Loading...
ADMIN APP 05-21-2020GENERAL NOTES • APPROVED FOR CONSTRUCTION 1. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTORS SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ■ PROPERTY OWNER OR REP. RE 2. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 3. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 4. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 5. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE SUBCONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVAL BY THE CONTRACTOR. CAPACITY SECTOR ADD T—MOBILE SITE NAME ATC/ SPECTRA #309159 T—MOBILE SITE NUMBER DA01078A LAND USE PLANNER NETWORK T-MOBILE BACKHAUL OFTRATIONS CONSTRUCTION MANAGER r o Q �S�c-)'? Q of CD v LO " ¢ I LLI N = X ^ C.� LL.I 1 rn Of o � Of U Ly W < U) U Y C.0 L� LL SHEET INDEXLL 1-1 TITLE SHEET (COVER PAGE) 6 THE MATERIALS OSUCHCASRCOAXAL CABLES AND OTHSHALL LEGALLY AND ER RITEMS LY SREMOVED FROM POSE OF ALL CTHE PEXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. ATC SITE NUMBER 309159 C-1 OVERALL SITE PLAN — FINAL C-1A EQUIPMENT PLAN — BEFORE & FINAL 7. THE SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. 8. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO SITE ADDRESS C-2 ELEVATION & ANTENNA LAYOUT - BEFORE & FINAL C-3 RFDS COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON C-4 REDS PLUMBING DIAGRAM THE DRAWING MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH 3198 N STATE RD C-5 EQUPMENT MODULES SPECS CONSTRUCTION. 9. ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS COPPELL TEXAS 75019 C-6 EQUIPMENT MODULES/RADIO & COVP SPECS AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RE EXPOSURE MONITORS ARE ADVISED TO BE WORK TO ALERT OF ANY DANGEROUS DALLAS COUNTY G-1 GROUNDING PLAN ACGI NO: 18-4801 EXPOSURE LEVELS. Planning Admin Approval City of Coppell OrJ�2��2O2U mparon-boswell DRAWN BY: JC/OF/OA DRIVING DIRECTIONS: DEPART 7668 WARREN PKWY, FRISCO, TX 75034 ON WARREN PKWY (WEST)TURN LEFT (SOUTH) ONTO DALLAS PKWY TURN RIGHT (WEST) ONTO RAMP ROAD NAME CHANGES TO TX-121KEEP LEFT ONTO RAMP -TOLL ROAD* MERGE ONTO SR-121 [SR-121 TOLL] TURN LEFT (SOUTH) ONTO N DENTON TAP RD. TURN RIGHT (WEST) ONTO W PARKWAY BLVD. TURN LEFT BUILDING CODES - INTERNATIONAL BUILDING CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. CHECKED BY: C.ZHANG A 08/01/18 PRELIM CD 0 10/11/18 FINAL CD (SOUTH) ONTO N CORRELL RD. TURN RIGHT (WEST) ONTO W SANDY LAKE RD. TURN LEFT (SOUTH) ONTO OAKBEND DR. AT NEAR CORRELL, RETURN NORTH ON OAKBEND DR. TURN LEFT (WEST) ONTO W SANDY LAKE RD. TURN RITH (NORTH) ONTO LOCAL ROAD(S). ARRIVE 3198 N STATE RD, CORRELL, TX75019. - NATIONAL ELECTRICAL CODE, 2014 EDITION AS ADOPTED BY LOCAL JURISDICTION. - INTERNATIONAL MECHANICAL CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. - INTERNATIONAL ENERGY CONSERVATION CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. L L P R 0 A ENLARGED VICINIT''MAP ° T. 0�lprn.8242m SITE 127 an Hd u _..