DXL00116_843574_541515_10077674_COPPELL_(E_BELTLINE_RD)_AT&T.PRIORITY_Final_CD_04.07.2021_v1.ADM_APPAT&T SITE NUMBER:AT&T SITE NAME:AT&T FA CODE:AT&T PACE NUMBER:SITE TYPE:BUSINESS UNIT #:SITE ADDRESS:COUNTY:TOWER HEIGHT:DXL00116COPPELL (E BELTLINE RD)10077674MRNTX069640MONOPOLE843574DALLAS95'-0"200 EAST BELTLINE ROADCOPPELL, TX 75019PROJECT: AT&T PRIORITYIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0T-1REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0NOTE:PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THECROWN NOC AT (800) 788-7011 & CROWN CONSTRUCTION MANAGERALL DRAWINGS CONTAINED HEREIN ARE FORMATTED FOR 22"X34".CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTINGDIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALLIMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANYDISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BERESPONSIBLE FOR SAME.APPLICABLE CODESSITE INFORMATIONCARRIER/APPLICANT:SHEET #DRAWING INDEXSHEET DESCRIPTIONONCOR888-313-4747ELECTRIC PROVIDER:AT&T800-288-2020TELCO PROVIDER:GROUND ELEVATION:32° 56' 55.24"-96° 59' 22.02"UFACILITY IS UNMANNED AND NOT FORHUMAN HABITATIONOCCUPANCY CLASSIFICATION:A.D.A. COMPLIANCE:MAP/PARCEL #:CITY OF COPPELL, TXJURISDICTION:-COPPELL (E BELTLINE RD)DALLASAREA OF CONSTRUCTION:EXISTINGNAD83----PROPERTY OWNER:CROWN CASTLE USA, INC.1220 AUGUSTA DRIVEHOUSTON, TX 77057TOWER OWNER:IIBTYPE OF CONSTRUCTION:511.4 FT200 EAST BELTLINE ROADCOPPELL, TX 75019---CROWN CASTLE USA INC.SITE NAME:ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED INACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODESAS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING INTHESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMINGTO THESE CODES:CODE TYPE CODEBUILDING2015 IBCMECHANICAL2015 IMCELECTRICAL2014 NECPROJECT DESCRIPTIONLAT/LONG TYPE:LONGITUDE:LATITUDE:CURRENT ZONING:COUNTY:SITE ADDRESS:PROJECT TEAMA&E FIRM:CROWN CASTLEUSA INC. DISTRICTCONTACTS:CROWN CASTLE USA INC.2000 CORPORATE DRIVECANONSBURG, PA 15317CROWNAE.APPROVAL@CROWNCASTLE.COMTITLE SHEETT-1SITE PLANC-1C-2TOWER ELEVATION & ANTENNA PLANSGENERAL NOTEST-2EQUIPMENT DESCRIPTION TABLEBARCLAY HAWLEY - PROJECT MANAGER--THOMAS CZAPIEWSKI - CONSTRUCTION MANAGER--1220 AUGUSTA DRIVE, SUITE 500HOUSTON, TX 77057THE PURPOSE OF THIS PROJECT IS TO PROPOSE AN ANTENNAMODIFICATION ON AN EXISTING WIRELESS SITE.FINAL TOWER CONFIGURATION:·(12) ANTENNAS·(18) RRUs·(3) DIPLXERs·(4) RAYCAP J-BOXES·(12) COAX CABLES (7/8")·(6) COAX CABLES (1 5/8")·(3) FIBER CABLES (3/8")·(6) DC POWER CABLES (3/4")·(2) DC POWER CABLES (7/8")FINAL GROUND CONFIGURATION:·NO CHANGESC-3DETAILSC-4EQUIPMENT SPECSC-5G-1GROUNDING SCHEMATICG-2GROUNDING DETAILSLOCATION MAPNO SCALEDRIVING DIRECTIONS FROM NEAREST DALLAS-FORT WORTH INTERNATIONAL AIRPORT [INTERNATIONAL PKY N, DALLAS TX 75261 PKWY N].STAY ON TX-97 SPUR [INTERNATIONAL PKWY N]. ROAD NAME CHANGES TO TX-121 [INTERNATIONAL PKWY]. TAKE RAMP ONTO I-635 [LYNDON BJOHNSON FWY]. AT EXIT 33, TURN RIGHT ONTO RAMP. TURN LEFT (NORTH) ONTO (N) BELT LINE RD. TURN LEFT ONTO INGLE WAY. TURN LEFT ONTOLOCAL ROAD(S) AND FOLLOW TO THE SITE.AT&T TOWER ASSET GROUP1801 VALLEY VIEW LANEFARMERS BRANCH, TX 75234DESIGN PACKAGE BASED ON THE APPLICATIONID: 541515REVISION: 0CALL TEXAS ONE CALL(800) DIG-TESSCALL 3 WORKING DAYSBEFORE YOU DIG!STRUCTURAL ANALYSIS:DATED:BY OTHERSREFERENCE DOCUMENTS:MOUNT ANALYSIS:DATED:BY OTHERSSITE ID:DXL00116LAT: 32° 56' 55.24"LONG: -96° 59' 22.02"PLUMBING DIAGRAMC-1.1Planning AdministrativeApproval05/10/2021
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0T-2REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0CROWN CASTLE USA INC. SITE ACTIVITY REQUIREMENTS:1.NOTICE TO PROCEED- NO WORK SHALL COMMENCE PRIOR TO CROWN CASTLE USA INC. WRITTEN NOTICE TO PROCEED (NTP)AND THE ISSUANCE OF A PURCHASE ORDER. PRIOR TO ACCESSING/ENTERING THE SITE YOU MUST CONTACT THE CROWNCASTLE USA INC. NOC AT 800-788-7011 & THE CROWN CASTLE USA INC. CONSTRUCTION MANAGER.2."LOOK UP" - CROWN CASTLE USA INC. SAFETY CLIMB REQUIREMENT:THE INTEGRITY OF THE SAFETY CLIMB AND ALL COMPONENTS OF THE CLIMBING FACILITY SHALL BE CONSIDERED DURING ALLSTAGES OF DESIGN, INSTALLATION, AND INSPECTION. TOWER MODIFICATION, MOUNT REINFORCEMENTS, AND/OR EQUIPMENTINSTALLATIONS SHALL NOT COMPROMISE THE INTEGRITY OR FUNCTIONAL USE OF THE SAFETY CLIMB OR ANY COMPONENTS OFTHE CLIMBING FACILITY ON THE STRUCTURE. