Exhibit C - Landscape PlanLAKESIDE VILLAGE PHASE IIVOLUME 96147, PAGE 0011M.R.D.C.T.LOT 2R7.01 ACRES305,300 SQ. FT.DDD15' PUBLIC ALLEYPER VOLUME92228, PAGE 3876M.R.D.C.T.LOT 8, BLOCK DWATERS EDGE, PHASE TWOVOLUME 94144, PAGE 02344M.R.D.C.T.LOT 10, BLOCK DWATERS EDGE, PHASE TWOVOLUME 94144, PAGE 02344M.R.D.C.T.LOT 7, BLOCK DWATERS EDGE, PHASE TWOVOLUME 94144, PAGE 02344M.R.D.C.T.LOT 9, BLOCK DWATERS EDGE, PHASE TWOVOLUME 94144, PAGE 02344M.R.D.C.T.LANDSCAPE & SIDEWALK EASEMENTR VOLUME 94144, PAGE 2344M.R.D.C.T.30' FIRELANE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.25' FIRELANE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.20' DRAINAGE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.M.R.D.C.T.PER VOLUME 96147, PAGE 001130' BUILDING LINEVISIBILITYTRIANGLEPER VOLUME96147, PAGE 0011M.R.D.C.T.15' UTILITY, LANDSCAPE &SIDEWALK EASEMENTVOLUME 85095, PAGE 2840 &M.R.D.C.T.PER VOLUME 85186, PAGE 167030' BUILDING LINEVISIBILITY TRAINGLEPER VOLUME 96147, PAGE 0011M.R.D.C.T.VISIBILITY TRAINGLEPER VOLUME 96147, PAGE 0011M.R.D.C.T.WALL MAINTENANCE EASEMENTVOLUME 85186, PAGE 1670M.R.D.C.T.30' FIRELANEEASMENTPER VOLUME96147, PAGE 0011M.R.D.C.T.25' FIRELANE EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.SANDY LAKE ROADVARIABLE WIDTH RIGHT-OF-WAYRIGHT TURN EASMENTPER VOLUME 96147, PAGE 0011M.R.D.C.T.5' LONE STAR GAS EASMENTVOLUME 96147, PAGE 0011M.R.D.C.T.VISIBILITY TRAINGLEVOLUME 96147, PAGE 0011M.R.D.C.T.LUME 96147, PAGE15' UTILITY, LANDSCAPE &SIDEWALK EASEMENTVOLUME 96147, PAGE 0011M.R.D.C.T.VAN(52) IB(2) CP(2) CPPROPOSEDSTREET TREES(7) IV(7) LM(1) JE(7) LM(3) LM(1) LM(27) EXISTINGPARKING LOTTREE(5) EXISTINGPARKING LOTTREE(1) CP(PARKINGLOT TREE)(15) EXISTINGSTREET TREES(8) EXISTINGSTREET TREES(3) EXISTINGSTREET TREES(5) EXISTINGSTREET TREES(4) CPPROPOSEDSTREET TREES(2) CP(PARKINGLOT TREES)(42) EXISTINGCREPE MYRTLE(1) LM(10) JE(8) JE(6) JE(4) LM(225) LB(71) IB(16) IB(4) LMTHE CONTRACTOR SHALL INSTALL ROOT BARRIERS NEAR ALLNEWLY-PLANTED TREES THAT ARE LOCATED WITHIN FIVE (5) FEET OFPAVING OR CURBS. ROOT BARRIERS SHALL BE "CENTURY" OR"DEEP-ROOT" 24" DEEP PANELS (OR EQUAL). BARRIERS SHALL BELOCATED IMMEDIATELY ADJACENT TO HARDSCAPE. INSTALL PANELSPER MANUFACTURER'S RECOMMENDATIONS. UNDER NOCIRCUMSTANCES SHALL THE CONTRACTOR USE ROOT BARRIERS OF ATYPE THAT COMPLETELY ENCIRCLE THE ROOTBALL.ROOT BARRIERSMULCHESAFTER ALL PLANTING IS COMPLETE, CONTRACTOR SHALL INSTALL 3" THICKLAYER OF MULCH, TO MATCH EXISTING CONDITIONS, OVER LANDSCAPE FABRICIN ALL PLANTING AREAS (EXCEPT FOR TURF AND SEEDED AREAS). CONTRACTORSHALL SUBMIT SAMPLES OF ALL MULCHES TO LANDSCAPE ARCHITECT ANDOWNER FOR APPROVAL PRIOR TO CONSTRUCTION. ABSOLUTELY NO EXPOSEDGROUND SHALL BE LEFT SHOWING ANYWHERE ON THE PROJECT AFTER MULCHHAS BEEN INSTALLED (SUBJECT TO THE CONDITIONS AND REQUIREMENTS OFTHE "GENERAL GRADING AND PLANTING NOTES" AND SPECIFICATIONS).GENERAL GRADING AND PLANTING NOTES1. BY SUBMITTING A PROPOSAL FOR THE LANDSCAPE PLANTING SCOPE OF WORK, THE CONTRACTOR CONFIRMS THAT HE HASREAD, AND WILL COMPLY WITH, THE ASSOCIATED NOTES, SPECIFICATIONS, AND DETAILS WITH THIS PROJECT.2. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL EXISTING VEGETATION (EXCEPT WHERE NOTED TO REMAIN).3. IN THE CONTEXT OF THESE PLANS, NOTES, AND SPECIFICATIONS, "FINISH GRADE" REFERS TO THE FINAL ELEVATION OF THE SOILSURFACE (NOT TOP OF MULCH) AS INDICATED ON THE GRADING PLANS.a. BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE ROUGH GRADES OF ALL LANDSCAPEAREAS ARE WITHIN +/-0.1' OF FINISH GRADE. SEE SPECIFICATIONS FOR MORE DETAILED INSTRUCTION ON TURF AREA ANDPLANTING BED PREPARATION.b. CONSTRUCT AND MAINTAIN FINISH GRADES AS SHOWN ON GRADING PLANS, AND CONSTRUCT AND MAINTAIN SLOPES ASRECOMMENDED BY THE GEOTECHNICAL REPORT. ALL LANDSCAPE AREAS SHALL HAVE POSITIVE DRAINAGE AWAY FROMSTRUCTURES AT THE MINIMUM SLOPE SPECIFIED IN THE REPORT AND ON THE GRADING PLANS, AND AREAS OF POTENTIALPONDING SHALL BE REGRADED TO BLEND IN WITH THE SURROUNDING GRADES AND ELIMINATE PONDING POTENTIAL.c. THE LANDSCAPE CONTRACTOR SHALL DETERMINE WHETHER OR NOT THE EXPORT OF ANY SOIL WILL BE NEEDED, TAKINGINTO ACCOUNT THE ROUGH GRADE PROVIDED, THE AMOUNT OF SOIL AMENDMENTS TO BE ADDED (BASED ON A SOIL TEST,PER SPECIFICATIONS), AND THE FINISH GRADES TO BE ESTABLISHED.d. ENSURE THAT THE FINISH GRADE IN SHRUB AREAS IMMEDIATELY