• •-- •_-• _ Wagon lNheef.Park ='ix: VICIf� Y P �Lit8e — ' Came Easthill - - Park Double ak rn To ,��-• s1 Q e � � 2281 W Qarkvr 1171 e 1 Ave k ` lower Mound ellair Blv , L y, He o 544 EHe6r e t,. Pkw B•_ on. pa.'r- 121y E osemeader 3Dgo r y� � p�n{Frord F 4 Lakesi e o W f a0xt0 - ake T - � -.. ..;... rin Mill ... ,,, ,,, �-" 2999 _! ................ _ id®nt Sa Roeklbdge Park :. J '* toliton A Pei �--- rSpring !30 121 ag J * heel �7 W f �� __ Park _,�BeirLl Rd Bert Lin —_ u �Iq ti Rd _� '_ --—-- -- B ch 28 North a 114 Iwo Pkw rap ��k9.• ` ❑ _ r D L A m 0 Viaw Ln Vas Y INA635 ,� a farm rs � Dallas -Fort w Y-g Branch m I Worth gn'(P $ e 121 I `International 97r g0� m �rAirport C�a Ube 3eD �: I W Royal Ln "le r Minters: ml `� PROJECT SUMMARY: CONTRACTORS: SITE TYPE A&E CONTRACTOR EXISTING MONOPOLE ALLPRO CONSULTING GROUP, INC. WITH EXISTING RELATED UNMANNED 9221 LYNDON B. JOHNSON FREEWAY, COMMUNICATION EQUIPMENT SUITE 204 AT BASE OF TOWER DALLAS, TX 75243 CONTACT: CHIYU ZHANG P.E. OFFICE: 972-231-8893 SITE INFORMATION FAX: 866-364-8375 LAT: 32.977053' N LONG:-97.015667' W TOWER ELEV: 500' ENGINEER JURISDICTION: CITY OF CORRELL OCCUPANCY: COLO UNMANNED TOWER ENGINEERING PROFESSIONALS, INC. ZONING: N/A 1250 BENSON ROAD, NE C CONSTRUCTION TYPE: MP/COLD GARNER, N 27529 OFFICE: (405) 348-5460 FAX: (405) 341-6334 APPLICANT WWW.CLSGROUP.COM T-MOBILE DUKE 7668 WARREES CAMPUS N PARKWAY TEXAS ONE CALL FRISCO, TX 75034 CONTRACTOR TO CALL 48 CONTACT: MICHELLE SHERWOOD-SMITH HOURS BEFORE DIGGING! PHONE: 972-464-3926 PHONE: 800-545-6005 EMAIL: MICHELLE.SHERWOOD-SMITHS O INDEPENDENT LOCATORS T-MOBILE.COM TO BE USED ON ALL SITES LANDLORD AMERICAN TOWER CORP 10 PRESIDENTIAL WAY WOBURN, MA 01801 CONTACT: JEN RAEBEL PHONE: 469-400-2358 CONSULTING GROUP, INC. 9221 Lyndon I Johnson Fwy Suite 204all , Dallas, TX 7524343 Phone: 972-231-8893 Fax: 866-364-8375 co www,alatio tr RegisocNgio. _��►.���1 ' S� of rF %1 ; : ': a,1� �' "'........................ "' " 7 f HWU ZHANG ��•••""•281•87•'•"••. -; f s ``"~�� 09/28/18 DA01078A TC/SPECTRA#30915 ATC# 309159 3198 N STATE RD COPPELL, TX 75019 DALLAS COUNTY SHEET TITLE TITLE SHEET SHEET NUMBER T 1 NOTE: SITE LAYOUT IS BASED ON PREVIOUS SITE LAYOUT BY ATC BY REF #309159 DATED 10/23/14 PROVIDED TO ALLPRO CONSUILTING GROUP. INC VIA SITERRA DOWNLOAD ON 7 1 1 . NO INDEPENDENT SITE VISIT WAS PERFORMED BY ALLPRO CONSULTING GROUP, INC, TO VERIFY THE SITE DIMENSIONS OR LAYOUT. IF ANY DISCREPANCY IS NOTICED BETWEEN THE ACTUAL SITE LAYOUT AND THESE DRAWINGS, PLEASE NOTIFY ALLPRO CONSULTING GROUP, INC. FOR A REDESIGN. (1) PER SECTOR Planning Admin Approval City of Coppell 05/21 /2020 mparon-boswell ® e� ® OVERALL SITE PLAN FULL SIZE PLOT: SCALE: 3/8" = 1'-0" HALF SIZE PLOT: SCALE: 3/16" - 1' 0" C NORTH 0 40'-0" (E) T-MOBILE CONC. PAD WITH (E) EQUIPMENT J I- w x (E) UTILITY RACK N x W/PPC UNIT I� x o (E) GATE I �a o Y M c; U Q ti ■ m Q CO W W 2r �. U LL ■ Y cc) LWL ■ o O ■ ■ ■ A& AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI N0: 18-4801 DRAWN BY: JC/OF/OA CHECKED BY: C.ZHANG A 08/01/18 PRELIM CD 0 10/11/18 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 www.allprocgi.com Registration No. 8242 DA01078A TC/SPECTRA #30915 ATC# 309159 3198 N STATE RD COPPELL, TX 75019 DALLAS COUNTY SHEET TITLE OVERALL SITE PLAN SHEET NUMBER C-1 RELOCATE (1) COVP (E) (12) 7/8"0 COAX CABLE (6) IN USE REMOVE (E) (1) 1.24" LOW CAP HCS HYBRID CABLE REMOVE (E) (1) 1.24" LOW CAP HCS HYBRID CABLE REMOVE (E) (1) COVP 2 -0" 2'-6" 3'-3" 2'-3" ---1 REMVVE (E) a i i� FCOA .. 'i.�/°. •'�:. a . Kjb1 ,`/y J s n�nhi l l I <o I (F) N FCOA i -V (E) DELTA SSC /.4. 2'-0" 3 0" 5' 0" (E) UTILITY RACK W/PPC UNIT in ICE BRIDGE RELOCATED (E) COVP M L(1) RACK AMOB (N) POWER LINE FROM (E) DELTA SSC TO NEW AMOB (N) FIBER LINE FROM (E) DELTA SSC TO NEW AMOB (N) (1) 1.58" HIGH v CAP HCS HYBRID CABLE (E) (12) 7/8"4 COAX CABLE (6) IN USE � o N Planning Admin Approval City of Coppell 05/21 /2020 mparon-boswell 2'-0" 1 r 2 2° 2'-0" 3'-0° e� EQUIPMENT PLANT - BEFORE _� EQUIPMENT PLAN - AFTER 2 FULL SIZE PLOT: SCALE: 3/4" = 1'-O" FULL SIZE PLOT: SCALE: 3/4" = 1'-0" ® HALF SIZE PLOT: SCALE: 3/8" = 1'-0" C — HALF SIZE PLOT: SCALE: 3/8" = 1'-0" C J-1 NORTH 0 66„ NORTH 0 5'-0" (E) UTILITY RACK W/PPC UNIT � O �Q o < Y M a • U Q c)'X W Z x cv ti 0 of O rn m Q E LLI Lu � E U LL- L.L Y ab CO LL- O A& AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 18-4801 DRAWN BY: JC/OF/OA CHECKED BY: C.ZHANG A 08/01/18 PRELIM CD 0 10/11/18 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax 866-364-8375 www.allprocgi. com Registration No. 8242 DA01078A TC/SPECTRA #30915 ATC# 309159 3198 N STATE RD COPPELL, TX 75019 DALLAS COUNTY SHEET TITLE EQUIPMENT PLAN — BEFORE & AFTER SHEET NUMBER C-1A NOTE: TOWER STRUCTURAL ANALYSIS IS BY TOWER ENGINEERING PROFFIONALS. REFER TO ENGINEERING # OAA736544_C3_01, DATED JULY 16, 2018 (E) (3) FRBGs DELTA SECTOR (N) (6) T-MOBILE PANEL ANTENNAS (3) AAFIA (1) PER SECTOR (3) FFHH-65C-R3 (1) PER SECTOR SECTOR A, 0' @ 110' RAD CENTER SECTOR B, 120' @ 110' RAD CENTER SECTOR C, 240' @ 110' RAD CENTER (E) (3) TWIN STYLE 3C-TMAT19211378-21A (1) PER SECTOR (E) (6) AWS/PCS-ECC1920-VPUB (2) PER SECTOR (E) 120' MONOPOLE (E) (12) 7/8"0 COAX (6) IN USE (N) (1) 1.58"0 HIGH CAP HYBRID CABLE (E) ICE BRIDGE (E) CHAINLINK FENCE & BARBED WIRE (E) ANTENNAS BY OHTERS @ 120' (E) CLEARWIRE MW DISH @ 116' (E) ANTENNAS PANEL ANTENNAS BY OTHERS@ 107' (E) 2' HP DISH @ 98' (E) UTILITY RACK W/ PPC UNIT (E) DELTA 400AMP SITE SUPPORT CABINET (SSC) I— (E) TIME WARNER CABINET (E) FCOA (N)AMOB )EL SHELTER /NEXTEL SH ELEVATION FULL SIZE PLOT: SCALE: 1/8" = 1'-0" HALF SIZE PLOT: SCALE: 1/16" = 1'-0" PI 0 2' 4' 8' 16' NORTH REMVOE (E) (2) FRIJs (1) PER ALPHA & DELTA SECTORS rn G o o� rn 0 rn � rn o J ` Q ^7 =0 2O 4 Zy Wes\ O JQ Q �� Q wow Aoo 'I- gs ANTENNA LAYOUT - BEFORE FULL SIZE PLOT: SCALE: 3/8" = 1'-0" HALF SIZE PLOT: SCALE: 3/16" = 1'-0" 0 1' 2' 4' NORTH (E) (3) FRBG (1) PER SECTOR (E) (3) TWIN STYLE 