Loading...
DA01328A_A_and_E_CDs_REV0_FINAL_CDs_030521_UNCERT - zoning set_v1.ADM APP.033521• • T 0 Mobile • T-MOBILE SITE NUMBER: DA01328A T-MOBILE SITE NAME: CROWN #876558 SITE TYPE: TOWER HEIGHT: SITE INFORMATION CROWN CASTLE USA INC. SITE NAME: F3 - COPPELL MIDDLE S SITE ADDRESS: 1301 WRANGLER COPPELL, TX 75017 COUNTY: DALLAS MAP/PARCEL #: 65005640510050000 AREA OF CONSTRUCTION: EXISTING LATITUDE: 32° 56' 05.32" LONGITUDE: -97° 00' 05.83" LAT/LONG TYPE: NAD83 GROUND ELEVATION: 528 FT (GOOGLE EARTH) CURRENT ZONING: PD-289-C C JURISDICTION: CITY OF COPPELL OCCUPANCY CLASSIFICATION: U TYPE OF CONSTRUCTION: IIB A.D.A. COMPLIANCE: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION PROPERTY OWNER: COPPELL ISD 200 S. DENTON TAP ROAD COPPELL, TX 75019 TOWER OWNER: CROWN CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 CARRIER/APPLICANT: T-MOBILE 7668 WARREN PARKWAY FRISCO, TX 75034 CROWN CASTLE USA INC. APPLICATION ID: 540860 ELECTRIC PROVIDER: TBD TELCO PROVIDER: TBD r PROJECT TEAM A&E FIRM: GPD GROUP, PROFESSIONAL CORPORATION 520 S. MAIN STREET AKRON, OH 44311 CROWN CASTLE CONTACTS: 6191 N STATE HIGHWAY 161, SUITE 300 IRVING, TX 75038 BILL WRIGHT - PROJECT MANAGER BILL. WRIGHT@CROWNCASTLE. COM (972) 374-4275 MOHAMMED JAVAID - A&E SPECIALIST MOH A MMFD.JAVAID@CROWNCASTLE.COM (713) 570-3054 T-MOBILE CONTACTS: 7668 WARREN PARKWAY FRISCO, TX 75034 SHAMROSE ALI - PROJECT MANAGER SHAMROSE.ALI109@T-MOBILE.COM (505) 250-7489 MONOPOLE 701-911 BUSINESS UNIT #: APPLICATION ID #: SITE ADDRESS: COUNTY: JURISDICTION: PROJECT: T-MOBILE ANCHOR DRAWING INDEX SHEET # SHEET DESCRIPTION T-1 TITLE SHEET T-2 GENERAL NOTES T-3 GENERAL NOTES C-1.1 OVERALL SITE PLAN C-1.2 FINAL EQUIPMENT PLAN C-2 FINAL TOWER ELEVATION & ANTENNA LAYOUTS C-3 REDS C-4 CONFIGURATION DIAGRAM C-5 EQUIPMENT SPECIFICATIONS C-6 EQUIPMENT SPECIFICATIONS C-7 EQUIPMENT SPECIFICATIONS C-8 EQUIPMENT SPECIFICATIONS C-9 EQUIPMENT SPECIFICATIONS C-10 BATTERY SPECS & BATTERY DATA CHART G-1 EQUIPMENT GROUNDING PLAN G-2 GROUNDING DETAILS G-3 GROUNDING DETAILS ALL DRAWINGSCONTAL HEREINAREPORDIATTEDFOR22"X34".CON'TRACTORSHALLVLRIPYALLPLANSANDEHISTING DIDffiNSIONS AND CONDITTONS ON THEJOR SITE Ai SHALL L}LMEDIATELY NOTIFY THE ENGRVLEI MNWRITEVG OFAN}' DISCREPANCI& BEFORE PROCEEDIN(; W'CCH THE WORK OR RE RESPONSIBLE FOR SAME. APPROVALS APPROVAL SIGNATURE DATE PROPERTY OWNER OR REP. LAND USE PLANNER T-MOBILE OPERATIONS RF NETWORK BACKHAUL CONSTRUCTION MANAGER NOTES: PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN NOC AT 800-788-7011 & CROWN CONSTRUCTION THE HEIGHT OF THE TOWER WILL NOT BE INCREASED; NOR WILL THERE BE AN EXPANSION OF THE GROUND/LEASE AREA THE PARTIES ABOVE HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE THE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL CONSTRUCTION DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND ANY CHANGES AND MODIFICATIONS THEY MAY IMPOSE. 876558 540860 1301 WRANGLER COPPELL, TX 75017 DALLAS CITY OF COPPELL APPLICABLE CODES/REFEREN( DOCUMENTS ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES: CODE TYPE CODE BUILDING 2015IBC MECHANICAL 2015IMC ELECTRICAL 2014 NEC REFERENCE DOCUMENTS: STRUCTURAL ANALYSIS: B+T GROUP 01/22/2021 MOUNT ANALYSIS: INFINIGY ENGINEERING, PLLC 01/28/2021 CALL TEXAS ONE CALL (800) DIG-TESS CALL 3 WORKING DAYS BEFORE YOU DIG' PROJECT DESCRIPTION THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNA MODIFICATION ON AN EXISTING WIRELESS SITE. FINAL TOWER CONFIGURATION: • (12) ANTENNAS • (9) RRUs • (3) HCS PART 1 • (3) HCS 2.0 PART 3 (1-1/2") • (3) TMAs • (12) 7/8" COAX • (3) 8' ANTENNA PIPES FINAL GROUND CONFIGURATION: • (1) DELTA 40OA/V1/FUTURE 600A SSC+SB3 • (1) FCOA • (3) BOTTOM JUNCTION BOXES • (6) DIPLEXERS DESIGN PACKAGE BASED ON THE APPLICATION ID: 540860 REVISION: 0 DESIGN PACKAGE BASED ON RF DATA SHEET VERSION: 30 ISSUED:12/18/2020 • w T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 CCCROWN CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, S111.2531 Akron, OH 44311 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE l GPD JOB NUMBER: 2020724.78.876558.01 I ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIARNARY NfRL 0 03/05/2021 DTC FINAL CDs MRL tE OFT 1 tP ...........fegi411 t 131RISTOPHER J. SCHEKS i 119636 f"f 9at.'••. rICENSe�.