Loading...
Site Plan.DA01278B.ADMIN APP.05-21-2020GENERAL NOTES 1. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. SUBCONTRACTORS SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE 0 T m O bile APPROVED FOR CONSTRUCTION PROPERTY OWNER OR REP. RE ^. PERFORMANCE OF THE WORK. 2. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 3. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 4. THE SUBCONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. L600 T—MOBILE SITE NUMBER DAO1278B LAND USE PLANNER NETWORK T-MOBILE BACKHAUL OPERATIONS CONSTRUCTION MANAGER 0 a v M Q o v U Q � � w z F N ■ o LU m U r m a SQ w .14 w O v _ �LL ® cCO ILL n O ® r, SHEET INDEX 5. F THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, SUBCONTRACTORHE OPOSE AN ALTERNATIVE INSTALLATION SPACE FOR APPROVALBYTHECONTRACTOR T—MOBILE SITE NAME T-1 TITLE SHEET 6. THE SUBCONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED 7. THE SUBCONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. 8. SUBCONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON SANDY L K-C I N G U LAR #3423 ATC SITE NAME /NUMBER COPPELL #2 TX 309374 C-1 OVERALL SITE LAYOUT C-Z EQUIPMENT PLAN C-3 ELEVATION/ANTENNA LAYOUT/MOUNT DIAGRAM G-4 REDS C-5 REDS PLUMBING DIAGRAM AMERICAN TOWER 10 PRESIDENTIALWAY WOBURNMA 01801 MA THE DRAWING MUST BE VERIFIED. SUBCONTRACTOR SHALL NOTIFY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION. C-6 AMOB EQUIPMENT SPECIFICATIONS C-7 AMOB/RADIO EQUIPMENT SPECIFICATIONS I ACGI NO: 19-4680 DRAWN BY: DD 9. ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS SITE ADDRESS OF ELECTROMAGNETIC RADIATION. EQUIPMENT SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL G-1 GROUNDING DETAILS CHECKED BY: C. ZHANG A 08 01 19 ISSUED FOR REVIEW RE EXPOSURE MONITORS ARE ADVISED TO BE WORK TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS, 636 SANDY LAKE ROAD Planning Admin Approval COPPELL TX 75019-5289 City of Coppel I L 0 08/21/19 ISSUED FOR CONST. , DALLASCOUNTY20 o5ons mpar-booswell DRIVING DIRECTIONS BUILDING CODES 0=111111210111111=00 TURN RIGHT ONTO PARKWOOD BLVD (1.1 MI), TURN RIGHT ONTO TX-121 S (0.3 MI), USE THE LEFT LANE TO TAKE THE SAM RAYBURN TOLLWAY S RAMP (0.2 MI), MERGE ONTO SAM RAYBURN TOLLWAY (8.9 MI), CONTINUE ONTO TX-121/SAM RAYBURN TOLLWAY (1.4 MI), CONTINUE ONTO SAM RAYBURN TOLLWAY (1.0 MI), TAKE THE EXIT TOWARD MACARTHUR BLVD (0.2 MI), MERGE ONTO TX-121 (0.1 MI), TURN LEFT ONTO MACARTHUR BLVD (0.7 MI), TURN RIGHT ONTO PHILLIPS DR (0.7 MI), TURN RIGHT ONTO PARKWAY BLVD (0.1 MI), TURN LEFT ONTO N MOORE RD (0.3 MI), TURN LEFT ONTO INDIAN ROCK DR (0.2 MI), ARRIVE AT 636 SANDY LAKE ROAD COPPELL, TX 75019-5289. - INTERNATIONAL BUILDING CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. - NATIONAL ELECTRICAL CODE, 2014 EDITION AS ADOPTED BY LOCAL JURISDICTION. - INTERNATIONAL MECHANICAL CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. - INTERNATIONAL ENERGY CODE, 2015 EDITION AS ADOPTED BY LOCAL JURISDICTION. ALLPRO APPROVED By Antonio Sokolski at 10:04 am, Aug 23, 2019 CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 w-allproagi.com Registration No. 8242 ENLARGED VICINITY MAP .