3C-TMAT1921B78-21A (1) PER SECTOR GP��,P �l,OOp,L o ANTENNA LAYOUT - FINAL FULL SIZE PLOT: SCALE: 3/8" = 1'-0" HALF SIZE PLOT: SCALE: 3/16" = 1'-0" 0 1' 2' 4' REMOVE ?p• -" 2j0p (E) (1) CO VP ""00 p79p (E) (6) AWS/PCS-ECC1920-VPUB (2) PER SECTOR REMOVE (E) (2) FRIGs (1) PER BETA & GAMMA NOTE: MOUNT COMPLIANCE ANALYSIS IS BY OTHERS NO NEW EQUIP OR ANTENNAS SHALL BE INSTALLED WITHOUT THE APPROVAL OF A STRUCTURAL ENGINEER NOTE: PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELD VERIFIED BY GENERAL CONTRACTOR PRIOR TO CONSTRUCTION TO AVOID ANY INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS. IF INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS IS DISCOVERED DURING FIELD VERIFICATION, PLEASE CONTACT ALLPRO CONSULTING GROUP INC. FOR DESIGN REVISION PRIOR TO ANY NEW ANTENNA INSTALLATION. NOTES: 1. MOUNT COMPLIANCE BY OTHERS 2. VERIFY AZIMUTHS WITH REDS 3, 2' ANTENNA SEPARATION REQUIRED. 4. CONTRACTOR TO MOVE (E) ANTENNAS TO ENDS OF PLATFORM AS REQUIRED, WHEN APPLICABLE. Planning Admin Approval City of Coppell 05/21 /2020 mparon-boswell (E) MONOPOLE (E) (1) TOP COVP BOX (N) (6) TMO ANTENNAS (2) PER SECTOR EXISTING MOUNT (E) (3) FRBGs (1) PER ALPHA, BETA, & GAMMA SECTORS (E) (3) TWIN STYLE 3C-TMAT19211378-21A (1) PER SECTOR (E) (6) (E) (1) COVE AWS/PCS-ECC1920-VPUB (E) PLATFORM (2) PER SECTOR MOUNT, O I — N �lq "4 U?Z00 ((1 ) COAX Z 716SC 0j900 (6) IN USE STRANDEDCOPPER NEW INSULATED GROUND WIRE MpOFl o TO SECTOR AGB 0 q (TYP. 0 EACH SECTOR) 4, ����q?700 , ql \ � 900 (N) (2) T-MOBILE PANEL ANTENNAS (N) (1) 1.58" HIGH CAP 0' o o .0 MODELN HBXX-3319D5-A2M HYBRID CABLE (1) PER ALPHA & DELTA SECTORS (E) (6) AWS/PCS-ECC1920-VPUB (E) UPPER ANTENNA (N) (2) T-MOBILE PANEL ANTENNAS MODELq RVV-338-R3 (2) PER SECTOR GROUND BAR 1 PER ALPHA & DELTA SECTORS ANTENNA/RRU MOUNT DIAGRAM 4 FULL SIZE PLOT: SCALE: 3/4" = 1'-0" HALF SIZE PLOT: SCALE: 3/8" = 1'-0" 0 6" 1' 2' Ocf) Q O cL 1 CJ M ■ C( X w z ■ 6 of O m¢co Ei2 Y00 � LL LL. O ■ A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 18-4801 DRAWN BY: JC/OF/OA CHECKED BY: C.ZHANG A 08/01/18 PRELIM CD 0 10/11/18 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 ww AIProc9i.com Registration No. 8242 09/28/18 DA01078A TC/SPECTRA #30915 ATC# 309159 3198 N STATE RD COPPELL, TX 75019 DALLAS COUNTY SHEET TITLE ELEVATION & ANTENNA LAYOUT - BEFORE & AFTFR SHEET NUMBER C2 Section 1 - Site Information 5He Io: DA01078A Site Rams: ATCISpectra #309159 Latitude: 32.97711844 Stows: Draft SilnGass: Monopole Longitude:-97.0156BB90 veralen: 111 sllaTyps: Structure Non Building Address: 730 E. Sandy Lake Pro]ecerype: Capacily-Sector-Add ssludonTyps: City,Statr. Coppell. TX Approved: NOl Approved Planyow: Region: SOUTH Approved By: Not Approved Merkel: DALLAS TX Last modMod: 4251201811:40:10 AM Vendor: Nokia Ln1 modlAsd By: GSM19WENduret Landlord: American Tower RANTempletc 67718_R41 ALT-0": 6771BWR4 Sector Couw 3 AntennaCount: 6 Coax LlnaCounl: 6 TMACounC 3 RRUCounl: 6 Propose e d