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: PINCHING OF THE WIRE ROPE,BENDING OF THE WIRE ROPE FROM ITS SUPPORTS, DIRECT CONTACT OR CLOSE PROXIMITY TO THE WIRE ROPE WHICH MAYCAUSE FRICTIONAL WEAR, IMPACT TO THE ANCHORAGE POINTS IN ANY WAY, OR TO IMPEDE/BLOCK ITS INTENDED USE. ANYCOMPROMISED SAFETY CLIMB, INCLUDING EXISTING CONDITIONS MUST BE TAGGED OUT AND REPORTED TO YOUR CROWNCASTLE USA INC. POC OR CALL THE NOC TO GENERATE A SAFETY CLIMB MAINTENANCE AND CONTRACTOR NOTICE TICKET.3.PRIOR TO THE START OF CONSTRUCTION, ALL REQUIRED JURISDICTIONAL PERMITS SHALL BE OBTAINED. THIS INCLUDES, BUT ISNOT LIMITED TO, BUILDING, ELECTRICAL, MECHANICAL, FIRE, FLOOD ZONE, ENVIRONMENTAL, AND ZONING. AFTER ONSITEACTIVITIES AND CONSTRUCTION ARE COMPLETED, ALL REQUIRED PERMITS SHALL BE SATISFIED AND CLOSED OUT ACCORDINGTO LOCAL JURISDICTIONAL REQUIREMENTS.4.ALL CONSTRUCTION MEANS AND METHODS; INCLUDING BUT NOT LIMITED TO, ERECTION PLANS, RIGGING PLANS, CLIMBINGPLANS, AND RESCUE PLANS SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR RESPONSIBLE FOR THE EXECUTIONOF THE WORK CONTAINED HEREIN, AND SHALL MEET ANSI/ASSE A10.48 (LATEST EDITION); FEDERAL, STATE, AND LOCALREGULATIONS; AND ANY APPLICABLE INDUSTRY CONSENSUS STANDARDS RELATED TO THE CONSTRUCTION ACTIVITIES BEINGPERFORMED. ALL RIGGING PLANS SHALL ADHERE TO ANSI/ASSE A10.48 (LATEST EDITION) AND CROWN CASTLE USA INC.STANDARD CED-STD-10253, INCLUDING THE REQUIRED INVOLVEMENT OF A QUALIFIED ENGINEER FOR CLASS IVCONSTRUCTION, TO CERTIFY THE SUPPORTING STRUCTURE(S) IN ACCORDANCE WITH ANSI/TIA-322 (LATEST EDITION).5.ALL SITE WORK TO COMPLY WITH QAS-STD-10068 "INSTALLATION STANDARDS FOR CONSTRUCTION ACTIVITIES ON CROWNCASTLE USA INC. TOWER SITE" AND LATEST VERSION OF ANSI/TIA-1019-A-2012 "STANDARD FOR INSTALLATION, ALTERATION,AND MAINTENANCE OF ANTENNA SUPPORTING STRUCTURES AND ANTENNAS."6.IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE ANALTERNATIVE INSTALLATION FOR APPROVAL BY CROWN CASTLE USA INC. PRIOR TO PROCEEDING WITH ANY SUCH CHANGEOF INSTALLATION.7.ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONSAND ORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES,RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALLWORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCALJURISDICTIONAL CODES, ORDINANCES AND APPLICABLE REGULATIONS.8.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'SRECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE.9.THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION.10.ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BEPROTECTED AT ALL TIMES AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED ASDIRECTED BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLINGPIERS AROUND OR NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILLINCLUDE BUT NOT BE LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING ANDEXCAVATION E) CONSTRUCTION SAFETY PROCEDURES.11.ALL SITE WORK SHALL BE AS INDICATED ON THE STAMPED CONSTRUCTION DRAWINGS AND PROJECT SPECIFICATIONS, LATESTAPPROVED REVISION.12.CONTRACTOR SHALL KEEP THE SITE FREE FROM ACCUMULATING WASTE MATERIAL, DEBRIS, AND TRASH AT THE COMPLETIONOF THE WORK. IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITEAND DISPOSED OF LEGALLY.13.ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THEWORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOTINTERFERE WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, TOWER OWNER, CROWNCASTLE USA INC., AND/OR LOCAL UTILITIES.14.THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATION FOR SITE SIGNAGEREQUIRED BY LOCAL JURISDICTION AND SIGNAGE REQUIRED ON INDIVIDUAL PIECES OF EQUIPMENT, ROOMS, AND SHELTERS.15.THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE CARRIER'S EQUIPMENT AND TOWER AREAS.16.THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACEAPPLICATION.17.THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT ORDRIVEWAY, SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION AS SPECIFIED ON THECONSTRUCTION DRAWINGS AND/OR PROJECT SPECIFICATIONS.18.CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IFREQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENTCONTROL.19.THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANYDAMAGED PART SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER.20.CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHERITEMS REMOVED FROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATEDLOCATION.21.CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILYBASIS.22.NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOTBE PLACED IN ANY FILL OR EMBANKMENT.CONCRETE, FOUNDATIONS, AND REINFORCING STEEL:1.ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN ANDCONSTRUCTION SPECIFICATION FOR CAST-IN-PLACE CONCRETE.2.UNLESS NOTED OTHERWISE, SOIL BEARING PRESSURE USED FOR DESIGN OF SLABS AND FOUNDATIONS IS ASSUMED TO BE 1000 psf.3.ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (f'c) OF 3000 psi AT 28 DAYS, UNLESS NOTED OTHERWISE. NO MORE THAN90 MINUTES SHALL ELAPSE FROM BATCH TIME TO TIME OF PLACEMENT UNLESS APPROVED BY THE ENGINEER OF RECORD. TEMPERATURE OFCONCRETE SHALL NOT EXCEED 90°f AT TIME OF PLACEMENT.4.CONCRETE EXPOSED TO FREEZE-THAW CYCLES SHALL CONTAIN AIR ENTRAINING ADMIXTURES. AMOUNT OF AIR ENTRAINMENT TO BE BASEDON SIZE OF AGGREGATE AND F3 CLASS EXPOSURE (VERY SEVERE). CEMENT USED TO BE TYPE II PORTLAND CEMENT WITH A MAXIMUMWATER-TO-CEMENT RATIO (W/C) OF 0.45.5.ALL STEEL REINFORCING SHALL CONFORM TO ASTM A615. ALL WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. ALL SPLICESSHALL BE CLASS "B" TENSION SPLICES, UNLESS NOTED OTHERWISE. ALL HOOKS SHALL BE STANDARD 90 DEGREE HOOKS, UNLESS NOTEDOTHERWISE. YIELD STRENGTH (Fy) OF STANDARD DEFORMED BARS ARE AS FOLLOWS:#4 BARS AND SMALLER40 ksi#5 BARS AND LARGER60 ksi6.THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS:CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH3"CONCRETE EXPOSED TO EARTH OR WEATHER:#6 BARS AND LARGER2"#5 BARS AND SMALLER1-1/2"CONCRETE NOT EXPOSED TO EARTH OR WEATHER:SLAB AND WALLS3/4"BEAMS AND COLUMNS1-1/2"7.A TOOLED EDGE OR A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, UNLESS NOTED OTHERWISE, INACCORDANCE WITH ACI 301 SECTION 4.2.4.GREENFIELD GROUNDING NOTES:1.ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION AND AC POWER GES'S) SHALL BE BONDED TOGETHER AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN ACCORDANCE WITH THE NEC.2.THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81) FOR GROUND ELECTRODE SYSTEMS, THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULTOF 5 OHMS OR LESS.3.THE CONTRACTOR IS RESPONSIBLE FOR PROPERLY SEQUENCING GROUNDING AND UNDERGROUND CONDUIT INSTALLATION AS TO PREVENT ANY LOSS OF CONTINUITY IN THE GROUNDING SYSTEM OR DAMAGE TO THE CONDUIT AND PROVIDE TESTING RESULTS.4.METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS OR BY BONDING ACROSS THE DISCONTINUITY WITH #6 COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT CLAMPS.5.METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED WITH THE POWER CIRCUITS TO BTSEQUIPMENT.6.EACH CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED SUPPLEMENTAL EQUIPMENT GROUND WIRES, #6 STRANDED COPPER OR LARGER FOR INDOOR BTS; #2 BARE SOLID TINNED COPPER FOR OUTDOOR BTS.7.CONNECTIONS TO THE GROUND BUS SHALL NOT BE DOUBLED UP OR STACKED BACK TO BACK CONNECTIONS ON OPPOSITE SIDE OF THE GROUND BUS ARE PERMITTED.8.ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/GROUND BARS AND THE GROUND RING SHALL BE #2 SOLID TINNED COPPER UNLESS OTHERWISE INDICATED.9.ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS.10.USE OF 90° BENDS IN THE PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED.11.EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE.12.ALL GROUND CONNECTIONS ABOVE GRADE (INTERIOR AND EXTERIOR) SHALL BE FORMED USING HIGH PRESS CRIMPS.13.COMPRESSION GROUND CONNECTIONS MAY BE REPLACED BY EXOTHERMIC WELD CONNECTIONS.14.ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED TO THE BRIDGE AND THE TOWER GROUND BAR.15.APPROVED ANTIOXIDANT COATINGS (i.e. CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS.16.ALL EXTERIOR GROUND CONNECTIONS SHALL BE COATED WITH A CORROSION RESISTANT MATERIAL.17.MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE GROUND RING, IN ACCORDANCE WITH THE NEC.18.BOND ALL METALLIC OBJECTS WITHIN 6 ft OF MAIN GROUND RING WITH (1) #2 BARE SOLID TINNED COPPER GROUND CONDUCTOR.19.GROUND CONDUCTORS USED FOR THE FACILITY GROUNDING AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL SUPPORT CLIPS OR SLEEVESTHROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC CONDUIT SHALL BE USED. WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (i.e., NONMETALLICCONDUIT PROHIBITED BY LOCAL CODE) THE GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT.20.ALL GROUNDS THAT TRANSITION FROM BELOW GRADE TO ABOVE GRADE MUST BE #2 BARE SOLID TINNED COPPER IN 3/4" NON-METALLIC, FLEXIBLE CONDUIT FROM 24" BELOW GRADE TO WITHIN 3" TO 6" OF CAD-WELD TERMINATION POINT. THE EXPOSED END OF THE CONDUITMUST BE SEALED WITH SILICONE CAULK. (ADD TRANSITIONING GROUND STANDARD DETAIL AS WELL).21.BUILDINGS WHERE THE MAIN GROUNDING CONDUCTORS ARE REQUIRED TO BE ROUTED TO GRADE, THE CONTRACTOR SHALL ROUTE TWO GROUNDING CONDUCTORS FROM THE ROOFTOP, TOWERS, AND WATER TOWERS GROUNDING RING, TO THE EXISTING GROUNDINGSYSTEM, THE GROUNDING CONDUCTORS SHALL NOT BE SMALLER THAN 2/0 COPPER. ROOFTOP GROUNDING RING SHALL BE BONDED TO THE EXISTING GROUNDING SYSTEM, THE BUILDING STEEL COLUMNS, LIGHTNING PROTECTION SYSTEM, AND BUILDING MAIN WATER LINE(FERROUS OR NONFERROUS METAL PIPING ONLY).120/240V, 1ØSYSTEMA PHASECONDUCTORCOLORB PHASEBLACKREDNEUTRALWHITEGROUNDGREENCONDUCTOR COLOR CODEELECTRICAL INSTALLATION NOTES:1.ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS, NEC AND ALL APPLICABLE FEDERAL, STATE, ANDLOCAL CODES/ORDINANCES.2.CONDUIT ROUTINGS ARE SCHEMATIC. CONTRACTOR SHALL INSTALL CONDUITS SO THAT ACCESS TO EQUIPMENT IS NOT BLOCKED AND TRIP HAZARDSARE ELIMINATED.3.WIRING, RACEWAY AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC.4.ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC.4.1.ALL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OF APPROVAL, AND SHALL CONFORM TO REQUIREMENT OF THE NATIONALELECTRICAL CODE.4.2.ALL OVERCURRENT DEVICES SHALL HAVE AN INTERRUPTING CURRENT RATING THAT SHALL BE GREATER THAN THE SHORT CIRCUIT CURRENT TOWHICH THEY ARE SUBJECTED, 22,000 AIC MINIMUM. VERYIFY AVAILABLE SHORT CIRCUIT CURRENT DOES NOT EXCEED THE RATING OF ELECTRICALEQUIPMENT IN ACCORDANCE WITH ARTICLE 110.24 NEC OR THE MOST CURRENT ADOPTED CODE PRE THE GOVERNING JURISDICTION.5.EACH END OF EVERY POWER PHASE CONDUCTOR, GROUNDING CONDUCTOR, AND TELCO CONDUCTOR OR CABLE SHALL BE LABELED WITHCOLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2" PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATIONMETHOD SHALL CONFORM WITH NEC AND OSHA.6.ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH LAMICOID TAGS SHOWING THEIR RATED VOLTAGE, PHASE CONFIGURATION, WIRECONFIGURATION, POWER OR AMPACITY RATING AND BRANCH CIRCUIT ID NUMBERS (i.e. PANEL BOARD AND CIRCUIT ID'S).7.PANEL BOARDS (ID NUMBERS) SHALL BE CLEARLY LABELED WITH PLASTIC LABELS.8.ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES.9.ALL POWER AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE COPPER CONDUCTOR (#14 OR LARGER) WITH TYPE THHW,THWN, THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED.10.SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE COPPER CONDUCTOR (#6 OR LARGER) WITH TYPE THHW, THWN,THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED.11.POWER AND CONTROL WIRING IN FLEXIBLE CORD SHALL BE MULTI-CONDUCTOR, TYPE SOOW CORD (#14 OR LARGER) UNLESS OTHERWISE SPECIFIED.12.POWER AND CONTROL WIRING FOR USE IN CABLE TRAY SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (#14 OR LARGER), WITH TYPE THHW, THWN,THWN-2, XHHW, XHHW-2, THW, THW-2, RHW, OR RHW-2 INSULATION UNLESS OTHERWISE SPECIFIED.13.ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRE NUTS BY THOMAS AND BETTS (OR EQUAL).LUGS AND WIRE NUTS SHALL BE RATED FOR OPERATION NOT LESS THAN 75° C (90° C IF AVAILABLE).14.RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND NEC.15.ELECTRICAL METALLIC TUBING (EMT), INTERMEDIATE METAL CONDUIT (IMC), OR RIGID METAL CONDUIT (RMC) SHALL BE USED FOR EXPOSED INDOORLOCATIONS.16.ELECTRICAL METALLIC TUBING (EMT) OR METAL-CLAD CABLE (MC) SHALL BE USED FOR CONCEALED INDOOR LOCATIONS.17.SCHEDULE 40 PVC UNDERGROUND ON STRAIGHTS AND SCHEDULE 80 PVC FOR ALL ELBOWS/90s AND ALL APPROVED ABOVE GRADE PVC CONDUIT.18.LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY ISNEEDED.19.CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SET SCREW FITTINGS ARE NOTACCEPTABLE.20.CABINETS, BOXES AND WIRE WAYS SHALL BE LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE AND THE NEC.21.WIREWAYS SHALL BE METAL WITH AN ENAMEL FINISH AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARDS (WIREMOLDSPECMATE WIREWAY).22.SLOTTED WIRING DUCT SHALL BE PVC AND INCLUDE COVER (PANDUIT TYPE E OR EQUAL).23.CONDUITS SHALL BE FASTENED SECURELY IN PLACE WITH APPROVED NON-PERFORATED STRAPS AND HANGERS. EXPLOSIVE DEVICES (i.e.POWDER-ACTUATED) FOR ATTACHING HANGERS TO STRUCTURE WILL NOT BE PERMITTED. CLOSELY FOLLOW THE LINES OF THE STRUCTURE, MAINTAINCLOSE PROXIMITY TO THE STRUCTURE AND KEEP CONDUITS IN TIGHT ENVELOPES. CHANGES IN DIRECTION TO ROUTE AROUND OBSTACLES SHALL BEMADE WITH CONDUIT OUTLET BODIES. CONDUIT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER. PARALLEL AND PERPENDICULAR TOSTRUCTURE WALL AND CEILING LINES. ALL CONDUIT SHALL BE FISHED TO CLEAR OBSTRUCTIONS. ENDS OF CONDUITS SHALL BE TEMPORARILY CAPPEDFLUSH TO FINISH GRADE TO PREVENT CONCRETE, PLASTER OR DIRT FROM ENTERING. CONDUITS SHALL BE RIGIDLY CLAMPED TO BOXES BY GALVANIZEDMALLEABLE IRON BUSHING ON INSIDE AND GALVANIZED MALLEABLE IRON LOCKNUT ON OUTSIDE AND INSIDE.24.EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES AND PULL BOXES SHALL BE GALVANIZED OR EPOXY-COATED SHEET STEEL. SHALL MEET OREXCEED UL 50 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND NEMA 3R (OR BETTER) FOR EXTERIOR LOCATIONS.25.METAL RECEPTACLE, SWITCH AND DEVICE BOXES SHALL BE GALVANIZED, EPOXY-COATED OR NON-CORRODING; SHALL MEET OR EXCEED UL 514A ANDNEMA OS 1 AND BE RATED NEMA 1 (OR BETTER) FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS.26.NONMETALLIC RECEPTACLE, SWITCH AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2 (NEWEST REVISION) AND BE RATED NEMA 1 (OR BETTER)FOR INTERIOR LOCATIONS AND WEATHER PROTECTED (WP OR BETTER) FOR EXTERIOR LOCATIONS.27.THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE CARRIER AND/OR CROWN CASTLE USA INC. BEFORECOMMENCING WORK ON THE AC POWER DISTRIBUTION PANELS.28.THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THEAPPLICABLE CODES AND STANDARDS TO SAFEGUARD LIFE AND PROPERTY.29.INSTALL LAMICOID LABEL ON THE METER CENTER TO SHOW "AT&T".30.ALL EMPTY/SPARE CONDUITS THAT ARE INSTALLED ARE TO HAVE A METERED MULE TAPE PULL CORD INSTALLED.120/208V, 3ØA PHASEB PHASEBLACKREDNEUTRALWHITEGROUNDGREENC PHASEBLUE277/480V, 3ØA