��� II - _ a Marlae Circla -� Lockhaven La m PeearC#ioUIlwle Dr p - a de —, n N N I�j G r2ange-od to ,Cedes Crest Dr. — r z �� Z _ Sand _ - — - Eagle Or =-Sugar v' Swallow La a vy Raven Ln J{{{��� jf `Maaploleaf Ln tj v :Rohm Ln � � U ��� Pheasant Ln g�. o _ $ gl Cardinal Ln - � '� a ewcren�st--� �94 1 � VICINITY MAP ` "4— ?81> t�°P ,� wPake R Zaw Poker 3� sit ITI}� F OaawlaroM -w,aeora9r° "PI9iRi8d6 PenIane� 0aw PE t C O L L Ns a4maaMn1 arPn✓yJ Frenkt rd Rd asaen�e1......... o p a� A - _ - - t Rd ad See- e a - wanards r _ akv _.-- za a� a r-1 e,rl eerc Line ' a n _ �,�oe� ` Garland ��o z ,. _ w ., rye crest- a r __ m0 ,.k_� Ia - Gzl,° eon LL Ror L' _ w II N �towletl n w I a rtiu Ln_ - w "I ay red sa - ,rv� 3� } _ , L _� �. _.m nst uv ry trz rapt - `7; Y U. rs - O x -I EWess a e. a ra � a n �- - - _ _ a; F °Ygl d LL " R h:b,TEXAS T Tha�W1&� 'E' _ ? w",,,. ra a r r e a s _ o• Irving .ems _ "`"'"°°` "I ,,,,r r. n t9 ; ,ipp T a a, '; ao _ r,erra calla esqu I r U, �I 3' erf1°r i_ r+,v '�a Ls, m r MII Grand Prairie kfe„ Hm o Imols v .' _..-, ' ` zP .` ea-sPrkya Aj k" ar - m PROJECT SUMMARY: CONTRACTORS: EXISTING 100' MONOPOLE TOWER ALLP O CONSULTING GROUP,o1 SITE TYPE A&E CONTRACTOR 9221 LYNDON B JOHNSON FREEWAY EXISTING UNMANNED COMMUNICATION EQUIPMENT SUITE 204, DALLAS, TX 75243 AT BASE OF TOWER CONTACT: CHIYU ZHANG, P.E. OFFICE: 972-231-8893 FAX 866 364-8375 SITE INFORMATION LAT: 3297110894° N TOWER LONG:-96.9742391° W ELEV 483, AMSL ENGINEER JURISDICTION: CI Y OF COPPELL ATC TOWER SERVICES, LLC. 3500 REGENCY PARKWAY, SUITE 100 OCCUPANCY: UNMANNED CARY, NC 27518 ZONING: CONTACT: SANTHOSHA SHANBHOGUE, P.E. CONSTRUCTION TYPE: MP/COLD PHONE: (919) 468-0112 FAX: (919) 4665414 APPLICANT ONE CALL T-MOBILE DUKE BRIDGES CAMPUS CONTRACTOR TO CALL 48 HOURS BEFORE DIGGING! 7668 WARREN PARKWAY PHONE 800 545-6005 FRISCO, TX 75034 INDEPENDENT LOCATORS CONTACT: MICHELLE SHERWOOD-SMITH TO BE USED ON ALL SITES OFFICE: 972 464-3926 ( ) LANDLORD AMERICAN TOWER CORPORATION 8505 FREEPORT PARKWAY , TX ILVIA CONTACT: SILVIA GUZMAN CONTACT: PHONE: (972) 999-8920 OF P. • '�•�� . rr1,yy 1 . .•_.:"�"., 2g187IA CHIYU ZNAPkG ,. 41 BLS t"r � � 08 21 19 DA01278B SANDY LK' CINGULAR #3423 ATC# 309374 636 SANDY LAKE ROAD COPPELL,TX75019-5289 DALLAS COUNTY SHEET TITLE TITLE SHEET SHEET NUMBER - T 1 SITE LAYOUT IS BASED ON PREVIOUS CD BY ALLPRO CONSULTING GROUP, INC., ACGI# 17-4216 DATED 7/25/17 & SITE BROCHURE BY ATC, SITE# 309374 DATED 11/6/17 & 5/13/1& NO INDEPENDENT SITE WALK WAS PERFORMED BY ALLPRO CONSULTING GROUP, INC. TO VERIFY EXISTING SITE LAYOUT OR DIMENSIONS. IF ANY DISCREPANCY IS NOTICED BETWEEN THE ACTUAL SITE LAYOUT AND THESE DRAWINGS, PLEASE NOTIFY ALLPRO CONSULTING GROUP, INC. FOR A REDESIGN. (E) T-MOBILE 10'-11"X14'-2- CONCRETE PAD SEE C-2 FOR EQUIPMENT PLAN 42'-2" NORTH FOR 24" X 36" PLOT - 1/2" - 1' 0 1' 2' 4' FOR 11" X 17" PLOT - 1/4" = 1' Planning Admin Approval City of Coppell 05/21 /2020 mparon-boswel I (E) 6'X14' CONCRETE PAD BY OTHERS SEE C-3 FOR ANTENNA LAYOUT (E) CMU WALL 0 ¢ o Q < 1 v ■ LL