RAN E q uip m ant Template: 6771 B R4 E•�e••ro 1 2 3 4 EmdossreTyue Ancillary E¢lipment C-7erLericCadnet Tower Top Mount(Gen anc Site Support GYhinet Buebaad FSME 2100 ESME3 ABW(x11 ASIA [xZl 19oO smebwd Sebrack irlAo6 HybridC.ble Sy.11— NSN High Cap HCS'Selact Length' lamCtrDs BOX Large CDVP LBrga COUP Power.ubry.rem (Be mar. '5eled site' area kers 'Select see' CSR 7705'Soled modal' R tiliw Shelf'Seleet sine' Radio F)LFR FRLA(x]] 1 00 1c0 FRBG(A-11 A] L700 L� 11 L1900 RAH Scope of Wort• NOTE: 1-700, GSM and U2100to use new Octo antenna FFHH-66C-R3. L21 WL19DOtouso newAAFIA antenna Sector 1 (Pro posed) viawfrom fir ont(Note:the images show Aovirfrom behind) Coverage Type A- Outdoor Macro Anti 1 2 AmensaModel [AA FIA(Active Antenna • Massive MIMO] Commseapa- FFHH-65(—R3 (Oita) Azlmwth M.Tilt D 0 Haigba 110 110 Pert. P 1 P2 P3 P4 P5 AzdwTezh. L2100 L7900 LF00 U2100 G1900 Darkrmh. Resnktrd Tech. Deoomm Teo h- E.Tia Cables Generic Feeder Ccax Da) 7MA9 CarrInhSCOpe Twin We 3C - TMAT 1921 B 7E3 21A (El5ZO1 P33) (AtAntenna) Dipboeln I cape Combiners C5 - 26 t(AXtC n Bt) (rd) Sector 2 (Proposed) view from front (Note: the images *haw view fir am behind) Cowrapm Type A -Outdoor Macro A.re... 1 2 Amlesna Model AAFIA five Ant anna-Mas sdva MIME (Active )j Colnrns cope- FFHF+65GR3(Ckta) A2imNtk 120 120 M.Tit 0 0 Neill 110 110 ports P1 P2 P3 P4 P5 Actlw Tech. L2100 L1900 L700 U2100 G1900 D.rk Tech. Restricted Teck, Deco mn Tech. E.Tilt Cabks Generic Feeder �htl ThtA. CammS Dope Twin Style 3C - TMAT 1921 B78- 21A (E152)1P33] (AtAntennai VIPI ersl C, mrrSulpa Combiner= AYVWCS - ECC192D- VPV B (AtOahinet) 14) Sector 3 (Proposed) via avfrom front (Note:the imagos show viewfrom behind) 0---g.Type A- Outdoor Macro Aetema 1 2 Astema Model AAFLA (Active Antenna- Massive MIIu10) Commscope- F--- HH-65C-R3 (Octa) Azimuth 1.1.Tik G Height 110 110 Ports 121 P2 1`3 P4 P5 Active Tech. (�1 OD L1900 L700 I12100 G1900 DwkTmk. Restricted Tech. Decomrn.Tech. E.Tit Cahkx Generic Feeder Coax (aZI ThlAs — amm5cape in styde 3c - rT T1921 B78. 21A (E15Z01P33) . (AtAntenna) D41eXer:I CorLlm5co�e Cash locus AW51pC5 - ECC192I1 [kCalineq fide'] OU O Q Y M cLO h I<, QL� X W Z � car o of C LU3:ELD w oo � V ILL Y (0 � o 20 O A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 18-4801 DRAWN BY: JC/OF/OA CHECKED BY: C.ZHANG A 08/01/18 PRELIM CD 0 10/11/18 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 ww Alprocgi.com Registration No. 8242 CHk YL1 2HANG J28187 . 09/28/18 DA01078A TC/SPECTRA #30915 ATC# 309159 3198 N STATE RD CORRELL, TX 75019 DALLAS COUNTY SHEET TITLE RFDS SHEET NUMBER C-3 6771 BR4 LTE A'WS-WC9400+7010 UIvTS AWS+G5M PC 1'—�nlv Alpha Se pa shown here] jo I j%k6 r 1% AHLOA ;60Off00Mhz Dual Band) • r� O w Q CD LO CD U Q ti ■ o w d a ■ m Q C_n W W � � U LL ■ Y cc) ■ o ti O ■ ■ ■ A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, 101801 ACGI NO: 18-4801 DRAWN BY: JC/OF/OA CHECKED BY: C.ZHANG A 08/01/18 PRELIM CD 0 10/11/18 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax 866-364-8375 www.allprocgi.com Registration No. 8242 CHI Y11 2HANG j28187. 