISTING CONDITION, REQUIREMENTS OF THE NEW CONDITIONS, AND/OR FAILURE TO COORDINATE INSTALLATION. 4.CONTRACTOR SHALL VERITY THAT METER AND TRANSFORMER LOCATIONS SHOWN MEET DESIGN CRITERIA BY FRANCHISE UTILITY COMPANIES FOR, BUT NOT LIMITED TO, THE OFFSET DISTANCE FROM FACE OF BUILDING. 0 GRAPHIC SCALE 1 inch = ft. 40 40 80 40 20 DATENo.REVISIONBYDATE: SHEET File No. 2022-194 7/17/23 CHECKED:CLC DRAWN:CLC DESIGN:CLCKROGER 448950 E. SANDY LAKERD.COPPELL, TXTEXAS REGISTRATION #14199 1903 CENTRAL DR. SUITE #406PHONE: 817.281.0572BEDFORD, TX 76021 WWW.CLAYMOOREENG.COMPRELIMINARY CLAYMOORE ENGINEERING CLAY CRISTY 109800 7/17/2023