+'�� 03/05/2021 GPD Grwp, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIItECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: IN REVISION: T-1 0 CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS: GENERAL NOTES: 1. NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP) AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWN CASTLE USA INC. Noe AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER. 2. "LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT: THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALL STAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENT INSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OF THE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE, BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAY CAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANY COMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWN CASTLE USA INC. Poe OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET. 3. PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT IS NOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITE ACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDING TO LOCAL JURISDICTIONAL REQUIREMENTS. 4. ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBING PLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTION OF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCAL REGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEING PERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND CROWN CASTLE USA INC. STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF AQUALIFIED ENGINEER FOR CLASS IV CONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION). 5. ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWN CASTLE USA INC. TOWER SITE" AND LATEST VERSION OF ANSIMA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION, AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS." 6. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 7. ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION. 10. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED BY CONSTRUCTION MANAGER. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING AND EXCAVATION E) CONSTRUCTION SAFETY PROCEDURES. 11. ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATEST APPROVED REVISION. 12. CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETION OF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 13. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWN CASTLE USA INC., AND/OR LOCAL UTILITIES. 14. THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGE REQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS. 15. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS. 16. THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 17. THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THE CONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS. 18. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. 19. THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER. 20. CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION. 21. CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS. 22. NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE PLACED IN ANY FILL OR EMBANKMENT. 1. FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY: CONTRACTOR: GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTION CARRIER: T-MOBILE TOWEROWNER: CROWN CASTLE USA INC. 2. THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODE STANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3. THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT NOT BE LIMITED TO BRACING FORMWORK SHORING ETC. SITE VISITS BY THE ENGINEER OR HIS REPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY. 4. NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THE CONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER, MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD. 5. SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THE FABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFY THE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTING OF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THE CONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE. 6. PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE. 7. UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 8. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE. 9. IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION. 10. CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCO AND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS. • m T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH -11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 ABBREVIATIONS: QTY QUANTITY REST RECTIFIER EXISTING 70t_�11 MONOPOLE ANT ANTENNA RIBS RADIO BASE STATION (E) EXISTING PET REMOTE ELECTRIC TILT FIF FACILITY INTERFACE FRAME RFDS RADIO FREQUENCY DATA SHEET GEN GENERATOR RRH REMOTE RADIO HEAD GPS GLOBAL POSITIONING SYSTEM RRU REMOTE RADIO UNIT GPD JOB NUMBER: 2020724.78.876558.01 GSM GLOBAL SYSTEM FOR MOBILE SIAD SMART INTEGRATED DEVICE LTE LONG TERM EVOLUTION TMA TOWER MOUNTED AMPLIFIER MGB MASTER GROUND BAR TYP TYPICAL ISSUED FOR: MW MICROWAVE UMTS UNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEM (N) NEW W.P. WORK POINT REV DATE DRWN DESCRIPTION DES./Q NEC NATIONAL ELECTRIC CODE (P) PROPOSED 0 02/09/2021 DTC PRELIMINARY MRL PP POWER PLANT 0 03/05/2021 DTC FINAL CDs MRL :ij t5tt OF.r' CHRISTOPHER J. SCHEKS i oi, 111I836 :�• 94e••.