Loading...
Site PlanE E F OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEPROPOSED BUILDING 1 (176,606 SF) PROPOSED BUILDING 2 (139,318 SF) LOT 3AR, BLOCK 2 LOTS 1R-2 & 3AR, BLOCK 2 GATEWAY BUSINESS PARK INST. NO. 201700235650 PART OF 16.51 ACRES HAVERTY FURNITURE COMPANIES, INC. VOL. 2001085, PG. 8033 0.3858 ACRES HAVERTY FURNITURE COMPANIES, INC. VOL. 2001085, PG. 8039 LOT 3C, BLOCK 2 GATEWAY BUSINESS PARK VOL. 2001083 PG. 19 LOTS 3A, 3B, 3C, AND COMMON AREA 1,BLOCK 2, GATEWAY BUSINESS PARKVOL. 2001083 PG. 19REMAINDER OF 16.51 ACRES, HAVERTY FURNATURECOMPANIES, INC., VOL 2001085, PG. 8033LOT 1R-2, BLOCK 2LOTS 1R-2 & 3AR, BLOCK 2GATEWAY BUSINESS PARKINST. NO. 201700235650HAVERTY FURNITURE COMPANIES, INC.INST. NO. 20080334484FR 750 GATEWAY, LLC INST. NO. 201500293509 ST. LOUIS & SOUTHWES T E R N R A I L R O A D (100' R.O.W., VOL 95, P G . 5 1 8 ) ZONING: LIZONING: LI15' TEXAS UTILITIES ELECTRIC EASEMENT VOL. 90138, PG. 4289 (POLES SHALL BE CENTERED 1.0' SOUTH OF PROPERTY LINE & SHALL HAVE SHORT ARMS) 10' T.P.&L. EASEMENT AND GENERAL TELEPHONE COMPANY OF THE SOUTHWEST EASEMENT VOL. 78088, PG. 638 PRIVATE ACCESS & UTILITY EASEMENT VOL. 2001083, PG. 19 20' DRAINAGE AND UTILITY EASEMENT VOL. 96167, PG. 7179 TO BE ABANDONED 20' DRAINAGE AND UTILITY EASEMENT VOL. 96167, PG. 7179 PRIVATE ACCESS & UTILITY EASEMENT VOL. 2001085, PG. 8057 20' WATER EASEMENT INST. NO. 20080120800 15' ONCOR ELECTRIC EASEMENT INST. NO. 20080120800 APPROXIMATE LOCATION OF TEMPORARY DRAINAGE EASEMENT VOL. 96167, PG. 7179 TO BE ABANDONED APPROXIMATE LOCATION OF TEMPORARY DRAINAGE EASEMENT VOL. 96167, PG. 7179 EXCHANGE CIRCLE(60' R.O.W.)FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL F L FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFLFL10' T.P.&L. EASEMENT AND GENERAL TELEPHONE COMPANY OF THE SOUTHWEST VOL. 78114, PG. 576 55.5'5.0'10.0'250.0'200.0'210.0'10.0'5.0'32.0'31.8'24.0' 83.6' 656.9'24.0'62.6'29.2'24.0'9.0'(TYP.)18.0' (TYP.) 24.0' 24.0' FIRE LANE 9.0'(TYP.)18.0' (TYP.)9.0'(TYP.)18.0' (TYP.) 24.0' FIRE LANE 18.0' (TYP.)9.0'(TYP.)24.0'FIRE LANE9.0' (TYP.)18.0'(TYP.)24.0'9.0' (TYP.)18.0'(TYP.)3.0' (TYP.) 9.0' 9.0' (TYP.)9.0'(TYP.)24.0' FIRE LANE 9.0'(TYP.)24.0' FIRE LANE 9.0'(TYP.)18.0' (TYP.) 9.0' (TYP.)18.0'(TYP.)3.0' (TYP.) 17.4'17.4'9.0'(TYP.)9.0'(TYP.)9.0'(TYP.)30' DRAINAGE AND UTILITY EASEMENT VOL. 2001083, PG. 19 20' DRAINAGE EASEMENT VOL. 2001083, PG. 19 PROPSED 5' SIDEWALK 2' SAWCUT LINE. ±85 LF OF EXISTING CURB TO BE REMOVED EXISTING POWER LINE TO BE RELOCATED EAST PROPOSED 20' WATER EASEMENT 10' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER 10' LANDSCAPE BUFFER 24.0'FIRE