09/28/18 DA01078A TC/SPECTRA #30915 ATC# 309159 3198 N STATE RD COPPELL, TX 75019 DALLAS COUNTY SHEET TITLE RFDS PLUMBING DIAGRAM SHEET NUMBER C-4 ■ AirScale Subrack AM0B Overview The AP�kOB is an outdoor enclosure ?:��, designed :o house Ai rSca le System Module Indoor (ASMI) plug-in unit f EPIU)va'ians. P • The AP�kOB has a thermal managementsystem using a heat exchanger (HEX) to maintain proper temperature for the indoor -rated HEX PI[J Enclosure F rant View (doer removed) Ail -Scale Subrack Outdoor AMQB datasheet �a o Y M ch Q � O � a Cq LU o Lu o m a w w 2i U ■ Y rp LL_ � = to p o „ ■ ■ ■ ■ €nvir3r-nental protection IP55 ��sulssn n+r! Featiwede5crlptlon: vdlder,lhom(0p e1 4B7nm � Outdo Dr Su6rxtfnr AlS[21e Sy Stem NIXhle lMddr Qhlg.-nurtit5 Zh laGnall A 48mm[Ges in to 19 inh rack) High perry *r once Heat Exd arger'HEK" A 87 mee (ri aw conduit ply or 6m ine5l CornpatiblewthFl Iirecharicsstack 10ntVwall/pole/rackkistallatron aeain TntaE6llAMIDge7Lmmfmmraknovn[ugvpfacal WNghes 23 kg Ar40B rnrlpwrc ces IV ASA(com Modals) Corriil lhle with the 3rd Fart 19'racks and caUrlets it it l Blows clear an3 andalrNo'Nret>}Ilren'terlis 2 kg ABTA K-Pm Pan MINVO 3 i' 1 5i C 0 Paelty H Cars • 5 rpan1100 b,kg Ful0paotyQCofe•'jEvaroiunl etarsonfr ntaOS nsieade r'COAtahrtet I•�s�F.•r-r.r Fss Servi�edvorsmfro rtandrears+des ServPomice Opandng tempera:vre -46'C up to [wiNoul sa lac raAa[Ionl ASMI AMC •The AMOB has features that allow it to be mounted in various ways, includingattachment to a wall or pfile, as art of a standard Flexi p module staek, and inside of cabinets such as the FCCA. ABIAAirSCale Caalit Module (1-6 pa Y } ASIAAirScaIeCommortIold uIe(1-2) 2 © Nokic 2016 _ �� �ll,lC��lll NC]KIA HE7CAtEB rnnhl-aA PpIJ and Hegler[-1U1 ASIA+ABL4[aU} 8U aI� =� � Corti 3 0Nokia 2016 Corti Insttill Terri er t t ur e wrXpwDirecapn Clearances Car molrng Colo ��:�rt rro .nalsup, rr•:�naee Inp�:v�ltage •and v�m ue Hasscspe6ay F�re-crs gCor. Conduit rabieemry -2c•C--55'C 8xk � 4vntanfla�udirrcapn wopwted for itorreonalr[OFl. g'r. I FI... Front to b", aldfl� d"ecton snppw ted Fa r vrr dcacl"ll and rn - 40 nm Minmwnl on the back and Front sde -dl• Ne-..4c•[ m s•c 'optor,01^ heatertanbeaddedtamee[riAo-lreav,ren,Em,<ohlstartiom-40•C o -5 C ins ^ournc aadoF2 r-Lou s nas....s7vDc F�ndedSmirr'lokage Rarge supported S6V�. •40L'd<Fbta[ing 104.5L Supp°r.MulBKyinsde Tp7v4—ax-265A1aIfa.sa'1­0gFesEs..4 CaIds: q-soaw$e�te-onsw-Frnsasr,.,aeedl ;x1.5'+Bx 1" on eadi left andridit ode AA AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI N0: 18-4801 DRAWN BY: JC OF OA CHECKED BY: C.ZHANG A08/01/18PRELIMCID 0 10/11/18 FINAL CID CanFdenGal ALLPRO CONSULTING GROUP, INC. AirScale Subrack AMOB 448nm117.6in Overall ❑imensions GD5mm123.8rn 472rnm116.6in 42[kmnI75.51m 290m m111.4in AirScale Subrack AMOB B Mounting Options - Flexi Module Stack • The