Exhibit B - Site PlanVAN
PROP. KIOSKFFE = 458.08NO
PARKI
N
GNOPARKING ZONING:RESIDENTIAL
R136.8'
EX, SIDEWALK
EX, SIDEWALK
TRANSFORMER
AIR/WATER STATION
UNDERGROUND TANKS
ADA PARKING
PROP. KIOSK
(179 SF.)
HEIGHT: 11'
ZONING: COMMERCIAL
SITE AREA: 7.01 AC (305,300 SF)
EX. BLDG. AREA: 62,789 SF
LOT 2R
LAKESIDE VILLAGE
PHASE II
HEIGHT: 30'-7"
PROP.
LANDSCAPE
ISLAND
EX. ADA PKNG.
EX. ADA
PKNG.
EX. ADA
PKNG.
ZONING:RESIDENTIAL
ZONING:RESIDENTIAL ZONING:RESIDENTIAL
ZONING:RESIDENTIAL
ZONING:RESIDENTIAL
ZONING:RESIDENTIAL
ZONING:RESIDENTIAL
ZONING:RESIDENTIAL
5'R79.52'±R30.72'R2
7
.
6
2
'
5 DOUBLE
SIDED
PUMPS
R
7
.
7
2
'
±LOADING AREAEX, SIDEWALK
EX, SIDEWALK
EX, FH.
EX, FH.
EX, FH.R8.12'±DDD15' PUBLIC ALLEY
PER VOLUME
92228, PAGE 3876
M.R.D.C.T.
WATERS EDGE
PHASE ONE
VOLUME 92228,
PAGE 3876
M.R.D.C.T.
LOT 11, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 8, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 10, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 14, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 12, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 7, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 9, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.
LOT 13, BLOCK D
WATERS EDGE, PHASE TWO
VOLUME 94144, PAGE 02344
M.R.D.C.T.15' UTILITY, LANDSCAPE & SIDEWALK EASEMENTPER VOLUME 94144, PAGE 2344M.R.D.C.T.MAC ARTHUR BOULEVARD
VARIABLE WIDTH RIGHT-OF-WAY
30' FIRELANE EASMENT
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.25' FIRELANE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.20' DRAINAGE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.M.R.D.C.T.PER VOLUME 96147, PAGE 001130' BUILDING LINEVISIBILITY
TRIANGLE
PER VOLUME
96147, PAGE 0011
M.R.D.C.T.
15' UTILITY, LANDSCAPE &
SIDEWALK EASEMENT
VOLUME 85095, PAGE 2840 &
VOLUME 85186, PAGE 1670
M.R.D.C.T.
M.R.D.C.T.
PER VOLUME 85186, PAGE 1670
30' BUILDING LINE
VISIBILITY TRAINGLE
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.
VISIBILITY TRAINGLE
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.
WALL MAINTENANCE EASEMENT
VOLUME 85186, PAGE 1670
M.R.D.C.T.
30' FIRELANE
EASMENT
PER VOLUME
96147, PAGE 0011
M.R.D.C.T.
25' FIRELANE EASMENT
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.SANDY LAKE ROADVARIABLE WIDTH RIGHT-OF-WAYRIGHT TURN EASMENT
PER VOLUME 96147, PAGE 0011
M.R.D.C.T.
5' LONE STAR GAS EASMENT
VOLUME 96147, PAGE 0011
M.R.D.C.T.
VISIBILITY TRAINGLE
VOLUME 96147, PAGE 0011
M.R.D.C.T.
5' RIGHT-OF-WAY
DEDICATION
VOLUME 96147, PAGE
0011
M.R.D.C.T.
15' UTILITY, LANDSCAPE &
SIDEWALK EASEMENT
VOLUME 96147, PAGE 0011
M.R.D.C.T.N86°11'41"E485.00'N
3
9
°
2
1
'
5
8
"
E
8
2
.
2
5
'
N2°35'17"W 27.00'
N20°48'
1
5
"
W
217.85'
N0°26'51"W 310.63'S89°33'09"W455.85'S43°28'56"W
27.75'S2°35'17"E 75.00'
∆∆
S2°35'17"E 341.00'S3°50'34"E 97.61'EX. TRANSFORMEREX. DUMPSTERW/MASONRY WALLPROP
CANOPY
2,880 SF.