LANE15.0'5.0'(TYP.)5.0' (TYP.) 5.0' (TYP.) PROPSED 5' SIDEWALK5.0'(TYP.)5.0' (TYP.)5.0' (TYP.) 15' ONCOR EASEMENT BY SEPARATE INST. (INST. NO. ________) R30' R60' R36' R60' 694.0'250.0'648.0'210.0'36.0' FIRE LANE R30' R54' R45' R30' R30' R30' R30' 60' FRONT YARD SETBACK 10' REAR YARD SETBACK 10' SIDE YARD SETBACK 10' SIDE YARD SETBACK PROPSED 5' SIDEWALK PROPSED 5' SIDEWALK PROPSED 5' SIDEWALK PROPSED 5' SIDEWALK3.0'(TYP.)3.0'(TYP.)900 EXCHANGE CIRCLE 950 EXCHANGE CIRCLE OHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEOHEAPPROXIMATE LOCATION OF RELOCATED POWER LINE R30' CONNECT TO EXISTING CURB 24.0'FIRE LANEPROPOSED MONUMENT SIGN S89°40'38"W 881.2'N0°19'10"W777.3'N85°28'50"E 886.8'S0°05'54"E842.2'BM #100 BM #101 BM #102 PROPOSED 10' DRAINAGE EASEMENT WIDENING 20' UNDERGROUND DRAINAGE & UTILITY EASEMENT VOL. 95136, PG. 3876 VOL. 96167, PG. 7179 ANTICIPATED PUMP ROOM LOCATION ANTICIPATED PUMP ROOM LOCATION PROPOSED 15'X15' SCREENED DUMPSTER ENCLOSURE LOCATION CONNECT TO EXISTING CURB FENCE WITHIN PAVEMENT TO BE REMOVED PROPOSED LOADING AREA PROPOSED LOADING AREA PROPOSED LOADING AREA PROPOSED LOADING AREA R180'This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.DATEAS SHOWNREVISIONSNo.DATESHEET NUMBER CHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECTLAST SAVED11/13/2020 1:59 PMPLOTTED BYTAYLOR, ANNAMARIE 11/13/2020 2:01 PMDWG PATHK:\DAL_Civil\67806208 - Brookfield Coppell\4_Design\CAD\PlanSheetsDWG NAMEC-DIMC.dwgGATEWAY BUSINESS PARKTEXASCOPPELLIMAGESXREFS xSite : xBndy : xExSite : xbdr-24x36 : xExUtil : xWater : xEsmtNOVEMBER 2020DPGAETDPGEngineerP.E. No.DateNot for construction or permit purposes.FOR REVIEW ONLY120260DANIEL P. GALLAGHERNOVEMBER 2020© 2020 KIMLEY-HORN AND ASSOCIATES, INC.PHONE: 972-770-1300 FAX: 972-239-3820WWW.KIMLEY-HORN.COM TX F-92813455 NOEL ROAD, TWO GALLERIA OFFICE TOWER,SUITE 700, DALLAS, TX 75240LOT 3A-R2, BLOCK 2GATEWAY BUSINESS PARK ADDITIONWARNING: CONTRACTOR TO VERIFY PRESENCE AND EXACT LOCATION OF ALL UTILITIES PRIOR TO CONSTRUCTION. Know what's below. Call before you dig.PRELIMINARY SITEPLANLEGEND PROPERTY LINE C-101 NORTH 1" = 50' @ 24" X 36" PARKING SUMMARY TABLE BUILDING 1 (176,606 S.F.): PROPOSED OFFICE AREA PROPOSED WAREHOUSE AREA REQUIRED AUTO PARKING SPACES PROPOSED AUTO PARKING SPACES ADA PARKING SPACES PROVIDED BUILDING 2 (139,318 S.F.): PROPOSED OFFICE AREA PROPOSED WAREHOUSE AREA REQUIRED AUTO PARKING SPACES PROPOSED AUTO PARKING SPACES ADA PARKING SPACES PROVIDED 8,830 SF 167,776 SF 198 215 7 6,966 SF 132,352 SF 157 166 6 1.ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION FOR NORTH CENTRAL TEXAS, LATEST EDITION, AND THE CITY OF COPPELL STANDARD CONSTRUCTION DETAILS. 