��ceNse°.�'�' is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ST-2 HEET NUMBER: REVISI0ON: ELECTRICAL INSTALLATION NOTES: GROUNDING NOTES: 1. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES/ORDINANCES. 2. CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDS ARE ELIMINATED. 3. WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC. 4. ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC. 4.1. ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONAL ELECTRICAL CODE. 4.2. ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TO WHICH THEY ARE SUBJECTED, 20,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION. 5. EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITH COLOR -CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC AND OSHA. 6. ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S). 7. PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS. 8. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 9. ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 10. SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW THWN THWN-2 XHHW XHHW-2 THW THW-2 RHW OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 11. POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI -CONDUCTOR TYPE SOOW CORD LARGER OR #14 UNLESS ( ) OTHERWISE SPECIFIED. 12. POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI -CONDUCTOR, TYPE TC CABLE (#14 OR LARGER), WITH TYPE THHW, THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED. 13. ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP -STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75- C (90" C IF AVAILABLE). 14. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC. 15. ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. 16. ELECTRICAL METALLIC TUBING (EMT) OR METAL -CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS. 17. SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT. 18. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 19. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION -TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOT ACCEPTABLE. 20. CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC. 21. WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLD SPECMATE WIREWAY). 22. SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL). 23. CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON -PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e. POWDER -ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAIN CLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BE MADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TO STRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPED FLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZED MALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE. 24. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS. 25. METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 26. NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS. 27. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS. 28. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY. 29. INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "T-MOBILE". 30. ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED. CONDUCTOR COLOR CODE SYSTEM CONDUCTOR COLOR 120/240V, 10 A PHASE BLACK B PHASE RED NEUTRAL WHITE GROUND GREEN 120/208V, 30 A PHASE BLACK B PHASE RED C PHASE BLUE NEUTRAL WHITE GROUND GREEN 277/480V, 30 A PHASE BROWN B PHASE ORANGE OR PURPLE C PHASE YELLOW NEUTRAL GREY GROUND GREEN DC VOLTAGE POS (+) RED'" NEG (-) BLACK"` ' SEE NEC 210.5(C)(1) AND (2) '" POLARITY MARKED AT TERMINATION 1. ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC. 2. THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. 3. THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS. 4. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS. 5. METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTS EQUIPMENT. 6. EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS. 7. CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED. 8. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED. 9. ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS. 10. USE OF 90° BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. 11. EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE. 12. ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS. 13. COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS. 14. ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR. 15. APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. 16. ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL. 17. MISCELLANEOUS ELECTRICAL AND NON -ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC. 18. BOND ALL METALLIC OBJECTS WITHIN 6It OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR. 19. GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQURED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLIC CONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT. 20. ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24- BELOW GRADE TO WITHIN 3" TO V. OF CAD -WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUIT MUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL). 21. BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDING SYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE (FERROUS OR NONFERROUS METAL PIPING ONLY). M • w T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 4 11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE L GPD JOB NUMBER: 2020724.78.876558.01 J ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIMINARY AIRE 0 03/05/2021 DTC FINAL CDs MRL 9 1 hto i STEVEN P SCHAUB i rrl q.. 114023 ¢i 03/05/2021 GPD Group, Professional Corporation Texas Registration No. 16477 ELECTRICAL SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. ST-3 HEET NUMBER: REVISI0ON: INSTALLER NOTE: USE EXISTING CONDUIT IF IT MEETS CURRENT STANDARDS. �x �x x X X -*Ax X _X x �— X X X (E) OTHER CARRIER EQUIPMENT PAD x �x x �x x �x x �x x rx x �x x X X X X x X X X X x X X X X x X X + + + + + + + + (E)OTHERCARRIER + EQUIPMENT PAD + X X + + + + + + + + + + + + + + X + + + + + + + + + + + + + + + + + + + + X X + + + + + + + + + + + (E) T-MOBILE + + (E)T-MOBILE DIPLEXERS TO BE + + FCOACABINETTO + + RELOCATED TO REMAINING + + BE REMOVED — + + FCOA CABINET LOCATION + + X + + + + (6 TOTAL) T + + + + + + + + + + + + + + + + - (E) T-MOBILE HCS 1.0 + + + + + + + + + COVP TO BE REMOVED + + + + X + + + + + t� + + + + + + + + (E) T-MOBILE FEEDLINES TO REMAIN + + + + + + + + + + (RE-ROUTE TO RELOCATED + + + + + DIPLEXER LOCATION) + + + + + + X (12) 7/8., COAX + + + + (E) T-MOBILE HCS 1.0 HYBRID + + + + + + + CABLE TO BE REMOVED + + + + + + + X + (E) T-MOBILE BATTERY CABINET TO BE REMOVED - (E) CHAIN LINK FENCE X� I X / x (E)T-MOBILEFCOA X CABINET TO BE RELOCATED (E) T-MOBILE HCS 1.0 COVP TO BE REMOVED X + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + } + + } + + + + } + + } + + + + + + + + + + + + + + + + + + + + + } + + + + + + + } + + + + + X + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 16'-0" + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + X X X X X X — X X X — X X X X (E) 70'-9- MONOPOLE (E) T-MOBILE SSC (E) T-MOBILE CABINET TO BE REMOVED ICE BRIDGE (E) T-MOBILE HCS 1.0 HYBRID CABLE TO BE REMOVED �-� OVERALL SITE PLAN SCALE. &8"=1'1-'-0'(11UL(FLx17)SIZE) N 2' 1' 0 2' 3/ifi•= (E) OTHER CARRIER EQUIPMENT PAD (E) T-MOBILE METER (E) T-MOBILE DISCONNECT (E) T-MOBILE PPC CABINET (E) T-MOBILE CIENA Planning Administrative Approval COFFELL 03/25/2021 • m T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 , AA�w GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 4 11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE GPD JOB NUMBER: 2020724.78.876558.01 J ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIARNARY AIRE 0 03/05/2021 DTC FINAL CDs MRL 1P,itt•OF.r "SShI, CHRISTOPHER J. SCHEKs i oi, 111I836 :�• 94e••.��ceNse°.�'�' is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-1.1 0 INSTALLER NOTE: USE EXISTING CONDUIT IF IT MEETS CURRENTSTANDARDS. KEYED NOTES: FINAL EQUIPMENT INSIDE FCOA CABINET, HP LARGE 3 CABINET & AMIA UNITS: (1) EX. FSME (1) EX. ESMB (3) EX. FRIAs (1) EX. FXFB (3) AMIA. (3) ASIBs (2) ASIKs (5) ABIAs (3) ABICs (6) ABILs AMIA AIRSCALE SUBRACK HOUSES UP TO (2) ASI(x) & (6) ABI(x) UNITS. (E) 70'-9- MONOPOLE FROM OLD DIPLEXER LOCATION (12) 7/8" COAX CABLES X X X X X X- X X X X FROM OLD FCOA LOCATION X X X X �� FINAL EQUIPMENT PLAN �/ SCALE. 