19'-2" HT.
EX, FH.
EX, FH.
EX. MONUMENT SIGN
PREVIOUSLY APPROVED
AT 7'6"X9'2"
EX. LIGHT POLE
EX. LIGHT POLE
EX.
LIGHT
POLE
EX. LIGHT POLE
EX. LIGHT POLE
EX. LIGHT POLE
EX. LIGHT POLE
EX. LIGHT POLE EX. LIGHT POLE
EX. LIGHT POLE
EX. LIGHT POLE
EX. LIGHT POLE
EX. LIGHT POLE
EX. TRANSFORMER
EX, SIDEWALK
EX, SIDEWALK
EX, SIDEWALK
EX. MASONRY WALL
W / SIGN
EX. LIGHT POLE
EX. LIGHT POLE
EX. MONUMENT SIGN
PROP. 7'2"X4'
MONUMENT SIGNR30'R30'R30'R20'R30'R10'R30'
R10'
PROP. PROPANE
TANKS STORAGE18.2'±17.9'±18'±23.6'±17.8'±18.1'±23.1'±17.7'±17.5'±23.2'±17.8'±18.4'±28.6'±17.9'±18.3'±17.6'±18'±20.6'±9.8'±
9.4'±17.4'±29'17.6'±35.47'±232.32'
40.91'
37'195.85'28.08'213.67'36.46'467.19'± TO FOUNTAIN VIEW PI68.65'60.61'83.3'345.4'± TO MEDIAN
9.4'±
10'±
10'±
9.5'±
9'±
9.5'±
9.9'±9.7'±9.9'±9.8'±19.74'23.1'18.1'17.6'23.3'17.5'9.34'
±
9.41'
±
66.14'82.04'86.06'417.58'43.33'38.66'17.84'±10.06'±9.36'
±
5'17.56'17.8'41.55'±17.81'±N
COUNTY SURVEY:ABSTRACT NO.
DALLAS B.B.B. & C.R.R.199
CITY:STATE:
DALLAS TX.
LEGAL DESCRIPTION:
OWNER:
APPLICANT:
CLAYMOORE ENGINEERING, INC.
1903 CENTRAL DR. STE. 406
BEDFORD, TX 76021
PH: 817.281.0572
SURVEYOR:
EAGLE SURVEYING, LLC
210 S. ELM ST. SUITE #104
DENTON, TX 76201
PH: 940.222.3009
KROGER TX LP
7TH FLOOR ATTN PROPERTY
CINCINATTI, OHIO 45202
CONTACT NAME: CLAY CRISTI
CONTACT NAME: TYLER RANK
LOT 2R, OF LAKESIDE VILLAGE PHASE II,
AN ADDITION TO CITY OF COPPELL
VICINITY MAP
N.T.S.
CONTACT NAME:_____________
ZONING DESCRIPTION:
C - COMMERCIAL
0
GRAPHIC SCALE
1 inch = ft.
40 40 80
40
20
SUP SITE PLANSUP
SITE
DATENo.REVISIONBYDATE:
SHEET
File No. 2022-194
10/16/23
CHECKED:CLC
DRAWN:CLC
DESIGN:CLCKROGER 448950 E. SANDY LAKERD.COPPELL, TXTEXAS REGISTRATION #14199
1903 CENTRAL DR. SUITE #406PHONE: 817.281.0572BEDFORD, TX 76021 WWW.CLAYMOOREENG.COMPRELIMINARY
CLAYMOORE ENGINEERING
CLAY CRISTY
109800 10/16/2023
LEGEND
CONCRETE PAVEMENT
SIDEWALK CONCRETE PAVEMENT
LANDSCAPE AREAS
EXISTING TREES
PROPOSED CONCRETE CURB AND GUTTER
PARKING COUNT
FULL-DEPTH SAWCUT
PROPOSED FIRE LANE STRIPPING
NOTES:
1.ALL DIMENSIONS ARE TO FACE OF CURB
UNLESS OTHERWISE NOTED.
2.ALL ADDITIONAL SITE LIGHTING WILL BE IN
ACCORDANCE WITH CITY STANDARDS.
