Loading...
Sprint.DA03XC121.330 S Royal.ADMIN APPROVEDSPRINT SITE CASCADE: SPRINT SITE NAME: SITE TYPE: TOWER HEIGHT: DA03XC I21 COPPELL (S ROYAL LN) MONOPOLE 95.61 SITE INFORMATION CROWN CASTLE SITE NAME: COPPELL (S ROYAL LN) SITE ADDRESS: 160 SOUTH ROYAL LANE COPPELL, TX 75019 COUNTY: DALLAS AREA OF CONSTRUCTION: EXISTING LATITUDE: 32° 58' 10.36" LONGITUDE: -97' 1' 22.25" LAT/LONG TYPE: NAD83 JURISDICTION: CITY OF COPPELL, TX OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: VB A.D.A COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION CARRIER/APPLICANT: SPRINT 1300 E ROCHELLE BLVD IRVING, TX 75234 CROWN CASTLE 476674 APPLICATION ID: ELECTRIC PROVIDER: ONCOR TELCO PROVIDER: AT&T PPC)I rT T1~ ANJ DESIGNER FIRM: BROADUS SERVICES 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS,76013 PH: (817) 349-3449 ENGINEER: JACOB GORALSKI, PLLC 1106 COLBI STREET KENNEDALE,TX 76060 CONTACT: JACOB GORALSKI PH: (817) 456-2621 CROWN CASTLE CONTACT: 6161 N STATE HWY 161 SUITE 200 IRVING, TEXAS 75038 PAUL THOMAS - A&E SPECIALIST PAUL.THOMAS.CONTRACTOR@CROWNCASTLE.COM PH: (972) 457-9133 THOMAS CZAPIEWSKI - CONSTRUCTION MANAGER THOMAS.CZAPI EWSKI@CROWNCASTLE.COM PH: (509) 496-1322 KELLI WALSH -A&E PROJECT MANAGER KELLI.WALSH.CONTRACTOR@CROWNCASTLE.COM PH: (512) 652-2110 SPRINT CONTACT: SHERRY BUIRL Sprint CROWN CASTLE BU #: 839836 APPLICATION ID #: SITE ADDRESS: COUNTY: SPRINT MICROWAVE ANTENNA PROJECT JURISDICTION: LOCATION MAP Grapevine 0 Andrew ,eational Area Brown 5 Park West Coppell High School 0 w smd� W Sandy law: Re LEGOLAND Discovery 5 _ Center Dallas/Fort Worth - SITE I R GD 8, Arnndl Bowling a &Amusement a¢a O Grape ne Ca pusrch Core Park ON Grapevine Campus Nature Park 4� s' Hilto'r D1111 O © S t nkes Executive.. a. � _ S Amazon DFW6P of Bass Pro Shops '5 Bess Pro D, W Be,FN RA W Bethel Rd .y Hard IPRO Copp�'�I wmm�el ue C DRIVING DIRECTIONS FROM LOCAL SPRINT OFFICE ON 1300 E ROCHELLE BLVD, IRVING TX 75234, GET ON TX-114 W FROM ROCHELLE BLVD. CONTINUE ON TX-114 W TO GRAPEVINE. TAKE THE EXIT TOWARD BASS PRO DR FROM TX-121 N. CONTINUE ON FRONTAGE RD TO YOUR DESTINATION AT 160 SOUTH ROYAL LANE COPPELL, TX 745019. APPLICABLE CODES/REFERENCE DOCUMENTS — INTERNATIONAL BUILDING CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. — NATIONAL ELECTRICAL CODE, 2014 EDITION AS ADOPTED BY LOCAL JURISDICTION. — INTERNATIONAL MECHANICAL CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. — INTERNATIONAL ENERGY CONSERVATION CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. UNDERGROUND SERVICE ALERT CALL TOLL FREE 1-800-245-4545 TWO WORKING DAYS BEFORE YOU DIG 476674 160 SOUTH ROYAL LANE COPPELL, TX 75019 DALLAS CITY OF COPPELL, TX PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO ENHANCE BROADBAND