3l4"=1'-0"(FULL SIZE) 131 1' 6" a 1' 3I8'=1'-0"(11z17) IV X X X X X X OPROPOSED (2) 2" RIGID CONDUITS TO BE ROUTED FROM THE FCOA CABINET TO HP LARGE CABINET 3 FOR FIBER CABLES & DC POWER CONDUCTORS FOR PROPOSED UNITS PROPOSED (2)1-1/2" RIGID CONDUITS TO BE ROUTED FROM THE HP LARGE CABINET 3 TO AMIA UNITS FOR FIBER CABLES & DC POWER CONDUCTORS FOR PROPOSED UNITS. (E) T-MOBILE METER (E) T-MOBILE DISCONNECT (E) T-MOBILE PPC CABINET (E) T-MOBILE CIENA Planning Administrative Approval COPPELL 03I25I2021 • w T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH —11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE IGPD JOB NUMBER: 2020724.78.876558.01 J ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 LITE PRELIMINARY AIRE 0 03/05/2021 DTC FINAL CDs MRL 1p�E'F.r' s CHRISTOPHER J. SCHEO i 119838 94e••.��ceNse°.�'�' is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. INSTALLER NOTE: SHEETNUM REVISION: CONTRACTOR SHALL RESPONSIBLE FORCIRCUIT SELECTION ANN D WIRE SIZING FOR NEWCABINETS C-1.2 0 BASED ON MANUFACTURER RECOMMENDATIONS AND NEC REQUIREMENTS. OVERALL SI HEIGHT = 79 y T-MOBILE M CL = 73'-0' TOP OF TOV 41 HEIGHT=70 OTHER CAR C OTHER CAI CL = 55'-0" OTHER CAR C (P) T-MOE (3) 1-1/2" (E) T-MOE (12) 7/B" (E) 70,_g. 1/ 1 I FINAL TOWER ELEVATION �/ SCALE: NOT TO SCALE =NNA ATFORM R 7'�o7sT7N 30oa S79 22 q (E) 70._9„ /T OS 7pp oR@�q2N (E) T-MOBILE ECC1920-VPUB DIPLEXERs TO BE REMOVED (24 TOTAL, 4 PER SECTOR) G�P01, � Jy1O�0�p°° � OFl j J�1p15 -X1��t.� OeA \ O / (E) T-MOBILE TMAT1921 B78-21A TMAS TO BE REMOVED (6 TOTAL, 2 PER A/B/C SECTORS) (E) T-MOBILE FRLB RRU TO BE REMOVED (3 TOTAL, 1 PER A/B/C SECTORS) (E) 70'-9" MONOPOLE �7'STi N@ �790 NG �P3 0,33 �9�27 �TF /TOOS RF7�M (P) T-MOBILE AHFIG RRU Y/ (6 TOTAL, 1 PER SECTOR) PT -MOBILE AHLOA RRU TOTAL, 1 PER A/B/C SECTORS) lea FOR 1 RQQQ- OQOgE a O� ey" (P) HANDRAIL KIT (SITEPRO1 - HRK12) TO REPLACE EXISTING — ¢oN0 ¢jNQ a� ;i ¢mom ¢mH mm 0 tx~xii ort xx� o �'x Wo=N ¢ j �® „`u" Ak— e/I 4i 0 O.oT m v+Nm z�oz 'C\NO�pJyP�jtN 19pO 3�' OR (E) T-MOBILE FHFB RRU TO BE REMOVED (6 TOTAL, 1 PER SECTOR) (E) T-MOBILE FRIG RRU TO BE REMOVED (6 TOTAL, 1 PER SECTOR) (E) T-MOBILE HCS 1.0 COVP TO BE REMOVED (2 TOTAL) RF'yo ,,- 1/ EXISTING ANTENNA LAYOUT �2 SCALE: NOT TO SCALE N xam � ¢NUo ¢.mo zo0 yo Nam> yNXno� o-21 o O�>� w mN x am` m x � oz Ayom Z z p�V"(P I'll eps���,t 9 \ae 6O 0 VA Py (N) T-MOBILE HCS 2.0 PENDANT (3 TOTAL) °R Op0 s 0 .g2'9Fy 2SOo Tq 720> �T�/C pRO.o F wO �NSoo@O@F �h��330�s@FTA 20, 7go 00 ?O S RF�M N/ FINAL ANTENNA LAYOUT J SCALE: NOT TO SCALE N TOWER & ANTENNA STANDARD NOTES: A. TOWER STRUCTURAL ANALYSIS BY B+T GROUP, DATED 01/22/2021. NO NEW ANTENNAS OR EQUIPMENT INSTALLED WITHOUT APPROVAL OF STRUCTURAL ENGINEER AND CROWN CASTLE USA INC. B. MOUNT ANALYSIS AND COMPLIANCE PERFORMED BY INFINIGY ENGINEERING, PLLC, DATED 01/28/2021. NO NEW ANTENNAS OR EQUIPMENT INSTALLED ON MOUNTS WITHOUT THE APPROVAL OF A STRUCTURAL ENGINEER. C. INSTALLED EQUIPMENT MUST HAVE A MATCHING CROWN CASTLE USA INC. APPLICATION AND STRUCTURAL ANALYSIS. D. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, (E) TOWER AND TOWER FOUNDATION MUST BE ANALYZED BY A LICENSED STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE PROPOSED LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS. E. NEW EQUIPMENT CANNOT BE MOUNTED TO TOWER. RELOCATE EXISTING TOWER MOUNTED EQUIPMENT TO CUSTOMER MOUNT. F. DURING INSTALLATION, THE RADIOS ARE NOT TO EXCEED 5'-0" FROM THE WORKING SURFACE TO THE TOP OF RADIOS. G. DIRECT TOWER MOUNTED EQUIPMENT MUST NOT TRAP OR INTERFERE W/CLIMBING PEGS/STEPS AND SAFETY CLIMB. H. VERIFY AZIMUTHS WITH RFDS. I. 2' ANTENNA SEPARATION REQUIRED. CONTRACTOR TO MOVE (E) ANTENNAS TO ENDS OF MOUNT AS REQUIRED. J. PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELD VERIFIED BY GENERAL CONTRACTOR PRIOR TO CONSTRUCTION TO AVOID ANY INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS. IF INTERFERENCE OR SHADOWING OF EXISTING ANTENNAS IS DISCOVERED DURING FIELD VERIFICATION, PLEASE CONTACT (A&E VENDOR) FOR DESIGN REVISION PRIOR TO ANY NEW ANTENNA INSTALLATION. K. DO NOT OBSTRUCT BEACON IF TOWER LIT. L. TOPSIDE FIBERS TO BE SLEEVED IN FLEXIBLE INNERDUCT TYPE OR SPLIT CONDUIT TO PREVENT BIRDS FROM DAMAGING FIBER OPTIC CABLE. M. TOP AND BOTTOM OF ALL COAX RUNS ARE TO BE LABELED WITH A BRASS TAG ID WITH NAME OF THE LESSEE ON IT. INSTALLER NOTE: INSTALLER NOTE: ALL EXISTING AND PROPOSED T-MOBILE EQUIPMENT MOUNTED TO THE TOWER SHALL • NEW EQUIPMENT CANNOT BE MOUNTED TO BE RELOCATED TO CUSTOMER MOUNT PER TOWER. CROWN CASTLE USA INC. LATEST • RELOCATE EXISTING TOWER MOUNTED STANDARDS EQUIPMENT TO CUSTOMER MOUNT. INSTALLER NOTE: INSTALLER NOTE: CONTRACTOR TO VERIFY ALL ANTENNA TIP I DIRECT TOWER MOUNTED EQUIPMENT MUST HEIGHTS DO NOT EXCEED BEACON BASE NOT TRAP OR INTERFERE W/ CLIMBING HEIGHT. PEGS/STEPS AND SAFETY CLIMB. Planning Administrative Approval COPPELL ? .'