3.FUEL VENTS WILL BE LOCATED ON CANOPY
STRUCTURE.
ACCORDING TO MAP NO. 48113C0155K, DATED 07/17/2014 OF THE NATIONAL
FLOOD INSURANCE PROGRAM MAP, FLOOD INSURANCE RATE MAP OF DALLAS
COUNTY, TEXAS, FEDERAL EMERGENCY MANAGEMENT AGENCY, FEDERAL
INSURANCE ADMINISTRATION, THIS PROPERTY IS WITHIN NON-SHADED ZONE X,
(AREAS DETERMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE
FLOODPLAIN). IF THIS SITE IS NOT WITHIN AN IDENTIFIED SPECIAL FLOOD
HAZARD AREA, THIS FLOOD STATEMENT DOES NOT IMPLY THAT THE
PROPERTY AND/OR THE STRUCTURES THEREON WILL BE FREE FROM
FLOODING OR FLOOD DAMAGE. ON RARE OCCASIONS, GREATER FLOODS CAN
AND WILL OCCUR AND FLOOD HEIGHTS MAY BE INCREASED BY MAN-MADE OR
NATURAL CAUSES. THIS FLOOD STATEMENT SHALL NOT CREATE LIABILITY ON
THE PART OF THE SURVEYOR.
FLOODPLAIN NOTE
C-S-1098R CONDITIONS (DATED JANUARY 9, 1996)
1.THE PROPERTY SHALL BE DEVELOPER AND USED ONLY IN
ACCORDANCE WITH THE SITE PLAN, LANDSCAPE PLAN, MOMUMENT
SIGN PLAN, AND ELEVATION PLANS.
2.THE APPLICANT SHALL CONFER WITH CITY STAFF TO DETERMINE THE
APPROPRIATE NUMBER AND TYPE OF TREES NEEDED TO BUFFER
NOISE AND LIGHT ON THE NORTH AND WEST SIDES OF THE
PROPOSED BUILDING.
3.THE TRASH COMPACTOR AREA SHALL BE SCREENED WITH
APPROPRIATE PLANTS IN ACCORDANCE WITH THE LANDSCAPE PLAN.
4.THE PROPERTY SHALL BE DEVELOPED, USED, AND ANY BUSINESS
OPERATIONS ON THE PROPERTY SHALL LIMIT DELIVERY HOURS TO
NO EARLIER THAN 6 AM AND NO LATER THAN 10 PM DAILY.
C-2-1098R2 CONDITIONS (DATED MAY 11TH, 2004)
5.LIGHTING ASSOCIATED WITH THE PHARMACY DRIVE THRU WILL BE
TIMED TO COINCIDE WITH THE DRIVE-THRU PHARMACY HOURS.
MORE SPECIFICALLY, LIGHTING UNDER CANOPY WILL BE TURNED
OFF AT CLOSING TIME OF THE PHARMACY. REFER TO CANOPY
DETAILS FOR ADDITIONAL INFORMATION ON RECESSED CAN LIGHT
FIXTURE.
6.PHARMACY SPEAKER ON WALL WILL HAVE FULL VOLUME
ADJUSTMENT CAPABILITY WHICH WILL MEET CITY SPECIFICATIONS.
7.THE HOURS OF OPERATION FOR THIS PHARMACY DRIVE THRU SHALL
NOT EXCEED:
9 a.m. to 9 p.m. - MONDAY through FRIDAY,
9 a.m. to 7 p.m. - SATURDAY, and
10 a.m. to 4 p.m. 6 P.M. - SUNDAY.
8.CANOPY WILL HAVE AN EXTERIOR INSULATING FINISHING SYSTEM
(EIFS) AND WILL BE COLOR #6050 WHITE LINEN FROM S.T.O.
CORPORATION.
9.THE EXISTING EXTERNAL LIGHTS ON THE NORTH AND WEST SIDE OF
THE BUILDING ARE NEVER ON. THIS TIMING WILL NOT BE MODIFIED.
10.SIGNAGE WILL BE PROVIDED TO DISCOURAGE CIRCULATION AROUND
THE REAR OF THE BUILDING.