LU Z H LU ■ O ■ m¢Nui U,3:E2 LL LL ■ L 00 o ti LL A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 19-4680 DRAWN BY: DD CHECKED BY: C. ZHANG A 08/01/19 ISSUED FOR REVIEW 0 OS 21 19 ISSUED FOR CONST. ftftmwo ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 www.allprocgi.com Registration No. 8242 DA01278B SANDY LK- CINGULAR #3423 ATC# 309374 636 SANDY LAKE ROAD COPPELL, TX 75019-5289 DALLAS COUNTY SHEET TITLE OVERALL SITE LAYOUT SHEET NUMBER C-1 (E) BOTTOM COVP (E) (4) FRLB r (TO BE REMOVED) 14'-2" (E) 12„ a ICE BRIDGE ~ O E FCOA I I TO BE RELOCATED d I I a i a O ' /F (E) TWC a d 0 d � a (E) SSC (E) 1.24" LOW CAP (E) (16) 7/8" HYBRID CABLE F COAX CABLES (E) BTS (TO BE REMOVED) J _ I (TO BE REMOVED) a � O � d d a ° da 4 a (E) TELCO CABINET (E) P`PC (E) FIBER ENCLOSURE EQUIPMENT LAYOUT - EXISTING NORTH FOR 24" X 36" PLOT - 3/4" = 1' 0 6" 1' 2' FOR 11" X 17" PLOT - 3/8" = 1' (E) METER d (E) 12" ICE BRIDGE r -- \ i 0 Q a a Planning Admin Approval City of Coppell 05/21 /2020 mparon-boswell (E) BOTTOM COVP r ® r ® (E) RID LOW CAP (E) (ig) BLES HYBRID CABLE r COAX CABLES 14'-2" a � - 4' N 6„ / aI / I I NEW DELTA (E) FCOA 400A SSC (RELOCATED) (E) TWC <1 a \ 4 Q 7 \ � Q O d - (E) TELCO CABINET (E) FIBER ENCLOSURE 1'-6" dQ d u a Q � (E) PPC d a 4 (E) METER " EQUIPMENT LAYOUT - FINAL 2 NORTH FOR 24" X 36" PLOT - 3/4" - 1' 0 6" 1' 2' FOR 11" X 17" PLOT - 3/8" = 1' j NEW AMOB RACK W/ I L I (2) AMOB 44 d 40 a zl 4 a I M O 5jQ C a' O V UQ Q � � ■ U d � W Lu Lu H ■ m¢�6i LU Of ■ Y ILL ILLL o O ■ ■ ■ A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 19-4680 DRAWN BY: DID CHECKED BY: C. ZHANG A 08/01/19 ISSUED FOR REVIEW 0 08/21/19 ISSUED FOR CONST. ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 www.cliprocgi.com Registration No. 8242 =�'P •+ Yl1•�HANG �••• 28187-a 08/21/19 DA01278B SANDY LK- CINGULAR #3423 ATC# 309374 636 SANDY LAKE ROAD COPPELL, TX 75019-5289 DALLAS COUNTY SHEET TITLE EQUIPMENT PLAN SHEET NUMBER C2 mQ m� a � o (E) PANEL ANTENNAS o0 0 o II I II BY OTHERS @ 98' AGL x ti N a (E) MW DISH a x o a¢ o ¢ o 0 N X �X O Q X pUj Q BY OTHERS @ 95' AGL '11 i o �a o (E) PANEL ANTENNAS BY OTHERS @ 90' AGL (E) PANEL ANTENNAS BY OTHERS @ 85' AGL (E) PANEL ANTENNAS BY OTHERS @ 75' AGL (E) MW DISH BY OTHERS @ 71' AGL (E) (4) T-MOBILE PANEL ANTENNAS MODEL# APX17DWV-17DWV-S-E-A20 NEW (4) PANEL ANTENNAS MOD L# FFHH-65C-R3 SECTOR A, 0° @ 65' RAD CENTER SECTOR B, 120' @ 65' RAD CENTER SECTOR C, 240' @ 65' RAD CENTER SECTOR D, 60' @ 65' RAD CENTER I I I I I I I I (E) 100' MONOPOLE ® II (E) 1.24" LOW CAP HYBRID CABLE (E) (16) 7/8" II COAX CABLES LTZZI MFUI: 16 ELEVATION 24" X 36" PLOT - 3/16" = 1' 0 2' 4' 8' 11" X 17" PLOT - 3/32" - 1' (E) (4) FRIG (1) PER SECTOR (TO BE REMOVED) CO P 0 o�Els G1 NIS PQ�1�o�� 1� OJPo Pti / (E) (4) TMAs ATMAP1412D-1A20 (1) PER SECTOR (TO BE REMOVED) 00F y56 �L1p0 `ESOP pJP�P �tP 0 �O��XP6�,6�P'A 43 P 0 \ + PQ, gp0 Pti (E) (3) FXFB (TO BE RELOCATED TO GROUND LEVEL) (E) TOP COVP I LNX 6FTq 610 TMJ eFr oZ os M RF�01FD �.6sT�B�. J Fk � qZ �gAk7BF14 QU 9�0,��� >> X2p, F q?o ®, ANTENNA LAYOUT - EXISTING 2 NORTH FOR 24" X 