PHASEB PHASEBROWNORANGE OR PURPLENEUTRALGREYGROUNDGREENC PHASEYELLOWDC VOLTAGEPOS (+)RED**NEG (-)BLACK**GENERAL NOTES:1.FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY:CONTRACTOR:GENERAL CONTRACTOR RESPONSIBLE FOR CONSTRUCTIONCARRIER:AT&TTOWER OWNER:CROWN CASTLE USA INC.2.THESE DRAWINGS HAVE BEEN PREPARED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDERSIMILAR CIRCUMSTANCES BY REPUTABLE ENGINEERS IN THIS OR SIMILAR LOCALITIES. IT IS ASSUMED THAT THE WORK DEPICTED WILL BEPERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKPEOPLE WHO HAVE A WORKING KNOWLEDGE OF THE APPLICABLE CODESTANDARDS AND REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR ELEMENT IS(OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICEFOR MISCELLANEOUS WORK NOT EXPLICITLY SHOWN.3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE MEANS OR METHODS OF CONSTRUCTION. THECONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES.THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY FOR PROTECTION OF LIFE AND PROPERTY DURING CONSTRUCTION. SUCHMEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO, BRACING, FORMWORK, SHORING, ETC. SITE VISITS BY THE ENGINEER OR HISREPRESENTATIVE WILL NOT INCLUDE INSPECTION OF THESE ITEMS AND IS FOR STRUCTURAL OBSERVATION OF THE FINISHED STRUCTURE ONLY.4.NOTES AND DETAILS IN THE CONSTRUCTION DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. WHERE NODETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT, AND/OR AS PROVIDED FOR IN THECONTRACT DOCUMENTS. WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES, AND SPECIFICATIONS, THE GREATER,MORE STRICT REQUIREMENTS, SHALL GOVERN. IF FURTHER CLARIFICATION IS REQUIRED CONTACT THE ENGINEER OF RECORD.5.SUBSTANTIAL EFFORT HAS BEEN MADE TO PROVIDE ACCURATE DIMENSIONS AND MEASUREMENTS ON THE DRAWINGS TO ASSIST IN THEFABRICATION AND/OR PLACEMENT OF CONSTRUCTION ELEMENTS BUT IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERIFYTHE DIMENSIONS, MEASUREMENTS, AND/OR CLEARANCES SHOWN IN THE CONSTRUCTION DRAWINGS PRIOR TO FABRICATION OR CUTTINGOF ANY NEW OR EXISTING CONSTRUCTION ELEMENTS. IF IT IS DETERMINED THAT THERE ARE DISCREPANCIES AND/OR CONFLICTS WITH THECONSTRUCTION DRAWINGS THE ENGINEER OF RECORD IS TO BE NOTIFIED AS SOON AS POSSIBLE.6.PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONSAND TO CONFIRM THAT THE WORK CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUNDSHALL BE BROUGHT TO THE ATTENTION OF CROWN CASTLE.7.ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS ANDORDINANCES. CONTRACTOR SHALL ISSUE ALL APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONSAND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLYWITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES, ORDINANCES ANDAPPLICABLE REGULATIONS.8.UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TOCOMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS.9.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESSSPECIFICALLY STATED OTHERWISE.10.IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVEINSTALLATION FOR APPROVAL BY THE CARRIER AND CROWN CASTLE PRIOR TO PROCEEDING WITH ANY SUCH CHANGE OF INSTALLATION.11.CONTRACTOR IS TO PERFORM A SITE INVESTIGATION AND IS TO DETERMINE THE BEST ROUTING OF ALL CONDUITS FOR POWER, AND TELCOAND FOR GROUNDING CABLES AS SHOWN IN THE POWER, TELCO, AND GROUNDING PLAN DRAWINGS.12.THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PARTSHALL BE REPAIRED AT CONTRACTOR'S EXPENSE TO THE SATISFACTION OF CROWN CASTLE USA INC.13.CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVEDFROM THE EXISTING FACILITY. ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION.14.CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION. TRASH AND DEBRIS SHOULD BE REMOVED FROM SITE ON A DAILY BASIS.* SEE NEC 210.5(C)(1) AND (2)** POLARITY MARKED AT TERMINATIONABBREVIATIONS:ANTANTENNA(E)EXISTINGFIFFACILITY INTERFACE FRAMEGENGENERATORGPSGLOBAL POSITIONING SYSTEMGSMGLOBAL SYSTEM FOR MOBILELTELONG TERM EVOLUTIONMGBMASTER GROUND BARMWMICROWAVE(N)NEWNECNATIONAL ELECTRIC CODE(P)PROPOSEDPPPOWER PLANTQTYQUANTITYRECTRECTIFIERRBSRADIO BASE STATIONRETREMOTE ELECTRIC TILTRFDSRADIO FREQUENCY DATA SHEETRRHREMOTE RADIO HEADRRUREMOTE RADIO UNITSIADSMART INTEGRATED DEVICETMATOWER MOUNTED AMPLIFIERTYPTYPICALUMTSUNIVERSAL MOBILE TELECOMMUNICATIONS SYSTEMW.P.WORK POINTWHITEPROPOSED EXCAVATIONTEMPORARY SURVEY MARKINGSELECTRIC POWER LINES, CABLES, CONDUIT,AND LIGHTING CABLESGAS, OIL, STEAM, PETROLEUM, OR GASEOUSMATERIALSPOTABLE WATERRECLAIMED WATER, IRRIGATION, ANDSLURRY LINESCOMMUNICATION, ALARM OR SIGNAL LINES,CABLES, OR CONDUIT AND TRAFFIC LOOPSSEWERS AND DRAIN LINESAPWA UNIFORM COLOR CODE:PINKREDYELLOWBLUEPURPLEORANGEGREENPlanning AdministrativeApproval05/10/2021