�wse 03/25/2021 • m T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 , AA�w GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH —11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE I L GPD JOB NUMBER: 2020724.78.876558.01 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIMINARY MRL 0 03/05/2021 DTC FINAL CDs MRL 1P,itt•OF.r "SSh CHRISTOPHER J. SCHEKS i oi, 111I836 :�• 94e••.��ceNse°.�'�' is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISI C-2 0ON: MANUFACTURER DELTA MODEL: HPL3 SITE SUPPORT CABINET WEIGHT. 551 LBS (WITHOUT EQUIPMENT) NOTE. • CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS DO NOT DRILL KNOCKOUTS THROUGH • CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE TO CABINETS AND/OR CABLING RACK ASSIGNMENT RU SLOT DESCRIPTION DESCRIPTION 21 26 2S 24 AIRSCALE 23 22 FIBER Mlx 21 20 AIRSCALE 19 �U 18 FIBER M/K IT 16 AIRSCALE Is 14 FIBER MTX 13 12 AMSCALE II 10 FIBEEll MTX 9 6 LEGACY BASEBAND T 6 S LEGACY BASEBAFD 3 2 LEGACY T BASEBAND BACK PANEL FOLDS OUT - SKIT. 33554 DELTA 6• PLINTH SHOP• G,HOOKS TO BE REMOVED AFTER CABf — - -- ISO VIEW N.T.S. 22 T REAR VIEW AK TSn FOR CM94E T ATTACHMENT FRONT VIEW 3, 3 X R ACCESS PLATES -USE III TOR), w 0 26 tr „4 SKU# 33554 DELTA 61n PLINTH SKU# 33554 DELTA 61N PLINTH PLAN VIEW SIDE VIEW BATTERY CABLE ROUTE -- 11I r LB OR LL (L.L PREFT:.RAED) KNOCKOUT WITH THE FOLED b FOR THE OC WIRE RUNNING PBATTERY CABLE PROVIDEDD THIS THE ONLY PROVIDED FROM THE DC RECTIFIER TO O , OO THE COUP FOR "CS 20 THERE ARE (3) PARS FOR A B. G KNOCKOUT YOU CAN AN LOSE. — (1 )4• RIGID CONDUIT FOR THIS PANEL OF KNOCKOUTS(WATER•TKWn ROUTING BATTERY CAKE INTENDED FOR RUNNING DC THE T TO THE RECTKER WIRES TO THE COUP rnroR2•1truOR WATER -TIGHT GROMMET IS USED HERE FOR THE BOTTON FIBER JUMPERS TO 6 FROM TFE COUP FIBER ROUTE OPTIONS INItNDto#ORAC INPl1T WINES FROM PPO--� LEFT VIEW I• KNOCnWT3 ARE INTENDED FOR (I)OC POWER TO THE CIENA (2)ETHER►ET OR FIBER CABLE FROM THE C*NA OR TELCO. WI ALARM CABO!51 ROM IHe PVC 1 i 1 T LL IS USED FROM A FLExSLE TO RIGID CONDL THAT RUNS ALL THE WAY THE PPC FOR AC WIRES THAT TERINfWLTES TO THE CABNNETS AC TERMINALS L` I ru RIGHT VIEW .1. ��_LTIYII��T� Mid 133554 DELTA W PLINTH Xt CH DRAIN DC BREAKER PROPOSED VERTICAL BA IRU FIBER MUXOEMUx PROPCISI. D GROUNDING BAALOCATK THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. INTERNAL ROUTING FRONT VIEW (OPEN) ACCESS PANEL RECtIrIERS CSR SAW SAS ROUTER MRSCALE BASESANO HORIZONTAL CABLE MANAGEMENT BAR LEGACY BASESAND T B Mobile 7668 WARREN PARKWAY FRISCO, TX 75034 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 4 11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE GPD JOB NUMBER: 2020724.78.876558.01 J ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 LITE PRELIMINARY MRL 0 03/05/2021 DTC FINAL CDs MRL Planning Administrative Approval copPEii 03/25/20 CHRISTOPHfiR J. SCHEKS oi, 111a030.....:�• 94e •.TrceNse°..�A is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, 1 UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-5 0 MANUFACTURER: DELTA MODEL: SB3 BATTERY SUPPORT CABINET WEIGHT: 310 LBS (WITHOUT EOUIPMENT) DIMENSIONS: 15 0'x35.0'x72.0' NOTE: • CORRECT KNOCKOUT TOOL REQUIRED FOR PUNCHING KNOCKOUTS. DO NOT DRILL KNOCKOUTSTHROUGH • CONDUIT MUST BE PROPERLY SECURED TO PREVENT DAMAGE TO CABINETS ANWOR CABLING b N FRONT VIEW SIDE VIEW PLAN VIEW ISO VIEW PLAN VIEW (ANCHORAGE) S• REAR CLEMMrCF THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. BATTERY BRACKET 15, or I u ul o o Ll 0 0 0 0 I L—T 00 0 0 0 0 4x BATTERY SHELVES iATTER'Y VIlRAT1t)N SKLI# 33936 MOIMT SKLI# 33936 DELTA SB3 61N DELTA SB3 61N PLINTH PLINTH PLAN VIEW SIDE VIEW SKU• 37f4T0 OEITA SBJ I M SKU# 33931- DELTA SB3 BATTERY 7Ti34- SCALE N SUPPORT CABINET T S I t 1l1 T wALE N.T. S • T • -Mobile 7668 WARREN PARKWAY FRISCO, TX 75034 I CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 4 11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE LGPD JOB NUMBER: 2020724.78.876558.01�JOB NUMBER: 2020724.78.876558.011 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIMINARY MRL 0 03/05/2021 DTC FINAL CDs MRL ,1p`I. E OF.r "SShI, CHii. T FHER J. SCHEKS l 1191M A4e••.ticegse°.�' is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISI C-6 0ON: II I I I I I I I I I I Mile nm taTA w 1L1TIM PM wu w- IWO "M pdTA V RJM 1a 93 N ON SIDE VIEW Pi10P0 IE0 DELTA SM BATTERY CANDOET ITiI1TH PROPOSED DELTA WU GM DC CABINET A (2) R)TURE CAB I ET$ BEYONM ♦' THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. 