36" PLOT - 3/8" = 1' 0 1' 2' 4' FOR 11" X 17" PLOT - 3/16" = 1' NEW 4 AHLO 1 PER SECTO OP0�1 P �F-S F%,900 1�0�1' 1p0I % �p0 �' ol`ti Pti Pe�100�1 ��, OOPO a 0 o � Lv � � o o j � o d N Q j N xoo Qr`oo W W U X Q �a �o NEW 4 AHFI 1 PER SECTO STRUCTURAL ANALYSIS IS BY ATC TOWER SERVICES, LLC, ENGINEERING# 12948455_C3_01 DATED 5/23/19. NO NEW ANTENNAS OR EQUIPMENT SHALL BE INSTALLED WITHOUT THE APPROVAL OF A STRUCTURAL ENGINEER. MOUNT ANALYSIS BY TOWER ENGINEERING PROFESSIONALS, PROJECT# 99402.270150 DATED 7/3/19. NO NEW ANTENNA OR EQUIPMENT SHALL BE INSTALLED ON SECTOR MOUNTS WITHOUT THE APPROVAL OF A STRUCTURE ENGINEER. ALL INSTALLATIONS SHOULD COMPLY WITH ANSI/ASSE A10.48 AND ANY OTHER SAFETY STANDARDS. PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELD VERIFIED BY GENERAL CONTRACTOR PRIOR TO CONSTRUCTION TO AVOID ANY INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS. IF INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS IS DISCOVERED DURING FIELD VERIFICATION, PLEASE CONTACT ALLPRO CONSULTING GROUP INC. FOR DESIGN REVISION PRIOR TO ANY NEW ANTENNA INSTALLATION. Planning Admin Approval City of Coppell 05/21 /2020 mparon-boswell NEW 4 AHFI 1 PER SECTO NEW 4 AHLO 1 PER SECTO (E) TOP COVP (E) MONOPOLE d �� n1���1n0I�'1900 O E PLATFORM MOUNT �P p01 PL % (E) UPPER O�pO GROUND BAR ITRUNK CABLE! (E) TOP COVP (E) 1,24" LOW CAP HYBRID CABLE COAX1 CABLES F� g MAT19 11ry-43 1 PER SECTO 2p. p q?O ANTENNA LAYOUT - FINAL rT� NORTH FOR 24" X 36" PLOT - 3/8" - 1' 0 1' 2' 4' FOR 11" X 17" PLOT - 3/16" - 1' MODEL# PANEL ANTENNAS FFHH-65C-R3 ANTENNA/RRU MOUNT DIAGRAM 4 FOR 24" X 36" PLOT - 3/4" = 1' 0 1' 2' FOR 11" X 17" PLOT - 3/8" = 1' r� rl ¢ o <W C> 111 ■ LO v LU Z LU ■ m w d ■ m¢cnLii W o U ■ Y W LI_ LL o m 0O ■ ■ ■ ■ A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 19-4680 DRAWN BY: DD CHECKED BY: C. ZHANG A 08/01/19 ISSUED FOR REVIEW 0 08/21/19 ISSUED FOR CONST. ALLPRO CONSULTING GROUP, INC 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 www.allprocgi.com Registration No. 8242 DA01278B SANDY LK- CINGULAR #3423 ATC# 309374 636 SANDY LAKE ROAD COPPELL, TX 75019-5289 DALLAS COUNTY SHEET TITLE ELEVATION/ ANTENNA LAYOUT/ MOUNT DIAGRAM SHEET NUMBER C -3 &r.ID DA0127M Iirr1..: Final Yenwn: t4.3 PM -Tree: L600 ,Ip""1 8MrA 19 8:2130 AM ,kp V� ;Oy: GSM190INSSena1 Lw Medifl d! BMIZO198:21.38AM Law Modi5edgo CSM19001S8ene1 RANT -plate! 6794AS�t325 Sw C A! 4 ,y+.-..C-nl: 9 ErNaan 1 E.d.nreiyp. P4xilary Egdpmarx 9aleaied B.—bad B. 6.ed R�rdraar Syr,.m NSN Low Cop HCS 150R Noltie HCS 2.07runk'S@lW LerTyrr' lieeei B°" Large coup IAPLie HCS 2-0 Tew.r.Jrnd;en Power wbyrnm R.d'o T—WnISVv RJdaWw.IYMrt Section 1 - Site Information saes P.,m.: Sandy Lk-Ongufar#3d23 ky�.4: 32971109Bdp0 sae aa..; Monopole kmvt�•- A.9742391 D00 Siio Type: Structure Non Suring Address: 838 Sandy Lake Rd Plsn Year. Ciry,_q.h: Coppell, T% Marker: DALLASTx Reglo,! SOUTH Vendor: Nokia Lae4lsrd! Aman4an Tourer AL T.mplw! 67! 