ADJACENT TO WALKS AND OTHER WALKING SURFACES,AFTER INSTALLING SOIL AMENDMENTS, IS 3" BELOW THE ADJACENT FINISH SURFACE, IN ORDER TO ALLOW FOR PROPERMULCH DEPTH. TAPER THE SOIL SURFACE TO MEET FINISH GRADE, AS SPECIFIED ON THE GRADING PLANS, ATAPPROXIMATELY 18" AWAY FROM THE WALKS.e. ENSURE THAT THE FINISH GRADE IN TURF AREAS IMMEDIATELY ADJACENT TO WALKS AND OTHER WALKING SURFACES,AFTER INSTALLING SOIL AMENDMENTS, IS 1" BELOW THE FINISH SURFACE OF THE WALKS. TAPER THE SOIL SURFACE TOMEET FINISH GRADE, AS SPECIFIED ON THE GRADING PLANS, AT APPROXIMATELY 18" AWAY FROM THE WALKS.f. SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GRADING PLANS, GEOTECHNICAL REPORT, THESENOTES AND PLANS, AND ACTUAL CONDITIONS, THE CONTRACTOR SHALL IMMEDIATELY BRING SUCH ITEMS TO THEATTENTION OF THE LANDSCAPE ARCHITECT, GENERAL CONTRACTOR, AND OWNER.4. ALL PLANT LOCATIONS ARE DIAGRAMMATIC. ACTUAL LOCATIONS SHALL BE VERIFIED WITH THE LANDSCAPE ARCHITECT ORDESIGNER PRIOR TO PLANTING. THE LANDSCAPE CONTRACTOR SHALL ENSURE THAT ALL REQUIREMENTS OF THE PERMITTINGAUTHORITY ARE MET (I.E., MINIMUM PLANT QUANTITIES, PLANTING METHODS, TREE PROTECTION METHODS, ETC.).a. THE LANDSCAPE CONTRACTOR IS RESPONSIBLE FOR DETERMINING PLANT QUANTITIES; PLANT QUANTITIES SHOWN ONLEGENDS AND CALLOUTS ARE FOR GENERAL INFORMATION ONLY. IN THE EVENT OF A DISCREPANCY BETWEEN THE PLANAND THE PLANT LEGEND, THE PLANT QUANTITY AS SHOWN ON THE PLAN (FOR INDIVIDUAL SYMBOLS) OR CALLOUT (FORGROUNDCOVER PATTERNS) SHALL TAKE PRECEDENCE.b.NO SUBSTITUTIONS OF PLANT MATERIALS SHALL BE ALLOWED WITHOUT THE WRITTEN PERMISSION OF THE LANDSCAPEARCHITECT. IF SOME OF THE PLANTS ARE NOT AVAILABLE, THE LANDSCAPE CONTRACTOR SHALL NOTIFY THE LANDSCAPEARCHITECT IN WRITING (VIA PROPER CHANNELS).c. THE CONTRACTOR SHALL, AT A MINIMUM, PROVIDE REPRESENTATIVE PHOTOS OF ALL PLANTS PROPOSED FOR THEPROJECT. THE CONTRACTOR SHALL ALLOW THE LANDSCAPE ARCHITECT AND THE OWNER/OWNER'S REPRESENTATIVE TOINSPECT, AND APPROVE OR REJECT, ALL PLANTS DELIVERED TO THE JOBSITE. REFER TO SPECIFICATIONS FORADDITIONAL REQUIREMENTS FOR SUBMITTALS.5. THE CONTRACTOR SHALL MAINTAIN THE LANDSCAPE IN A HEALTHY CONDITION FOR 90 DAYS AFTER ACCEPTANCE BY THEOWNER. REFER TO SPECIFICATIONS FOR CONDITIONS OF ACCEPTANCE FOR THE START OF THE MAINTENANCE PERIOD, ANDFOR FINAL ACCEPTANCE AT THE END OF THE MAINTENANCE PERIOD.6. SEE SPECIFICATIONS AND DETAILS FOR FURTHER REQUIREMENTS.
LANDSCAPE
PLANTING1. CONTRACTOR TO AUGMENT EXISTING IRRIGATION SYSTEMTO PROVIDE IRRIGATION TO NEWLY PLANTED AREAS.2. VERIFY EXISTING SYSTEM IS CAPABLE OF PROVIDINGNECESSARY WATERING FOR NEW PLANTING AREAS.3. CONTRACTOR SHALL ASSESS PLANT MATERIAL ANDREPLACE PLANTINGS THAT ARE SICK OR DEAD.4. LANDSCAPE CONTRACTOR SHALL INSPECT ALL EXISTINGTREES ALONG PERIMETER OF SITE. ANY EXISTING TREESTHAT HAVE BEEN REMOVED AND ARE MISSING FROM THELANDSCAPE PLAN WILL BE REQUIRED TO BE REPLACED.CONTRACTOR SHALL REPLACE TREE WITH LIKE SPECIES ASSHOWN ON THE LANDSCAPE PLAN WITH A MINIMUM 3” MINIMUMCALIPER.LANDSCAPE NOTESLANDSCAPE CALCULATIONSTOTAL SITE AREA:305,300 S.F.PERIMETER AREAPERIMETER - PUBLIC STREET 16,455 SF (1,097 LF)LANDSCAPE AREA REQUIRED: 1,645 SF (10%)LANDSCAPE AREA PROVIDED: 13,061 SF (79.3%)PERIMETER TREES REQUIRED: 22 TREES (1 / 50 LF)PERIMETER TREES PROVIDED: 37 TREES (31 EXISTING + 6 PROPOSED)PERIMETER - PROPERTY LINE 11,220 SF (1,122 LF)LANDSCAPE AREA REQUIRED: 1,122 SF (10%)LANDSCAPE AREA PROVIDED: 10,775 SF (96 %)PERIMETER TREES REQUIRED: 23 TREES (1 / 50 LF)PERIMETER TREES PROVIDED: 74 TREES (55 EXISTING + 19 PROPOSED)INTERIOR AREAVEHICLE USE AREA:145,909 SFLANDSCAPE AREA REQUIRED: 14,590 SF (10%)LANDSCAPE AREA PROVIDED: 19,840 SF (13.5 %)TREES REQUIRED:37 TREES (1 TREE / 400 SF = 36.4)TREES PROVIDED:37 TREES (32 EXISTING + 5 PROPOSED)PARKING SPACES:303 SPACESISLANDS REQUIRED:37 ISLANDS (12% OF PARKING SPACES)ISLANDS PROVIDED;42 ISLANDSTREES IN ISLANDS:PROVIDEDNON VEHICLE USE AREALOT AREA EXCLUDING BLDG:238,032 SFLANDSCAPE AREA REQUIRED: 35,704 SF (15% OF SITE EXCLUDING BUILDINGS)LANDSCAPE AREA PROVIDED: 21,693 SF (9.1 %)TREES REQUIRED:14 TREES (1 TREE / 2,500 SF = 14)TREES PROVIDED:16 TREES (EXISTING)LP-1Scale 1" = 30'15'60'30'0'PROPERTY LINEEXISTING SCREEN WALLEXISTING LANDSCAPETO REMAIN, TYP.DATENo.REVISION BYDATE:SHEETFile No. 2022-19406-07-2023CHECKED:EMS/RMDRAWN:EMSDESIGN:EMSKROGER 448