AMOB can be mounted to a stack of Flexl modules • An additional stacking plinth (and security bracket) is required • No equipment can be mounted above the AMOB • When mounted horizontally, the following clearances must be observed: * _ • 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 116-111-1171 www.allprocgi.com Regislrolion No. 8242 - oFr ►► � ySp��... RrrTsk8I1 .: •P•' - l� ............................. CH4Yu 7HANCi. i r! 28187 1t •. { �_� ►�'�i��_'� c Front 600mm for module installation Rear: 600mm for air flow land maintenance) ° 09/28/18 DA01078A TC/SPECTRA #30915 ATC# 309159 3198 N STATE RD IE--- 487rrsn119.t1n ___ ❑ Right/Left: 300mm for cabling I aL �Rt _ ' "m° d3 yw! P 44 mm :�. �: a rPp a, _ ' 354mm173.9in - 181 Ij` Stacking Plinth 0 LP • c f D a g k lsi i e7 I "��g--_,__•_ ___.- - - -•-' C5019 DALLAS COUNTY SHEET TITLE EQUIPMENT MODULES SPECS 5 Sr"a2016 C� fdderniai NOKIA 10 Cor6denti2! SHEET NUMBER C-5 AirScale Subrack AMOB PDU Power Distribution Unit • The PDIJ provides-48VDC power distribution and control for the sub rack • The main power input is via a 2-pole Anderson connector rated for 50A • The components (housing and Contacts) for the mating connector are provided with the AMOB for field crimping to I input wring DC Input Connector 16 © Nokia 2016 Confidential G err . ar art � AirScale Dual RRH 4T4R B12/71 240V M6 d a our .a. .errwr a - t I 3 f 7 HEX DC Input toASMI o n V) to Harness Hi p� 4 t NOKIA r AHLOA l ❑ �PA�LF Supported Frequency bands 313PP Band 1 2171 Frequencies Band12 adjusted UL692-716MHz.01723-746MHz Band 7T UL-663 MHz - 698 MHz, DL. 617 MW- 652 MHz Number of TXIRX paths/pipes 4 pipes, 2T2A, 2T4R, 4T4R for bath Lands Instantaneous Bandwidth I8W 17 MHz for 812 and 35MHzfod B71 i MHz below B12 NS 167 future use 0ccupled Bandwidth 03W OIL 53MHrcoatigueus DL B12 1 7MHz+ 1 MHz NB IDT Future use. B71 35MHz Output Power 60W per TX shared between hands Supply Voltage 1 Range DC-48 V 1-36 V to -60 V Typical PowerCtmsumption 640W [E751 Busy Hour Load at 4TX@601N 45OW [Er51 Busy Hour Load aL 4TX@26W Antenna Ports 4 ports, d 3-30+ Optical Ports 2 x CPRI 913 Gbps ALD Control Interfaces AlSG3 band RET (DCon ANT & ANT31 Other Interfaces External Alarm MOR-25 (4 inputs, 1 Output) DC Circular Power Connector Physical 560 mm x 30B mrr x 189 mm Approximately 33kg with no covers or bracke-s Operating Temperature Range -40°C to 55°C Iwith no solar koa dl Surge Protection Class II SA Installation Options Pole- Wall, Book Mount AirScale Subrack AMOK ASINABiA Interfaces c ASIA 4txfacir Label Pn 14W Numberof intarfm" Contactor typo Pv..er cane r DC in 2-pole oll )seminal EmWmal Alp ark EAC 1 Hol Contrd INedl $yrchronizaeon SIN I HDMI Inu4sm {in"I syrchro "ti.. SHUT 1 HOW Inlerraoe raarowl EMMsion ln*ftm Se] 2 MW-SAS HD I Leuncy $R10 2 SFP. "i emom,actbn TP.S INerfece, EIF 5 SFP•and R.165 PrE9Wnat Trmemiwon Interlace Laeal ManagenleN LMP t Rd" Pon prvwGn9 Con+ecrw ONO 1 LI$X12 we» RFi Rl RF-' kF4 RFS RA O .Sr. q cr ❑O O OD exeffaca LGWM HW NulnLerof i~aces C.