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-1REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0SITE PLAN DISCLAIMER:PROPERTY LINES AND STRUCTURES HAVE BEEN DIGITIZED FROMPREVIOUS PLAN SETS OR FROM CCISITES. PM&A HAS NOTCOMPLETED A SITE SURVEY AND THEREFORE MAKES NO CLAIMSAS TO THE ACCURACY OF INFORMATION DEPICTED ON THIS SHEET.CONTRACTOR SHALL FIELD VERIFY SITE PLAN & EQUIPMENTSHOWN AGAINST PRESENT FIELD CONDITIONS.IF PLANS DO NOT MATCH UP WITH SITE CONDITION AT TIME OFCONSTRUCTION, CONTACT AT&T AND THE CROWN CASTLE CM.AT&T MOBILITY21'-0'' X 21'-0''BUILDING/AREA(E) (UNKNOWN)CARRIER250 SQ. FT.PAD(E) COMPOUNDCHAIN LINK FENCE(E) AT&T ICEBRIDGE(E) 95'-0"MONOPOLE(E) 7'-0" X 7'-0'FND PAD(E) (UNKNOWN)CARRIER220 SQ. FT.PAD(E)(ABANDONED)CARRIER3'-0"x3'-0"PADPlanning AdministrativeApproval05/10/2021
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-1.1REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0Planning AdministrativeApproval05/10/2021
TOWER & ANTENNA STANDARD NOTES:A.DIRECT TOWER MOUNTED EQUIPMENT MUST NOT TRAP ORINTERFERE W/ CLIMBING PEGS/STEPS AND SAFETY CLIMB.B.NEW EQUIPMENT CANNOT BE MOUNTED DIRECTLY TOTOWER. NEW EQUIPMENT MUST BE MOUNTED TO CUSTOMERMOUNT.C.CONTRACTOR TO VERIFY ALL ANTENNA TIP HEIGHTS DONOT EXCEED BEACON BASE HEIGHT.D.VERIFY AZIMUTHS WITH RFDS.E.MOUNT & TOWER COMPLIANCE IS BY OTHERS. NO NEWANTENNAS OR EQUIPMENT SHALL BE INSTALLED ON MOUNTSOR TOWER WITHOUT THE APPROVAL OF A PROFESSIONALENGINEER.F.PROPOSED ANTENNA PLACEMENT LOCATION TO BE FIELDVERIFIED BY GENERAL CONTRACTOR PRIOR TOCONSTRUCTION TO AVOID ANY INTERFERENCE ORSHADOWING OF EXISTING OR PROPOSED ANTENNAS. IFINTERFERENCE OR SHADOWING OF ANTENNAS ISDISCOVERED DURING FIELD VERIFICATION, PLEASECONTACT A&E VENDOR FOR DESIGN REVISION PRIOR TOANY NEW ANTENNA INSTALLATION.G. DO NOT OBSTRUCT BEACON IF TOWER LIT.IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-2REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0AT&T RAD CENTERELEV. = 77'-0" A.G.L.(E) 95'-0" MONOPOLE TOWER(E) & (P) AT&T CABLES(12) COAX CABLES (7/8")(6) COAX CABLES (1 5/8")(3) FIBER CABLES (3/8")(6) DC POWER CABLES (3/4")(2) DC POWER CABLES (7/8")ROUTED UP TOWER TO ANTENNAPER STRUCTURAL ANALYSISNOTE:G.C. TO FEILD VERIFY ANTENNAPLACEMENT WITH THE AT&T CM PRIORTO INSTALL.NOTES:1. PM&A HAS NOT PERFORMED A STRUCTURAL ANALYSIS OF THE EXISTING TOWER OR PROPOSED ANTENNA MOUNT. REFER TOSTRUCTURAL ANALYSIS OR STRUCTURAL LETTER BY [TBD]. DATED [TBD]. PROJECT # [TBD]. NO NEW ANTENNAS OR EQUIPMENTINSTALLED WITHOUT APPROVAL OF STRUCTURAL ENGINEER AND CROWN CASTLE.2. IF THE TOWER STRUCTURAL ANALYSIS SHOWS THE NEED FOR TOWER REINFORCEMENT, REFER TO TOWER REINFORCEMENT DESIGNPRIOR TO THE INSTALLATION OF ANY PROPOSED EQUIPMENT.3. REFER TO TOWER STRUCTURAL ANALYSIS FOR PROPOSED ANTENNA CABLE ROUTING AND ATTACHMENT DETAILS.4. TOWER ELEVATION SHOWN IS NOT DRAWN TO SCALE AND IS INTENDED ONLY FOR REFERENCE PURPOSES. REFER TO ORIGINALTOWER DESIGN FOR ADDITIONAL INFORMATION.NOTE: THE TOWER DRAWING IS ONLY AGRAPHIC REPRESENTATION OF THESTRUCTURE. THE ACTUAL TOWER IN THE FIELDMAY VARYNOTE:NEW EQUIPMENT CANNOT BEMOUNTED TO TOWER. RELOCATEEXISTING TOWER MOUNTEDEQUIPMENT TO CUSTOMER MOUNT.ANY AND ALL TOWERMOUNTED EQUIPMENT MUSTNOT TRAP OR INTERFERE W/EXISTING SAFETY CLIMBAT&T EQUIPMENTANTENNA CL: 77'-0"MOUNT CL: 75'-0"NOTE:DIRECT TOWER MOUNTED EQUIPMENTMUST NOT TRAP OR INTERFERE WITHCLIMBING PEGS/STEPS AND SAFETYCLIMB. DO NOT OBSTRUCT BEACONIF TOWER LIT.(E) & (P) AT&T TOWER TOP EQUIPMENT,SEE PLAN AT RIGHT FOR DETAILS.(E) CARRIER ANTENNATOP EQUIPMENT (TYP)ALPHA8° AZIMUTHGAMMA248° AZIMUTH(E) AT&T COVP TO REMAINRAYCAP / DC6-48-60-18-8C(2 TOTAL)(E) AT&T RRUS TO REMAIN / RELOCATEERICSSON / RRUS 32 B30(3 TOTAL, 1 PER SECTOR)(E) AT&T RRUS TO BE REMOVEDERICSSON / RRUS 11 B12(3 TOTAL, 1 PER SECTOR)(E) AT&T ANTENNA TO REMAINCOMMSCOPE / JAHH-65B-R3B(6 TOTAL, 2 PER SECTOR)(E) AT&T RRUS TO REMAINERICSSON / RRUS 4478 B14(3 TOTAL, 1 PER SECTOR)(E) AT&T ANTENNA TO BE REMOVEDANDREW / SBNHH-1D65B(6 TOTAL, 2 PER SECTOR)(E) AT&T RRUS TO REMAINERICSSON / RRUS 32 B2(3 TOTAL, 1 PER SECTOR)(E) AT&T DUAL MOUNTANTENNA BRACKET TO REMAIN(3 TOTAL, 1 PER SECTOR)(E) AT&T RRUS TO REMAINERICSSON / RRUS 4478 B5(3 TOTAL, 1 PER SECTOR)(E) AT&T RRUS TO REMAINERICSSON / RRUS 32 B66(3 TOTAL, 1 PER SECTOR)GAMMA248° AZIMUTHBETA
150 ° AZIM
U
T
H
ALPHA8° AZIMUTH(P) AT&T ANTENNAERICSSON / AIR 6449 B77D(3 TOTAL, 1 PER SECTOR)(P) AT&T RRUSERICSSON / RRUS 4478 B12(3 TOTAL, 1 PER SECTOR)(P) AT&T DIPLEXERSCOMMSCOPE / CBC78TDS-43(3 TOTAL, 1 PER SECTOR)(P) AT&T ANTENNACOMMSCOPE / NNH4-65B-R6H4(3 TOTAL, 1 PER SECTOR)BETA
150 ° AZIM
U
T
H(E) AT&T COVP TO REMAINRAYCAP / DC6-48-60-18-8F(1 TOTAL)(E) AT&T COVPRAYCAP / DC6-48-60-18-8C(2 TOTAL)(E) AT&T RRUS ERICSSON / RRUS 32 B30(3 TOTAL, 1 PER SECTOR)(E) AT&T ANTENNACOMMSCOPE / JAHH-65B-R3B(6 TOTAL, 2 PER SECTOR)(E) AT&T RRUS ERICSSON / RRUS 4478 B14(3 TOTAL, 1 PER SECTOR)(E) AT&T RRUSERICSSON / RRUS 32 B2(3 TOTAL, 1 PER SECTOR)(E) AT&T DUAL MOUNTANTENNA BRACKET(3 TOTAL, 1 PER SECTOR)(E) AT&T RRUSERICSSON / RRUS 4478 B5(3 TOTAL, 1 PER SECTOR)(E) AT&T RRUS ERICSSON / RRUS 32 B66(3 TOTAL, 1 PER SECTOR)(E) AT&T COVPRAYCAP / DC6-48-60-18-8F(1 TOTAL)(P) AT&T COVP RAYCAP / DC6-48-60-18-8C-EV(1 TOTAL)Planning AdministrativeApproval05/10/2021