4A SR_lr21 Co.s Llm Co -a 8 TMA6N..t: 4 WNfArn: D Propose d RAN E grripm ent reap.b: 8794A SR_U21 2 3 4 GeRrlc C�.hlnr Town Top Mou ra Ganrk 31D. Suppo TM—alFS'ME FSkIF IJ 2id] E 210o W10a ASIA AB1Apra1 ABtA LNO L1100 PF11 1 LiP7 AS1K 125 s.. [LW{l!c A&L NeFtO;L�AFHI A111ospa FXFB(.I)) 15'HCS 1t rCable-16AM 2PR .4irkcah Ic 41 Lang. COUP OVIS2IH9Ver 142 Prq-d type- L6W CAPS Prof r! D: DA01:2788- No P'q*d C0 Eg4lpmru on Pop arbor upgoels: Amnna s:RFs - APXI 70WA4 170IAA-^r E A20 (6enaraly Available) (w4)1 CoTrunscopa - FFHH •65GR3 [Gan rely Availabla)Oc4) HCS: NddaHC82.CTrunk'Salad Length'(LJ wppwoco(:f)I N15'HCS 2.0 Junper Cahre- IUPWM 2PRAiracele (Genaalfy AYaaahte) (.4)I NSN Low Cap o1 ) J—b- Box-. Nokia HCS 2.0 T— Junction Sox (G--Ily Auaila ale) Ix1] I Large COW (1.) TK Rx F uarsras: • W451221 -� UL: 21402155 MHz 1 0L: 1740.17E5 MHz • PCs 0900) •• UL:1045-ISW MHz & 1966.1970 MI I OL: 18Li1 1870 MHz& IIII 90 MHz • 70O•� ULB)D•704 MHZ I DL: 729.734 • e00•, UL: e23642 MHz I DL: 608.688 MHz Barc4d¢a sslact aka• &eal�rs'seket tiza' (}t,eaaga iyp. Aare. Asr.a.ueex M. TIk Il.kkr Pom a�a.er L. psrk TwY. Rerrrknd TaN. Dees nm i.se. E.Tt Cobb. Thus DIRHxwn7 C—bie Redo 50-carLvFres*r CO—WTylr Sector 2 (Prop osedIview hem Heat [Notao the images show view from he hind! I 2 P1 I P2 1 P3 1 P4 1 P5 IJ'prr.r$pppa TO n St* 1A - TMAT19.1143 VL � 3] P8 I A.%... I 1 1 2 1 4.1111 D N.411A Pam P1 P2 P] P4 P5 P6 A."T L. l700 LSO 900 L600 G1900 gig 900 L1800 L230Q ER Dirkll eh- N800 N800 1 llwht�dT-h- D--T k, E.Tr :FI•:T r Irr epos a e+vrew rro m rrenr [n ose: v.e rm ag e e snow new Tram oa nmoy DpWan I fo,.rapeirv. A-l�[daor Macon Osr�Lin Rode Anksns I 2 Seclu EgslpmeH AsV.ea Mod.l Ccmmsoopa- FFHI+66G R3(Odo) RFS- AI 7DWhL17aWS.E.A20 fOrmrb Azlm.11 O r'� Ca+.r.yr irp M.TIIt Q ll Aswus Iwtgkt Pone 151 P2 1313 P4 P5 PB +ryei& Ace.Thsk. L700 ® 200 LiOD Gi900 900 L2100 L1900 900 9QQ ER) M.TIk D.rkTaoh. N800 N800 N.lykt ReeRhpd Tsµ- Pom Dam mrn Teat. Axare ixL. E-Ta DrkTr1. C.I4aa GrlaAc Faador Caexl.sl RnRktrd Tsµ, YMA. Conn s-pe TW.Style , A - TMAT19-1139 (E14ROOP13] CAAMonne) DawmrnT.h- Cobbs DlpwwreJ L'onpinear TR1As k.do S"wrEvabmeal Daoeorrrard E-Nivw.t: &ape eHYadc Dbkman! Con6w.rs Rsd� Sxbr EgelprceN Carnmsmps TYA In Style 1A - TMAT1&11-43 (E14RtOOP19) IAz4rAarnal Sec1u4(Proposed:view hem[re-t[Nate: the mages ahew viewfrom hehinilI I 1 2 APK 179AV 17 )W11gE.A20 COL P1 1 P2 213 1 P4 `CmnxSmpe Tall In &I 1A- TTAAT1III-11-43 ( E14R U P15) IA4LAarnal P5 PB ■ r� �Q o 5O U Q � ■ UU Z F 04 • MwC5 IR CMD ¢ U W Lll�Of ■ YooI LLL o CO O ■ A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 19-4680 DRAWN BY: DID CHECKED BY: C. ZHANG A 08/01/19 ISSUED FOR REVIEW 0 08/21/19 ISSUED FOR CONST. Aftwmao ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 www.allprocgi.com Registration No. 8242 CHIYD ZHANG ......................... 