—; type C OC--�.,„' D QQ Oplcat lntw— RF 5 ar%'• ARIA 17 V Nokia 2616 Confidential NOKIA Inches To ardor gland kth for coax roul NmOlderNutiar RaycapOrderNumhau GfandKII-Install2it eTypo _ ASU9334T_YPLi1 17771-TWR-C_x-STG-KITJ Tower Coax Reuse (St ngero For use with NSN Standard 60 kA COVP-for Tower Coax Stinger sites - Order ONE kit per NSN Standard COVP pair ASU9335TYP01 (7771-TWR-CX-DSC-KIT) Tower Coax Reuse (Discrete) For use with NSN Standard 60 kA COVP-far Tower Coax Discrete 6AWG aites- tab Order ONE kit per NSN Standard COUP padr ASU9336TYPC1 (7771 -8 FTP- CX-STG - KIT) Rooftop Coax Reuse (Singer) For use with NSN Standard 60 kA COVP- Order ONE kit per NSN Standard COVP and 3 Rooftop Sector COVP pair �a o ■ U v W Z N ■ U m ¢ U U Y coLu LPL ■ to 0 ■ ■ ■ A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 18-4801 DRAWN BY: JC/OF/OA CHECKED BY: C.ZHANG A 08/01/18 PRELIM CD 0 10/11/18 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 www.allproagi.,,om Registration No. 8242 CHIYII 2HANlC' 09/28/18 AWG mAnterlcan Wlm Gauge DA01078A u Cps wo r'Mus & [ TC/SPECTRA #30915 ATC# 309159 NODE 5lerrk715 3198 N STATE RD Netvmrks Raycap COPPELL, TX 75019 _ .. DALLAS COUNIY G02-0O-167 120504 SHEET TITLE EQUIPMENT MODULES/RADIO & COVP SPECS KIA SHEET NUMBER Cal F G G G G G G G G G G G G G G v v ICE ° v ° v °.. BRIDGE ° a vo " v ° v ° RELOCATED COVP (N) (1) RACK W/ (N) AMOB a a° v w a. NEW GROUND WIRES v FROM NEW EQUIPMENT TO TIE INTO (E) EQUIPMENT GROUND ° a RING °a° a . a ° ' ° A (E) FCO / a. (E) DELTA SSC v° v / -- a J 9 C 9 9 9 0 9 0 0 0 0 9 9 9 (E) EQUIPMENT GROUND RING GROUNDING PLAN -FINAL „ FULL SIZE PLOT: SCALE: 1" = 1'-0" Cj 1 HALF SIZE PLOT: SCALE: 1/2" = 1'-0" NORTH 0 CAD WELD CONNECTIONS NO. DESCRIPTION MOLD NO. WELD NO. 1 #2 SOLID TO #2 SOLID PTC-1T1T 65 2 #2 SOLID TO GROUND ROD GTC-161T 90 3 #2 SOLID TO FENCE POST VBC BURNDY CONNECTIONS NO. DESCRIPTION PART NO. 4 #6 GREEN STRANDED 2-HOLE COMPRESSION LUG 5 #2 SOLID TO POST KC 6 BRAIDED STRAP BOLTED TO GATE POSTS BD18G92 * CHECK WITH PROJECT MANAGER FOR CONNECTION TYPE IF TABS ARE NOT PRESENT ON MONOPOLE OR TOWER. LEGEND A CADWELD CONNECTION 8' x 5/8" COPPER CLAD GROUND ROD (8' MAX SEPARATION EQUALLY SPACED) ® TEST WELL & GROUND ROD ■ BURNDY CONNECTION #2 AWG TINNED SOLID BARE CU (GROUND RINGS SHALL BE 2'-6" BELOW GRADE) c c (E) GROUND RING x x CHAIN LINK FENCE Planning Admin Approval UTILITY RACK City of Coppell PC UNIT 05/21 /2020 mparon-boswell r� • r� O Q CD LID �YMC? ■ U LE) v CV W ZLU ■ 1� O �■ U DpQfAU a Y CO� ■ oCO O ■ ■ ■ A& AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI N0: 18-4801 DRAWN BY: JC/OF/OA CHECKED BY: C.ZHANG A 08/01/18 PRELIM CD 0 10/11/18 FINAL CD ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 www.allprocgi.com Registration No. 8242 DA01078A TC/SPECTRA #30915 ATC# 309159 3198 N STATE RD COPPELL, TX 75019 DALLAS COUNTY SHEET TITLE GROUNDING PLAN SHEET NUMBER G-1