950 E. SANDY LAKERD.
COPPELL, TX TEXAS REGISTRATION #141991903 CENTRAL DR. SUITE #406 PHONE: 817.281.0572
BEDFORD, TX 76021 WWW.CLAYMOOREENG.COM.HIHI
C
SSTE
R
CCTTES
A
E
ETSTAIREG
73OF53ETX ERLDR
E
CAANDSMEPAPLEY(800) 680-663015455 Dallas Pkwy., Ste 600Addison, TX 75001www.EvergreenDesignGroup.comEVERGREEND E S I G N G R O U P08-09-2023PROPERTY LINEPROPERTY LINEPROPERTY LINEEXISTING LANDSCAPETO REMAIN, TYP.EXISTING LANDSCAPETO REMAIN, TYP.EXISTING LANDSCAPETO REMAIN, TYP.EXISTING LANDSCAPETO REMAIN, TYP.RESTORE TO LIMITSOF DISTURBANCEEXISTING RETAINING WALLEDGING BETWEENSHRUB AREA AND TURFEXISTING SCREEN WALLEDGING BETWEENSHRUB AREA AND TURFEDGING BETWEENSHRUB AREA AND TURFTREESCODEQTYBOTANICAL / COMMON NAMECAL.CONT.SIZE118 EX. SHADE TREE TO REMAIN42 EX CREPE MYRTLE TO REMAINIV 7Ilex vomitoria3" Cal.Cont. 8`-10`Yaupon HollyJE 26 Juniperus virginiana3" Cal.Cont. 8`-10`Eastern RedcedarLM 23 Lagerstroemia i. x f. 'Muskogee' 3" Cal. Cont. 8`-10`Crepe MyrtleCP 12 Pistancia chinensis3" Cal.Cont. or B&B 12`-14` HTChinese PistacheSHRUBSCODEQTYBOTANICAL / COMMON NAMECONTAINERSPACINGSIZEIB 139 Ilex cornuta `Burfordii`5 gal36" OC30" MinBurford HollySHRUB AREASCODEQTYBOTANICAL / COMMON NAMECONTSPACINGSIZE2,722 sf EX SHRUBGROUND COVERSCODEQTYBOTANICAL / COMMON NAMECONTSPACINGSIZELB 286 Liriope muscari 'Big Blue'4" Pot12" O.C.Big Blue LilyturfPLANT SCHEDULE LSPROPOSED SIGN -BY OTHERSCONTRACTOR TO EVALUATE ALL EXISTING TREES ONSITE. ANY TREE IN DECLINING HEALTH OR TREES THAT HAVE BEEN REMOVED DUE TO MAINTENANCE SHALL BE REPLACED OF LIKE SPECIES SHOWN ON LANDSCAPE PLAN. THE MINIMUM CALIPER FOR ANY REPLACEMENT TREE IS 3".DURING MAINTENANCE OF LANDSCAPE.CONTRACTOR TO REPLACE EXISTINGEASTERN RED CEDAR. CONTRACTORSHALL REVIEW ALL TREE LOCATIONS ANDREPLACE ANY MISSING OR DEAD TREES.EXISTING TREE HAS BEEN REMOVED
PLANT SPACINGSCALE: NTSC4X2X3215674123SHRUB, PERENNIAL, OR ORNAMENTAL GRASS.MULCH, TYPE AND DEPTH PER PLANS. PLACE NOMORE THAN 1" OF MULCH WITHIN 6" OF PLANTCENTER.FINISH GRADE.BACKFILL. AMEND AND FERTILIZE ONLY ASRECOMMENDED IN SOIL FERTILITY ANALYSIS.ROOT BALL.UNDISTURBED NATIVE SOIL.3" HIGH EARTHEN WATERING BASIN.567SHRUB AND PERENNIAL PLANTINGSCALE: NTSB8WEED FABRIC UNDER MULCH.8PLANTING SPECIFICATIONSFINISH GRADE.44321NOTES:1) INSTALL EDGING SO THAT STAKES WILL BE ON INSIDE OF PLANTING BED.2) BOTTOM OF EDGING SHALL BE BURIED A MINIMUM OF 1" BELOW FINISH GRADE.3) TOP OF MULCH SHALL BE 1" LOWER THAN TOP OF EDGING.MULCH, TYPE AND DEPTH PER PLANS.3TAPERED STEEL STAKES.2ROLLED-TOP STEEL EDGING PER PLANS.1DSCALE: NOT TO SCALESTEEL EDGINGTURF (WHERE SHOWN ON PLAN).4PLANT.3MULCH LAYER.2CURB.11432OF MATURE CANOPY24" MIN. TO EDGEDISTANCE PER PLANESCALE: NOT TO SCALEPLANTING AT PARKING AREATREE PLANTINGSCALE: NOT TO SCALEAPLANT CENTER (TYP.)EQUAL EQUALEQ
U
A
LEDGE OF PLANTING AREAEQUALNOTE: ALL PLANTS SHALL BE PLANTED AT EQUAL TRIANGULAR SPACING (EXCEPT WHERESHOWN ON PLANS AS INFORMAL GROUPINGS). REFER TO PLANT LEGEND FOR SPACINGDISTANCE BETWEEN PLANTS.1) STEP 1: DETERMINE TOTAL PLANTS FOR THE AREA WITH THE FOLLOWING FORMULA:TOTAL AREA / AREA DIVIDER = TOTAL PLANTSPLANT SPACINGAREA DIVIDERPLANT SPACINGAREA DIVIDER6"0.2218"1.958"0.3924"3.4610"0.6030"5.4112"0.8736"7.7915"1.352) STEP 2: SUBTRACT THE ROW (S) OF PLANTS THAT WOULD OCCUR AT THE EDGE OF THEPLANTED AREA WITH THE FOLLOWING FORMULA: TOTAL PERIMETER LENGTH / PLANTSPACING = TOTAL PLANT SUBTRACTIONEXAMPLE: PLANTS AT 18" O.C. IN 100 SF PLANTING AREA, 40 LF PERIMETERSTEP 1: 100 SF/1.95 = 51 PLANTSSTEP 2: 51 PLANTS - (40 LF / 1.95 = 21 PLANTS) = 30 PLANTS TOTAL5674189111012PREVAILINGWINDSNOTES:1. SCARIFY SIDES OF PLANTING PIT PRIOR TO SETTING TREE.2. REMOVE EXCESS SOIL APPLIED ON TOP OF THE ROOTBALL THATCOVERS THE ROOT FLARE. THE PLANTING HOLE DEPTH SHALL BESUCH THAT THE ROOTBALL RESTS ON UNDISTURBED SOIL, AND THEROOT FLARE IS 2"-4" ABOVE FINISH GRADE.3. FOR B&B TREES, CUT OFF BOTTOM 1/3 OF WIRE BASKET BEFOREPLACING TREE IN HOLE, CUT OFF AND REMOVE REMAINDER OFBASKET AFTER TREE IS SET IN HOLE, REMOVE ALL NYLON TIES,TWINE, ROPE, AND OTHER PACKING MATERIAL. REMOVE AS MUCHBURLAP FROM AROUND ROOTBALL AS IS PRACTICAL.4. REMOVE ALL NURSERY STAKES AFTER PLANTING.5. FOR TREES 36" BOX/2.5" CAL. AND LARGER, USE THREE STAKES ORDEADMEN (AS APPROPRIATE), SPACED EVENLY AROUND TREE.6. STAKING SHALL BE TIGHT ENOUGH TO PREVENT TRUNK