08/21/19 DA01278B SANDY LK- CINGULAR #3423 ATC# 309374 636 SANDY LAKE ROAD COPPELL, TX 75019-5289 DALLAS COUNTY SHEET TITLE REDS SHEET NUMBER C-4 Configuration 6794A_SR_U21 ■ Alpha, Beta, Gamma B Delta �a o Legend Y can C? U Q m Awu}F ■ en v LH� LJZ Aw�um xvcs ■ . � O = ws ■ Lu 9 E U urnrs Aws ` ' (D LI_ LL o LTE PCS ■ t� LTEAM ..;vs For Seta, Gamma & OelEa ■ ■ ■ AMERICAN TOWER ® AHLaA 10 PRESIDENTIAL WAY WOBURN, MA 01801 AHFIB ACGI NO: 19-4680 DRAWN BY: DD CHECKED BY: C. ZHANG A 08/01/19 ISSUED FOR REVIEW 0 08/21/19 ISSUED FOR CONST. }ep w1T 1 L L P R 0 CONSULTING GROUP, INC. m 4-83 a 9221 L don B Johnson Fw 75 IPrw3i+ean Suite 204, )allas, TX 75243 Phone: 972-231-8893 x Fax: 866-36i.corn www.allprocgi.com 9anum { Registration No. 8242 tour r. Clil Yll•ZHAP..... •j �i 28187 ESAIB CSM rsr ue 08/21/19 GSHF SIRE AM ibrar T27;0 {C58I AM FSW U-S DA01278B SANDY LK- Aw ,E CINGULAR #3423 77 L ATC# 309374 [.ram. ae 636 SANDY LAKE ROAD COP289 DALLAS COUNTY �Af SHEET TITLE Oki .. RFDS PLUMBING DIAGRAM uas axN sc SHEET NUMBER C-5 ■ 1� AirScale Subrack AMOK Overview The AP�k06 is an outdoor enclosure designed t0 house AirScale System Module Indoor (ASMI) plug-in unit PI�I}Va'1ani5. r; • The AMOB has a thermal management system using a heat exchanger (HEAL) to maintain proper $ p p temperaturefor the indoor -rated y� HEX PILL Enclosure' Front View (door remavedl AirScale Subrack Outdoor AMOB datasheet k - - - - O 1 � Y "' M U Q � � ■ C,)EL V W Z F CV o - O ~ • mLij w LL LL • � m � • • ■ ■ Enrironnir l protection IP55 aulssa "� Featlre description: wdth rhoe:coveA 407 moo • Outdoor Suhrx,for ArS[da Sy stem Mn ftle rndoor plug-in uni is Ih6d1It l�aGnkU 648 dies inw 19 inth rack) Nigh pa Heat Exchanger"HEX" 487 rrrs. (. JmA surrd oil pE7Qs Or II injol Ocpth Total 635r 1472r-mfro m•acxroouitmgwrfacel CarrpatitAewthFlexr8T5n hkV aricsstack/oirVVwAI/pde/racretallatcn W ekghrs 2311;g P14M mrrosum Compatible with the 3rd Fart 19"rac ks and cabinets if It follows clearance s 3 kg ASFAECom ModAel andairflavC remenCS 2kg A810. tCp.. ton lycil,00 92kg % C. pally n Care• 9 Epa sia l PMUotoiwtAAMOSi1eFderCOAcabinet a1kjj FjICaRasilyE2Cons .6EvanaioN 1,Er—F•elecC- IP55 ServicedvorsmfrwRaldrears+des Opeslogiemparature-o6•Cupto«55Ydrihoulwla, radratronl ASMI PlUS. j�9g The AP+IOB has features that allow it to be mounted in various ways, including attachment to a wall or pole, as part of a standard Flexi -- - e /� lft2tal on TemFerrwre `� Arnow Oireccon HEX A56lMplYl---041] T` POU and Hea1er(-1U) Clearances For cooling ASIA+ABTA 3U 1 au Cni. elar! 24:--55°e SackroYonl aa13owdirecoonsvnported rorNorrrmtalFt@5, .4"rack Flea slack] Fort la 6a<Fa h�wd•xC4ar s ppar[ed Far Verd�l Hat andpde movni rig easel �0m„ r ,n m� non �e na ck and Fount 5rde -21 r 'C'. -C AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 19-4680 modulestack, and inside of cabinets such as the FCCA. ABIA AirScale CapadtyMaduIe (1-6} ASIA AirScale Comman Module (1-2} ¢r A�z Nmm�alsop:7r•d�1ta®e I,pu-v3Itege rangy F c -c sv cur L7Grr .: oe a tided to meet rum epr remen-_ a:ld s:u¢ from-40°C ..,d 02 r-ows -4R5 . -5; y F'.�nange_oe?uI[aipRpporredSbVdc. 40d<fbatmg 1ri d5e �pwrlHo 18Y8;^R� Tyzca cob-265W1.11` ns ss highes-spe l DRAWN BY: DD CHECKED BY: C. ZHANG A 08/01/19 ISSUED FOR REVIEW 0 08/21/19 ISSUED FOR CONST. 