74r IN tT Zr r 11 7.6' r t'-T 4. MANGE �_____— ,______— I I I I I I I IRJTURE) I I IPUTUREI I PIIOPOBPROPOBEO OC CA TA DELTA BB3 NP4T BtIBA oc CA61ET "TTERY I I I CAMW I I I L_____J L_____J I I I L------------------------------- PLAN VIEW Jnvs JJJLJ - NCL I A J7rLJ 011 C JVrrVK I L#ADIMC I *ZJ LA TWU I 11 2rxm-w.ALE.N.Ts T1'1l PILT.s. A EDDELTA PRO3EDOELB�T_ P_ROPOSIIIIIIIII HP3 SOA DC CABO* T S07 BATTERY CABI _ _ _ _ _ _ _ _ _ I F- - - - - - IIIIIIIII OUTUM) OUTLINE) I + I I I I j I I I slw. xiooB oaTA BorPL.+It' I I I j I Planning — — Administrative Approval COPPELL rr e• Z4r a r•e• r T•-r 11••T WORIONG CLEARANCE - FRONT VIEW 3" JMU DELTA 6* PLM(TH o3/zs/zozl SKU9 33929 - DELTA NPL3 SITE SUPPORT CABINET S83 LAYOUT 2 Zrx34' SCALE N I S 11911T SCALE N 1 T • Mobile - 7668 WARREN PARKWAY FRISCO, TX 75034 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH —11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE GPD JOB NUMBER: 2020724.78.876558.01 J ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIMINARY AIRE 0 03/05/2021 DTC FINAL CDs MRL ,1p`E OF.r "SShI, CHRISTOPHER J. SCHEK9 i oi, 111I836 :�• 94e••.��ceNse°.�'�' is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C 7 0-0 THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. 0 WEIGHT (WITHOUT MOUNTING HARDWARE): 124.6 LBS SIZE (HxWxD): 95.9x25.2x9.3 IN. 1 OCTO PORT ANTENNA SCALE: NOT TO SCALE THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. BASED BOX ASSEMBLY HEAT SHRINK TU BRID CABLE WEIGHT (WITHOUT MOUNTING HARDWARE): 23.5 LBS. SIZE (HxWxD): 14.Oxi6.Ox8.0 IN. A� PENDANT DETAIL SCALE: NOT TO SCALE THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIMS) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. WEIGHT (WITHOUT MOUNTING HARDWARE): 108.0 LBS SIZE (HxWxD): 38.2x21.5x5.9 IN. n SCAAEHC SPECIFICATIONS L LE: NOT TO SCALE THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. WEIGHT (FULLY EQUIPPED): 83.8 LBS SIZE (HxWxD): 22.1x12.1x7.4 IN. CONNECTOR TYPE: 4.3-1 FEMALE r� SCALEAHLOA RRU DETAIL `� : NOT TO SCALE THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. FRONT SIDE 0 TOP WEIGHT (WITHOUT MOUNTING HARDWARE): 23.5 LBS. SIZE (HxWxD): 14.0x16.Ox8.O IN. JUNCTION BOX DETAIL `� SCALE: NOT TO SCALE THIS DETAIL HAS NOT BEEN REVIEWED BYTHE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISKAND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. WEIGHT (FULLY EQUIPPED): 70.5 LBS SIZE (HxWxD): 27.3xl2.ix5.2 IN. CONNECTOR TYPE: 4.3-1 FEMALE AHFIG RRU DETAIL v SCALE: NOT TO SCALE Planning Administrative Approval COFFELL T 03/25/2021 • III T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH —11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE L GPD JOB NUMBER: 2020724.78.876558.01 J ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIMINARY AIRE 0 03/05/2021 DTC FINAL CDs MRL tpI �F.r' CHRISTOPHER J. SCHEKS i oi, 111I836 :�• 94e••. ��ceNse°..�A' is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET CNUMBER: REVISION: 8 0 THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. AirScale Architecture Nokia AirScale Subrack (AMIA) Nokia Air Scale Subrack (AIItIA) rnain properties -It supports up to two AirScale Common plug-in units •It supports up to six AirScale Capacity plug-in units •IP20 ingress protected -Operating temperature range from -51C to •551C -It might be installed inside a 19-inch wide rack or cabinet r " The AirScale Subrack Ak11A includes -Subrack frame •Backplane for high bandwidth interconnect between AirScale Common and - AirScale Capacty plug-in units -Fans with changeable airflow direction -Blind-units to prevent cooling airflow leakage �.d. In a ...,/ t w . w�rF rr4 � 11nt a y Mt Mwr ^/� t ■ 1,it .. �Y� M. �-� AMIA SPECIFICATIONS i SCALE: NOT TO SCALE DETAIL NOT USED J SCALE: NOT TO SCALE n� DETAIL NOT USED SCALE: NOT TO SCALE A� DETAIL NOT USED SCALE: NOT TO SCALE Planning Administrative Approval COFFELL 03125/2021 • III T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 520 South Main Street, Suite 2531 Akron, OH 4 11 330.572.2100 Fax 330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 70'-9" MONOPOLE L GPD JOB NUMBER: 2020724.78.876558.01 J ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIMINARY MRL 0 03/05/2021 DTC FINAL CDs MRL CHRISTOPHER J. SCHEKS i oi, 111xi36 :�• is ...... 03/05/2021 GPD Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-9 0 A SBS IingtTBrmiral �•• TP.rP. .f VI',V`ll`!r'f.3fi0i15 fJFF.""fnrmfiieT° Ti po'ryaeCef� EL.