Loading...
Astra Zeneca PMU Establishment - Site Plan - Revision 01 2020.10.26.ADM APP.10272020Planning Admin Approval mparon-boswell COPPELI 10/27/2020 AstraZeneca PMU Establishment Beck Architecture Project #172911 Project Team: Owner Architect Civil Structural Electrical AstraZeneca Beck Architecture, LLC Hart Gaugler+ Associates Armstrong -Douglass Cummings Electrical 508 Wrangler Drive #100 1601 Elm Street 12801 N. Central Expressway 1601 Bryan Street 14900 Grand River Road Coppell, TX 75019 Suite 2800 Suite 1400 Suite 202 Suite 124 Dallas TX, 75201 Dallas, TX 75243 Dallas TX, 75201 Dallas TX, 76155 PHONE: 787-905-0113 PHONE: 214-303-6200 PHONE: 972-239-5111 PHONE: 214-237-7022 PHONE: 817-355-5300 FAX FAX 214-303-6300 FAX 972-239-5055 FAX - FAX: 817-355-5355 ATT: Chris Bryan ATT: Scott Somerville ATT: Jamie Gallagher ATT: Scott Armstrong ATT: Shane Cranford Jon Mindmp Cindy Kula Reinaldo Romero EMAIL: Chds.Bryan@astrazeneca.com EMAIL: scottsomerAlle@beckgroup.com EMAIL: jgallagher@hartgaugler.com EMAIL: sm@armstrong-douglass.00m EMAIL: scranford@cummingselec.com jonmindrup@beckgroup.com ck@armstrong-douglass.00m rromero@cummingselec.com Construction Beck Construction, LLC 1601 Elm Street Suite 2800 Dallas TX, 75201 PHONE: 214-303-6200 FAX: 214-303-6300 ATT: Todd Powers Graham Comstock EMAIL: ToddPowers@beckgroup.com GrahamComstock@beckgroup.com Vicinity Map: rs PROJECT ADDRESS: ASTRAZENECA 508 WRANGLER DR #100 COPPELL, TX 75019 Submissions: SITE PLAN - REVISION 01 10/26/2020 DRAWING LIST Rev I Issua Data Sheet N.. Sheet Naar B 10/26/20 A0.00 COVERSHEET A 10/13/20 C0.01 SITE PLAN B 10/26/20 A1.00 PLAN AND ELEVATIONS B 10/26/20 1.1.00 LANDSCAPE PLAN 7c< BECKARCHITECTURE 1807 ROSS AVE SUITE 500 DALLAS, TX 75201 PH: 214-3036200 FAX: 214-3036300 WWW.BECKARCHITECTURE.COM JON MINDRUP TEXAS REGISTRATION #18734 -�QEM A Si 1� of Z�+ ARCHITECT SEAL 10-19-2020 CURRENT SUBMISSION: SITE PLAN APPROVAL - REVISION 01 # DATE SUBMISSION A 10/13/20 SITE PLAN APPROVAL PACKAGE B 10/26/20 SITE PLAN APPROVAL - REVISION 01 ASTRAZENECA PMU ESTABLISHMENT COVER SHEET 172911 AO.00 JOB NO. SHEET UoT ,. UU_ a \ ------ uar PRKS ESoCLD1'M 134.--- 6' �f SIDEWALK quo SIDEWALK WRANGLER DRIVE WRANGLER DRIVE U..—, E ^I L SIDEWALK II rl �17 I L L Q I I FIRE HYDRANT IS 6' SIDEWALK N w E S 0 W cxArxm scAlE-1^=ao� SITE DATA SUMMARY TABLE LOT JR1 EWSWNG ZONING LIGHT INOUSMAL BUILDING USES OFFI WAREHOUSE LOT AREA (ACRES) 2844 BUILDING AREA (SQUARE FEET) ii6,OW BUNwING HEIGHT (FEET-O/STANCE TO TALLEST SUX&NG ELENENT) Ji LOT COVERAGE (PERCENT-XXXV J7 REWIRED PARKNG -OFFlCE I/JOOSF-46.400/JW 135 SPACES -WAREHOUSE 1/I000SF-68,600111000 l0 SPACE5 -TOTAL 225 SPACES PROWDED PARKING TBO NOTE: HANDICAP PARKING IS PRONGED IN ACCORDANCE WITH ADA STANDARDS LEGEND PROPERTY LINE aCONCRETE SIDEWALK 2z PARKING COUNT 0 EXISTING TREE 70 EXISTING TREE TO BE REMOVED NOTES: 1. ALL DIMENSIONS ARE TO FACE OF CURB UNLESS OTHERWISE NOTED. 