2 (2,Nokiz2a16 I'VOICIA Cod N:+kia 27 5 cend,lt c.hl enrry Loll sw-1 -600W INeate: On 55W -Fars aS low speed'r 20.5 r3x 1" on eadi left and rtht xde Confidential ALLPRO CONSULTING GROUP, INr_ 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 ww Alprocgi.conn Registration No. 8242 AirScale Subrack AMOB 446rrm117.6in � Overall ❑imensions � - 605n1m/2a.8rn 472rnrrd78Aln 420mm/16.5in a- 240mm1tt 4rn o • a� AirScale Subrack AMOB Mounting Options - Flexi Module Stack g • The AMOB can be mounted to a stack of Flex modules • An additional stacking plinth [and security brackets is required • Na equipment can be mounted above the AMOB • When mounted horizontally, the following clearances rn ust�yy be observed: =. Front: 600mm for module installation - - - '_ t��F rE 'It i `'-' '-'� If A r-:� •:`�i CHIYk1 �HAAlG / �..........................::,..; +�•, 28i 87 487mrn/79.1in Rear: 600mm for aIT flow Land maintenance) c Right/Left: 300mm for cabling IJ 08/21 /19 7jCOPPELL,IX _ 354mm173.9in [BUT 44 mJ as apt o0��t =- m —" t a;;mi I SDANDY7L$K- CINGULAR #3423 ATC# 309374 1 f/i4' - . -_ ..... stacking Plinth �t a4� -,% _ _ 636 SANDY LAKE ROAD 75019-5289 DALLAS COUNTY s 011okiatol6 Cur dential NE3KIA 10 IDNNda 2016 Crxfiderrtial NOKtA SHEET TITLE AMOB EQUIPMENT SPECIFICATIONS SHEET NUMBER C-6 AirScale Subrack AMOK PDU Power Distribution Unit • The PDU provides -48VDC power distribution and control for the subrack • The main power input is via a 2-pole Anderson connector rated for 50A • The components (housing and contacts) for the mating connector are provided with the AMQB for field crimping to 6AWG input wiring DC Input Connector 16 © Nokia 2015 Conliderntial Enr llo Mario Vale no -Heenan Civil Engineer California P.E. License No. 87011 SAC AE Oesign Group, Inc. , D w a s a en � rwtnrs +er roe m r,ve i Q Q: ierro � tin M w Or M yn .e 0 y - DC Input to ASMI o n N to HEX Harness ✓11 ,� � � v NOKIA AirScale Subrack AMOB ASIA/ABTA Interfaces ASK Iraerl La6al on NW N1m be[ of inrnrleces ciuw W wpr Parer mnnectar CC in 1 �•pple Wrnp penninal Extemal Alarm and EAC 1 HDMI t:ano-a mlerlaae Sy/iellNn�ralbn SIN 1 HOMI Inuv+n« {1n11u1aY Synchronuxlron BOUT 1 HOW Interface tou�esj Emmlon lnwil SEI 2 ,nin SAS 8D Lox Lalem sRlo 2 SFF• IMrrcn[aretw 1A51ntent EIF 5 SFP•and RJ45 IP.Etnerrrrt Tmns won Interface Local Manalpnle A LIMP I RJ45 Port cra,nd�rg car.,xw onto 1 Msx1Z amrwr AM AFI 1P3 RF4 $45 W6 agagq [ _ O � � Inlcrrnco � E!3 n E!j ELI Ln6el n„HyY N<tmDar o}iM<r}eetri Cannetror ryPtr J - .- : _ : 80 OF]cit In[a i.e $F �. ABTA 17 � Nokia 2016 Confidentlal AirScale Dual RRH 4T4R B12n1 240V� NCIKIA t AHLOAProduct Code* 474331A Supported Frequency bands 3GPP Band 12177 Frequencies Bandy adjusted IJL698-716MHz.OL72°-746MHz Band 71 UL 663 MHz- 69$ MHz, DL 517 MHz- 652 MHz Humber of TX IRX path Opipes 4 pipes, 2T2R, ZT4 R, 4T4R for both trards Instantaneous Bandwidth 1BW 17 MHz for 812 and 35MHzfor B71 1 MHz below 812 NB I0T future use ❑ coup led Eiandwidtb 0BW UL 53MHzcoatigucu5 OIL B12 17MHz+ 1 11Hz NB IvT Future use B71 35MHz Output Pourer 60W per TX shared between bands Supply Voltage 1 Range DC-48 V I -35 V to-60 V Typical Power Consumption 640W [ETSI Busy Hour Load at 4TX@6OW 450`W [Er51 Busy Hour Load at 4TX@20W Antenna Ports 4 ports. 