`. rraz Terriri 3l battarftaHYar aier,tls the teenrl,ml Ie. darg„v rrma vvwsaat3 ses Baran• r.rga, PweerGafe 5'�5 Nrnt-ennlrq rlorohlors Iota In the Lei�ita a' Thin FIl'o P-L, 7PPL)trchnology cuchac Irnglifc,high pnFrgf can=_ry an7 sunen rr sren ure-Trey a �r re r.re� etseddmal cycicrarf ormanre In bath float arc `Bet the rqe aprl Intiors, cv51 Ir the aottcsl and harshasl opa�.ting arwrrnmrrn; Vl;ee nlmRicreltielr Peyulat::t Leetl Acid IJFiV.1l 4bccrboi Glo oc 41at W.GMI 6otton� rtruAOc-o c7ac dr'kL homy onnlrlev ard-reraEnt porvar cutecas, amrn7 ege Ir'r'L techno cyx nah; P>rrei�af:: SB^u battxri::e tle perteR Soletior -ol th 1,II B p N g -d,i olt ay -I nlJ- netw rk Pw Sr Si5hll 'i d'y '.Ili,1'g fy ill sI d 't -ii Unrqp' p dii,q llPg' 91 III 9 P r 'rAi bll I' ThDie IIo substlthte for Poty &ale SEE-rort Term nal batleri e:. FhaNmsard Bcaeloa • Cepe�i 'a nye _1-19oA1 • 121,'monoeloe ton`OJYOII]i: • N1 III'nn'101ira11rrF avallahla T- year :hell Ii-e 5 H�•1'['.a corrpllart • Pr rvxllin L'. ;xlilrxl IN iah e, I, l::rs ty end c,: Ing caplbllN �' RF4F EVF L'13t do d yky,-r-yl-i PC1'NER� PoLtuuI111a. JI3 8M3fFdme3P8 BATTERY SPECS SCALE: NOT TO SCALE DETAIL NOT USED �SCALE: NOT TO SCALE Co 1 t1 L d3n=ry h yeal3q fir- Th= i h �abzofi tl M Pnt g.mase r tlt�req.r:=<elf d' N dfl ms 3�d cwe rPade-rcrnf arse r:`ar];r. i1 aavo „rr,-Ia, monNie, <,am.�.;nen,rla a evert in,,- d mmo=rFerc ozypan R. Ila[I Y Upetallon r3Lad Lfi gl v,dhly raw Nardi ry 3--11 D -,l'F rlea:a toe wrc0.loreorr�loteden lc ofrp o> rn y°5x I sin, E°,� a.w,�vh v�el�e.t':.;sEe m c vuw.vM Lur1lPm+m eu1lnlrtil �. d -. I�IFF�TMIrrtor�Lmwlz � (Uti�[FibrY,_� inr rmn r.rn rr >f`��pr nre`iro u� miammoNEEMEM �ereral SFedlka;lans 565F8� 6 �31F p:1n 11.9 3)3 3k) 91L 6F In 2Ei 113 12A alGo� ME Nk 03i 1A 0.G5 1E1 A11 n0] 1EI ]]3 IFb ].� 5-111 2 m 113 m3 lio vl of N ran 13.1 Imo 1. 1 lrl GT 1. B1. i513 G12 n83 .[5 153 23b 3'4 595C11 6 £1 16 AI A.I] 106 G.I iS 61b 98 iti Fk) MEN I ix 139 1. A36 13 !fG IB A3a R] 6r51101 82 Im it 1 A 5l9b] IQ IS b7 711 539 210 'E] MfN I5V Sn3 116 Gm [ 8 1F3 ] 5 e1 .5 I - u w -nd tie 6r5111 8 I8< 1G 1 d 4i3 bA lK 08 21 11: 28 TA 2b) Mf N 2F� 3 r 85 1 A A94 .2 02 1A g1 11 G6G13[F G . 19 liC 12. £I 4T li 24 )G 1S G)) :oA ;S M[N 2l4 )i Z311: A)G ND ill 32G uA q9 s5 olr- 14f so51Wr-112r MIIMrriff nor SBS CI IF • �� t �-t wnxear S THIS DETAIL HAS NOT BEEN REVIEWED BY THE STAMPING PARTY. THEREFOR, THE STAMPING PARTY MAKES NO REPRESENTATION(S) WITH RESPECT TO ITS CONTENTS, AND SHALL NOT BE LIABLE FOR SUCH. THIS DETAIL IS FOR REFERENCE ONLY. ANY RELIANCE ON THIS DETAIL SHALL BE AT THE RELYING PARTY(IES)'S OWN RISK AND HEREBY WAIVES ANY AND ALL CLAIM(S) RELATED TO THE EXISTENCE OF THE STAMP OR OTHERWISE. BATTERY INFORMATION (BATTERY ELECTROLYTE DATA-12V MONOBLOCS) TOTAL # OF TOTAL ELECTROLYTE TOTAL ELECTROLYTE % SULFURIC ACID VOLUME/UNIT BATTERY MODEL BATTERY UNITS VOLUME (GAL.) WEIGHT (LBS.) ACID BY ELECTROLYTE INSTALLED PER UNIT PER UNIT VOLUME = VOLUME PER UNIT ENERSYS POWERSAFE SBS FRONT TERMINAL 8 2.34 GAL. 25.3 LBS. 28.2% = 0.66 GAL./2.34 GAL (SBS 190F) % SULFURIC TOTAL ACID WEIGHT TOTAL TOTAL UNITS X TOTAL TOTAL UNITS X ACID BY TOTAL ELECTROLYTE SULPHURIC SULPHURIC SULPHURIC ACID WEIGHT= WEIGHT VOLUME (GAL.)= VOLUMEIUNITS WEIGHT(LBS.)= WEIGHT/UNIT 5.28 GAL. = 8 UNITS X 80.8 LBS. = 8 UNITS X 39.9% = 10.1 LBS./25.3 LBS. 0.66 GAUUNIT 10.1 LBS. NFPA 1, CHAPTER 52 COMPLIANCE TOTAL ELECTROLYTE= 8 BATTERIES X 2.34 GAL/BATTERY = 18.72 GAL (SINCE -50 GAL OF ELECTROLYTE - REQUIREMENTS OF NFPA 1, CHAPTER 52 NOT APPLICABLE) IFC, CHAPTER 12, SECTION 1206 COMPLIANCE STATIONARY STORAGE BATTERY SYSTEMS HAVING CAPACITIES EXCEEDING THE VALUES SHOWN IN TABLE 1206.2 SHALL COMPLY w/ SECTION 1206.2.1 THROUGH 1206.2.12.6, AS APPLICABLE. BATTERY STORAGE SYSTEM THRESHOLD QUANTITIES BATTERY TECHNOLOGY CAPACITYALLOWED LEAD ACID, ALL TYPES 70 kWh (252 MEGAJOULES) AH = VOLTAGE (AH) / 1000 VOLTS AH I kWh NO. OF BATTERIES TOTAL kWh 12 190 1000 2.28 8 18.24 CONCLUSIONS 18.24 < 70 kWh SECTION 1206.2 DOES NOT APPLY BATTERY DATA CHART BATTERY DATA CHART SCALE: NOT TO SCALE A� DETAIL NOT USED SCALE: NOT TO SCALE Planning Administrative Approval COPPELL 03/25/2021 • w T • mMobile • 7668 WARREN PARKWAY FRISCO, TX 75034 0 CROWN v CASTLE 6191 N STATE HIGHWAY 161, SUITE 200 IRVING, TX 75038 GPD GROUP Professional Corporation 5211 Main Street, Suite 2531 Akron, Olf -11 330.572.2100 1330.572.2101 T-MOBILE SITE NUMBER: DA01328A BU #: 876558 F3 - COPPELL MIDDLE S 1301 WRANGLER COPPELL, TX 75017 EXISTING 71 MONOPOLE L GPD JOB NUMBER: 2020724.78.876558.01 ISSUED FOR: REV DATE DRWN DESCRIPTION DES./Q 0 02/09/2021 DTC PRELIMINARY MRL 0 03/05/2021 DTC FINAL CDs MRL tp�tt �F.r• ''shI, CHRI6TOPHER J. SCHEKS i oi, 111I836 :�• 94e••. ��ceFLse°.�'�' is ...... 03/05/2021 GPO Group, Professional Corporation Texas Registration No. 16477 TELECOM SEAL IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. SHEET NUMBER: REVISION: C-10 0 � J