2.DURING THE CONSTRUCTION OF THESE IMPROVEMENTS, ANY INTERPRETATION OF THE STANDARD SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION FOR NORTH CENTRAL TEXAS, AND ANY MATTER WHICH REQUIRES THE APPROVAL OF THE OWNER, MUST BE APPROVED BY THE DIRECTOR OF ENGINEERING OR HIS DESIGNEE BEFORE ANY CONSTRUCTION INVOLVING THAT DECISION COMMENCES. ASSUMPTIONS ABOUT WHAT THESE DECISIONS MIGHT BE WHICH ARE MADE DURING THE BIDDING PHASE WILL HAVE NO BEARING ON THE DECISION. 3.ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 4.ALL CURBS ARE 6" IN HEIGHT UNLESS OTHERWISE NOTED. 5.NO OUTSIDE STORAGE IS PROPOSED. NOTES 0 GRAPHIC SCALE IN FEET 50 25 50 100 BUILDING 1 PARKING CALCULATIONS SF OFFICE = 8,830 SF ÷ 300 SF PER SPACE = 30 SPACES 167,776 SF WAREHOUSE ÷ 1000 SF PER SPACE = 168 SPACES TOTAL REQUIRED SPACES AT 5% OFFICE = 30 + 168 = 198 SPACES BUILDING 2 PARKING CALCULATIONS SF OFFICE = 6,966 SF ÷ 300 SF PER SPACE = 24 SPACES 132,352 SF WAREHOUSE ÷ 1000 SF PER SPACE = 133 SPACES TOTAL REQUIRED SPACES AT 5% OFFICE = 24 + 133 = 157 SPACES GATEWAY BUSINESS PARK GATEWAY BUSINESS PARK ADDITION LOT 3A-R2, BLOCK 2 ZONED LI, 16.4089 AC ALTA/NSPS LAND TITLE SURVEY LOT 3AR, BLOCK 2 LOTS 1R-2 & 3AR, BLOCK 2, GATEWAY BUSINESS PARK S.A.& M.G. RAILROAD SURVEY ABSTRACT NO. 1439 CITY OF COPPELL DALLAS COUNTY, TEXAS JUNE 2020 SITE DATA TABLE EXISTING ZONING PROPOSED USES OFFICE AREA WAREHOUSE AREA TOTAL BUILDING AREA BUILDING HEIGHT PROPOSED LOT COVERAGE FLOOR AREA RATIO IMPERMEABLE AREA LIGHT INDUSTRIAL OFFICE, WAREHOUSE 15,796 SF 300,128 SF 315,924 SF 36' 44.5% 0.445 ± 13.7 AC OWNER BSREP III EXCHANGE CIRCLE, LLC 1180 PEACHTREE ST NE, SUITE 3380, ATLANTA, GA 30309 (212) 417-7000 HEATHER.PECHTER@BROOKFIELDPROPERTIES.COM APPLICANT KIMLEY-HORN AND ASSOCIATES, INC. 13455 NOEL RD, TWO GALLERIA TOWERS, SUITE 700, DALLAS, TX 75240 (972) 770-1300 DAN.GALLAGHER@KIMLEY-HORN.COM BM #100: MAG NAIL WITH SHIRE STAMPED “YP CONTROL POINT” SET ON TOP O F A CONCRETE CURB OF A MEDIAN NOSE ON THE EAST SIDE OF EXCHANGE CIRCLE LOCATED APPROXIMATELY 420 FEET NORTH OF THE CENTERLINE OF GATEWAY BOULEVARD. ELEV. = 523.24 BM #101: MAG NAIL WITH SHIRE STAMPED “YP CONTROL POINT” SET ON A CONCRETE CURB LOCATED APPROXIMATELY 890 FEET EAST OF THE CENTERLINE OF EXCHANGE CIRCLE AND 350 FEET NORTH OF GATEWAY BOULEVARD. ELEV. = 519.63 BM #102: MAG NAIL WITH SHIRE STAMPED “YP CONTROL POINT” SET ON A CONCRETE CURB LOCATED APPROXIMATELY 850 FEET NORTH OF THE CENTERLINE OF GATEWAY BOULEVARD AND 420 FEET WEST OF THE CENTERLINE OF FREEPORT PARKWAY. ELEV. = 520.23 BENCHMARKS FL FIRE LANE FIRE HYDRANT