4 3-10+ Optical Ports 2 x CPRI 9 8 Gbps AL Control Interfaces AlSG3 ❑and RET ID�on ANT & ANT3i Other Interfaces External Alarrn MID R-25 (4 inputs, 1 0utput] DC Circular Power Connector Physical 560 men x 3013 men x 189 men Approximately 38kg with no covers or bra ckcts 0 perating Temperature Range - 4OPC to 55°C Iwith no solar load} Surge Protection Class it 5A Installation Options Polc, Wall, Book Mount 1� O j Q C �Yc�n ■ CID U Q � � � v W LU F CV ti ■ cc: O> co D " LU Of — tb tL IL ■ Y ILL o m O ■ ■ A AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 ACGI NO: 19-4680 DRAWN BY: DID CHECKED BY: C. ZHANG A 08/01/19 ISSUED FOR REVIEW 0 08/21/19 ISSUED FOR CONST. ALLPRO CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 ww Alprocgi.com Registration No. 8242 1OF 111;� 411 • CHIYl1•�HANG . ..� 08/21/19 DA01278B SANDY LK- CINGULAR #3423 ATC# 309374 636 SANDY LAKE ROAD COPPELL,IX 75019-5289 DALLAS COUNTY SHEET TITLE AMOB/RADIO EQUIPMENT SPECIFICATIONS SHEET NUMBER C-7 ■ TYPE PT TYPE HS TYPE YA-2 TYPE VS W Z F N ■ m w d a ER I■ m Q D W W d �= ■ Y°oLLLL p 0 ■ ■ IIIII ■ ® o Q WOBURN, MA01A8010 AMERIOWER 10 PRESIDENTIAL WAY TYPE GT TYPE VS TYPE 2—YA-2 ACGINO: 19-4680 DRAWN BY: DID CHECKED BY: C. ZHANG A 08/01/19 ISSUED FOR REVIEW IIIII 0 OS 21 19 ISSUED FOR CONST. TYPE SS TYPE VBC TYPE YGHC GROUND CONNECTION DETAILS NOT USED 2 ALLPRO N. T. S. N. T. S. CONSULTING GROUP, INC. 9221 Lyndon B Johnson Fwy Suite 204, Dallas, TX 75243 Phone: 972-231-8893 Fax: 866-364-8375 www.allprocgi—ro Registration No. 8242 WALL MOUNTING BRACKET, NEWTON INSTRUMENT CO. 5/8-11x1" H.H.C.S. BOLT, CAT.# A-6056) NEWTON INSTRUMENT CO. (CAT.# 3012-1) INSULATORS, NEWTON INSTRUMENT CO. CAT.# 3061 —4) 0 0 0 0 0, 0, 0 0 0 0 5/8" LOCK WASHER, 0 NEWTON INSTRUMENT CO. 0 ° (CAT.# 3015-8) 0 ° 0 ° CLEAR HEAT SHRINK ELECTROPLATED LUG WIRE/CABLE 3" OF SLACK — TYPE 315 STAINLESS CAP SCREWS HARDWARE ASSEMBLY USED — = t�OF T►y ' ! •: / .. ........-................... CHIY0 ZHAAlG ..� %.......... `1+.�_, .`281.87•'-i �' 8�' '•' '!� 08/21/19 DA01278B SANDY LK- ° �,\ NOTE: COPPER GROUND BAR 1. FOR GROUND BPND TO STEEL ONLY: 1/4"x4"x20" MIN. NEWTON INSTRUMENT CO. CAT.# INSERT A TOOTH WASHER BETWEEN B-6142. HOLE CENTERS LUG AND STEEL COAT ALL SURFACES TO MATCH NEMA DOUBLE W/ ANTI —OXIDANT COMPOUND. LUG CONFIGURATION 2. ALL HOSES ARE CS 1/16" 3. USE NO—OX—ID "A —SPECIAL" ANTI —OXIDANT GREASE ON ALL LUG CONNECTIONS. 4. LUGS MAY BE INSTALLED ON BOTH SIDES OF THE BUS BAR AT THE SAME POSITION #2 AWG SOLID BARE WHERE NECESSARY BUT MAY NOT BE TINNED COPPER WIRE WITH STACKED ON THE SAME SIDE OF THE BUS 2 HOLE LUG BAR IN THE SAME POSITION. THIN COATING OF ANTI —OXIDANT COMPOUND INSIDE THE LUG BARREL COMPRESSION LUG CRIMPED AT LEAST TWO TIMES — USE FLAT WASHERS IF SLOTTED HOLES FLAT WASHERS TO BE USED LOCK WASHERS (HELICAL OR BELLEVILLE) HEX NUT (TYR) 3 MIN TO 5 MAX THREADS EXPOSED CINGULAR #3423 ATC# 309374 636SANDY LAKE ROAD COPPELL,TX 75019-5289 DALLAS COUNTY SHEET TITLE GROUNDING DETAILS SHEET NUMBER 5. NO HOME RUNS ON CROWN TOWERS GROUND BAR DETAILS 3 N. T. S. GROUNDING CONNECTION DETAILS N. T. S. 4 ^-1 V