CONNECTIVITY AND CAPACITY TO THE EXISTING ELIGIBLE WIRELESS FACILITY. • INSTALL (2) MW DISH RFS/CELWAVE / SC2-220BB • INSTALL (4) CERAGON / FIBEAIR IP-20C • INSTALL (4) BELKIN / CAT5E (1/4") CABLES IN 1" CONDUIT • REMOVE (1) ANT2 0.3 23 HPX (TR) • REMOVE (1) ANT2 0.611 HP (TR) • REMOVE (1) MLTN11 • REMOVE (2) MLTN23 • REMOVE (3) LDF2-50 DESIGN PACKAGE BASED ID:476674 Planning Admin Approval City of Coppell 01/31/2020 mparon-boswell THE PARTIES ABOVE HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE. DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET C-1 SITE PLAN & ELEVATION C-2 ANTENNA LAYOUPMOUNT & MW SPECIFICATIONS G-1 GROUNDING DETAILS ALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 11X17 SIZE. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. CROWN CASTLE 6191 N STATE HWY 161, STE.200 IRVING, TX 75038 Sprint 1300 E. ROCHELLE BLVD. IRVING, TX 75234 BR0ADUS � services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 19 JACOB GORALSICI 1;687 . .. ears CONSULTING ENGINEER TX PE No. 116673 FIRM No. F-17021 1106 COLBI STREET KENNEDALE, TX 76060 (SM 456-2621 DRAWING NOTICE. THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED. DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. DESCRIPTION DATE BY REV ISSUE FOR CONSTRUCTION 12/17/19 DB4 0 ISSUE FOR REVIEW 05/07/19 DB B ISSUE FOR REVIEW 03/06/19 DB A SITE CASCADE: DA03XC121 SITE ADDRESS: 160 SOUTH ROYAL LANE COPPELL, TX 75019 PROJECT: SPRINT MW PROJECT SHEET DESCRIPTION: TITLE SHEET DWG INFORMATION: SHEET #: T-1 DRAWN BY: DBB CHECKED BY: EPB EXISTING SPRINT H-FRAME X - } EXISTING ACCESS x GATE�I x i I x X EXISTING FEEDLINES (3) ANDREW / LDF2-50 (3/8") (TO BE REMOVED), (3) ANDREW / LDF2-2R (1") & (1) ANDREW / LDF6-50A (1-1/4") INSTALL (4) MICROWAVE CABLES BELKIN / CAT5E (1/4")� -X -X -X - x I x EXISTING ACCESS ,----GATE x1 L EXISTING RBS--,C- CABINET N EXISTING SPRINT L CONCRETE SLAB L X- X- X- X- X X -X -X -X -X -X -X -X -X .� 4'-0" EXISTING METER EXISTING 95.6' ON POLE >, MONOPOLEfl�a EXISTING STEEL PLATFORM io EXISTING BBS CABINET EXISTING EQUIPMENT SHELTER EXISTING PAD x EXISTING EQUIPMENT PAD x ..__ x EXISTING UTILITY POLE X- X- X- X- X- X- X- X- X EXISTING COMPOUND CHAIN LINK FENCE Planning Admin Approval City of Coppell 01 /31 /2020 mparon-boswell SITE PLAN 1/4"=1'-0" STRUCTURE INFORMATION IS SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. STRUCTURAL INTEGRITY OF SUPPORTING STRUCTURE, ANTENNA MOUNTS, AND FOUNDATION SHALL BE VERIFIED AS ACCEPTABLE BY ENGINEER CERTIFIED STRUCTURAL ANALYSIS, UTILIZING THE LOADING REPRESENTED WITHIN THESE DRAWINGS PRIOR TO THE EXECUTION OF EQUIPMENT CHANGES CONTAINED IN THESE DRAWINGS. CONTRACTOR SHALL OBTAIN ALL STRUCTURAL REPORTS AND FOLLOW ALL RECOMMENDATIONS. REFER TO STRUCTURAL