Loading...
Sheraton DRC CommentsPD20-06-000435Plan Case ID CITY OF COPPELL DRC REPORT Project Name , Lot 3, BkCOMMENTS 311 NORTHWESTERN DRAddress Case Manager 06/18/2020Application Complete Date Planned Development - Detail PD - New/Not In ConformancePlan Type/Workclass Sheraton Four Points HotelProject Description Agency Reviewed By Review Date Plan Review Details Building Suzanne Arnold 06/25/2020 No comments at this time Engineering Cole Baker 06/25/2020 Landscape Plan: - Show storm drain Utility Plan: - Domestic water service cannot come from the fire line. Seperate connection required - DDCV vaults in easement adjacent to ROW are required for fire line - Show domestic and irrigation water meters in an easement adjacent to ROW - Show fire department connection - Provide verification of adequate downstream storm drain capacity - Detailed engineering review to take place during engineering permit submittal Site Plan: - Show firelane radius, make curve have constant curvature like the other side of the driveway - Include total impervious area in Site Data Table General - N/A - UNRESOLVED General - N/A - UNRESOLVED General - N/A - UNRESOLVED Engineering Kumar Gali Fire Tim Oates 06/23/2020 1. What is the name of the road? Northwest or Northwestern? 2. Need to assign address numbers to all 4 buildings on concept plan. 3. Utility Plan: Based on size of the building, additional fire hydrants are required. 4. Utility Plan: Fire hydrants are required to be located every 300 ft along the fire lane easement. 5. Utility Plan: Show Fire Department Connection (FDC) - required to be adjacent to a fire hydrant. 6. Show fire hydrants and FDC on the site plan. Parks John Elias 1. Tree Removal Permit required prior to start of construction. 2. Tree Survey sheet L-1 has incorrect information: -remove all unprotected trees from the tree survey (101,102,105,106,108,111,112,113,114,128,129,132 & 133) -please confirm that tree #131 is 24"DBH, if it is indeed 24"DBH it will be designated a Speciman Tree. -Reparation will be made in the amount of $100 per one inch DBH for trees less than 12 inches DBH and $200 per one inch DBH for trees 12 inches DBH and greater. For Speciman Trees, reparation will be made for the appraised value of the 1 of 4 PD20-06-000435Plan Case ID CITY OF COPPELL DRC REPORT Project Name , Lot 3, BkCOMMENTS removed tree as determined by CLTA guidelines (typical average is about $1,000 per one inch DBH ). -Landscape Credit: 91.5" (61 x 3" = 183" x .5 = 91.5 credit) -You are removing 123", minus Landscape Credit: 91.5", mitigation required on 31.5"DBH. Planning Mary Paron-Boswell General - •Provide original concept plan also for comparison - UNRESOLVED General - - What do the letters in the windows represent - Provide a sign plan - provide colored elevations - identify canopies/awings and material - elevations should be north/south/east/west in addition to front/back/right/left - provide percentages of building materials per elevation - label height of each side - Label features of building ie: front entrance - UNRESOLVED General - Landscaping plans L-1 • Review the tree mitigation and preservation requirements and revise • Review the 24” mesquite L-2 • Revise landscaping buffer calculations per yard comments on site plan L-3 • Revise landscaping buffer calculations per yard comments on site plan • Stamped /hardscape is not included for lots under 2 acres. - UNRESOLVED General - - What do the letters in the windows represent - Provide a sign plan - provide colored elevations - identify canopies/awings and material - elevations should be north/south/east/west in addition to front/back/right/left - provide percentages of building materials per elevation - label height of each side - Label features of building ie: front entrance - UNRESOLVED General - Remove from this submittal. These plans are not being reviewed/approved. future detail site plan and landscape plans will need to comply to ordinance requirements. FYI: •Revise landscaping buffer calculations per yard comments on site plan •Stamped /hardscape is included for lots under 2 acres. - UNRESOLVED General - Provide a legend for A-K - Provide a sign plan - provide colored elevations - identify fencing - elevations should be north/south/east/west in addition to front/back/right/left 2 of 4 PD20-06-000435Plan Case ID CITY OF COPPELL DRC REPORT Project Name , Lot 3, BkCOMMENTS - provide percentages of building materials - label height of each side - Label features of building ie: porte-cochere - UNRESOLVED General - Detail Site Plan • Remove Contour lines from this sheet • Add the following to the Site Data Table: # stories, square footage of entire building, footprint of building, impervious area, floor area ratio • Provide a chart with Hotel requirements Required and provided Hotel Requirements Required Minimums Provided Min. Acreage 2 2.675 Min # Rooms 125 130 All units accessed from interior corridor Yes Yes Parking Min guest room size 285 sf ? Lobby /atrium 750 sf 3200 sf Conference Room 1200 sf 1360 sf Limited or full service restaurant Porte-cochere (2spaces) Must provide 3 additional Amenities Additional Amenities Provided (Y/N) 1 Meeting space (5,000 sf +) 2 Pool (600 sf) 3 Equipped weight room/fitness center (600 sf) 4 Playground 5 Sports Court 6 Jogging Trail (1/4 mile min) 7 Gift/pantry/snack shop (300sf) 8 Outdoor Plaza area (1,000 sf min) 9 Full Service Restaurant (min 35 seats, open to public serving breakfast, lunch and dinner • You are showing 14 parking spaces that are not part of this project or on this lot. Please remove. • Acreage listed in the title block does not match the application • Street is Northwestern Dr. – please correct. • What dimension is your loading area? • Provide owner/ developer contact information on plans • Head to head parking requires 9x19 spaces • Handicap spaces also require a 9ft min width • Show all required drainage and utility easements • Is one dumpster really enough? Provide dumpster detail with elevations • Provide lighting plan for parking lot, provide downward facing lights with shields • Show location of any proposed monument signs • Corner of SH 121 and Northwestern – Art Feature? Label • Minimum 20’ Landscape buffer required in HC • Show your setbacks – Min 60’ from front SH 121 and Northwestern • Rear yard of 20’ • No more than 50% parking allowed in the front yard 3 of 4 PD20-06-000435Plan Case ID CITY OF COPPELL DRC REPORT Project Name , Lot 3, BkCOMMENTS • Parking must be 20ft off of the front property line - label fire lane also as mutual access easement - add note that off-site fire lane/MAE to be constructed with this project List any Variances or PD conditions: - Property must be replatted prior to any permits being granted for construction. - Must construct the off-site mutual access easement/ fire lane with this project or construction on adjacent lot, whichever comes first. - UNRESOLVED General - - What do the letters in the windows represent - Provide a sign plan - provide colored elevations - identify canopies/awings and material - elevations should be north/south/east/west in addition to front/back/right/left - provide percentages of building materials per elevation - label height of each side - Label features of building ie: front entrance - Provide length of building on all elevation sheets - for sign purposes - are there lighted bollards? - label - UNRESOLVED Public Works Michael Garza 4 of 4