FROMBENDING, BUT LOOSE ENOUGH TO ALLOW SOME TRUNK MOVEMENTIN WIND.123TREE CANOPY.CINCH-TIES (24" BOX/2" CAL. TREES AND SMALLER) OR12 GAUGE GALVANIZED WIRE WITH NYLON TREESTRAPS AT TREE AND STAKE (36" BOX/2.5" CAL. TREESAND LARGER). SECURE TIES OR STRAPS TO TRUNKJUST ABOVE LOWEST MAJOR BRANCHES.GREEN STEEL T-POSTS. EXTEND POSTS 12" MIN. INTOUNDISTURBED SOIL.24" X 3/4" P.V.C. MARKERS OVER WIRES.PRESSURE-TREATED WOOD DEADMAN, TWO PERTREE (MIN.). BURY OUTSIDE OF PLANTING PIT AND18" MIN. INTO UNDISTURBED SOIL.MULCH, TYPE AND DEPTH PER PLANS. DO NOTPLACE MULCH WITHIN 6" OF TRUNK.FINISH GRADE.BACKFILL. AMEND AND FERTILIZE ONLY ASRECOMMENDED IN SOIL FERTILITY ANALYSIS.ROOT BALL.UNDISTURBED NATIVE SOIL.4" HIGH EARTHEN WATERING BASIN.TRUNK FLARE.CONIFEROUSTREEPREVAILINGWINDSSTAKING EXAMPLES (PLAN VIEW)2467891011143X ROOTBALL DIA.523512NON-CONIFEROUSTREE1313FINISH GRADE.ROOT BARRIER - PLAN VIEWSCALE: NOT TO SCALEFGENERALA. QUALIFICATIONS OF LANDSCAPE CONTRACTOR1. ALL LANDSCAPE WORK SHOWN ON THESE PLANS SHALL BE PERFORMED BY A SINGLE FIRM SPECIALIZING INLANDSCAPE PLANTING.2. A LIST OF SUCCESSFULLY COMPLETED PROJECTS OF THIS TYPE, SIZE AND NATURE MAY BE REQUESTED BY THEOWNER FOR FURTHER QUALIFICATION MEASURES.3. THE LANDSCAPE CONTRACTOR SHALL HOLD A VALID NURSERY AND FLORAL CERTIFICATE ISSUED BY THE TEXASDEPARTMENT OF AGRICULTURE, AS WELL AS OPERATE UNDER A COMMERCIAL PESTICIDE APPLICATOR LICENSEISSUED BY EITHER THE TEXAS DEPARTMENT OF AGRICULTURE OR THE TEXAS STRUCTURAL PEST CONTROL BOARD.3. THE LANDSCAPE CONTRACTOR SHALL HOLD A VALID CONTRACTOR'S LICENSE ISSUED BY THE APPROPRIATE LOCALJURISDICTION.B. SCOPE OF WORK1. WORK COVERED BY THESE SECTIONS INCLUDES THE FURNISHING AND PAYMENT OF ALL MATERIALS, LABOR,SERVICES, EQUIPMENT, LICENSES, TAXES AND ANY OTHER ITEMS THAT ARE NECESSARY FOR THE EXECUTION,INSTALLATION AND COMPLETION OF ALL WORK, SPECIFIED HEREIN AND / OR SHOWN ON THE LANDSCAPE PLANS,NOTES, AND DETAILS.2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE LAWS, CODES AND REGULATIONSREQUIRED BY AUTHORITIES HAVING JURISDICTION OVER SUCH WORK, INCLUDING ALL INSPECTIONS AND PERMITSREQUIRED BY FEDERAL, STATE AND LOCAL AUTHORITIES IN SUPPLY, TRANSPORTATION AND INSTALLATION OFMATERIALS.3. THE LANDSCAPE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UNDERGROUND UTILITY LINES (WATER, SEWER,ELECTRICAL, TELEPHONE, GAS, CABLE, TELEVISION, ETC.) PRIOR TO THE START OF ANY WORK.PRODUCTSA. ALL MANUFACTURED PRODUCTS SHALL BE NEW.B. CONTAINER AND BALLED-AND-BURLAPPED PLANTS:1. FURNISH NURSERY-GROWN PLANTS COMPLYING WITH ANSI Z60.1-2014. PROVIDE WELL-SHAPED, FULLY BRANCHED,HEALTHY, VIGOROUS STOCK FREE OF DISEASE, INSECTS, EGGS, LARVAE, AND DEFECTS SUCH AS KNOTS, SUNSCALD, INJURIES, ABRASIONS, AND DISFIGUREMENT. ALL PLANTS WITHIN A SPECIES SHALL HAVE SIMILAR SIZE, ANDSHALL BE OF A FORM TYPICAL FOR THE SPECIES. ALL TREES SHALL BE OBTAINED FROM SOURCES WITHIN 200 MILESOF THE PROJECT SITE, AND WITH SIMILAR CLIMACTIC CONDITIONS.2. ROOT SYSTEMS SHALL BE HEALTHY, DENSELY BRANCHED ROOT SYSTEMS, NON-POT-BOUND, FREE FROMENCIRCLING AND/OR GIRDLING ROOTS, AND FREE FROM ANY OTHER ROOT DEFECTS (SUCH AS J-SHAPED ROOTS).3. TREES MAY BE PLANTED FROM CONTAINERS OR BALLED-AND-BURLAPPED (B&B), UNLESS SPECIFIED ON THEPLANTING LEGEND. BARE-ROOT TREES ARE NOT ACCEPTABLE.4. ANY PLANT DEEMED UNACCEPTABLE BY THE LANDSCAPE ARCHITECT OR OWNER SHALL BE IMMEDIATELY REMOVEDFROM THE SITE AND SHALL BE REPLACED WITH AN ACCEPTBLE PLANT OF LIKE TYPE AND SIZE AT THECONTRACTOR'S OWN EXPENSE. ANY PLANTS APPEARING TO BE UNHEALTHY, EVEN IF DETERMINED TO STILL BEALIVE, SHALL NOT BE ACCEPTED. THE LANDSCAPE ARCHITECT AND OWNER SHALL BE THE SOLE JUDGES AS TO THEACCEPTABILITY OF PLANT MATERIAL.5. ALL TREES SHALL BE STANDARD IN FORM, UNLESS OTHERWISE SPECIFIED. TREES WITH CENTRAL LEADERS WILLNOT BE ACCEPTED IF LEADER IS DAMAGED OR REMOVED. PRUNE ALL DAMAGED TWIGS AFTER PLANTING.6. CALIPER MEASUREMENTS FOR STANDARD (SINGLE TRUNK) TREES SHALL BE AS FOLLOWS: SIX INCHES ABOVE THEROOT FLARE FOR TREES UP TO AND INCLUDING FOUR INCHES IN CALIPER, AND TWELVE INCHES ABOVE THE ROOTFLARE FOR TREES EXCEEDING FOUR INCHES IN CALIPER.7. MULTI-TRUNK TREES SHALL BE MEASURED BY THEIR OVERALL HEIGHT, MEASURED FROM THE TOP OF THE ROOTBALL. WHERE CALIPER MEASUREMENTS ARE USED, THE CALIPER SHALL BE CALCULATED AS ONE-HALF OF THE SUMOF THE CALIPER