ANALYSIS BY PAUL J. FORD AND COMPANY PROJECT# 37518-3142.002.7805 DATED: DECEMBER 28, 2018 EXISTING OTHER CARRIER MW DISH EXISTING (2) MICROWAVE DISH (1) ERICSSON / ANT2 0.6 11 HPX (TR), (1) ERICSSON / ANT2 0.3 23 HPX (TR) WITH EXISTING (3) ODU (2) ERICSSON / MLTN23 & (1) ERICSSON / MLTN11 (ALL TO BE REMOVED) OL EXISTING 2)-SPRINT MW DISH ® ELEVATION 84'-0" AGL NSTALL 2 SPRINT MW DISH @ ELEVATION 80'-0" AGL INSTALL (2) MICROWAVE DISH RFS/CELWAVE / SC2-22OBB & (4) ODUs CERAGON / FIBEAIR IP-2DC EXISTING SPRINT EQUIPMENT A I TOWER ELEVATION OVERALL TOWER HEIGHT 0 ELEVATION 101.6' AGL TOP OF TOWEF. 0 ELEVATION 95.6' AGL EXISTING OTHER CARRIER PLATFORM MOUNT WITH ANTENNAS EXISTING (9) SPRINT PANEL ANTENNAS (6) RFS/CELWAVE / APXVERR18-C (TYP 2 PER SECTOR) & (3) COMMSCOPE / TTTT65AP-1XR (TYP 1 PER SECTOR) EXISTING (3) FILTER'S NOKIA / RADAR FILER (TYP 1 PER SECTOR) EXISTING (12) RRU'S (3) ERICSSON / RRUS 11 (TYP 1 PER SECTOR), (3) NOKIA / FZHJ-RRH (TYP 1 PER SECTOR) & (6) ERICSSON / RRUS 31 B25 (TYP 2 PER SECTOR) EXISTING OTHER CARRIER PLATFORM MOUNT WITH ANTENNAS INSTALL (4) MICROWAVE CABLES BELKIN / CAT5E (1/4") EXISTING FEEDLINES (3) ANDREW / LDF2-50 (3/8") (TO BE REMOVED), (3) ANDREW / LDF2-2R (1") & (1) ANDREW / LDF6-50A (1-1/4") NO SCALE I B CROWN CASTLE 6191 INSTATE HWY 161, STE.200 IRVING, TX 75038 Sprint 1300 E. ROCHELLE BLVD. IRVING, TX 75234 BROADUS� services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 _1 9 JACOB GOR►4LS1C1 � 146873 �r CONSULTING ENGINEER TX PE No. 116673 FIRM No. F-17021 1106 C0L81 STREET KENNEDALE, TX 76060 (SM 456-2621 DRAWING NOTICE. THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED. DISSEMINATED OR REDISTRIBUTED WITHOUTTHE EXPRESS WRITTEN CONSENT OF SPRINT. DESCRIPTION DATE BY REV ISSUE FOR CONSTRUCTION 12/17/19 OBE0 ISSUE FOR REVIEW 05/07/19 DB B ISSUE FOR REVIEW 03/06/19 DB A SITE CASCADE: DA03XC121 SITE ADDRESS: 160 SOUTH ROYAL LANE COPPELL, TX 75019 PROJECT: SPRINT MW PROJECT SHEET DESCRIPTION: SITE PLAN & ELEVATION DWG INFORMATION: SHEET #: - DRAWN BY: DBB CHECKED BY: EPB 1A (AZ 292') INSTALL (2) MICROWAVE DISH RFS/CELWAVE / SC2-22OBB & (4) ODUS CERAGON / FIBEAIR IP-20C 3D (AZ 292') SECTOR 1 C (AZ 0-) (AZ0-) (AZ 0-) EXISTING (12) RRU'S (3) ERICSSON / RRUS 11 (TYP 1 PER SECTOR), (3) NOKIA / FZHJ-RRH (TYP 1 PER SECTOR) & (6) ERICSSON / RRUS 31 B25 (TYP 2 PER SECTOR) �EXISTING (9) SPRINT PANEL ANTENNAS (6) RFS/CELWAVE / APXVERR18-C (TYP 2 PER SECTOR) & 2A (3) COMMSCOPE / TTTT65AP-1XR (AZ 120') (TYP1 PER SECTOR) PRODUCT DATASHEET RADIO FREQUENCY SYSTEMS SC2-220BB The Clear Choic' 1 RFS Compactllnea. and Cotlpsctunw.. Easy U tennas are deelgr»d Tor BhW4131.11 microwave systems In 311 conrnon frequency rar�g�8 from G GFtz to 8G Gltr They are typically deployed In dense