3/8" FIBER31IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-3REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0RAYCAP / D6-48-60-18-8F7/8" COAX123/4" DC POWER67/8" DC POWER2ANTENNA (A1)8°77'-0"ALPHAANTENNA (A2)ANTENNA (A3)ANTENNA (A4)CATEGORYPROPOSED CONFIGURATIONQTY.ANTENNAAZIMUTHANTENNAELEVATIONANTENNASECTORTOWER TOP EQUIPMENT SCHEDULE (FINAL)ANTENNA (B1)150°77'-0"BETAANTENNA (B2)ANTENNA (B3)ANTENNA (B4)ANTENNA (B5)TMAsRRHsANTENNA (C1)248°77'-0"GAMMAANTENNA (C2)ANTENNA (C3)ANTENNA (C4)ANTENNA (C5)TOWER DIPLEXERSTMAsRRHsCOAX/FIBER/DCMISCELLANEOUSFILTERTOWER DIPLEXERSTMAsRRHsFILTERTOWER DIPLEXERSFILTER12COMMSCOPE / CBC78TDS-43_CCIV2--COMMSCOPE / JAHH-65B-R3BCOMMSCOPE / NNH4-65B-R6H4ERICSSON / AIR 6449 B77D-61-----RRUS-32 B66, RRUS-32 B30, RRUS-4478 B14,RRUS-4478 B5, RRUS-32 B2, RRUS-4478 B12MISCELLANEOUS1--------ANTENNA (A5)1 5/8" COAX612COMMSCOPE / CBC78TDS-43_CCIV2--COMMSCOPE / JAHH-65B-R3BCOMMSCOPE / NNH4-65B-R6H4ERICSSON / AIR 6449 B77D-61-----RRUS-32 B66, RRUS-32 B30, RRUS-4478 B14,RRUS-4478 B5, RRUS-32 B2, RRUS-4478 B121--------12COMMSCOPE / CBC78TDS-43_CCIV2--COMMSCOPE / JAHH-65B-R3BCOMMSCOPE / NNH4-65B-R6H4ERICSSON / AIR 6449 B77D-61-----RRUS-32 B66, RRUS-32 B30, RRUS-4478 B14,RRUS-4478 B5, RRUS-32 B2, RRUS-4478 B121--------2RAYCAP / D6-48-60-18-8C1RAYCAP / D6-48-60-18-8C-EVPlanning AdministrativeApproval05/10/2021
SNAP-IN HANGERDC/FIBER CABLEBUNDLEHANGER ADAPTER GROMMETBUTTERFLY HANGERBUTTERFLY HANGERDC/FIBER CABLEBUNDLEHANGER ADAPTER GROMMETCLIP-IN HANGERCLIP-IN HANGERDC/FIBER CABLEBUNDLESNAP-IN HANGERHANGER ADAPTERGROMMETDOUBLE CLAMPDC/FIBER CABLEBUNDLEHANGER ADAPTER GROMMETSNAP-IN HANGERIT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-4REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0NEW ANTENNAINSTALLER NOTES:1.COMPLY WITH MANUFACTURERS INSTRUCTIONS TOENSURE THAT ALL RRHs RECEIVE ELECTRICAL POWERWITHIN 24 HOURS OF BEING REMOVED FROM THEMANUFACTURER'S PACKAGING.2.DO NOT OPEN RRH PACKAGES IN THE RAIN.3.ALL PIPES, BRACKETS, AND MISCELLANEOUSHARDWARE TO BE GALVANIZED UNLESS NOTEDOTHERWISE.ANTENNAMOUNTING PIPEMOUNTING BRACKET(SUPPLIED W/ ANTENNA)MOUNTING BRACKET(SUPPLIED W/ ANTENNA)AT&T RRHAND HARDWARE SUPPLIEDBY MANUFACTURER (TYP)VALMONT - RRUDSMAND HARDWARE (TYP)MOUNTING PIPE(TYP)Planning AdministrativeApproval05/10/2021
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0C-5REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0Planning AdministrativeApproval05/10/2021
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-1REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0#6 STRANDED CU WIRE WITHGREEN, 600V, THWN INSULATION(OR AS PROVIDED WITH GROUNDKIT) (TYP)2/0 TINNED BARECOPPER WIREEXOTHERMIC WELD (TYP)GROUND WIRENOTE 3GROUND WIRESEE NOTE 3NOTES:1.NUMBER OF GROUNDING BARS MAY VARY DEPENDING ON THE TYPE OF TOWER, ANTENNA LOCATIONS ANDCONNECTION ORIENTATION. COAXIAL CABLES EXCEEDING 200 FEET ON THE TOWER SHALL HAVE GROUNDKITS AT THE MIDPOINT. PROVIDE AS REQUIRED.2.ONLY MECHANICAL CONNECTIONS ARE ALLOWED TO BE MADE TO CROWN CASTLE USA INC. TOWERS. ALLMECHANICAL CONNECTIONS SHALL BE TREATED WITH AN ANTI-OXIDANT COATING.3.ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF THE RECOGNIZED EDITION OFANSI/TIA 222 AND NFPA 780.ANTENNA GROUND BARLOCATED AT MCL(BONDED TO TOWER STEEL)2 HOLE LUG (TYP)COAX GROUND BAR WITHINSULATORS, CONNECTEDDIRECTLY TO THE BOTTOM OFMONOPOLE. SEE NOTE 1.MECHANICAL CONNECTION(TYP)MONOPOLE PIERMONOPOLEâ„„TO BTS EQUIPMENT VIATRAY OR ICE BRIDGECOAX CABLE(TYP FOR ALL)STANDARD COAXCABLE GROUND KIT(TYP)INSPECTION WELLTO ANTENNATO TOWER MOUNTED EQUIPMENT(TYP)T/FINISH GRADECADWELD TEST LOOP TOGROUND RING WIRE8" PVC PLUG8" PVC PLUG CPLG. (THRD.)#2 SOLID (TEST LOOP)NOTCH SIDES OF 8" PVC SCH 40 PIPETO ALLOW EXIT/ENTRANCE OFGROUND RING WIRETRENCH BOTTOM2/0 TINNED CU EXTERNALTOWER GROUND RING WIRE5/8" Ø x 10'-0" LONG COPPER CLAD GROUND RODNOTES:1.GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL2.GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D)EXOTHERMIC WELDGRADENOTES:1.GROUND ROD SHALL BE DRIVEN VERTICALLY, NOT TO EXCEED 45 DEGREES FROM THE VERTICAL2.GROUND WIRE SHALL BE MIN. 30" BELOW GRADE OR 6" BELOW FROST LINE. (WHICH EVER IS GREATER) AS PER N.E.C. ARTICLE 250-50(D)EXOTHERMIC WELDGROUND RING #2 COPPER WIRE SOLID,TINNED FOR CARRIER AND ICE BRIDGEGROUND LOOPGROUND RING 2/0 FORTOWER GROUND LOOPGROUND ROD COPPER CLADSTEEL ROD W/MIN. 5/8 Ø x10'-0" LONG6" WIDE METALLIC HTELWARNING/LOCATOR TAPE AT 12"DEPTHNOTES:1.DOUBLING UP "OR STACKING" OF CONNECTIONS IS NOT PERMITTED.2.EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.3.GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL.TO ANTENNA COAXTWO HOLE LONG BARREL COMPRESSIONLUG (TYP)NOTES:1.EXTERIOR ANTIOXIDANT JOINT COMPOUND TO BE USED ON ALL EXTERIOR CONNECTIONS.2.GROUND BAR SHALL NOT BE ISOLATED FROM TOWER. MOUNT DIRECTLY TO TOWER STEEL (TOWER ONLY).3.GROUND BAR SHALL BE ISOLATED FROM BUILDING OR SHELTER.