2. ALL ON -SITE ELECTRICAL CONDUCTORS ASSOCIATED WITH NEW CONSTRUCTION SHALL BE LOCATED UNDERGROUND. 3. ALL THE REQUIREMENTS OF THE CORRELL SOIL EROSION CONTROL SHALL BE MET DURING THE PERIOD OF CONSTRUCTION. 4. ALL CURB RADII ARE 2.0' UNLESS OTHERWISE NOTED. 5. ALL ISLANDS ARE 9.0' WIDE UNLESS OTHERWISE NOTED. 6. ANY TREES REMOVED SHALL BE MITIGATED OR REPARATION PAYMENT MUST BE MADE TO THE CITY. Planning Admin Approval mparon-boswell COPPELL. 0/2��2020 z a a Lu N < < F 0 SITE PLAN ASTRAZENECA PMU BLOCK S, LOT 3R-1 2.644 AC.A c CITY OF COPPELL y n a Z DALLAS COUNTY, TEXAS 6 S y N o o t U o a SHEET 1ASIO—ES, INC. ARNC 117,C �zso, ,ma 16 °M ST'EEF su TE zeao oss'IEAN1-NTACT:J0N NINoauP �CK°RQH) �A`U9 OM C0.01 AUGUST 26, 2020 EXISTING TILT WALL BUILDING EXISTING TILT B e WALL BUILDING B EXISTING TILT WALL SCREEN WALL OF 8" CMU W/ CAST SCREEN WALL OF 8" 'MU W/ SCREEN WALL OF 8" CMU W/ CAST BUILDING BEYOND STONE CAP AND CEMENTITIOUS CAST STONE CAP AND STONE CAP AND COATING AT EXTERIOR FACE TO CEMENTITIOUS COATING AT FACE EXTERIOR FACE TO COATING EXTERCEMEIOR TO MATCH EXISTING BUILDING. EXTERIOR FACE TO MATCH MATCH EXISTING BUILDING. IS HEIGHT FROM GRADE VARIES EXISTING BUILDING. HEIGHT HEIGHT FROM GRADE VARIES (MINIMUM 8'-0"). FROM GRADE VARIES (MINIMUM 8'-0"). (MINIMUM 8'-0"). 10Td" iW'd" 107'-0' - - - - - - - _ Level 1� - - - - - - - - - - - - - - - - - - - _Lever -- - - - - - - - - - - - - - - - - - - - -Level-� 100'-0" 100'-0" 100'-0" T.O. FOOTING T.O. FOOTING T.O. FOOTING 97'-4" 97'-4" 97'A„ 12 ELEVATION- WEST 1/8" = V-0" 06 ELEVATION- SOUTH 1/8" = V-0" 03 ELEVATION- EAST 1/8" =11-011 ANY REMOVAL OF TREES DEEMED NECESSARY DUE TO ROOT SYSTEM DAMAGE AS PART OF EQUIPMENT PAD CONSTRUCTION OR TRENCHING EXISTG TILT FOR ELECTRIC LINES SHALL BE DONE IN ACCORDANCE WITH CITY OF WALL BUILDING WALL BUILDING ------,--. B COPPELL CODE OF ORDINANCES, CHAPTER 12, ARTICLE 34, DIVISION 2. SCREEN WALL OF 8" CMU W/ CAST F STONE CAP; CEMENTITIOUS z it w COATING AT EXTERIOR FACE TO ~ MATCH EXISTING BUILDING. w w HEIGHT FROM GRADE VARIES us (MINIMUM 8'-0"). 10T-0" ZEMITING A1.00 EXISTING GAS NEWCONCRETE BUILDING METER TO WALK, RE: CIVIL ofi'i REMAIN - --------- ------ --- ^^ 100'I01' ///7 a NEW UNIT ------------------------------------------------ T.O. FOOTING I - SUBSTATION AND TRANSFORMER 97'4" CONCRETE EQUIPMENT �, ' J 03 A1A0 PADS NEW MOBILE GENERATOR � I 08 n — 1 n ELEVATION- NORTH 1/8 -1-0 CONNECTION POINT ° 1 - R , CONCRETE A-f02 EQUIPMENT PADS COLOR AND TEXTURED FINISH OF I - R J SCREEN WALL TO MATCH EXISTING �. I TILT PANEL BUILDING WITH CEMENTITIOUS FINISH a I. ° I I NEW UTILITY PROVIDER = a EQUIPMENT 17-1 9106' 18-0' 20' B' / - VERIFY IN FIELD ° B / SCREEN WALL OF 8" CMU W/ CAST STONE CAP AND CEMENTITIOUS COATING AT / w EXTERIOR FACE TO MATCH h -< w -EXISTING