urban 3mas, metropolran and subur68(1 Ioe3'7ona. 3gWW30m poln;s. They are especially op•7mtzed to integrated moos t0 reduce Costs. Installation complexity and time. FLATURES / BENEFITS 3C 4 C4wslarryngTrom0.3m(1R)tD1.8m(6R) (AZ 240') 28 EXISTING (3) nLTER'S F �CV-G Rom 5.925 GHZ tD 8a GF¢ vr<tT1 support Mr W 03eDald fre�QIJf+ "' rang3G (5.925-7.125, (AZ 120') NOKIA /RADAR FILER 7.125 8 5 ,10.0-i1. , MCI 71.086.0 GHz} OD reduce amerr3 requrErnts x1C 5'mp t�' ICglVls (TYP 1 PER SECTOR) (m and w) and dial a%arlzea isaX and m models omr, tale ablh' SD Lpgab: from ove tD dual pdafiznal and dlarge -eq*fy.le6 ii tt* :ed LCw-proIlle wGign m TAXI" CanSP01 01 regUI efYWtS. xmC lard and 3'Itenna Weg 2C SiT(.Vred m0tlTti'1g oesg1:D axsier3te Irstaiiativ 3B (EMPTY) -) CDnpaCtL'ne EASY models are er-ra Igrr. and easy:D trarsport, diway and tlpgrzde ECTOR 3 (AZ 240') SECTOR 2 . � � Fii'dC0'(Er r3dCr"Y_6 -) Te W'-Na 3nC vai dated J 3-P5gP, (=T31 EN 302 217-1-2 ClaSS 3. FCC CIaGG A i e eCM3 perbinlanCe 3A (AZ 240') 2D � Otppat'+Dt'�►1'1C5 t.p :o =5J k'r.•T. (155 TO: and even 32C krnT 1195 rrph) 'Dr vst �58X1 (AZ 120') Ar omlicnal &"' bar -3r alteinnaG 31t ma largfT 4wa fable ANTENNA AND EQUIPMENT PLAN - SPRINT LEASE RAID CENTER @ 82'-0" & 80'-0" NEW (2) SPRINT MICROWAVE DISH RFS/CELWAVE / SC2-22OBB MICROWAVE MOUNTING ELEVATION @ 80'-0" GENERAL SPECI F I CA T to N S Prowl Type Profile NO SCALE I A PwfOfn`an`e Poiarization :antenna Input Rsfir cctur R3"ie Ina wor Planning Admin Approval City of Coppell 01 /31 /2020 mparon-boswell JS -AIR IP-20C INSTALL (4) MICROWAVE CABLES BELKIN / CATSE (1/4") NO SCALE I B L LLC IFIC:.. iPeCIFCAlIUNS LD_ M ldin LOW r1d Gain Gain High Band Gain Fi B R30o XPD KU V S VvR 1 R L Regulatory Compilance FALLHANICAL S PECi HLA 110NS E16Y3" Ad)uetrTtent Abntutn Ad)uletment Potartiatlon Ad)usbtwt htounting Pipe Dlameter nynlmum Mounting Pipe Dl3meter maximum Approm milts 'A'91ght SuM v31 'vVlndspeed Oper3ttonal Vlln(3epeed PUdR�,T,.H LLR ACCLSiGRILS ophorly $"Ybff Point to point antenna: C.ompactlincEasy Ultra I•ich PBR 220 1 Part R9W White RAL 9010 Ot (not appkable) GI-C 212 - 23A C!•Tee6 1.5 E5 403 C5 411111 to 41S dB 30,0 VMVR l dB 129 (1 B ) E151 EN 30t2217 Range 3 Clam 3 FCC Category A SRSP 321.8 Part A ft(T) oeti� oeg'E� ITYTI (in) ffn on) 19 (D) IM'h (mph) Irnn (niph) MW SPECIFICATIONS 2 0A1 t 20 :1s ♦S � JIM 114 (151 9" 252 (tss) 1a0 (1/2) Anterm Technical Features NO SCALE I C CROWN CASTLE 6191 N STATE HWY 161, STE.200 IRVING, TX 75038 Sprint 1300 E. ROCHELLE BLVD. IRVING, TX 75234 BR0ADUS /, services 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 19 JAl OB GORALSKI .................... y... • it6873 � CONSULTING ENGINEER TX PE No. 116673 FIRM No. F-17021 1106 COLBI STREET INNEDALE, TX 76060 (SM 456-2621 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT. DESCRIPTION DATE BY REV ISSUE FOR CONSTRUCTION 12/17/19 DBE 0 ISSUE FOR REVIEW 05/07/19 DB B ISSUE FOR REVIEW 03/06/19 DB A SITE CASCADE: DA03XC121 SITE ADDRESS: 160 SOUTH ROYAL LANE COPPELL, TX 75019 PROJECT: SPRINT MW PROJECT SHEET DESCRIPTION: ANTENNA LAYOUT/ MOUNT & RFDS DWG INFORMATION: SHEET #: C -L DRAWN BY: DBB CHECKED BY: EPB LEGEND MOUNTING PIPE GROUND CONDUCTOR EXOTHERMIC WELD MECHANICAL CONNECTION GROUND ROD #6 HYBRID CABLE GROUND DRAIN LINE wi 3 = MICROWAVE DISH o #6 AWG. STRANDED INSULATED FIBER & DC CABLES (TYP) COPPER GROUND WIRE (TYP) - I I I BREAKOUT CYLINDERS I I MMBTS EQUIPMENT CABINET MICROWAVE CABLE GROUND KIT (TYP) MICROWAVE CABLE MICROWAVE CABLE TO EQUIPMENT LOCATED IN CABINET SECTOR GROUND BAR EQUIPMENT GROUND BAR MMBTS GBF �000� TO EXISTING CABINET GROUNDING MMBTS GBF SYSTEM GROUND BAR GROUNDING RISER DIAGRAM (TYP) NO SCALE I A NOT IN USE NO SCALE I B � lIIII BUTT CONDUCTOR INSTALLATION UP AGAINST THE CONNECTOR BARREL TYPE SS TYPE TA TYPE HS INSPECTION WINDOW REQUIRED FOR ALL INTERIOR TWO -HOLE CONNECTORS EXTERNAL TOOTHED 3/8"Ox1 1/2" S/S NUT TYPE GT II I\ S/S LOCK COLD SHRINK OR WASHER APPROVED EQUAL S/S FLAT 1" MIN WASHER TYPE PT TYPE HA TrTrr /�i1 LABEL a�c APPLY 11J NO-Ox L--- ------ TYPE XA 1/4" MIN S/S FLAT WASHER ® TINNED COPPER COLD SHRINK OR ® S/S BOLT GROUND BAR APPROVED EQUAL �i 11 TYPE OR TYPE GL LUG TYPE VS EXOTHERMIC CONNECTIONS NO SCALE I C 2-HOLE LUG NO SCALE I D 1/4" TIN PLATED COPPER GROUND BAR (SPRINT PROVIDED)- GROUND TO BASE CABINETS, REMOTE RADIO HEADS CABLE GROUND KITS, ETC. 2-HOLE SPADE TO BE USED TO CONNECT TO GROUND BAR BOND TO BURIED GROUND RING, TOWER OR EQUIPMENT GROUND BAR INSTALL 2ND LEAD TO BURIED GROUND RING AT TOWER BOTTOM GROUND BAR NOTES: 1. APPLY NO-OX TO LUG AND BAR CONTACT SURFACE. DO NOT COAT INLINE LUG. 2. IF STOLEN GROUND BARS ARE ENCOUNTERED, CONTACT SPRINT CM FOR REPLACEMENT THREADED ROD KIT. 2-HOLE SPACE CONNECTIONS I NO SCALE I E 6191 N STATE H WY 161, STE.200 IRVING, TX 75038 1300 E. ROCHELLE BLVD. IRVING, TX 75234 4 COUNTRY PLACE CIRCLE DALWORTHINGTON GARDENS TEXAS 76016 12/18/2019 JACOB GORALSKI, PLLC CONSULTING ENGINEER TX PE No. 116873 FIRM No. F-17021 1106 COLBI STREET KENNEDALE, TX 76060 (817) 456-2621 DRAWING NOTICE: THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF SPRINT AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF SPRINT. DESCRIPTION DATE BY REV ISSUE FOR CONSTRUCTION 12/17/19 DB 0 ISSUE FOR REVIEW OS/07/19 OB B ISSUE FOR REVIEW 03/06/19 DBEI A SITE CASCADE: DA03XC121 SITE ADDRESS: 160 SOUTH ROYAL LANE COPPELL, TX 75019 PROJECT: SPRINT MW PROJECT SHEET DESCRIPTION: GROUNDING DETAILS DWG INFORMATION: SHEET #: ^ -� V DRAWN BY: DBB CHECKED BY: EPB