OF THE THREE LARGEST TRUNKS.8. ANY TREE OR SHRUB SHOWN TO HAVE EXCESS SOIL PLACED ON TOP OF THE ROOT BALL, SO THAT THE ROOT FLAREHAS BEEN COMPLETELY COVERED, SHALL BE REJECTED.C. SOD: PROVIDE WELL-ROOTED SOD OF THE VARIETY NOTED ON THE PLANS. SOD SHALL BE CUT FROM HEALTHY, MATURETURF WITH SOIL THICKNESS OF 3/4" TO 1". EACH PALLET OF SOD SHALL BE ACCOMPANIED BY A CERTIFICATE FROMSUPPLIER STATING THE COMPOSITION OF THE SOD.D. SEED: PROVIDE BLEND OF SPECIES AND VARIETIES AS NOTED ON THE PLANS, WITH MAXIMUM PERCENTAGES OF PURITY,GERMINATION, AND MINIMUM PERCENTAGE OF WEED SEED AS INDICATED ON PLANS. EACH BAG OF SEED SHALL BEACCOMPANIED BY A TAG FROM THE SUPPLIER INDICATING THE COMPOSITION OF THE SEED.E. TOPSOIL: SANDY TO CLAY LOAM TOPSOIL, FREE OF STONES LARGER THAN ½ INCH, FOREIGN MATTER, PLANTS, ROOTS,AND SEEDS.F. COMPOST: WELL-COMPOSTED, STABLE, AND WEED-FREE ORGANIC MATTER, pH RANGE OF 5.5 TO 8; MOISTURE CONTENT35 TO 55 PERCENT BY WEIGHT; 100 PERCENT PASSING THROUGH 3/4-INCH SIEVE; SOLUBLE SALT CONTENT OF 5 TO 10DECISIEMENS/M; NOT EXCEEDING 0.5 PERCENT INERT CONTAMINANTS AND FREE OF SUBSTANCES TOXIC TO PLANTINGS.NO MANURE OR ANIMAL-BASED PRODUCTS SHALL BE USED.G. FERTILIZER: GRANULAR FERTILIZER CONSISTING OF NITROGEN, PHOSPHORUS, POTASSIUM, AND OTHER NUTRIENTS INPROPORTIONS, AMOUNTS, AND RELEASE RATES RECOMMENDED IN A SOIL REPORT FROM A QUALIFIED SOIL-TESTINGAGENCY (SEE BELOW).H. MULCH: SIZE AND TYPE AS INDICATED ON PLANS, FREE FROM DELETERIOUS MATERIALS AND SUITABLE AS A TOPDRESSING OF TREES AND SHRUBS.I. TREE STAKING AND GUYING1. STAKES: 6' LONG GREEN METAL T-POSTS.2. GUY AND TIE WIRE: ASTM A 641, CLASS 1, GALVANIZED-STEEL WIRE, 2-STRAND, TWISTED, 0.106 INCH DIAMETER.3. STRAP CHAFING GUARD: REINFORCED NYLON OR CANVAS AT LEAST 1-1/2 INCH WIDE, WITH GROMMETS TO PROTECTTREE TRUNKS FROM DAMAGE.L. STEEL EDGING: PROFESSIONAL STEEL EDGING, 14 GAUGE THICK X 4 INCHES WIDE, FACTORY PAINTED DARK GREEN.ACCEPTABLE MANUFACTURERS INCLUDE COL-MET OR APPROVED EQUAL.M. PRE-EMERGENT HERBICIDES: ANY GRANULAR, NON-STAINING PRE-EMERGENT HERBICIDE THAT IS LABELED FOR THESPECIFIC ORNAMENTALS OR TURF ON WHICH IT WILL BE UTILIZED. PRE-EMERGENT HERBICIDES SHALL BE APPLIED PERTHE MANUFACTURER'S LABELED RATES.METHODSA. SOIL PREPARATION1. BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE GRADE OF ALL LANDSCAPEAREAS ARE WITHIN +/-0.1' OF FINISH GRADE. THE CONTRACTOR SHALL NOTIFY THE OWNER IMMEDIATELY SHOULDANY DISCREPANCIES EXIST.2. SOIL TESTING:a. AFTER FINISH GRADES HAVE BEEN ESTABLISHED, CONTRACTOR SHALL HAVE SOIL SAMPLES FROM THEPROJECT'S LANDSCAPE AREAS TESTED BY AN ESTABLISHED SOIL TESTING LABORATORY. EACH SAMPLESUBMITTED TO THE LAB SHALL CONTAIN NO LESS THAN ONE QUART OF SOIL, TAKEN FROM BETWEEN THE SOILSURFACE AND 6" DEPTH. IF NO SAMPLE LOCATIONS ARE INDICATED ON THE PLANS, THE CONTRACTOR SHALLTAKE A MINIMUM OF THREE SAMPLES FROM VARIOUS REPRESENTATIVE LOCATIONS FOR TESTING.b. THE CONTRACTOR SHALL HAVE THE SOIL TESTING LABORATORY PROVIDE RESULTS FOR THE FOLLOWING:SOIL TEXTURAL CLASS, GENERAL SOIL FERTILITY, pH, ORGANIC MATTER CONTENT, SALT (CEC), LIME, SODIUMADSORPTION RATIO (SAR) AND BORON CONTENT.c. THE CONTRACTOR SHALL ALSO SUBMIT THE PROJECT'S PLANT LIST TO THE LABORATORY ALONG WITH THESOIL SAMPLES.d. THE SOIL REPORT PRODUCED BY THE LABORATORY SHALL CONTAIN RECOMMENDATIONS FOR THE FOLLOWING(AS APPROPRIATE): SEPARATE SOIL PREPARATION AND BACKFILL MIX RECOMMENDATIONS FOR GENERALORNAMENTAL PLANTS, XERIC PLANTS, TURF, AND NATIVE SEED, AS WELL AS PRE-PLANT FERTILIZERAPPLICATIONS AND RECOMMENDATIONS FOR ANY OTHER SOIL RELATED ISSUES. THE REPORT SHALL ALSOPROVIDE A FERTILIZER PROGRAM FOR THE ESTABLISHMENT PERIOD AND FOR LONG-TERM MAINTENANCE.3. THE CONTRACTOR SHALL INSTALL SOIL AMENDMENTS AND FERTILIZERS PER THE SOILS REPORTRECOMMENDATIONS. ANY CHANGE IN COST DUE TO THE SOIL REPORT RECOMMENDATIONS, EITHER INCREASE ORDECREASE, SHALL BE SUBMITTED TO THE OWNER WITH THE REPORT.4.FOR BIDDING PURPOSES ONLY, THE SOIL PREPARATION SHALL CONSIST OF THE FOLLOWING:a. TURF: INCORPORATE THE FOLLOWING AMENDMENTS INTO THE TOP 8" OF SOIL BY MEANS OF ROTOTILLINGAFTER CROSS-RIPPING:i. NITROGEN STABILIZED ORGANIC AMENDMENT - 4 CU. YDS. PER 1,000 S.F.ii. PREPLANT TURF FERTILIZER (10-20-10 OR SIMILAR, SLOW RELEASE, ORGANIC) - 15 LBS PER 1,000 S.F.iii. "CLAY BUSTER" OR EQUAL - USE MANUFACTURER'S