PD-308-C / PD-308R-C CONDITIONS (DATED JULY 11, 2023 /
OCTOBER 10, 2023)
A)THAT EXCEPT AS AMENDED HEREIN, THE PROPERTY AND PD 308R-C
SHALL BE DEVELOPED IN ACCORDANCE WITH ORDINANCE
91500-A-794, ORDINANCE 91500-A- 373 AND ORDINANCE 91500-A-109
WITH THE PREVIOUS DEVELOPMENT REGULATIONS, WHICH ARE
HEREBY INCORPORATED HEREIN AS SET FORTH IN FULL AND HEREBY
REPUBLISHED.
B)THE HOURS OF OPERATION FOR THE DRIVE THROUGH PHARMACY
WINDOW SHALL BE BETWEEN:
9 A.M. TO 9 P.M. - MONDAY THROUGH FRIDAY,
9 A.M. TO 7 P.M. -SATURDAY, AND
10 A.M. TO 6 P.M. ON SUNDAY.
C)THE EXTERIOR LIGHTS ON THE NORTH AND WEST PERIMETER OF THE
PROPERTY MAY BE ILLUMINATED AND MAINTAINED IN ACCORDANCE
WITH THE GLARE AND LIGHTING STANDARDS OF THE ZONING
ORDINANCE, AS AMENDED.
D)IN ADDITION TO THE ORIGINAL REGULATIONS, AS AMENDED, NO
OUTSIDE STORAGE OF MATERIALS OR GOODS WILL BE PERMITTED
UNDER THE FUEL STATION CANOPY OR FUEL STATION SITE.
E)AN ADDITIONAL 40 SQUARE-FOOT MONUMENT SIGN FOR FUEL
PRICING SHALL BE CONSTRUCTED AND MAINTAINED AS SHOWN ON
THE SITE PLAN AND SIGNAGE PLANS, EXHIBIT BAND EXHIBIT F,
RESPECTIVELY.
F)THE ENTIRE SITE, GROCERY STORE AND FUEL STATION, SHALL HAVE
300 PARKING SPACES, INCLUSIVE OF AMERICANS WITH DISABILITIES
REGULATIONS AS PROVIDED IN SITE PLAN, EXHIBIT B.
G)THE HOURS OF OPERATION OF THE FUEL BAYS SHALL BE BETWEEN 6
A.M. TO 12 A.M. DAILY.
H)EXTERIOR CANOPY LIGHTING SHALL EMIT OR BE ILLUMINATED AT NO
GREATER THAN 50.5 FC DURING THE FUEL BAY OPERATIONAL HOURS
AND BE DIMMED TO SURROUNDING LIGHT LEVELS BETWEEN 12 A.M.
AND 6 A.M., IN THE PHOTOMETRIC PLAN AS PROVIDED IN EXHIBIT G.
I)THE PROPOSED TREES AS PROVIDED IN THE LANDSCAPE PLAN SHALL
BE PLANTED AND KEPT IN A HEALTHY GROWING STATE TO MITIGATE
ANY APERTURE IN SCREENING, REGARDLESS OF THE CURRENT
STATE OF THE TREE CONFIGURATION; AND LANDSCAPE SHALL BE
REPLACED WHERE THERE IS ANY UNHEALTHY AND DEAD
VEGETATION.
J)THE DEVELOPED SITE AND SITE LIGHTING ELEMENTS SHALL BE
MAINTAINED TO REDUCE LIGHT EMISSIONS TOWARD THE WEST AND
NORTH OF THE RESIDENTIAL AREAS WHICH MAY BE
ADMINISTRATIVELY APPROVED BY THE DIRECTOR OF PLANNING.
K)THE PRIMARY FUEL DELIVERY TRUCK ROUTE SHALL BE AS DEPICTED
ON THE SITE PLAN, EXHIBIT B, BETWEEN THE HOURS OF 6 A.M. TO 10
P.M. CIRCUMSCRIBING THE PRIMARY BUILDING WITH ENTRANCE AND
EXIT FROM SANDY LAKE.
L)AN ALTERNATIVE FUEL DELIVERY TRUCK ROUTE BE ALLOWED TO
ENTER FROM SANDY LAKE AND EXIT SOUTHBOUND TO S MACARTHUR
FROM 8 P.M. UNTIL 10 P.M.