BUILDING — (7 N NEW ACCESSIBLE o6 w� RAMP, RE: CIVIL y�.,� True Project North North 07 EXISTING CONDITION OF SITE 1/4" = V-0" 01 ENLARGED PLAN - PMU ESTABLISHMENT 1/8" = 1'-011 BEC< BECKARCHITECTURE 1807 ROSS AVE SUITE 500 DALLAS, TX 75201 PH: 214-3036200 FAX: 214-3036300 W W W.BECKARCHITECTURE.COM Planning Admin Approval mparon-boswell .aF COPPELL 10/27/2020 JON MINDRUP TEXAS REGISTRATION #18734 EM A Si 7873A ARCHITECT SEAL 10-19-2020 CURRENT SUBMISSION: SITE PLAN APPROVAL - REVISION 01 # DATE SUBMISSION A 10/13/20 SITE PLAN APPROVAL PACKAGE B 10/26/20 SITE PLAN APPROVAL - REVISION 01 ASTRAZENECA PMU ESTABLISHMENT PLAN AND ELEVATIONS Planning Admin Approval mparon-boswell T n F C I T Y- O F COPPELL 10/2 //2020 TREES REMOVED: 12" LIVE OAK EXISTING BUILDING 10" LIVE OAK TOTAL DBH TO REMEDY: 22" EXISTING SOD TO REMAIN; IF DISTURBED DURING COURSE OF 12" LIVE OAK TO BE REMOVED THROUGH CONSTRUCTION, RESOW WITH SEED OF SAME SPECIES TREE REMOVAL PERMIT PROCESS; w w w w w w w w w REMEDIATION TO BE MADE BY MEANS OF NEW PAVING AND UTILITY REPARATIONS OR REPLACEMENT WITH EQUIPMENT PADS TREE(S) OF EQUIVALENT PROTECTION STATUS AND CUMULATIVE DBH (MINIMUM 310SF �727SF 3" DBH PER TREE) '� �' 1 '� 1 1 NEW SOD TO MATCH EXISTING (CYNODON DACTYLON NEW SCREEN WALL BERMUDAGRASS) (158SF) EXISTING SOD TO REMAIN; IF = w w DISTURBED DURING COURSE OF = W W CONSTRUCTION, RESOW WITH SEED OF SAME SPECIES 1139 SF W LIVE OAK TO BE REMOVED / THROUGH TREE REMOVAL _ _ _ PERMIT PROCESS; W j REMEDIATION TO BE MADE BY I jw m m m W a MEANS OF REPARATIONS OR REPLACEMENT WITH TREES) w = zOF EQUIVALENT PROTECTION STATUS AND CUMULATIVE DBH _(MINIMUM 3" DBH PER TREE) EXISTING GROUND COVER TO REMAIN; IF DISTURBED DURING COURSE OF CONSTRUCTION, REPLACE WITH COVER OF SAME SPECIES (TRACHELOSPERMUM ASIATICUM /ASIAN JASMINE)OR RESOW WITH SEED TO MATCH ADJACENT SOD (CYNODON DACTYLON /BERMUDA GRASS) EXISTING SIDEWALK WITH NEW RAMP/CURB CUT IN SAME FOOTPRINT 09 ENLARGED LANDSCAPE PLAN - PMU ESTABLISHMENT ��oi i Iv 22"LIVE OAK TO REMAIN; TO 1 _ EXTENT POSSIBLE, TREE TO BE PROTECTED DURING CONSTRUCTION PER CITY OF cCOPPELL CODE OF ORDINANCES, CHAPTER 12, w 206 SF 1ARTICLE 34, DIVISION 2 w W EXISTING SOD TO REMAIN; IF DISTURBED DURING COURSE OF CONSTRUCTION, RESOW WITH SEED OF SAME SPECIES (CYNODON DACTYLON / BERMUDA GRASS) EXISTING IRRIGATION CONTROL TO REMAIN True Project North North 1/8" = 1'-0" 01 LANDSCAPE PLAN - PMU ESTABLISHMENT act North North 1 if = 40'-011 7c< BECKARCHITECTURE 1807 ROSS AVE SUITE 500 DALLAS, TX 75201 PH: 214-3036211 .. 214-3036300 W W W.BECKARCHITECTURE.COM JON MINDRUP TEXAS REGISTRATION #18734 .�QEMA Si 7873A 'QUO ARCHITECT SEAL 10-19-2020 CURRENT SUBMISSION: SITE PLAN APPROVAL - REVISION 01 # DATE SUBMISSION A 10/13/20 SITE PLAN APPROVAL PACKAGE B 10/26/20 SITE PLAN APPROVAL - REVISION 01 ASTRAZENECA PMU ESTABLISHMENT LANDSCAPE PLAN