RECOMMENDED RATEb. TREES, SHRUBS, AND PERENNIALS: INCORPORATE THE FOLLOWING AMENDMENTS INTO THE TOP 8" OF SOIL BYMEANS OF ROTOTILLING AFTER CROSS-RIPPING:i. NITROGEN STABILIZED ORGANIC AMENDMENT - 4 CU. YDS. PER 1,000 S.F.ii. 12-12-12 FERTILIZER (OR SIMILAR, ORGANIC, SLOW RELEASE) - 10 LBS. PER CU. YD.iii. "CLAY BUSTER" OR EQUAL - USE MANUFACTURER'S RECOMMENDED RATEiv. IRON SULPHATE - 2 LBS. PER CU. YD.5. IN THE CONTEXT OF THESE PLANS, NOTES, AND SPECIFICATIONS, "FINISH GRADE" REFERS TO THE FINAL ELEVATIONOF THE SOIL SURFACE (NOT TOP OF MULCH) AS INDICATED ON THE GRADING PLANS.a. BEFORE STARTING WORK, THE LANDSCAPE CONTRACTOR SHALL VERIFY THAT THE ROUGH GRADES OF ALLLANDSCAPE AREAS ARE WITHIN +/-0.1' OF FINISH GRADE. SEE SPECIFICATIONS FOR MORE DETAILEDINSTRUCTION ON TURF AREA AND PLANTING BED PREPARATION.b. CONSTRUCT AND MAINTAIN FINISH GRADES AS SHOWN ON GRADING PLANS, AND CONSTRUCT AND MAINTAINSLOPES AS RECOMMENDED BY THE GEOTECHNICAL REPORT. ALL LANDSCAPE AREAS SHALL HAVE POSITIVEDRAINAGE AWAY FROM STRUCTURES AT THE MINIMUM SLOPE SPECIFIED IN THE REPORT AND ON THE GRADINGPLANS, AND AREAS OF POTENTIAL PONDING SHALL BE REGRADED TO BLEND IN WITH THE SURROUNDINGGRADES AND ELIMINATE PONDING POTENTIAL.c. THE LANDSCAPE CONTRACTOR SHALL DETERMINE WHETHER OR NOT THE EXPORT OF ANY SOIL WILL BENEEDED, TAKING INTO ACCOUNT THE ROUGH GRADE PROVIDED, THE AMOUNT OF SOIL AMENDMENTS TO BEADDED (BASED ON A SOIL TEST, PER SPECIFICATIONS), AND THE FINISH GRADES TO BE ESTABLISHED.d. ENSURE THAT THE FINISH GRADE IN SHRUB AREAS IMMEDIATELY ADJACENT TO WALKS AND OTHER WALKINGSURFACES, AFTER INSTALLING SOIL AMENDMENTS, IS 3" BELOW THE ADJACENT FINISH SURFACE, IN ORDER TOALLOW FOR PROPER MULCH DEPTH. TAPER THE SOIL SURFACE TO MEET FINISH GRADE, AS SPECIFIED ON THEGRADING PLANS, AT APPROXIMATELY 18" AWAY FROM THE WALKS.e. ENSURE THAT THE FINISH GRADE IN TURF AREAS IMMEDIATELY ADJACENT TO WALKS AND OTHER WALKINGSURFACES, AFTER INSTALLING SOIL AMENDMENTS, IS 1" BELOW THE FINISH SURFACE OF THE WALKS. TAPERTHE SOIL SURFACE TO MEET FINISH GRADE, AS SPECIFIED ON THE GRADING PLANS, AT APPROXIMATELY 18"AWAY FROM THE WALKS.f. SHOULD ANY CONFLICTS AND/OR DISCREPANCIES ARISE BETWEEN THE GRADING PLANS, GEOTECHNICALREPORT, THESE NOTES AND PLANS, AND ACTUAL CONDITIONS, THE CONTRACTOR SHALL IMMEDIATELY BRINGSUCH ITEMS TO THE ATTENTION OF THE LANDSCAPE ARCHITECT, GENERAL CONTRACTOR, AND OWNER.6. ONCE SOIL PREPARATION IS COMPLETE, THE LANDSCAPE CONTRACTOR SHALL ENSURE THAT THERE ARE NODEBRIS, TRASH, OR STONES LARGER THAN 1" REMAINING IN THE TOP 6" OF SOIL.B. SUBMITTALS1. THE CONTRACTOR SHALL PROVIDE SUBMITTALS AND SAMPLES, IF REQUIRED, TO THE LANDSCAPE ARCHITECT,AND RECEIVE APPROVAL IN WRITING FOR SUCH SUBMITTALS BEFORE WORK COMMENCES.2. SUBMITTALS SHALL INCLUDE PHOTOS OF PLANTS WITH A RULER OR MEASURING STICK FOR SCALE, PHOTOSOR SAMPLES OF ANY REQUIRED MULCHES, AND SOIL TEST RESULTS AND PREPARATION RECOMMENDATIONSFROM THE TESTING LAB (INCLUDING COMPOST AND FERTILIZER RATES AND TYPES, AND OTHER AMENDMENTSFOR TREE/SHRUB, TURF, AND SEED AREAS AS MAY BE APPROPRIATE).3. SUBMITTALS SHALL ALSO INCLUDE MANUFACTURER CUT SHEETS FOR PLANTING ACCESSORIES SUCH AS TREESTAKES AND TIES, EDGING, AND LANDSCAPE FABRICS (IF ANY).4. WHERE MULTIPLE ITEMS ARE SHOWN ON A PAGE, THE CONTRACTOR SHALL CLEARLY INDICATE THE ITEM BEINGCONSIDERED.C. GENERAL PLANTING1. REMOVE ALL NURSERY TAGS AND STAKES FROM PLANTS.2. EXCEPT IN AREAS TO BE PLANTED WITH ORNAMENTAL GRASSES, APPLY PRE-EMERGENT HERBICIDES AT THEMANUFACTURER'S RECOMMENDED RATE.3. TRENCHING NEAR EXISTING TREES:a. CONTRACTOR SHALL NOT DISTURB ROOTS 1-1/2" AND LARGER IN DIAMETER WITHIN THE CRITICAL ROOTZONE (CRZ) OF EXISTING TREES, AND SHALL EXERCISE ALL POSSIBLE CARE AND PRECAUTIONS TO AVOIDINJURY TO TREE ROOTS, TRUNKS, AND BRANCHES. THE CRZ IS DEFINED AS A CIRCULAR AREAEXTENDING OUTWARD FROM THE TREE TRUNK, WITH A RADIUS EQUAL TO 1' FOR EVERY 1" OF TRUNKDIAMETER-AT-BREAST-HEIGHT (4.5' ABOVE THE AVERAGE GRADE AT THE TRUNK).b. ALL EXCAVATION WITHIN THE CRZ SHALL BE PERFORMED USING HAND TOOLS. NO MACHINE EXCAVATIONOR TRENCHING OF ANY KIND SHALL BE ALLOWED WITHIN THE CRZ.c. ALTER ALIGNMENT OF PIPE TO AVOID TREE ROOTS 1-1/2" AND LARGER IN DIAMETER. WHERE TREE ROOTS1-1/2" AND LARGER IN DIAMETER ARE ENCOUNTERED IN THE FIELD, TUNNEL UNDER SUCH ROOTS. WRAPEXPOSED ROOTS