#2 SOLID TINNED COPPERCONDUCTOR TO TOWER/SHELTERGROUND RING (2 TYP. FOR BOTTOMGROUND BAR ONLY)TWO HOLE LONG BARREL COMPRESSION LUG (TYP)SINGLE CONNECTOR AT GROUND BARSSTAINLESS STEELFLAT WASHER(TYP)STAINLESS STEEL NUT(TYP)GROUNDBARSTAINLESS STEELFLAT WASHER(TYP)STAINLESS STEEL BOLT(TYP)STAINLESS STEELBELLVILLE WASHER(TYP)STAINLESS STEELFLAT WASHER(TYP)STAINLESS STEEL NUT(TYP)STEELSTAINLESS STEELFLAT WASHERSTAINLESS STEEL BOLTSTAINLESS STEELBELLVILLE WASHER(TYP)2-HOLE CRIMP/COMPRESSIONCONNECTORDRAGON TOOTH WASHER(TYP)SINGLE CONNECTOR AT STEEL OBJECTSSTAINLESS STEELFLAT WASHER(TYP)METALLIC OBJECTDRAGON TOOTHWASHER(TYP)2-HOLE CRIMP/COMPRESSIONCONNECTORSTAINLESS STEELSELF-DRILLINGMETAL SCREW (TYP)SINGLE CONNECTOR AT METALLIC/STEEL OBJECTS2-HOLE CRIMP/COMPRESSIONCONNECTORCOPPER/GALVANIZED GROUND BARTO ANTENNA COAXCOPPER/GALVANIZED GROUND BARPlanning AdministrativeApproval05/10/2021
IT IS A VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY ARE ACTING UNDER THE DIRECTIONOF A LICENSED PROFESSIONAL ENGINEER,TO ALTER THIS DOCUMENT.0G-2REVISION:SHEET NUMBER:ISSUED FOR:DRWNREVDESCRIPTIONDES./QADATE9045 RIVER ROAD, SUITE 425INDIANAPOLIS, IN 4624004/01/20211801 VALLEY VIEW LANEFARMERS BRANCH TX 75234AT&T SITE NUMBER: DXL00116BU #: 843574COPPELL (E BELTLINE RD)200 EAST BELTLINE ROADCOPPELL, TX 75019EXISTING 95'-0" MONOPOLE6801 PORTWEST DR. STE 100,HOUSTON, TX 77024OFFICE 713-677-0964P. MARSHALL & ASSOCIATES21CA6M-124FIRM REGISTRATION #:13897FIRM REGISTRATION #:13897VTVTFINAL0NOTE: MINIMUM OF3 THREADS TO BEVISIBLE(TYP)2 HOLE LONGBARREL TINNEDSOLID COPPERLUG(TYP)TIN COATED SOLIDCOPPER BUS BARCHERRY INSULATORINSTALLED IF REQUIREDS/S NUT(TYP)S/S SPLITWASHER(TYP)S/S FLATWASHER(TYP)S/S FLATWASHER(TYP)S/S BOLT(TYP)NOTES:1.ALL GROUNDING LUGS ARE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ALLHARDWARE BOLTS, NUTS, LOCK WASHERS SHALL BE STAINLESS STEEL. ALL HARDWARE ARE TO BE ASFOLLOWS: BOLT, FLAT WASHER,GROUND BAR, GROUND LUG, FLAT WASHER AND NUT.BURNDY GROUND LUG W/LONG BARREL(SEE CHART)BURNDY TWO HOLE LUG W/LONG BARREL(SEE CHART)BARE WIRE TO BENO-OX AT BOTH ENDSGROUNDINGCONDUCTORNUT (TYP)LOCK WASHER(TYP)BOLT(SEE CHART)(TYP)GROUND BARSTRANDED (GREEN INSULATED) ONLY FOR #6 AWG(SEE CHART)WIRE SIZE#6 AWG GREEN INSULATED#2 AWG SOLID TINNED#2 AWG STRANDED#2/0 AWG STRANDED#4/0 AWG STRANDEDYA6C-2TC38YA3C-2TC38YA2C-2TC38YA26-2TC38YA28-2N1/2" - 16 NC S 2 BOLT3/8" - 16 NC S 2 BOLT3/8" - 16 NC S 2 BOLT3/8" - 16 NC S 2 BOLT3/8" - 16 NC S 2 BOLTBURNDY LUGBOLT SIZE*TWO HOLE LUG, OR EXOTHERMICWELD TO BE USED WITH #2 AWG BARECONDUCTOR WIRE TO BUILDINGSERVICE GROUND OR GROUND RING#6 AWG MIN. FROM ANTENNA CABLEGROUND KITGROUND BAR ON SHELTER. ICEBRIDGE, OR ON ANTENNA TOWER#2 TINNED SOLID IN 3/4" LIQUID TIGHT CONDUITFROM 24" BELOW GRADE TO WITHIN 3" TO 6" OFCAD-WELD TERMINATION POINT. EXPOSED ENDOF THE LIQUID TIGHT CONDUIT MUST BE SEALEDWITH SILICONE CAULK.TIE INTO EXISTING GROUND RINGTYPE VVTYPE GYTYPE GRTYPE VNTYPE NCTYPE VSTYPE VBTYPE SSTYPE PTNOTE:1.ERICO EXOTHERMIC "MOLD TYPES" SHOWN HERE ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC MOLDS TO BE USEDFOR THIS PROJECT.2.MOLD TYPE ONLY TO BE USED BELOW GRADE WHEN CONNECTING GROUND RING TO GROUND ROD.TYPE 2-YA-2TYPE XATYPE YA-2TYPE HSHEAT SHRINK(CLEAR)CABLE CONNECTORANTENNA CABLENOTES:1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWNTO GROUND BAR.2.GROUNDING KIT SHALL BE TYPE AND PART NUMBER AS SUPPLIED OR RECOMMENDED BYCABLE MANUFACTURER.3.WEATHER PROOFING SHALL BE TWO-PART TAPE KIT, COLD SHRINK SHALL NOT BE USED.#6 AWG WEATHERPROOFINGKIT (TYP)GROUND KIT (TYP)COPPER/GALVANIZED COAXGROUND BAR BONDEDDIRECTLY TOWERRX2ANTENNA CABLETO BTS EQUIPMENT (TYP.)TX1/RX1TO ANTENNASNOTES:1.DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TOANTENNA GROUND BAR.2.WEATHER PROOFING SHALL BE TWO-PART TAPE KIT. COLD SHRINK SHALL NOT BE USED.COAX JUMPER (TYP.)CONNECTORWEATHERPROOFING KIT(TYP. SEE NOTE 2)CADWELD(TYP)INSULATORSSEE NOTE 2.(TYP)WALL BRACKET(TYP)TW0-HOLECOMPRESSION LUGNOTES:1. DOWN LEAD (HOME RUN) CONDUCTORS ARE NOT TO BE INSTALLED ON CROWN CASTLE USA INC.TOWER, PER THE GROUNDING DOWN CONDUCTOR POLICY QAS-STD-10091. NO MODIFICATION ORDRILLING TO TOWER STEEL IS ALLOWED IN ANY FORM OR FASHION, CAD-WELDING ON THE TOWER AND/ORIN THE AIR ARE NOT PERMITTED.2. OMIT INSULATOR WHEN MOUNTING TO TOWER STEEL OR PLATFORM STEELUSE INSULATORS WHEN ATTACHING TO BUILDING OR SHELTERS.UNIVERSAL COPPERGROUND BAR (4"x20")LOCK WASHERP/N M10(TYP)3/8-11x1" TAMPERRESISTANT BOLT(TYP)TYPE GT²CABLE GROUND KITWEATHERPROOFING KIT(SEE NOTE 3)#6 AWG STRANDED COPPER GROUND WIRE (GROUNDEDTO GROUND BAR). SEE NOTE 1 & 2Planning AdministrativeApproval05/10/2021