WITH SEVERAL LAYERS OF BURLAP AND KEEP MOIST. CLOSE ALL TRENCHES WITHINTHE CANOPY DRIP LINES WITHIN 24 HOURS.d. ALL SEVERED ROOTS SHALL BE HAND PRUNED WITH SHARP TOOLS AND ALLOWED TO AIR-DRY. DO NOTUSE ANY SORT OF SEALERS OR WOUND PAINTS.C. TREE PLANTING1. TREE PLANTING HOLES SHALL BE EXCAVATED TO MINIMUM WIDTH OF TWO TIMES THE WIDTH OF THEROOTBALL, AND TO A DEPTH EQUAL TO THE DEPTH OF THE ROOTBALL LESS TWO TO FOUR INCHES.2. SCARIFY THE SIDES AND BOTTOM OF THE PLANTING HOLE PRIOR TO THE PLACEMENT OF THE TREE. REMOVEANY GLAZING THAT MAY HAVE BEEN CAUSED DURING THE EXCAVATION OF THE HOLE.3. FOR CONTAINER AND BOX TREES, TO REMOVE ANY POTENTIALLY GIRDLING ROOTS AND OTHER ROOTDEFECTS, THE CONTRACTOR SHALL SHAVE A 1" LAYER OFF OF THE SIDES AND BOTTOM OF THE ROOTBALL OFALL TREES JUST BEFORE PLACING INTO THE PLANTING PIT. DO NOT "TEASE" ROOTS OUT FROM THE ROOTBALL.4. INSTALL THE TREE ON UNDISTURBED SUBGRADE SO THAT THE TOP OF THE ROOTBALL IS TWO TO FOUR INCHESABOVE THE SURROUNDING GRADE.5. BACKFILL THE TREE HOLE UTILIZING THE EXISTING TOPSOIL FROM ON-SITE. ROCKS LARGER THAN 1" DIA. ANDALL OTHER DEBRIS SHALL BE REMOVED FROM THE SOIL PRIOR TO THE BACKFILL. SHOULD ADDITIONAL SOIL BEREQUIRED TO ACCOMPLISH THIS TASK, USE STORED TOPSOIL FROM ON-SITE OR IMPORT ADDITIONAL TOPSOILFROM OFF-SITE AT NO ADDITIONAL COST TO THE OWNER. IMPORTED TOPSOIL SHALL BE OF SIMILAR TEXTURALCLASS AND COMPOSITION IN THE ON-SITE SOIL.6. TREES SHALL NOT BE STAKED UNLESS LOCAL CONDITIONS (SUCH AS HEAVY WINDS OR SLOPES) REQUIRESTAKES TO KEEP TREES UPRIGHT. SHOULD STAKING BE REQUIRED, THE TOTAL NUMBER OF TREE STAKES(BEYOND THE MINIMUMS LISTED BELOW) WILL BE LEFT TO THE LANDSCAPE CONTRACTOR'S DISCRETION.SHOULD ANY TREES FALL OR LEAN, THE LANDSCAPE CONTRACTOR SHALL STRAIGHTEN THE TREE, ORREPLACE IT SHOULD IT BECOME DAMAGED. TREE STAKING SHALL ADHERE TO THE FOLLOWING GUIDELINES:a. 1"-2" TREESTWO STAKES PER TREEb. 2-1/2"-4" TREESTHREE STAKES PER TREEc. TREES OVER 4" CALIPER GUY AS NEEDEDd. MULTI-TRUNK TREES THREE STAKES PER TREE MINIMUM, QUANTITY AND POSITIONS AS NEEDEDTO STABILIZE THE TREEe. #15 CONT. - 24" BOX TREES TWO STAKES PER TREEf. 36"-48" BOX TREESTHREE STAKES PER TREEg. OVER 48" BOX TREES GUY AS NEEDEDh. MULTI-TRUNK TREES THREE STAKES PER TREE MINIMUM, QUANTITY AND POSITIONS AS NEEDEDTO STABILIZE THE TREE7. UPON COMPLETION OF PLANTING, CONSTRUCT AN EARTH WATERING BASIN AROUND THE TREE. COVER THEINTERIOR OF THE TREE RING WITH THE WEED BARRIER CLOTH AND TOPDRESS WITH MULCH (TYPE AND DEPTHPER PLANS).D. SHRUB, PERENNIAL, AND GROUNDCOVER PLANTING1. DIG THE PLANTING HOLES TWICE AS WIDE AND 2" LESS DEEP THAN EACH PLANT'S ROOTBALL. INSTALL THEPLANT IN THE HOLE. BACKFILL AROUND THE PLANT WITH SOIL AMENDED PER SOIL TEST RECOMMENDATIONS.2. INSTALL THE WEED BARRIER CLOTH, OVERLAPPING IT AT THE ENDS. UTILIZE STEEL STAPLES TO KEEP THEWEED BARRIER CLOTH IN PLACE.3. WHEN PLANTING IS COMPLETE, INSTALL MULCH (TYPE AND DEPTH PER PLANS) OVER ALL PLANTING BEDS,COVERING THE ENTIRE PLANTING AREA.E. SODDING1. SOD VARIETY TO BE AS SPECIFIED ON THE LANDSCAPE PLAN.2. LAY SOD WITHIN 24 HOURS FROM THE TIME OF STRIPPING. DO NOT LAY IF THE GROUND IS FROZEN.3. LAY THE SOD TO FORM A SOLID MASS WITH TIGHTLY FITTED JOINTS. BUTT ENDS AND SIDES OF SOD STRIPS -DO NOT OVERLAP. STAGGER STRIPS TO OFFSET JOINTS IN ADJACENT COURSES.4. ROLL THE SOD TO ENSURE GOOD CONTACT OF THE SOD'S ROOT SYSTEM WITH THE SOIL UNDERNEATH.5. WATER THE SOD THOROUGHLY WITH A FINE SPRAY IMMEDIATELY AFTER PLANTING TO OBTAIN AT LEAST SIXINCHES OF PENETRATION INTO THE SOIL BELOW THE SOD.H. MULCH1. INSTALL MULCH TOPDRESSING, TYPE AND DEPTH PER MULCH NOTE, IN ALL PLANTING AREAS AND TREE RINGS.2. DO NOT INSTALL MULCH WITHIN 6" OF TREE ROOT FLARE AND WITHIN 24" OF HABITABLE STRUCTURES, EXCEPTAS MAY BE NOTED ON THESE PLANS. MULCH COVER WITHIN 6" OF CONCRETE WALKS AND CURBS SHALL NOTPROTRUDE ABOVE THE FINISH SURFACE OF THE WALKS AND CURBS. MULCH COVER WITHIN 12" OF WALLSSHALL BE AT LEAST 3" LOWER THAN THE TOP OF WALL.I. CLEAN UP1. DURING LANDSCAPE PREPARATION AND PLANTING, KEEP ALL PAVEMENT CLEAN AND ALL WORK AREAS IN ANEAT, ORDERLY CONDITION.2. DISPOSED LEGALLY OF ALL EXCAVATED MATERIALS OFF THE PROJECT SITE.J. INSPECTION AND ACCEPTANCE1. UPON COMPLETION OF THE WORK, THE LANDSCAPE CONTRACTOR SHALL PROVIDE THE SITE CLEAN, FREE OFDEBRIS AND TRASH, AND SUITABLE FOR USE AS INTENDED. THE LANDSCAPE CONTRACTOR SHALL THENREQUEST AN INSPECTION BY THE OWNER TO DETERMINE FINAL ACCEPTABILITY.2. WHEN THE INSPECTED PLANTING WORK DOES NOT COMPLY WITH THE CONTRACT DOCUMENTS, THELANDSCAPE CONTRACTOR SHALL REPLACE AND/OR REPAIR THE REJECTED WORK TO THE OWNER'SSATISFACTION WITHIN 24 HOURS.3. THE LANDSCAPE MAINTENANCE PERIOD WILL NOT COMMENCE UNTIL THE LANDSCAPE WORK HAS BEENRE-INSPECTED BY THE OWNER AND FOUND TO BE ACCEPTABLE. AT THAT TIME, A WRITTEN NOTICE OF FINALACCEPTANCE WILL BE ISSUED BY THE OWNER, AND THE MAINTENANCE AND GUARANTEE PERIODS WILLCOMMENCE.K. LANDSCAPE MAINTENANCE1. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL WORK SHOWN ONTHESE PLANS FOR 90 DAYS BEYOND FINAL ACCEPTANCE OF ALL LANDSCAPE WORK BY THE OWNER.LANDSCAPE MAINTENANCE SHALL INCLUDE WEEKLY SITE VISITS FOR THE FOLLOWING ACTIONS (ASAPPROPRIATE): PROPER PRUNING, RESTAKING OF TREES, RESETTING OF PLANTS THAT HAVE SETTLED,MOWING AND AERATION OF LAWNS, WEEDING, RESEEDING AREAS WHICH HAVE NOT GERMINATED WELL,TREATING FOR INSECTS AND DISEASES,REPLACEMENT OF MULCH, REMOVAL OF LITTER, REPAIRS TO THEIRRIGATION SYSTEM DUE TO FAULTY PARTS AND/OR WORKMANSHIP, AND THE APPROPRIATE WATERING OF ALLPLANTINGS. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE IRRIGATION SYSTEM IN PROPER WORKINGORDER, WITH SCHEDULING ADJUSTMENTS BY SEASON TO MAXIMIZE WATER CONSERVATION.2. SHOULD SEEDED AND/OR SODDED AREAS NOT BE COVERED BY AN AUTOMATIC IRRIGATION SYSTEM, THELANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR WATERING THESE AREAS AND OBTAINING A FULL,HEALTHY STAND OF PLANTS AT NO ADDITIONAL COST TO THE OWNER.3. TO ACHIEVE FINAL ACCEPTANCE AT THE END OF THE MAINTENANCE PERIOD, ALL OF THE FOLLOWINGCONDITIONS MUST OCCUR:a. THE LANDSCAPE SHALL SHOW ACTIVE, HEALTHY GROWTH (WITH EXCEPTIONS MADE FOR SEASONALDORMANCY). ALL PLANTS NOT MEETING THIS CONDITION SHALL BE REJECTED AND REPLACED BYHEALTHY PLANT MATERIAL PRIOR TO FINAL ACCEPTANCE.b. ALL HARDSCAPE SHALL BE CLEANED PRIOR TO FINAL ACCEPTANCE.c. SODDED AREAS MUST BE ACTIVELY GROWING AND MUST REACH A MINIMUM HEIGHT OF 1 1/2 INCHESBEFORE FIRST MOWING. HYDROMULCHED AREAS SHALL SHOW ACTIVE, HEALTHY GROWTH. BAREAREAS LARGER THAN TWELVE SQUARE INCHES MUST BE RESODDED OR RESEEDED (AS APPROPRIATE)PRIOR TO FINAL ACCEPTANCE. ALL SODDED TURF SHALL BE NEATLY MOWED.L. WARRANTY PERIOD, PLANT GUARANTEE AND REPLACEMENTS1. THE LANDSCAPE CONTRACTOR SHALL GUARANTEE ALL TREES, SHRUBS, PERENNIALS, SOD,SEEDED/HYDROMULCHED AREAS, AND IRRIGATION SYSTEMS FOR A PERIOD OF ONE YEAR FROM THE DATE OFTHE OWNER'S FINAL ACCEPTANCE (90 DAYS FOR ANNUAL PLANTS). THE CONTRACTOR SHALL REPLACE, AT HISOWN EXPENSE AND TO THE SATISFACTION OF THE OWNER, ANY PLANTS WHICH DIE IN THAT TIME, OR REPAIRANY PORTIONS OF THE IRRIGATION SYSTEM WHICH OPERATE IMPROPERLY.2. AFTER THE INITIAL MAINTENANCE PERIOD AND DURING THE GUARANTEE PERIOD, THE LANDSCAPECONTRACTOR SHALL ONLY BE RESPONSIBLE FOR REPLACEMENT OF PLANTS WHEN PLANT DEATH CANNOT BEATTRIBUTED DIRECTLY TO OVERWATERING OR OTHER DAMAGE BY HUMAN ACTIONS.M. PROVIDE A MINIMUM OF (2) COPIES OF RECORD DRAWINGS TO THE OWNER UPON COMPLETION OF WORK. A RECORDDRAWING IS A RECORD OF ALL CHANGES THAT OCCURRED IN THE FIELD AND THAT ARE DOCUMENTED THROUGHCHANGE ORDERS, ADDENDA, OR CONTRACTOR/CONSULTANT DRAWING MARKUPS.TYPICAL CURB AND GUTTERTYPICAL PLANTING AREALINEAR ROOT BARRIER MATERIAL. SEEPLANTING NOTES FOR TYPE ANDMANUFACTURER. INSTALL PERMANUFACTURER'S SPECIFICATIONS.TREE CANOPYTREE TRUNKTYPICAL WALKWAY OR PAVING1234561423565'5'5'5'OPEN LANDSCAPETO 10'PARKWAYOR ISLANDNOTES:1) INSTALL ROOT BARRIERS NEAR ALLNEWLY-PLANTED TREES THAT ARE LOCATEDWITHIN FIVE (5) FEET OF PAVING OR CURBS.2) BARRIERS SHALL BE LOCATED IMMEDIATELYADJACENT TO HARDSCAPE. UNDER NOCIRCUMSTANCES SHALL THE CONTRACTORUSE ROOT BARRIERS OF A TYPE THATCOMPLETELY ENCIRCLE THE ROOTBALL.PLANTING
DETAILS &
SPECIFICATIONSLP-2DATENo.REVISION BYDATE:SHEETFile No. 2022-19406-07-2023CHECKED:EMS/RMDRAWN:EMSDESIGN:EMSKROGER 448
950 E. SANDY LAKERD.
COPPELL, TX TEXAS REGISTRATION #141991903 CENTRAL DR. SUITE #406 PHONE: 817.281.0572
BEDFORD, TX 76021 WWW.CLAYMOOREENG.COM.HIHI
C
SSTE
R
CCTTES
A
E
ETSTAIREG
73OF53ETX ERLDR
E
CAANDSMEPAPLEY(800) 680-663015455 Dallas Pkwy., Ste 600Addison, TX 75001www.EvergreenDesignGroup.comEVERGREEND E S I G N G R O U P08-09-2023